메뉴 건너뛰기




Volumn 8313, Issue , 2012, Pages

Reduced memory augmented Lagrangian algorithm for 3D iterative X-ray CT image reconstruction

Author keywords

[No Author keywords available]

Indexed keywords

ALTERNATING DIRECTION METHODS; AUGMENTED LAGRANGIAN ALGORITHM; AUGMENTED LAGRANGIAN METHODS; AUXILIARY VARIABLES; COMPUTATION TIME; DEBLURRING; EDGE PRESERVING; HELICAL CT; MEMORY REQUIREMENTS; NON-SMOOTH; NUMERICAL RESULTS; PATIENT DOSE; REDUCED MEMORY; REDUCED MEMORY REQUIREMENTS; ROUGHNESS PENALTY; STATISTICAL IMAGE RECONSTRUCTION; TOTAL VARIATION; VARIABLE SPLITTING; WEIGHTED LEAST-SQUARES; X-RAY CT;

EID: 84860385770     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.910941     Document Type: Conference Paper
Times cited : (10)

References (11)
  • 1
    • 79951838072 scopus 로고    scopus 로고
    • An augmented Lagrangian approach to the constrained optimization formulation of imaging inverse problems
    • M. V. Afonso, J. M. Bioucas-Dias, and M. A. T. Figueiredo. An augmented Lagrangian approach to the constrained optimization formulation of imaging inverse problems. IEEE Trans. Im. Proc., 20(3):681-695, 2011.
    • (2011) IEEE Trans. Im. Proc. , vol.20 , Issue.3 , pp. 681-695
    • Afonso, M.V.1    Bioucas-Dias, J.M.2    Figueiredo, M.A.T.3
  • 2
    • 0027568637 scopus 로고
    • Preconditioning methods for improved convergence rates in iterative reconstructions
    • March
    • N. H. Clinthorne, T. S. Pan, P. C. Chiao, W. L. Rogers, and J. A. Stamos. Preconditioning methods for improved convergence rates in iterative reconstructions. IEEE Trans. Med. Imag., 12(1):78-83, March 1993.
    • (1993) IEEE Trans. Med. Imag. , vol.12 , Issue.1 , pp. 78-83
    • Clinthorne, N.H.1    Pan, T.S.2    Chiao, P.C.3    Rogers, W.L.4    Stamos, J.A.5
  • 3
    • 0027113845 scopus 로고
    • On the Douglas-Rachford splitting method and the proximal point algorithm for maximal monotone operators
    • Jonathan Eckstein and Dimitri P. Bertsekas. On the Douglas-Rachford splitting method and the proximal point algorithm for maximal monotone operators. Mathematical Programming, 55:293-318, 1992.
    • (1992) Mathematical Programming , vol.55 , pp. 293-318
    • Eckstein, J.1    Bertsekas, D.P.2
  • 4
    • 0032655433 scopus 로고    scopus 로고
    • Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction
    • May
    • J. A. Fessler and S. D. Booth. Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction. IEEE Trans. Im. Proc., 8(5):688-99, May 1999.
    • (1999) IEEE Trans. Im. Proc. , vol.8 , Issue.5 , pp. 688-699
    • Fessler, J.A.1    Booth, S.D.2
  • 6
    • 84969334819 scopus 로고    scopus 로고
    • The split Bregman method for L1-regularized problems
    • T. Goldstein and S. Osher. The split Bregman method for L1-regularized problems. SIAM J. Imaging Sci., 2(2):323-43, 2009.
    • (2009) SIAM J. Imaging Sci. , vol.2 , Issue.2 , pp. 323-343
    • Goldstein, T.1    Osher, S.2
  • 8
    • 79952179788 scopus 로고    scopus 로고
    • Parallel MR image reconstruction using augmented Lagrangian methods
    • March
    • S. Ramani and J. A. Fessler. Parallel MR image reconstruction using augmented Lagrangian methods. IEEE Trans. Med. Imag., 30(3):694-706, March 2011.
    • (2011) IEEE Trans. Med. Imag. , vol.30 , Issue.3 , pp. 694-706
    • Ramani, S.1    Fessler, J.A.2
  • 9
    • 84857941126 scopus 로고    scopus 로고
    • A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction
    • To appear
    • S. Ramani and J. A. Fessler. A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction. IEEE Trans. Med. Imag., 2012. To appear.
    • (2012) IEEE Trans. Med. Imag.
    • Ramani, S.1    Fessler, J.A.2
  • 10
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • J-B. Thibault, K. Sauer, C. Bouman, and J. Hsieh. A three-dimensional statistical approach to improved image quality for multi-slice helical CT. Med. Phys., 34(11):4526-44, November 2007. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 11
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • DOI 10.1109/TMI.2006.882141
    • J. Wang, T. Li, H. Lu, and Z. Liang. Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography. IEEE Trans. Med. Imag., 25(10):1272-83, October 2006. (Pubitemid 46417077)
    • (2006) IEEE Transactions on Medical Imaging , vol.25 , Issue.10 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.