메뉴 건너뛰기




Volumn 72, Issue 2, 2012, Pages

Potential of polymethylmethacrylate cement-augmented helical proximal femoral nail antirotation blades to improve implant stability - A biomechanical investigation in human cadaveric femoral heads

Author keywords

Cadaveric study; Cement augmentation; Cut out; Helical blade; Intertrochanteric hip fracture

Indexed keywords

POLY(METHYL METHACRYLATE); BONE CEMENT;

EID: 84860554994     PISSN: 21630755     EISSN: 21630763     Source Type: Journal    
DOI: 10.1097/TA.0b013e31821852ed     Document Type: Article
Times cited : (50)

References (25)
  • 1
    • 0033034509 scopus 로고    scopus 로고
    • The AO/ASIF-proximal femoral nail (PFN): A new device for the treatment of unstable proximal femoral fractures
    • Simmermacher RK, Bosch AM, Van der Werken C. The AO/ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fractures. Injury. 1999;30:327-332.
    • (1999) Injury , vol.30 , pp. 327-332
    • Simmermacher, R.K.1    Bosch, A.M.2    Van Der Werken, C.3
  • 2
    • 1642463504 scopus 로고    scopus 로고
    • Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail
    • Schipper IB, Steyerberg EW, Castelein RM, et al. Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail. J Bone Joint Surg Br. 2004;86:86-94.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 86-94
    • Schipper, I.B.1    Steyerberg, E.W.2    Castelein, R.M.3
  • 4
    • 62549086509 scopus 로고    scopus 로고
    • The AO/ASIF proximal femoral nail antirotation (PFNA): A new design for the treatment of unstable proximal femoral fractures
    • Mereddy P, Kamath S, Ramakrishnan M, Malik H, Donnachie N. The AO/ASIF proximal femoral nail antirotation (PFNA): a new design for the treatment of unstable proximal femoral fractures. Injury. 2009;40: 428-432.
    • (2009) Injury , vol.40 , pp. 428-432
    • Mereddy, P.1    Kamath, S.2    Ramakrishnan, M.3    Malik, H.4    Donnachie, N.5
  • 5
    • 0030720275 scopus 로고    scopus 로고
    • Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip
    • Baumgaertner MR, Solberg BD. Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br. 1997;79:969-971.
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 969-971
    • Baumgaertner, M.R.1    Solberg, B.D.2
  • 6
    • 0029012764 scopus 로고
    • The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058-1064.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3    Keggi, J.M.4
  • 8
    • 0027347366 scopus 로고
    • Healing complications after internal fixation of trochanteric hip fractures: The prognostic value of osteoporosis
    • Barrios C, Brostrom LA, Stark A, Walheim G. Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma. 1993;7:438-442.
    • (1993) J Orthop Trauma , vol.7 , pp. 438-442
    • Barrios, C.1    Brostrom, L.A.2    Stark, A.3    Walheim, G.4
  • 9
    • 56349136384 scopus 로고    scopus 로고
    • Osteoporosis and osteoporotic fracture occurrence and prevention in the elderly: A geriatric perspective
    • Boonen S, Dejaeger E, Vanderschueren D, et al. Osteoporosis and osteoporotic fracture occurrence and prevention in the elderly: a geriatric perspective. Best Pract Res Clin Endocrinol Metab. 2008;22:765-785.
    • (2008) Best Pract Res Clin Endocrinol Metab , vol.22 , pp. 765-785
    • Boonen, S.1    Dejaeger, E.2    Vanderschueren, D.3
  • 10
    • 0036096934 scopus 로고    scopus 로고
    • A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures
    • Augat P, Rapp S, Claes L. A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma. 2002;16:311-316.
    • (2002) J Orthop Trauma , vol.16 , pp. 311-316
    • Augat, P.1    Rapp, S.2    Claes, L.3
  • 11
    • 33845905793 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures
    • von der Linden P, Gisep A, Boner V, Windolf M, Appelt A, Suhm N. Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures. J Orthop Res. 2006;24:2230-2237.
    • (2006) J Orthop Res , vol.24 , pp. 2230-2237
    • Von Der Linden, P.1    Gisep, A.2    Boner, V.3    Windolf, M.4    Appelt, A.5    Suhm, N.6
  • 12
    • 84864542315 scopus 로고    scopus 로고
    • The utilization of clinical CT scanning as a qualitative tool in preoperative planning of fracture treatment in the future. An Autopsy Study
    • Singh G, Høiseth A, Eckhardt C, Strømsøe K, Linke B. The utilization of clinical CT scanning as a qualitative tool in preoperative planning of fracture treatment in the future. An Autopsy Study. Høstmøtet Norsk Kirurgisk Forening Oslo. 2005;81.
    • (2005) Høstmøtet Norsk Kirurgisk Forening Oslo , vol.81
    • Singh, G.1    Høiseth, A.2    Eckhardt, C.3    Strømsøe, K.4    Linke, B.5
  • 13
    • 4043145938 scopus 로고    scopus 로고
    • A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation
    • Sommers MB, Roth C, Hall H, et al. A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma. 2004;18:361-368.
    • (2004) J Orthop Trauma , vol.18 , pp. 361-368
    • Sommers, M.B.1    Roth, C.2    Hall, H.3
  • 14
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859-871.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 16
    • 0021885570 scopus 로고
    • The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis
    • Bartucci EJ, Gonzalez MH, Cooperman DR, Freedberg HI, Barmada R, Laros GS. The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis. J Bone Joint Surg Am. 1985;67:1094-1107.
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 1094-1107
    • Bartucci, E.J.1    Gonzalez, M.H.2    Cooperman, D.R.3    Freedberg, H.I.4    Barmada, R.5    Laros, G.S.6
  • 17
    • 57349085028 scopus 로고    scopus 로고
    • Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation
    • Windolf M, Braunstein V, Dutoit C, Schwieger K. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon). 2009;24:59-64.
    • (2009) Clin Biomech (Bristol, Avon) , vol.24 , pp. 59-64
    • Windolf, M.1    Braunstein, V.2    Dutoit, C.3    Schwieger, K.4
  • 18
    • 34547101245 scopus 로고    scopus 로고
    • Mechanical torque measurement predicts load to implant cut-out: A biomechanical study investigating DHS anchorage in femoral heads
    • Suhm N, Hengg C, Schwyn R, Windolf M, Quarz V, Hanni M. Mechanical torque measurement predicts load to implant cut-out: a biomechanical study investigating DHS anchorage in femoral heads. Arch Orthop Trauma Surg. 2007;127:469-474.
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 469-474
    • Suhm, N.1    Hengg, C.2    Schwyn, R.3    Windolf, M.4    Quarz, V.5    Hanni, M.6
  • 19
    • 84655173729 scopus 로고    scopus 로고
    • A medium viscous acrylic cement enhances uniformity of cement filling and reduce leakage in cancellous bone augmentation
    • In press
    • Boger A, Wheeler K. A medium viscous acrylic cement enhances uniformity of cement filling and reduce leakage in cancellous bone augmentation. Spine. In press.
    • Spine
    • Boger, A.1    Wheeler, K.2
  • 20
    • 0024364323 scopus 로고
    • Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures
    • Cheng CL, Chow SP, Pun WK, Leong JC. Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures. Injury. 1989;20:134-138.
    • (1989) Injury , vol.20 , pp. 134-138
    • Cheng, C.L.1    Chow, S.P.2    Pun, W.K.3    Leong, J.C.4
  • 21
    • 0016804873 scopus 로고
    • The use of methylmethacrylate as an adjunct in the internal fixation of unstable comminuted intertrochanteric fractures in osteoporotic patients
    • Harrington KD. The use of methylmethacrylate as an adjunct in the internal fixation of unstable comminuted intertrochanteric fractures in osteoporotic patients. J Bone Joint Surg Am. 1975;57:744-750.
    • (1975) J Bone Joint Surg Am , vol.57 , pp. 744-750
    • Harrington, K.D.1
  • 22
    • 1042267309 scopus 로고    scopus 로고
    • Vertebroplasty in severe osteoporosis. Technique and experience with multi-segment injection
    • Heini PF, Orler R. [Vertebroplasty in severe osteoporosis. Technique and experience with multi-segment injection]. Orthopade. 2004;33: 22-30.
    • (2004) Orthopade , vol.33 , pp. 22-30
    • Heini, P.F.1    Orler, R.2
  • 23
    • 67749148278 scopus 로고    scopus 로고
    • Temperature evaluation during PMMA screw augmentation in osteoporotic bone - An in vitro study about the risk of thermal necrosis in human femoral heads
    • Boner V, Kuhn P, Mendel T, Gisep A. Temperature evaluation during PMMA screw augmentation in osteoporotic bone - an in vitro study about the risk of thermal necrosis in human femoral heads. J Biomed Mater Res B Appl Biomater. 2009;90:842-848.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.90 , pp. 842-848
    • Boner, V.1    Kuhn, P.2    Mendel, T.3    Gisep, A.4
  • 25
    • 0031924185 scopus 로고    scopus 로고
    • Norian SRS cement augmentation in hip fracture treatment. Laboratory and initial clinical results
    • Goodman SB, Bauer TW, Carter D, et al. Norian SRS cement augmentation in hip fracture treatment. Laboratory and initial clinical results. Clin Orthop Relat Res. 1998;348:42-50.
    • (1998) Clin Orthop Relat Res , vol.348 , pp. 42-50
    • Goodman, S.B.1    Bauer, T.W.2    Carter, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.