-
1
-
-
0035421467
-
Imaging molten steel flow profiles
-
DOI 10.1088/0957-0233/12/8/320, PII S0957023301213010
-
Binns R, Lyons ARA, Peyton AJ, Pritchard WDN. Imaging molten steel flow profiles. Meas Sci Technol 2001; 12: 1132-1138. (Pubitemid 32760744)
-
(2001)
Measurement Science and Technology
, vol.12
, Issue.8
, pp. 1132-1138
-
-
Binns, R.1
Lyons, A.R.A.2
Peyton, A.J.3
Pritchard, W.D.N.4
-
2
-
-
77249092418
-
In vitro measurement of iron concentration in human hepatic tissue by magnetic induction methods
-
Instanbul, Turkey, October 25-28, Abstract
-
Casañas R, Scharfetter H, Altes A, et al. In vitro measurement of iron concentration in human hepatic tissue by magnetic induction methods. Proc 23rd Annu EMBS Int Conf 2001, Instanbul, Turkey, October 25-28, 2001: Abstract.
-
(2001)
Proc 23rd Annu EMBS Int Conf 2001
-
-
Casañas, R.1
Scharfetter, H.2
Altes, A.3
-
3
-
-
1342332811
-
Measurement of liver iron overload by magnetic induction using a planar gradiometer: Preliminary human results
-
Casañas R, Scharfetter H, Altes A, et al. Measurement of liver iron overload by magnetic induction using a planar gradiometer: preliminary human results. Physiol Meas 2004; 25: 315-323.
-
(2004)
Physiol Meas
, vol.25
, pp. 315-323
-
-
Casañas, R.1
Scharfetter, H.2
Altes, A.3
-
4
-
-
0026001662
-
Cardiac output measurement in critical care patients: Thoracic electrical bioimpedance versus thermodilution
-
Clancy TV, Norman K, Reynolds R, Covington D, Maxwell JG. Cardiac output measurement in critical care patients: Thoracic electrical bioimpedance versus thermodilution. J Trauma 1991; 31: 1116-1121.
-
(1991)
J Trauma
, vol.31
, pp. 1116-1121
-
-
Clancy V, T.1
Norman, K.2
Reynolds, R.3
Covington, D.4
Maxwell, J.G.5
-
5
-
-
0027201173
-
Thoracic electrical bioimpedance measurement of cardiac output-not ready for prime time
-
Clarke DE, Raffin TA. Thoracic electrical bioimpedance measurement of cardiac output-not ready for prime time. Crit Care Med 1993; 21: 1111-1112.
-
(1993)
Crit Care Med
, vol.21
, pp. 1111-1112
-
-
Clarke, D.E.1
Raffin, T.A.2
-
7
-
-
0036122758
-
Changes in electrical resistivity of swine liver after occlusion and postmortem
-
Haemmerich D, Ozkan OR, Tsai J-Z, et al. Changes in electrical resistivity of swine liver after occlusion and postmortem. Med Biol Eng Comput 2002; 40: 29-33.
-
(2002)
Med Biol Eng Comput
, vol.40
, pp. 29-33
-
-
Haemmerich, D.1
Ozkan, O.R.2
Tsai, J.-Z.3
-
8
-
-
0024230690
-
A non-invasive eletromagnetic conductivity sensor for biomedical applications
-
Hart LW, Ko HW, Meyer JH Jr, Vasholz DP, Joseph RI. A non-invasive eletromagnetic conductivity sensor for biomedical applications. IEEE Trans Biomed Eng 1988; 35: 1011-1022.
-
(1988)
IEEE Trans Biomed Eng
, vol.35
, pp. 1011-1022
-
-
Hart, L.W.1
Ko, H.W.2
Meyer Jr., J.H.3
Vasholz, D.P.4
Joseph I, R.5
-
10
-
-
0020577658
-
Microprocessor-based long-term cardiorespirography. II. Status evaluation in term and premature newborns
-
Hoernchen H, Betz R, Kotlarek F, Roebruck P. Microprocessor-based long-term cardiorespirography. II. Status evaluation in term and premature newborns. J Perinat Med 1983; 11: 32-42.
-
(1983)
J Perinat Med
, vol.11
, pp. 32-42
-
-
Hoernchen, H.1
Betz, R.2
Kotlarek, F.3
Roebruck, P.4
-
11
-
-
0020531591
-
Microprocessor-based long-term cardiorespirography. I. Heart rate changes and apneic attacks
-
Hoernchen H, Betz R, Siller V, Roebruck P. Microprocessor-based long-term cardiorespirography. I. Heart rate changes and apneic attacks. J Perinat Med 1983; 11: 26-31.
-
(1983)
J Perinat Med
, vol.11
, pp. 26-31
-
-
Hoernchen, H.1
Betz, R.2
Siller, V.3
Roebruck, P.4
-
13
-
-
0014744267
-
Impedancecar-diography as a non invasive means to monitor cardiac function
-
Kubicek WG, Fron AH, Patterson RP, et al. Impedancecar-diography as a non invasive means to monitor cardiac function. J Assoc Adv Med Instrum 1970; 4: 79-84.
-
(1970)
J Assoc Adv Med Instrum
, vol.4
, pp. 79-84
-
-
Kubicek, W.G.1
Fron, A.H.2
Patterson, R.P.3
-
15
-
-
30744463596
-
Detection of brain oedema using magnetic induction tomography: A feasibility study of the likely sensitivity and detectability
-
Merwa R, Hollhaus K, Scharfetter H. Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability. Physiol Meas 2004; 25: 1-8.
-
(2004)
Physiol Meas
, vol.25
, pp. 1-8
-
-
Merwa, R.1
Hollhaus, K.2
Scharfetter, H.3
-
16
-
-
0029397543
-
Computer-assisted monitoring in the neonatal intensive care unit
-
Merz U, Peschgens T, Budde R, Kretzschmann F, Hoernchen H. Computer-assisted monitoring in the neonatal intensive care unit. Klin Padiatr 1995; 207: 331-333.
-
(1995)
Klin Padiatr
, vol.207
, pp. 331-333
-
-
Merz, U.1
Peschgens, T.2
Budde, R.3
Kretzschmann, F.4
Hoernchen, H.5
-
17
-
-
0033092343
-
Fiberoptic measurement of arterial oxygen saturation in premature and term neonates
-
Merz U, Peschgens T, Hoernchen H. Fiberoptic measurement of arterial oxygen saturation in premature and term neonates. Z Geburtshilfe Neonatol 1999; 203: 77-80.
-
(1999)
Z Geburtshilfe Neonatol
, vol.203
, pp. 77-80
-
-
Merz, U.1
Peschgens, T.2
Hoernchen, H.3
-
18
-
-
23044443163
-
Detection of emboli in vessels using electrical impedance measurements-phantom and electrodes
-
Nebuya S, Noshiro M, Brown BH, Smallwood RH, Milnes P. Detection of emboli in vessels using electrical impedance measurements-phantom and electrodes. Physiol Meas 2005; 26: S111-S118.
-
(2005)
Physiol Meas
, vol.26
-
-
Nebuya, S.1
Noshiro, M.2
Brown, B.H.3
Smallwood, R.H.4
Milnes, P.5
-
21
-
-
45749086561
-
Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)
-
Steffen M, Heimann K, Bernstein N, Leonhardt S. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Physiol Meas 2008; 29: 291-306.
-
(2008)
Physiol Meas
, vol.29
, pp. 291-306
-
-
Steffen, M.1
Heimann, K.2
Bernstein, N.3
Leonhardt, S.4
-
22
-
-
77249102472
-
Non-contact monitoring of heart and lung activity by magnetic impedance measurement
-
Nürnberg, Abstract
-
Steffen M, Leonhardt S. Non-contact monitoring of heart and lung activity by magnetic impedance measurement. 26. BTM Konferenz, Nürnberg 2005. Abstract.
-
(2005)
26. BTM Konferenz
-
-
Steffen, M.1
Leonhardt, S.2
-
24
-
-
0014340443
-
Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction
-
Tarjan PP, McFee R. Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction. IEEE Trans Biomed Eng 1968; 15: 266-278.
-
(1968)
IEEE Trans Biomed Eng
, vol.15
, pp. 266-278
-
-
Tarjan, P.P.1
McFee, R.2
-
25
-
-
0034018919
-
Genesis of the normal and the abnormal arterial pulse
-
Vlachopoulos C, O'Rourke M. Genesis of the normal and the abnormal arterial pulse. Curr Probl Cardiol 2000; 25: 303-367.
-
(2000)
Curr Probl Cardiol
, vol.25
, pp. 303-367
-
-
Vlachopoulos, C.1
O'Rourke, M.2
-
26
-
-
0000667178
-
Theoretische Untersuchung der Rückwirkung der Wirbelströme bei kontaktlosen Leitfähigkeitsmessungen
-
Wach P. Theoretische Untersuchung der Rückwirkung der Wirbelströme bei kontaktlosen Leitfähigkeitsmessungen. Elektrotech Maschinenbau 1979; 76: 505-509.
-
(1979)
Elektrotech Maschinenbau
, vol.76
, pp. 505-509
-
-
Wach, P.1
|