메뉴 건너뛰기




Volumn 8313, Issue , 2012, Pages

Image-based synthetic CT: Simulating arbitrary low dose single and dual energy protocols from dual energy images

Author keywords

Dual energy; low dose; protocol optimization; simulated noise; synthetic CT

Indexed keywords

DUAL ENERGY; LOW DOSE; PROTOCOL OPTIMIZATION; SIMULATED NOISE; SYNTHETIC CT;

EID: 84860356694     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.912163     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 4
    • 3242815478 scopus 로고    scopus 로고
    • CT Colonography: Feasibility of Substantial Dose Reduction-Comparison of Medium to Very Low Doses in Identical Patients
    • van Gelder, R., Venema, H., Florie, J., Nio, C., Serlie, I., Schutter, M., van Rijn, J., Vos, F., Glas, A., Bossuyt, P., et al., "CT Colonography: Feasibility of Substantial Dose Reduction-Comparison of Medium to Very Low Doses in Identical Patients," Radiology 232(2), 611-620 (2004).
    • (2004) Radiology , vol.232 , Issue.2 , pp. 611-620
    • Van Gelder, R.1    Venema, H.2    Florie, J.3    Nio, C.4    Serlie, I.5    Schutter, M.6    Van Rijn, J.7    Vos, F.8    Glas, A.9    Bossuyt, P.10
  • 5
    • 4143151587 scopus 로고    scopus 로고
    • Reduced Radiation Dose Helical Chest CT: Effect on Reader Evaluation of Structures and Lung Findings
    • Mayo, J., Kim, K., MacDonald, S., Johkoh, T., Kavanagh, P., Coxson, H., and Vedal, S., "Reduced Radiation Dose Helical Chest CT: Effect on Reader Evaluation of Structures and Lung Findings," Radiology 232(3), 749-756 (2004).
    • (2004) Radiology , vol.232 , Issue.3 , pp. 749-756
    • Mayo, J.1    Kim, K.2    MacDonald, S.3    Johkoh, T.4    Kavanagh, P.5    Coxson, H.6    Vedal, S.7
  • 6
    • 20744455342 scopus 로고    scopus 로고
    • Multi-Detector Row CT Pulmonary Angiography: Comparison of Standard-Dose and Simulated Low-Dose Techniques
    • Tack, D., De Maertelaer, V., Petit, W., Scillia, P., Muller, P., Suess, C., and Gevenois, P., "Multi-Detector Row CT Pulmonary Angiography: Comparison of Standard-Dose and Simulated Low-Dose Techniques,"Radiology 236(1), 318-325 (2005).
    • (2005) Radiology , vol.236 , Issue.1 , pp. 318-325
    • Tack, D.1    De Maertelaer, V.2    Petit, W.3    Scillia, P.4    Muller, P.5    Suess, C.6    Gevenois, P.7
  • 7
    • 42449122744 scopus 로고    scopus 로고
    • Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
    • Bazalova, M., Carrier, J., Beaulieu, L., and Verhaegen, F., "Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations," Physics in Medicine and Biology 53, 2439-2456 (2008).
    • (2008) Physics in Medicine and Biology , vol.53 , pp. 2439-2456
    • Bazalova, M.1    Carrier, J.2    Beaulieu, L.3    Verhaegen, F.4
  • 8
    • 80053616166 scopus 로고    scopus 로고
    • Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan
    • Wang, A. and Pelc, N., "Synthetic CT: Simulating low dose single and dual energy protocols from a dual energy scan," Medical Physics 38, 5551-5562 (2011).
    • (2011) Medical Physics , vol.38 , pp. 5551-5562
    • Wang, A.1    Pelc, N.2
  • 9
    • 79955786680 scopus 로고    scopus 로고
    • Synthetic CT: Simulating arbitrary low dose single and dual energy protocols
    • Wang, A. and Pelc, N., "Synthetic CT: simulating arbitrary low dose single and dual energy protocols," in [Proceedings of SPIE], 7961, 79611R (2011).
    • (2011) Proceedings of SPIE , vol.7961
    • Wang, A.1    Pelc, N.2
  • 10
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x-ray computerised tomography
    • Alvarez, R. and Macovski, A., "Energy-selective reconstructions in x-ray computerised tomography," Physics in Medicine and Biology 21, 733-744 (1976).
    • (1976) Physics in Medicine and Biology , vol.21 , pp. 733-744
    • Alvarez, R.1    Macovski, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.