메뉴 건너뛰기




Volumn 49, Issue 2, 2003, Pages 299-306

High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes

Author keywords

Brain; Brain tumor; High field; Pelizaeus Merzbacher disease; Proton spectroscopic imaging; Segmentation

Indexed keywords

BRAIN; IMAGE RESOLUTION; IMAGE SEGMENTATION; METABOLISM; METABOLITES; TUMORS;

EID: 0037311513     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10377     Document Type: Article
Times cited : (60)

References (30)
  • 3
    • 0029666215 scopus 로고    scopus 로고
    • Intratumoral lipids in 1H MRS in vivo in brain tumors: Experience of Siemens cooperative clinical trial
    • Negendank WG, Sauter R. Intratumoral lipids in 1H MRS in vivo in brain tumors: experience of Siemens cooperative clinical trial. Anticancer Res 1996;16:1533-1538.
    • (1996) Anticancer Res , vol.16 , pp. 1533-1538
    • Negendank, W.G.1    Sauter, R.2
  • 7
    • 12244254280 scopus 로고    scopus 로고
    • Functional metabolic mapping (FMM) - Pushing the limits in high resolution, high field spectroscopic imaging
    • Moser E, Mlynarik V, Gruber S, Gonen O. Functional metabolic mapping (FMM) - pushing the limits in high resolution, high field spectroscopic imaging. Magn Reson Mater Phys Biol Med 2000;11:182.
    • (2000) Magn Reson Mater Phys Biol Med , vol.11 , pp. 182
    • Moser, E.1    Mlynarik, V.2    Gruber, S.3    Gonen, O.4
  • 8
    • 0033938797 scopus 로고    scopus 로고
    • Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging
    • Hanson LG, Adalsteinsson E, Pfefferbaum A, Spielman DM. Optimal voxel size for measuring global gray and white matter proton metabolite concentrations using chemical shift imaging. Magn Reson Med 2000;44:10-18.
    • (2000) Magn Reson Med , vol.44 , pp. 10-18
    • Hanson, L.G.1    Adalsteinsson, E.2    Pfefferbaum, A.3    Spielman, D.M.4
  • 9
    • 0035186045 scopus 로고    scopus 로고
    • SNR versus resolution in 3D 1H MRS of the human brain at high magnetic field
    • Li BSY, Regal J, Gonen O. SNR versus resolution in 3D 1H MRS of the human brain at high magnetic field. Magn Reson Med 2001;46:1049-1053.
    • (2001) Magn Reson Med , vol.46 , pp. 1049-1053
    • Li, B.S.Y.1    Regal, J.2    Gonen, O.3
  • 11
    • 0030905465 scopus 로고    scopus 로고
    • 3D localized in vivo 1H spectrosocopy of human brain using a hybrid of 1D-Hadamard with 2D-chemical shift imaging
    • Gonen O, Arias-Mendoza F, Goelman G. 3D localized in vivo 1H spectrosocopy of human brain using a hybrid of 1D-Hadamard with 2D-chemical shift imaging. Magn Reson Med 1997;37:644-650.
    • (1997) Magn Reson Med , vol.37 , pp. 644-650
    • Gonen, O.1    Arias-Mendoza, F.2    Goelman, G.3
  • 13
    • 0027200329 scopus 로고
    • Automatic, localized in vivo adjustment of all first- and second-order shim coils
    • Gruetter R. Automatic, localized in vivo adjustment of all first- and second-order shim coils, Magn Reson Med 1993;29:804-811.
    • (1993) Magn Reson Med , vol.29 , pp. 804-811
    • Gruetter, R.1
  • 14
    • 0031756714 scopus 로고    scopus 로고
    • Automated spectral analysis. III. Application to in vivo proton MR spectroscopy and spectroscopic imaging
    • Soher BJ, Young K, Govindaraju V, Maudsley AA. Automated spectral analysis. III. application to in vivo proton MR spectroscopy and spectroscopic imaging. Magn Reson Med 1998;40:822-831.
    • (1998) Magn Reson Med , vol.40 , pp. 822-831
    • Soher, B.J.1    Young, K.2    Govindaraju, V.3    Maudsley, A.A.4
  • 15
    • 0034875929 scopus 로고    scopus 로고
    • Proton T1 and T2 relaxation times of brain metabolites at 3 T
    • Mlynarik V, Gruber S, Moser E, Proton T1 and T2 relaxation times of brain metabolites at 3 T. NMR Biomed 2001;14:325-331.
    • (2001) NMR Biomed , vol.14 , pp. 325-331
    • Mlynarik, V.1    Gruber, S.2    Moser, E.3
  • 17
    • 0034904232 scopus 로고    scopus 로고
    • Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors
    • Nelson JS. Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors. Magn Reson Med 2001;46:228-239.
    • (2001) Magn Reson Med , vol.46 , pp. 228-239
    • Nelson, J.S.1
  • 18
    • 0024493728 scopus 로고
    • Localized high-resolution proton NMR spectroscopy using stimulated echoes: Initial applications to human brain in vivo
    • Frahm J, Bruhn H, Gyngell ML, Merboldt KD, Hanicke W, Sauter R. Localized high-resolution proton NMR spectroscopy using stimulated echoes: initial applications to human brain in vivo. Magn Reson Med 1989;9:79-93.
    • (1989) Magn Reson Med , vol.9 , pp. 79-93
    • Frahm, J.1    Bruhn, H.2    Gyngell, M.L.3    Merboldt, K.D.4    Hanicke, W.5    Sauter, R.6
  • 20
    • 0035033720 scopus 로고    scopus 로고
    • Single-voxel proton MRS of the human brain at 1.5T and 3.0T
    • Barker PB, Hearshen DO, Boska MD. Single-voxel proton MRS of the human brain at 1.5T and 3.0T. Magn Reson Med 2001;45:765-769.
    • (2001) Magn Reson Med , vol.45 , pp. 765-769
    • Barker, P.B.1    Hearshen, D.O.2    Boska, M.D.3
  • 21
    • 0034777052 scopus 로고    scopus 로고
    • Multivoxel 3D proton spectroscopy in the brain at 1.5 versus 3 Tesla: A signal to noise and resolution comparison
    • Gonen O, Gruber S, Li BSY, Mlynarik V, Moser E. Multivoxel 3D proton spectroscopy in the brain at 1.5 versus 3 Tesla: a signal to noise and resolution comparison. Am J Neuroradiol 2001;22:1727-1731.
    • (2001) Am J Neuroradiol , vol.22 , pp. 1727-1731
    • Gonen, O.1    Gruber, S.2    Li, B.S.Y.3    Mlynarik, V.4    Moser, E.5
  • 22
    • 0001383542 scopus 로고
    • Selection of optimum parameters for pulse Fourier transform nuclear magnetic resonance
    • Becker ED, Feretti JA, Gambhir PM. Selection of optimum parameters for pulse Fourier transform nuclear magnetic resonance. Anal Chem 1979;51:1413-1420.
    • (1979) Anal Chem , vol.51 , pp. 1413-1420
    • Becker, E.D.1    Feretti, J.A.2    Gambhir, P.M.3
  • 23
    • 0028541189 scopus 로고
    • Sensitivity optimization of echo times and data sampling times for spin-echo spectroscopy
    • Johnson G, Wu EX. Sensitivity optimization of echo times and data sampling times for spin-echo spectroscopy. J Magn Reson B 1994;105:238-241.
    • (1994) J Magn Reson B , vol.105 , pp. 238-241
    • Johnson, G.1    Wu, E.X.2
  • 25
    • 0034963583 scopus 로고    scopus 로고
    • MR spectroscopy quantitation: A review of time-domain methods
    • Vanhamme L, Sundin T, Hecke PV, Huffel SV. MR spectroscopy quantitation: a review of time-domain methods. NMR Biomed 2001;14:233-246.
    • (2001) NMR Biomed , vol.14 , pp. 233-246
    • Vanhamme, L.1    Sundin, T.2    Hecke, P.V.3    Huffel, S.V.4
  • 27
    • 0033812216 scopus 로고    scopus 로고
    • Quantitative analysis of short echo time 1H-MRSI of cerebral gray and white matter
    • McLean M, Woermann FG, Barker GJ, Duncan JS. Quantitative analysis of short echo time 1H-MRSI of cerebral gray and white matter. Magn Reson Med 2000;44:401-411.
    • (2000) Magn Reson Med , vol.44 , pp. 401-411
    • McLean, M.1    Woermann, F.G.2    Barker, G.J.3    Duncan, J.S.4
  • 29
    • 0032826594 scopus 로고    scopus 로고
    • Voxel-by-voxel comparison of automatically segmented cerebral gray matter - A rater-independent comparison of structural MRI in patients with epilepsy
    • Woermann FG, Free SL, Koepp MJ, Ashburner J, Duncan JS. Voxel-by-voxel comparison of automatically segmented cerebral gray matter - a rater-independent comparison of structural MRI in patients with epilepsy. Neuroimage 1999;10:373-384.
    • (1999) Neuroimage , vol.10 , pp. 373-384
    • Woermann, F.G.1    Free, S.L.2    Koepp, M.J.3    Ashburner, J.4    Duncan, J.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.