메뉴 건너뛰기




Volumn 25, Issue 6, 2012, Pages 873-882

High-resolution mapping of human brain metabolites by free induction decay 1H MRSI at 7T

Author keywords

7T; Brain; Chemical shift imaging; Free induction decay; Glutamate; Neurotransmitter; Spectroscopy

Indexed keywords

7T; CHEMICAL SHIFT IMAGING; FREE INDUCTION DECAY; GLUTAMATE; NEUROTRANSMITTER;

EID: 84860607967     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1805     Document Type: Article
Times cited : (94)

References (40)
  • 1
    • 0034305619 scopus 로고    scopus 로고
    • MR spectroscopy: a powerful tool for investigating brain function and neurological diseases
    • Burlina AP, Aureli T, Bracco F, Conti F, Battistin L. MR spectroscopy: a powerful tool for investigating brain function and neurological diseases. Neurochem. Res. 2000; 25(9): 1365-1372.
    • (2000) Neurochem. Res. , vol.25 , Issue.9 , pp. 1365-1372
    • Burlina, A.P.1    Aureli, T.2    Bracco, F.3    Conti, F.4    Battistin, L.5
  • 2
    • 70349613203 scopus 로고    scopus 로고
    • In vivo H-1 NMR spectroscopy of the human brain at high magnetic fields: metabolite quantification at 4T vs. 7T
    • Tkac I, Oz G, Adriany G, Ugurbil K, Gruetter R. In vivo H-1 NMR spectroscopy of the human brain at high magnetic fields: metabolite quantification at 4T vs. 7T. Magn. Reson. Med. 2009; 62(4): 868-879.
    • (2009) Magn. Reson. Med. , vol.62 , Issue.4 , pp. 868-879
    • Tkac, I.1    Oz, G.2    Adriany, G.3    Ugurbil, K.4    Gruetter, R.5
  • 3
    • 70049090392 scopus 로고    scopus 로고
    • Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for H-1-MRSI of the human brain at 7T with minimal signal loss
    • Henning A, Fuchs A, Murdoch JB, Boesiger P. Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for H-1-MRSI of the human brain at 7T with minimal signal loss. NMR Biomed. 2009; 22(7): 683-696.
    • (2009) NMR Biomed. , vol.22 , Issue.7 , pp. 683-696
    • Henning, A.1    Fuchs, A.2    Murdoch, J.B.3    Boesiger, P.4
  • 7
    • 41849102763 scopus 로고    scopus 로고
    • Towards H-1-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses
    • Scheenen TWJ, Heerschap A, Klomp DWJ. Towards H-1-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses. Magn. Reson. Mater. Phys. Biol. Med. 2008; 21(1-2): 95-101.
    • (2008) Magn. Reson. Mater. Phys. Biol. Med. , vol.21 , Issue.1-2 , pp. 95-101
    • Scheenen, T.W.J.1    Heerschap, A.2    Klomp, D.W.J.3
  • 9
    • 42549105064 scopus 로고    scopus 로고
    • Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for H-1 MRSI at 7T
    • Balchandani P, Pauly J, Spielman D. Interleaved narrow-band PRESS sequence with adiabatic spatial-spectral refocusing pulses for H-1 MRSI at 7T. Magn. Reson. Med. 2008; 59(5): 973-979.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.5 , pp. 973-979
    • Balchandani, P.1    Pauly, J.2    Spielman, D.3
  • 11
    • 42549135002 scopus 로고    scopus 로고
    • Fat suppression for H-1 MRSI at 7T using spectrally selective adiabatic inversion recovery
    • Balchandani P, Spielman D. Fat suppression for H-1 MRSI at 7T using spectrally selective adiabatic inversion recovery. Magn. Reson. Med. 2008; 59(5): 980-988.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.5 , pp. 980-988
    • Balchandani, P.1    Spielman, D.2
  • 12
    • 75749120149 scopus 로고    scopus 로고
    • Field strength dependence of PRESS timings for simultaneous detection of glutamate and glutamine from 1.5 to 7T. J
    • Snyder J, Wilman A. Field strength dependence of PRESS timings for simultaneous detection of glutamate and glutamine from 1.5 to 7T. J. Magn. Reson. 2010; 203(1): 66-72.
    • (2010) Magn. Reson. , vol.203 , Issue.1 , pp. 66-72
    • Snyder, J.1    Wilman, A.2
  • 13
    • 70349616317 scopus 로고    scopus 로고
    • Invivo detection of serine in the human brain by proton magnetic resonance spectroscopy (H-1-MRS) at 7 Tesla
    • Choi CH, Dimitrov I, Douglas D, Zhao CG, Hawesa H, Ghose S, Tamminga CA. Invivo detection of serine in the human brain by proton magnetic resonance spectroscopy (H-1-MRS) at 7 Tesla. Magn. Reson. Med. 2009; 62(4): 1042-1046.
    • (2009) Magn. Reson. Med. , vol.62 , Issue.4 , pp. 1042-1046
    • Choi, C.H.1    Dimitrov, I.2    Douglas, D.3    Zhao, C.G.4    Hawesa, H.5    Ghose, S.6    Tamminga, C.A.7
  • 14
    • 77949697751 scopus 로고    scopus 로고
    • Noninvasive quantification of human brain ascorbate concentration using H-1 NMR spectroscopy at 7T
    • Terpstra M, Ugurbil K, Tkac I. Noninvasive quantification of human brain ascorbate concentration using H-1 NMR spectroscopy at 7T. NMR Biomed. 2010; 23(3): 227-232.
    • (2010) NMR Biomed. , vol.23 , Issue.3 , pp. 227-232
    • Terpstra, M.1    Ugurbil, K.2    Tkac, I.3
  • 15
    • 46749113800 scopus 로고    scopus 로고
    • Introduction to clinical invivo MR spectroscopy
    • Hajek M, Dezortova M. Introduction to clinical invivo MR spectroscopy. Eur. J. Radiol. 2008; 67(2): 185-193.
    • (2008) Eur. J. Radiol. , vol.67 , Issue.2 , pp. 185-193
    • Hajek, M.1    Dezortova, M.2
  • 16
    • 44649118663 scopus 로고    scopus 로고
    • Proton T2 relaxation time of J-coupled cerebral metabolites in rat brain at 9.4T
    • Xin L, Gambarota G, Mlynarik V, Gruetter R. Proton T2 relaxation time of J-coupled cerebral metabolites in rat brain at 9.4T. NMR Biomed. 2008; 21(4): 396-401.
    • (2008) NMR Biomed. , vol.21 , Issue.4 , pp. 396-401
    • Xin, L.1    Gambarota, G.2    Mlynarik, V.3    Gruetter, R.4
  • 17
    • 0032430504 scopus 로고    scopus 로고
    • A method of RF inhomogeneity correction in MR imaging
    • Mihara H, Iriguchi N, Ueno S. A method of RF inhomogeneity correction in MR imaging. MAGMA, 1998; 7(2): 115-120.
    • (1998) MAGMA , vol.7 , Issue.2 , pp. 115-120
    • Mihara, H.1    Iriguchi, N.2    Ueno, S.3
  • 18
    • 0029975951 scopus 로고    scopus 로고
    • Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation
    • Haupt CI, Schuff N, Weiner MW, Maudsley AA. Removal of lipid artifacts in H-1 spectroscopic imaging by data extrapolation. Magn. Reson. Med. 1996; 35(5): 678-687.
    • (1996) Magn. Reson. Med. , vol.35 , Issue.5 , pp. 678-687
    • Haupt, C.I.1    Schuff, N.2    Weiner, M.W.3    Maudsley, A.A.4
  • 19
    • 0028365711 scopus 로고
    • Optimum flip-angles for exciting NMR with uncertain T1 values
    • Bottomley PA, Ouwerkerk R. Optimum flip-angles for exciting NMR with uncertain T1 values. Magn. Reson. Med. 1994; 32(1): 137-141.
    • (1994) Magn. Reson. Med. , vol.32 , Issue.1 , pp. 137-141
    • Bottomley, P.A.1    Ouwerkerk, R.2
  • 22
    • 0036828879 scopus 로고    scopus 로고
    • Fast robust automated brain extraction. 8th Annual Meeting of the Organization for Human Brain Mapping, Sendai, Japan, 143-155
    • Smith SM. Fast robust automated brain extraction. 8th Annual Meeting of the Organization for Human Brain Mapping, Sendai, Japan, 2002; 143-155.
    • (2002)
    • Smith, S.M.1
  • 23
    • 0034959727 scopus 로고    scopus 로고
    • Automatic quantitation of localized invivo H-1 spectra with LCModel
    • Provencher SW. Automatic quantitation of localized invivo H-1 spectra with LCModel. NMR Biomed. 2001; 14(4): 260-264.
    • (2001) NMR Biomed. , vol.14 , Issue.4 , pp. 260-264
    • Provencher, S.W.1
  • 25
    • 0037225769 scopus 로고    scopus 로고
    • Parameterized evaluation of macromolecules and lipids in proton MR spectroscopy of brain diseases
    • Seeger U, Klose U, Mader I, Grodd W, Naegele T. Parameterized evaluation of macromolecules and lipids in proton MR spectroscopy of brain diseases. Magn. Reson. Med. 2003; 49: 19-28.
    • (2003) Magn. Reson. Med. , vol.49 , pp. 19-28
    • Seeger, U.1    Klose, U.2    Mader, I.3    Grodd, W.4    Naegele, T.5
  • 27
    • 84860607957 scopus 로고    scopus 로고
    • MINC 2.0: a modality independent format for multidimensional medical images. 10th Annual Meeting of the Organization for Human Brain Mapping, Budapest, Hungary
    • Vincent RD, Janke A, Sled JG, Baghdadi L, Neelin P, Evans AC. MINC 2.0: a modality independent format for multidimensional medical images. 10th Annual Meeting of the Organization for Human Brain Mapping, Budapest, Hungary, 2004; 323.
    • (2004) , pp. 323
    • Vincent, R.D.1    Janke, A.2    Sled, J.G.3    Baghdadi, L.4    Neelin, P.5    Evans, A.C.6
  • 28
    • 0034875929 scopus 로고    scopus 로고
    • Proton T1 and T2 relaxation times of human brain metabolites at 3 Tesla
    • Mlynarik V, Gruber S, Moser E. Proton T1 and T2 relaxation times of human brain metabolites at 3 Tesla. NMR Biomed. 2001; 14: 325-331.
    • (2001) NMR Biomed. , vol.14 , pp. 325-331
    • Mlynarik, V.1    Gruber, S.2    Moser, E.3
  • 29
    • 0347917092 scopus 로고    scopus 로고
    • Proton T-1 relaxation times of cerebral metabolites differ within and between regions of normal human brain
    • Brief EE, Whittal KP, Li DKB, MacKay A. Proton T-1 relaxation times of cerebral metabolites differ within and between regions of normal human brain. NMR Biomed. 2003; 16(8): 503-509.
    • (2003) NMR Biomed. , vol.16 , Issue.8 , pp. 503-509
    • Brief, E.E.1    Whittal, K.P.2    Li, D.K.B.3    MacKay, A.4
  • 31
    • 33750632039 scopus 로고    scopus 로고
    • Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition
    • Mlynarik V, Gambarota G, Frenkel H, Gruetter R. Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition. Magn. Reson. Med. 2006; 56(5): 965-970.
    • (2006) Magn. Reson. Med. , vol.56 , Issue.5 , pp. 965-970
    • Mlynarik, V.1    Gambarota, G.2    Frenkel, H.3    Gruetter, R.4
  • 32
    • 67049169082 scopus 로고    scopus 로고
    • MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T
    • Mekle R, Mlynarik V, Gambarota G, Hergt M, Krueger G, Gruetter R. MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T. Magn. Reson. Med. 2009; 61(6): 1279-1285.
    • (2009) Magn. Reson. Med. , vol.61 , Issue.6 , pp. 1279-1285
    • Mekle, R.1    Mlynarik, V.2    Gambarota, G.3    Hergt, M.4    Krueger, G.5    Gruetter, R.6
  • 33
    • 77949486359 scopus 로고    scopus 로고
    • Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners
    • Andronesi OC, Ramadan S, Ratai EM, Jennings D, Mountford CE, Sorensen AG. Spectroscopic imaging with improved gradient modulated constant adiabaticity pulses on high-field clinical scanners. J. Magn. Reson. 2010; 203(2): 283-293.
    • (2010) J. Magn. Reson. , vol.203 , Issue.2 , pp. 283-293
    • Andronesi, O.C.1    Ramadan, S.2    Ratai, E.M.3    Jennings, D.4    Mountford, C.E.5    Sorensen, A.G.6
  • 34
    • 22944467236 scopus 로고    scopus 로고
    • Quantitative proton magnetic resonance spectroscopic imaging: regional variations in the corpus callosum and cortical gray matter
    • Degaonkar MN, Pomper MG, Barker PB. Quantitative proton magnetic resonance spectroscopic imaging: regional variations in the corpus callosum and cortical gray matter. J. Magn. Reson. Imaging, 2005; 22: 175-179.
    • (2005) J. Magn. Reson. Imaging , vol.22 , pp. 175-179
    • Degaonkar, M.N.1    Pomper, M.G.2    Barker, P.B.3
  • 36
    • 0037311513 scopus 로고    scopus 로고
    • High-resolution 3D proton spectroscopic imaging of the human brain at 3T: SNR issues and application for anatomy-matched voxel sizes
    • Gruber S, Mlynarik V, Moser E. High-resolution 3D proton spectroscopic imaging of the human brain at 3T: SNR issues and application for anatomy-matched voxel sizes. Magn. Reson. Med. 2003; 49(2): 299-306.
    • (2003) Magn. Reson. Med. , vol.49 , Issue.2 , pp. 299-306
    • Gruber, S.1    Mlynarik, V.2    Moser, E.3
  • 37
    • 0037310854 scopus 로고    scopus 로고
    • Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy
    • Ebel A, Maudsley AA. Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy. Magn. Reson. Imaging, 2003; 21(2): 113-120.
    • (2003) Magn. Reson. Imaging , vol.21 , Issue.2 , pp. 113-120
    • Ebel, A.1    Maudsley, A.A.2
  • 38
    • 84860647190 scopus 로고    scopus 로고
    • The benefits of higher order B0 shimming of the human brain at 7T. Proceedings of the 19th Annual Meeting ISMRM, Stockholm, Sweden
    • Hetherington HP, Lo KM, Punchard W, Starewicz P, Pan JW. The benefits of higher order B0 shimming of the human brain at 7T. Proceedings of the 19th Annual Meeting ISMRM, Stockholm, Sweden, 2010; 932.
    • (2010) , pp. 932
    • Hetherington, H.P.1    Lo, K.M.2    Punchard, W.3    Starewicz, P.4    Pan, J.W.5
  • 39
    • 42549158041 scopus 로고    scopus 로고
    • Accelerated proton echo planar spectroscopic Imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil
    • Tsai SY, Otazo R, Posse S, Lin YR, Chung HW, Wald LL, Wiggins GC, Lin FH. Accelerated proton echo planar spectroscopic Imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil. Magn. Reson. Med. 2008; 59(5): 989-998.
    • (2008) Magn. Reson. Med. , vol.59 , Issue.5 , pp. 989-998
    • Tsai, S.Y.1    Otazo, R.2    Posse, S.3    Lin, Y.R.4    Chung, H.W.5    Wald, L.L.6    Wiggins, G.C.7    Lin, F.H.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.