메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 235-243

Evaluation of Quadrox-i and Capiox FX neonatal oxygenators with integrated arterial filters in eliminating gaseous microemboli and retaining hemodynamic properties during simulated cardiopulmonary bypass

Author keywords

cardiopulmonary bypass; emboli; hemodynamics; oxygenator with integrated filter; pediatric; purge line flow

Indexed keywords

OXYGEN;

EID: 84860428863     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659112438932     Document Type: Article
Times cited : (28)

References (12)
  • 1
    • 51149120650 scopus 로고    scopus 로고
    • "Stolen" blood flow: Effect of an open arterial filter purge line in a simulated neonatal CPB model
    • Wang S, Miller A, Myers JL, Ündar A. "Stolen" blood flow: effect of an open arterial filter purge line in a simulated neonatal CPB model. ASAIO J. 2008 ; 54: 432-435
    • (2008) ASAIO J , vol.54 , pp. 432-435
    • Wang, S.1    Miller, A.2    Myers, J.L.3    Ündar, A.4
  • 2
    • 77950906582 scopus 로고    scopus 로고
    • Brain protection during pediatric cardiopulmonary bypass
    • Su XW, Ündar A. Brain protection during pediatric cardiopulmonary bypass. Artificial Organs. 2010 ; 34: 91-102
    • (2010) Artificial Organs , vol.34 , pp. 91-102
    • Su, X.W.1    Ündar, A.2
  • 3
    • 77949653088 scopus 로고    scopus 로고
    • Transcranial Doppler ultrasonography: A reliable method of monitoring pulsatile flow during cardiopulmonary bypass in infants and young children
    • Rogerson A, Guan Y, Kimatian S, et al. Transcranial Doppler ultrasonography: a reliable method of monitoring pulsatile flow during cardiopulmonary bypass in infants and young children. J Thorac Cardiovasc Surg. 2010 ; 139: e80-82
    • (2010) J Thorac Cardiovasc Surg , vol.139 , pp. 80-82
    • Rogerson, A.1    Guan, Y.2    Kimatian, S.3
  • 5
    • 70450280524 scopus 로고    scopus 로고
    • Clinical real-time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass
    • Wang S, Woitas K, Clark JB, Myers JL, Ündar A. Clinical real-time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass. Artificial Organs. 2009 ; 33 (11). 1026-1030
    • (2009) Artificial Organs , vol.33 , Issue.11 , pp. 1026-1030
    • Wang, S.1    Woitas, K.2    Clark, J.B.3    Myers, J.L.4    Ündar, A.5
  • 6
    • 78649638010 scopus 로고    scopus 로고
    • Evaluation of Quadrox-i neonatal oxygenator with an integrated arterial filter
    • Salvitabar A, Qiu F, Kunselman A, Ündar A. Evaluation of Quadrox-i neonatal oxygenator with an integrated arterial filter. Perfusion. 2010 ; 25 (6). 409-415
    • (2010) Perfusion , vol.25 , Issue.6 , pp. 409-415
    • Salvitabar, A.1    Qiu, F.2    Kunselman, A.3    Ündar, A.4
  • 7
    • 78649576964 scopus 로고    scopus 로고
    • Evaluation of Capiox FX05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line
    • Qiu F, Peng S, Kunselman A, Ündar A. Evaluation of Capiox FX05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line. Artificial Organs. 2010 ; 34 (11). 1053-1057
    • (2010) Artificial Organs , vol.34 , Issue.11 , pp. 1053-1057
    • Qiu, F.1    Peng, S.2    Kunselman, A.3    Ündar, A.4
  • 8
    • 34548834165 scopus 로고    scopus 로고
    • Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter
    • Lynch JE, Pouch A, Sanders R, Hinders M, Rudd K, Sevick J. Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter. Ultrasound in Med & Biol. 2007 ; 33 (10). 1661-1675
    • (2007) Ultrasound in Med & Biol , vol.33 , Issue.10 , pp. 1661-1675
    • Lynch, J.E.1    Pouch, A.2    Sanders, R.3    Hinders, M.4    Rudd, K.5    Sevick, J.6
  • 10
    • 84860444337 scopus 로고    scopus 로고
    • Evaluation of three hollow-fiber membrane oxygenators without integrated arterial filters for neonatal cardiopulmonary bypass
    • Dogal NM, Mathis RK, Lin J, Qiu F, Kunselman A, Ündar A. Evaluation of three hollow-fiber membrane oxygenators without integrated arterial filters for neonatal cardiopulmonary bypass. Perfusion. 2011 ;:
    • (2011) Perfusion
    • Dogal, N.M.1    Mathis, R.K.2    Lin, J.3    Qiu, F.4    Kunselman, A.5    Ündar, A.6
  • 11
    • 70450250005 scopus 로고    scopus 로고
    • Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops
    • Guan Y, Palanzo D, Kunselman A, Ündar A. Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops. Artificial Organs. 2009 ; 33 (11). 1037-1043
    • (2009) Artificial Organs , vol.33 , Issue.11 , pp. 1037-1043
    • Guan, Y.1    Palanzo, D.2    Kunselman, A.3    Ündar, A.4
  • 12
    • 68549125270 scopus 로고    scopus 로고
    • Quantification of pressure-flow waveforms and selection of components for the pulsatile extracorporeal circuit
    • Wang S, Haines N, Undar A. Quantification of pressure-flow waveforms and selection of components for the pulsatile extracorporeal circuit. J Extracorpor Technol. 2009 ; 41 (1). 20-25
    • (2009) J Extracorpor Technol , vol.41 , Issue.1 , pp. 20-25
    • Wang, S.1    Haines, N.2    Undar, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.