Phantom studies using a high-resolution CT for Ex-Vivo imaging of degradable magnesium implants and simulated peri-implant bone formation in rabbit tibiae;Phantomuntersuchungen an einem hochauflösenden CT zur Ex-vivo-Darstellung von degradierbaren Magnesiumimplantaten und simulierten periimplantären Knochenschichten in Kaninchentibiae

Author keywords

bones; CT high resolution; degradable magnesium implants, physics

Indexed keywords

ALLOY; MAGNESIUM;

EID: 84860551051     PISSN: 14389029     EISSN: 14389010     Source Type: Journal    
DOI: 10.1055/s-0031-1299293     Document Type: Article
Times cited : (3)

References (26)
  • 1
    • 78651105023 scopus 로고    scopus 로고
    • Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid
    • Bobby Kannan M, Singh Raman RK, Witte F et al. Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid. J Biomed Mater Res B Appl Biomater: 2011; 96 303 309
    • (2011) J Biomed Mater Res B Appl Biomater , vol.96 , pp. 303-309
    • Bobby Kannan, M.1    Singh Raman, R.K.2    Witte, F.3
  • 2
    • 0037421542 scopus 로고    scopus 로고
    • Chemistry and biochemistry of magnesium
    • DOI 10.1016/S0098-2997(02)00087-0, PII S0098299702000870
    • Wolf FI, Cittadini A. Chemistry and biochemistry of magnesium. Mol Aspects Med: 2003; 24 3 9 (Pubitemid 36092140)
    • (2003) Molecular Aspects of Medicine , vol.24 , Issue.1-3 , pp. 3-9
    • Wolf, F.I.1    Cittadini, A.2
  • 3
    • 33847621267 scopus 로고    scopus 로고
    • Control of biodegradation of biocompatable magnesium alloys
    • DOI 10.1016/j.corsci.2007.01.001, PII S0010938X07000029
    • Song G. Control of biodegradation of biocompatable magnesium alloys. Corrosion Sci: 2007; 49 1696 1701 (Pubitemid 46365679)
    • (2007) Corrosion Science , vol.49 , Issue.4 , pp. 1696-1701
    • Song, G.1
  • 6
    • 40649099051 scopus 로고    scopus 로고
    • In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid
    • Bobby Kannan M, Singh Raman RK. In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid. Biomaterials: 2008; 29 2306 2314
    • (2008) Biomaterials , vol.29 , pp. 2306-2314
    • Bobby Kannan, M.1    Singh Raman, R.K.2
  • 7
    • 75849153973 scopus 로고    scopus 로고
    • Comparison of the cross sectional area, the loss in volume and the mechanical properties of LAE442 and MgCa0.8 as resorbable magnesium alloy implants after 12 months implantation duration
    • Thomann M, von der Höh N, Bormann D et al. Comparison of the cross sectional area, the loss in volume and the mechanical properties of LAE442 and MgCa0.8 as resorbable magnesium alloy implants after 12 months implantation duration. Mater Sci Forum: 2010; 638-642 675 680
    • (2010) Mater Sci Forum , vol.638-642 - , pp. 675-680
    • Thomann, M.1    Von Der Höh, N.2    Bormann, D.3
  • 8
    • 62549089681 scopus 로고    scopus 로고
    • Comparison of the resorbable magnesium alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone-implant-contact after 12 months implantation duration in a rabbit model
    • Thomann M, Krause C, Bormann D et al. Comparison of the resorbable magnesium alloys LAE442 und MgCa0.8 concerning their mechanical properties, their progress of degradation and the bone-implant-contact after 12 months implantation duration in a rabbit model. Mat-wiss u Werkstofftech: 2009; 40 82 87
    • (2009) Mat-wiss U Werkstofftech , vol.40 , pp. 82-87
    • Thomann, M.1    Krause, C.2    Bormann, D.3
  • 9
    • 77951521928 scopus 로고    scopus 로고
    • Influence of a magnesium-fluoride coating of magnesium-based implants (MgCa0.8) on degradation in a rabbit model
    • Thomann M, Krause C, Angrisani N et al. Influence of a magnesium-fluoride coating of magnesium-based implants (MgCa0.8) on degradation in a rabbit model. J Biomed Mater Res A: 2010; 93 1609 1619
    • (2010) J Biomed Mater Res A , vol.93 , pp. 1609-1619
    • Thomann, M.1    Krause, C.2    Angrisani, N.3
  • 10
    • 77951577097 scopus 로고    scopus 로고
    • Aktueller Stand der Mikro-CT in der experimentellen Kleintierbildgebung
    • Bag S, Schambach SJ, Bol H et al. Aktueller Stand der Mikro-CT in der experimentellen Kleintierbildgebung. Fortschr Röntgenstr: 2010; 182 390 403
    • (2010) Fortschr Röntgenstr , vol.182 , pp. 390-403
    • Bag, S.1    Schambach, S.J.2    Bol, H.3
  • 11
    • 0036680539 scopus 로고    scopus 로고
    • Micro-CT in small animal and specimen imaging
    • DOI 10.1016/S0167-7799(02)02004-8, PII S0167779902020048
    • Holdsworth DW, Thornton MM. Micro-CT in small animal and specimen imaging. Trends in Biotechnology: 2002; 20 S34 S39 (Pubitemid 34804433)
    • (2002) Trends in Biotechnology , vol.20 , Issue.8
    • Holdsworth, D.W.1    Thornton, M.M.2
  • 12
    • 33847411919 scopus 로고    scopus 로고
    • Small animal absorbed radiation dose from serial micro-computed tomography imaging
    • DOI 10.1007/s11307-007-0080-9
    • Carlson SK, Classic KL, Bender CE et al. Small animal absorbed radiation dose from serial micro-computed tomography imaging. Mol Imaging Biol: 2007; 9 78 82 (Pubitemid 46336222)
    • (2007) Molecular Imaging and Biology , vol.9 , Issue.2 , pp. 78-82
    • Carlson, S.K.1    Classic, K.L.2    Bender, C.E.3    Russell, S.J.4
  • 14
    • 79952992757 scopus 로고    scopus 로고
    • A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use
    • Watanabe H, Honda E, Tetsumura A et al. A comparative study for spatial resolution and subjective image characteristics of a multi-slice CT and a cone-beam CT for dental use. Eur J Radiol: 2011; 3 397 402
    • (2011) Eur J Radiol , vol.3 , pp. 397-402
    • Watanabe, H.1    Honda, E.2    Tetsumura, A.3
  • 15
    • 34247576345 scopus 로고    scopus 로고
    • Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT
    • DOI 10.1118/1.2722872
    • Flohr TG, Stierstorfer K, Süss C et al. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT. Med Phys: 2007; 34 1712 1723 (Pubitemid 46669166)
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1712-1723
    • Flohr, T.G.1    Stierstorfer, K.2    Suss, C.3    Schmidt, B.4    Primak, A.N.5    McCollough, C.H.6
  • 17
    • 43149083839 scopus 로고    scopus 로고
    • Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    • MacNeil JA, Boyd SK. Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys: 2008; 30 792 799
    • (2008) Med Eng Phys , vol.30 , pp. 792-799
    • MacNeil, J.A.1    Boyd, S.K.2
  • 19
    • 84860570961 scopus 로고    scopus 로고
    • Comparison of the biomechanical properties of the magnesium alloys ZEK100, AX30, LAE442 and MgCa08 after 3 and 6 months implantation in rabbit tibiae
    • Abstract 140; CD-ROM
    • Hühnerschulte A, Krause A, Krause C et al. Comparison of the biomechanical properties of the magnesium alloys ZEK100, AX30, LAE442 and MgCa08 after 3 and 6 months implantation in rabbit tibiae. Abstr 22nd Eur Conf Biomater: 2009; Abstract 140; CD-ROM
    • (2009) Abstr 22nd Eur Conf Biomater
    • Hühnerschulte, A.1    Krause, A.2    Krause, C.3
  • 20
    • 76649119773 scopus 로고    scopus 로고
    • Degradation behaviour and mechanical properties of magnesium implants in rabbit tibiae
    • Krause A, von der Höh N, Bormann D et al. Degradation behaviour and mechanical properties of magnesium implants in rabbit tibiae. J Mater Sci: 2010; 45 624 632
    • (2010) J Mater Sci , vol.45 , pp. 624-632
    • Krause, A.1    Von Der Höh, N.2    Bormann, D.3
  • 22
    • 79960091566 scopus 로고    scopus 로고
    • Phantom and cadaver measurements of dose and dose distribution in micro-CT of the chest in mice
    • Rodt T, Lüpke M, Boehm C et al. Phantom and cadaver measurements of dose and dose distribution in micro-CT of the chest in mice. Acta Radiologica: 2011; 52 75 80
    • (2011) Acta Radiologica , vol.52 , pp. 75-80
    • Rodt, T.1    Lüpke, M.2    Boehm, C.3
  • 23
    • 84860594553 scopus 로고
    • Leitlinien der Bundesärztekammer zur Qualitätssicherung in der Computertomographie
    • Bundesärztekammer
    • Bundesärztekammer Leitlinien der Bundesärztekammer zur Qualitätssicherung in der Computertomographie. Dtsch Ärztebl: 1992; 89 1 35
    • (1992) Dtsch Ärztebl , vol.89 , pp. 1-35
  • 24
    • 42449123153 scopus 로고    scopus 로고
    • Effect of age on bone mineral density and micro architecture in the radius and tibia of horses: An Xtreme computed tomographic study
    • Fürst A, Meier D, Michel S et al. Effect of age on bone mineral density and micro architecture in the radius and tibia of horses: an Xtreme computed tomographic study. BMC Vet Res: 2008; 4 1 12
    • (2008) BMC Vet Res , vol.4 , pp. 1-12
    • Fürst, A.1    Meier, D.2    Michel, S.3
  • 25
    • 34250018006 scopus 로고    scopus 로고
    • Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    • DOI 10.1016/j.medengphy.2006.11.002, PII S1350453306002335
    • MacNeil JA, Boyd SK. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Med Eng Phys: 2007; 29 1096 1105 (Pubitemid 350052626)
    • (2007) Medical Engineering and Physics , vol.29 , Issue.10 , pp. 1096-1105
    • MacNeil, J.A.1    Boyd, S.K.2
  • 26
    • 70350247738 scopus 로고    scopus 로고
    • Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone
    • Tami AE, Leitner MM, Baucke MG et al. Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone. Bone: 2009; 45 1117 1124
    • (2009) Bone , vol.45 , pp. 1117-1124
    • Tami, A.E.1    Leitner, M.M.2    Baucke, M.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.