메뉴 건너뛰기




Volumn 8313, Issue , 2012, Pages

Detection performance study for cone-beam differential phase contrast CT

Author keywords

Noise power spectrum; Phase contrast; ROC

Indexed keywords

3-D IMAGE; CLINICAL PRACTICES; COMPUTED TOMOGRAPHY; CONE BEAM; CONTRAST TO NOISE RATIO; DETECTABILITY; DETECTION PERFORMANCE; DIAGNOSTIC CAPABILITIES; DIFFERENTIAL PHASE CONTRAST; HUMAN OBSERVERS; HUMAN VISUAL PERCEPTION; LOW CONTRAST; NOISE POWER SPECTRUM; NOISE TEXTURE; PHASE CONTRASTS; ROC; ROC ANALYSIS; SAGITTAL PLANE; X-RAY PHASE;

EID: 84860372392     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.911593     Document Type: Conference Paper
Times cited : (8)

References (14)
  • 1
    • 84860363962 scopus 로고    scopus 로고
    • Multicontrast cone beam CT imaging using a Talbot-Lau interferometer
    • J. Zambelli, N. Bevins, Z. Qi, K. Li, and G.-H. Chen, "Multicontrast cone beam CT imaging using a Talbot-Lau interferometer," RSNA, 2010.
    • (2010) RSNA
    • Zambelli, J.1    Bevins, N.2    Qi, Z.3    Li, K.4    Chen, G.-H.5
  • 2
    • 0023196389 scopus 로고
    • X-ray characterisation of normal and neoplastic breast tissues
    • P. Johns and M. Yaffe, "X-ray characterisation of normal and neoplastic breast tissues," Phys. Med. Biol. 32, p. 675, 1987.
    • (1987) Phys. Med. Biol. , vol.32 , pp. 675
    • Johns, P.1    Yaffe, M.2
  • 3
    • 77953524810 scopus 로고    scopus 로고
    • Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT
    • J. Zambelli, N. Bevins, Z. Qi, and G.-H. Chen, "Radiation dose efficiency comparison between differential phase contrast CT and conventional absorption CT," Med. Phys. 37, pp. 2473-2479, 2010.
    • (2010) Med. Phys. , vol.37 , pp. 2473-2479
    • Zambelli, J.1    Bevins, N.2    Qi, Z.3    Chen, G.-H.4
  • 4
    • 79952982338 scopus 로고    scopus 로고
    • Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography
    • R. Raupach and T. Flohr, "Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography," Phys. Med. Biol. 56, p. 2219, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 2219
    • Raupach, R.1    Flohr, T.2
  • 5
    • 0018733995 scopus 로고
    • Detectability in computed tomographic images
    • K. Hanson, "Detectability in computed tomographic images," Med. Phys 6(5), pp. 441-451, 1979.
    • (1979) Med. Phys , vol.6 , Issue.5 , pp. 441-451
    • Hanson, K.1
  • 9
    • 33645524546 scopus 로고    scopus 로고
    • A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging
    • X. Gong, S. Glick, B. Liu, A. Vedula, and S. Thacker, "A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging,"Med. Phys. 33, p. 1041, 2006.
    • (2006) Med. Phys. , vol.33 , pp. 1041
    • Gong, X.1    Glick, S.2    Liu, B.3    Vedula, A.4    Thacker, S.5
  • 10
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • C. Metz, "ROC methodology in radiologic imaging," Invest. Radiol. 21(9), p. 720, 1986.
    • (1986) Invest. Radiol. , vol.21 , Issue.9 , pp. 720
    • Metz, C.1
  • 11
    • 0031962305 scopus 로고    scopus 로고
    • Statistical comparison of two ROC-curve estimates obtained from partially-paired datasets
    • C. Metz, B. Herman, and C. Roe, "Statistical comparison of two ROC-curve estimates obtained from partially-paired datasets," Med. Decis. Mak. 18(1), p. 110, 1998.
    • (1998) Med. Decis. Mak. , vol.18 , Issue.1 , pp. 110
    • Metz, C.1    Herman, B.2    Roe, C.3
  • 12
    • 0031805838 scopus 로고    scopus 로고
    • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology
    • J. Siewerdsen, L. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, and I. Cunningham, "Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology,"Med. Phys. 25, p. 614, 1998.
    • (1998) Med. Phys. , vol.25 , pp. 614
    • Siewerdsen, J.1    Antonuk, L.2    El-Mohri, Y.3    Yorkston, J.4    Huang, W.5    Cunningham, I.6
  • 13
    • 77955808401 scopus 로고    scopus 로고
    • X-ray phase sensitive imaging methods: Basic physical principles and potential medical applications
    • G.-H. Chen, J. Zambelli, N. Bevins, Z. Qi, and K. Li, "X-ray phase sensitive imaging methods: basic physical principles and potential medical applications," Curr. Med. Imaging Rev. 6(2), pp. 90-99, 2010.
    • (2010) Curr. Med. Imaging Rev. , vol.6 , Issue.2 , pp. 90-99
    • Chen, G.-H.1    Zambelli, J.2    Bevins, N.3    Qi, Z.4    Li, K.5
  • 14
    • 79551654418 scopus 로고    scopus 로고
    • Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography
    • G.-H. Chen, J. Zambelli, K. Li, N. Bevins, and Z. Qi, "Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography," Med. Phys. 38, p. 584, 2011.
    • (2011) Med. Phys. , vol.38 , pp. 584
    • Chen, G.-H.1    Zambelli, J.2    Li, K.3    Bevins, N.4    Qi, Z.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.