메뉴 건너뛰기




Volumn 54, Issue 6, 2009, Pages 337-345

Non-contact monitoring of heart and lung activity using magnetic induction measurement in a neonatal animal model;Kontaktlose Überwachung von Atemtätigkeit und Herzaktion mittels magnetischer Bioimpedanzmessung in einem neonatalen Tiermodell

Author keywords

Heart activity; Lung activity; Magnetic induction measurement; Neonatal animal model; Non contact

Indexed keywords

ALTERNATING MAGNETIC FIELD; ANIMAL MODEL; CONFIDENCE INTERVAL; CONTINUOUS POSITIVE AIRWAY PRESSURES; CORRELATION COEFFICIENT; DETECTION RATES; EXCITATION COILS; FLOW RESISTANCE; HEART ACTIVITY; HIGH FREQUENCY; INTERFERENCE PROBLEMS; MAGNETIC INDUCTION; MEAN PRESSURES; MECHANICAL VENTILATION; NEWBORN PIGLET; NON-CONTACT; NON-CONTACT MONITORING; NON-INVASIVE; PRESSURE DIFFERENTIAL; PULSE OXIMETRY; REFERENCE SIGNALS; RESISTANCE CHANGE; SPONTANEOUS BREATHING; TOTAL RESISTANCE;

EID: 77249120630     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: 10.1515/BMT.2009.044     Document Type: Article
Times cited : (9)

References (26)
  • 2
    • 77249092418 scopus 로고    scopus 로고
    • In vitro measurement of iron concentration in human hepatic tissue by magnetic induction methods
    • Instanbul, Turkey, October 25-28, Abstract
    • Casañas R, Scharfetter H, Altes A, et al. In vitro measurement of iron concentration in human hepatic tissue by magnetic induction methods. Proc 23rd Annu EMBS Int Conf 2001, Instanbul, Turkey, October 25-28, 2001: Abstract.
    • (2001) Proc 23rd Annu EMBS Int Conf 2001
    • Casañas, R.1    Scharfetter, H.2    Altes, A.3
  • 3
    • 1342332811 scopus 로고    scopus 로고
    • Measurement of liver iron overload by magnetic induction using a planar gradiometer: Preliminary human results
    • Casañas R, Scharfetter H, Altes A, et al. Measurement of liver iron overload by magnetic induction using a planar gradiometer: preliminary human results. Physiol Meas 2004; 25: 315-323.
    • (2004) Physiol Meas , vol.25 , pp. 315-323
    • Casañas, R.1    Scharfetter, H.2    Altes, A.3
  • 4
    • 0026001662 scopus 로고
    • Cardiac output measurement in critical care patients: Thoracic electrical bioimpedance versus thermodilution
    • Clancy TV, Norman K, Reynolds R, Covington D, Maxwell JG. Cardiac output measurement in critical care patients: Thoracic electrical bioimpedance versus thermodilution. J Trauma 1991; 31: 1116-1121.
    • (1991) J Trauma , vol.31 , pp. 1116-1121
    • Clancy V, T.1    Norman, K.2    Reynolds, R.3    Covington, D.4    Maxwell, J.G.5
  • 5
    • 0027201173 scopus 로고
    • Thoracic electrical bioimpedance measurement of cardiac output-not ready for prime time
    • Clarke DE, Raffin TA. Thoracic electrical bioimpedance measurement of cardiac output-not ready for prime time. Crit Care Med 1993; 21: 1111-1112.
    • (1993) Crit Care Med , vol.21 , pp. 1111-1112
    • Clarke, D.E.1    Raffin, T.A.2
  • 7
    • 0036122758 scopus 로고    scopus 로고
    • Changes in electrical resistivity of swine liver after occlusion and postmortem
    • Haemmerich D, Ozkan OR, Tsai J-Z, et al. Changes in electrical resistivity of swine liver after occlusion and postmortem. Med Biol Eng Comput 2002; 40: 29-33.
    • (2002) Med Biol Eng Comput , vol.40 , pp. 29-33
    • Haemmerich, D.1    Ozkan, O.R.2    Tsai, J.-Z.3
  • 10
    • 0020577658 scopus 로고
    • Microprocessor-based long-term cardiorespirography. II. Status evaluation in term and premature newborns
    • Hoernchen H, Betz R, Kotlarek F, Roebruck P. Microprocessor-based long-term cardiorespirography. II. Status evaluation in term and premature newborns. J Perinat Med 1983; 11: 32-42.
    • (1983) J Perinat Med , vol.11 , pp. 32-42
    • Hoernchen, H.1    Betz, R.2    Kotlarek, F.3    Roebruck, P.4
  • 11
    • 0020531591 scopus 로고
    • Microprocessor-based long-term cardiorespirography. I. Heart rate changes and apneic attacks
    • Hoernchen H, Betz R, Siller V, Roebruck P. Microprocessor-based long-term cardiorespirography. I. Heart rate changes and apneic attacks. J Perinat Med 1983; 11: 26-31.
    • (1983) J Perinat Med , vol.11 , pp. 26-31
    • Hoernchen, H.1    Betz, R.2    Siller, V.3    Roebruck, P.4
  • 13
    • 0014744267 scopus 로고
    • Impedancecar-diography as a non invasive means to monitor cardiac function
    • Kubicek WG, Fron AH, Patterson RP, et al. Impedancecar-diography as a non invasive means to monitor cardiac function. J Assoc Adv Med Instrum 1970; 4: 79-84.
    • (1970) J Assoc Adv Med Instrum , vol.4 , pp. 79-84
    • Kubicek, W.G.1    Fron, A.H.2    Patterson, R.P.3
  • 15
    • 30744463596 scopus 로고    scopus 로고
    • Detection of brain oedema using magnetic induction tomography: A feasibility study of the likely sensitivity and detectability
    • Merwa R, Hollhaus K, Scharfetter H. Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability. Physiol Meas 2004; 25: 1-8.
    • (2004) Physiol Meas , vol.25 , pp. 1-8
    • Merwa, R.1    Hollhaus, K.2    Scharfetter, H.3
  • 17
    • 0033092343 scopus 로고    scopus 로고
    • Fiberoptic measurement of arterial oxygen saturation in premature and term neonates
    • Merz U, Peschgens T, Hoernchen H. Fiberoptic measurement of arterial oxygen saturation in premature and term neonates. Z Geburtshilfe Neonatol 1999; 203: 77-80.
    • (1999) Z Geburtshilfe Neonatol , vol.203 , pp. 77-80
    • Merz, U.1    Peschgens, T.2    Hoernchen, H.3
  • 18
    • 23044443163 scopus 로고    scopus 로고
    • Detection of emboli in vessels using electrical impedance measurements-phantom and electrodes
    • Nebuya S, Noshiro M, Brown BH, Smallwood RH, Milnes P. Detection of emboli in vessels using electrical impedance measurements-phantom and electrodes. Physiol Meas 2005; 26: S111-S118.
    • (2005) Physiol Meas , vol.26
    • Nebuya, S.1    Noshiro, M.2    Brown, B.H.3    Smallwood, R.H.4    Milnes, P.5
  • 21
    • 45749086561 scopus 로고    scopus 로고
    • Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)
    • Steffen M, Heimann K, Bernstein N, Leonhardt S. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Physiol Meas 2008; 29: 291-306.
    • (2008) Physiol Meas , vol.29 , pp. 291-306
    • Steffen, M.1    Heimann, K.2    Bernstein, N.3    Leonhardt, S.4
  • 22
    • 77249102472 scopus 로고    scopus 로고
    • Non-contact monitoring of heart and lung activity by magnetic impedance measurement
    • Nürnberg, Abstract
    • Steffen M, Leonhardt S. Non-contact monitoring of heart and lung activity by magnetic impedance measurement. 26. BTM Konferenz, Nürnberg 2005. Abstract.
    • (2005) 26. BTM Konferenz
    • Steffen, M.1    Leonhardt, S.2
  • 24
    • 0014340443 scopus 로고
    • Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction
    • Tarjan PP, McFee R. Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction. IEEE Trans Biomed Eng 1968; 15: 266-278.
    • (1968) IEEE Trans Biomed Eng , vol.15 , pp. 266-278
    • Tarjan, P.P.1    McFee, R.2
  • 25
    • 0034018919 scopus 로고    scopus 로고
    • Genesis of the normal and the abnormal arterial pulse
    • Vlachopoulos C, O'Rourke M. Genesis of the normal and the abnormal arterial pulse. Curr Probl Cardiol 2000; 25: 303-367.
    • (2000) Curr Probl Cardiol , vol.25 , pp. 303-367
    • Vlachopoulos, C.1    O'Rourke, M.2
  • 26
    • 0000667178 scopus 로고
    • Theoretische Untersuchung der Rückwirkung der Wirbelströme bei kontaktlosen Leitfähigkeitsmessungen
    • Wach P. Theoretische Untersuchung der Rückwirkung der Wirbelströme bei kontaktlosen Leitfähigkeitsmessungen. Elektrotech Maschinenbau 1979; 76: 505-509.
    • (1979) Elektrotech Maschinenbau , vol.76 , pp. 505-509
    • Wach, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.