Volumn 33, Issue 5, 2012, Pages 695-706

A review on electrical impedance tomography for pulmonary perfusion imaging

Author keywords

cardiac changes; electrical impedance tomography (EIT); pulmonary perfusion

Indexed keywords

DIAGNOSIS; ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; FREQUENCY DOMAIN ANALYSIS; PRINCIPAL COMPONENT ANALYSIS;

EID: 84860317930     PISSN: 09673334     EISSN: 13616579     Source Type: Journal    
DOI: 10.1088/0967-3334/33/5/695     Document Type: Review
Times cited : (120)

References (29)
  • 2
    • 62249200419 scopus 로고    scopus 로고
    • Principles of electrical impedance tomography and its clinical application
    • 10.1097/CCM.0b013e3181958d2f 0090-3493
    • Bodenstein M, David M and Markstaller K 2009 Principles of electrical impedance tomography and its clinical application Crit. Care Med. 37 71324
    • (2009) Crit. Care Med. , vol.37 , pp. 713-724
    • Bodenstein, M.1    David, M.2    Markstaller, K.3
  • 3
    • 0036904346 scopus 로고    scopus 로고
    • Electrical impedance tomography
    • 0266-5611 201
    • Borcea L 2002 Electrical impedance tomography Inverse Problems 18 R99136
    • (2002) Inverse Problems , vol.18 , pp. 99-136
    • Borcea, L.1
  • 4
    • 84855409814 scopus 로고    scopus 로고
    • Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse
    • 10.1152/japplphysiol.01090.2010 8750-7587
    • Borges J B et al 2011 Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse J. Appl. Physiol. 112 22536
    • (2011) J. Appl. Physiol. , vol.112 , pp. 225-236
    • Borges, J.B.1
  • 5
    • 0037861995 scopus 로고    scopus 로고
    • Electrical impedance tomography (EIT): A review
    • DOI 10.1080/0309190021000059687
    • Brown B H 2003 Electrical impedance tomography (EIT): a review J. Med. Eng. Technol. 27 97108 (Pubitemid 36745675)
    • (2003) Journal of Medical Engineering and Technology , vol.27 , Issue.3 , pp. 97-108
    • Brown, B.H.1
  • 7
    • 78649332245 scopus 로고    scopus 로고
    • Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation
    • 10.1007/s00134-010-2049-4 0342-4642
    • Carlisle H R, Armstrong R K, Davis P G, Schibler A, Frerichs I and Tingay D G 2010 Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation Intensive Care Med. 36 21018
    • (2010) Intensive Care Med. , vol.36 , pp. 2101-2108
    • Carlisle, H.R.1    Armstrong, R.K.2    Davis, P.G.3    Schibler, A.4    Frerichs, I.5    Tingay, D.G.6
  • 8
    • 45749131440 scopus 로고    scopus 로고
    • Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography
    • 0967-3334 S01
    • Deibele J M, Luepschen H and Leonhardt S 2008 Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography Physiol. Meas. 29 S114
    • (2008) Physiol. Meas. , vol.29 , pp. 1-14
    • Deibele, J.M.1    Luepschen, H.2    Leonhardt, S.3
  • 10
    • 70349747091 scopus 로고    scopus 로고
    • Electrical impedance tomography and heterogeneity of pulmonary perfusion and ventilation in porcine acute lung injury
    • 10.1111/j.1399-6576.2009.02103.x 0001-5172
    • Fagerberg A, Söndergaard S, Karason S and Aneman A 2009a Electrical impedance tomography and heterogeneity of pulmonary perfusion and ventilation in porcine acute lung injury Acta Anaesthesiol. Scand. 53 13009
    • (2009) Acta Anaesthesiol. Scand. , vol.53 , pp. 1300-1309
    • Fagerberg, A.1    Söndergaard, S.2    Karason, S.3    Aneman, A.4
  • 11
    • 58549092626 scopus 로고    scopus 로고
    • Monitoring pulmonary perfusion by electrical impedance tomography: An evaluation in a pig model
    • 10.1111/j.1399-6576.2008.01847.x 0001-5172
    • Fagerberg A, Stenqvist O and Aneman A 2009b Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model Acta Anaesthesiol. Scand. 53 1528
    • (2009) Acta Anaesthesiol. Scand. , vol.53 , pp. 152-158
    • Fagerberg, A.1    Stenqvist, O.2    Aneman, A.3
  • 12
    • 0036591482 scopus 로고    scopus 로고
    • Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging
    • DOI 10.1109/TMI.2002.800585, PII 1011092002800585, Electrical Impedance Tomography
    • Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M and Hellige G 2002 Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging IEEE Trans. Med. Imaging 21 64652 (Pubitemid 34950083)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.6 , pp. 646-652
    • Frerichs, I.1    Hinz, J.2    Herrmann, P.3    Weisser, G.4    Hahn, G.5    Quintel, M.6    Hellige, G.7
  • 13
    • 64449083160 scopus 로고    scopus 로고
    • Assessment of changes in distribution of lung perfusion by electrical impedance tomography
    • 10.1159/000193994 0025-7931
    • Frerichs I, Pulletz S, Elke G, Reifferscheid F, Schadler D, Scholz J and Weiler N 2009 Assessment of changes in distribution of lung perfusion by electrical impedance tomography Respir. 77 28291
    • (2009) Respir. , vol.77 , pp. 282-291
    • Frerichs, I.1    Pulletz, S.2    Elke, G.3    Reifferscheid, F.4    Schadler, D.5    Scholz, J.6    Weiler, N.7
  • 14
    • 78951471583 scopus 로고    scopus 로고
    • Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
    • 10.1186/cc9985 1364-8535
    • Grant C A, Pham T, Hough J, Riedel T, Stocker C and Schibler A 2011 Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography Crit. Care 15 R37
    • (2011) Crit. Care , vol.15 , pp. 37
    • Grant, C.A.1    Pham, T.2    Hough, J.3    Riedel, T.4    Stocker, C.5    Schibler, A.6
  • 16
    • 0031791107 scopus 로고    scopus 로고
    • Ventilation and perfusion imaging by electrical impedance tomography: A comparison with radionuclide scanning
    • DOI 10.1088/0967-3334/19/4/003, PII S0967333498915660
    • Kunst P, Vonk Noordegraaf A, Hoeksta O, Postmus P and Vriest P 1998 Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning Physiol. Meas. 19 48190 (Pubitemid 28546823)
    • (1998) Physiological Measurement , vol.19 , Issue.4 , pp. 481-490
    • Kunst, P.W.A.1    Vonk Noordegraaf, A.2    Hoekstra, O.S.3    Postmus, P.E.4    De Vries, P.M.J.M.5
  • 17
    • 0028276263 scopus 로고
    • A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli
    • 0967-3334 018
    • Leathard A D, Brown B H, Campbell J, Zhang F, Morice a H and Tayler D 1994 A comparison of ventilatory and cardiac related changes in EIT images of normal human lungs and of lungs with pulmonary emboli Physiol. Meas. 15 A13746 (Suppl 2)
    • (1994) Physiol. Meas. , vol.15 , Issue.A2
    • Leathard, A.D.1    Brown, B.H.2    Campbell, J.3    Zhang, F.4    Morice, A.H.5    Tayler, D.6
  • 18
    • 0024240108 scopus 로고
    • An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion
    • DOI 10.1088/0143-0815/9/4A/015
    • McArdle F J, Suggett A J, Brown B H and Barber D C 1988 An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion Clin. Phys. Physiol. Meas. 9 8791 (Suppl. A) (Pubitemid 19020091)
    • (1988) Clinical Physics and Physiological Measurement , vol.9 , Issue.SUPPL. A , pp. 87-91
    • McArdle, F.J.1    Suggett, A.J.2    Brown, B.H.3    Barber, D.C.4
  • 19
    • 34447101159 scopus 로고    scopus 로고
    • A review of errors in multi-frequency EIT instrumentation
    • 0967-3334 S15
    • McEwan A, Cusick G and Holder D S 2007 A review of errors in multi-frequency EIT instrumentation Physiol. Meas. 28 S197215
    • (2007) Physiol. Meas. , vol.28
    • McEwan, A.1    Cusick, G.2    Holder, D.S.3
  • 20
    • 79955640279 scopus 로고    scopus 로고
    • Lung impedance measurements to monitor alveolar ventilation
    • 10.1097/MCC.0b013e3283463c9c 1070-5295
    • Moerer O, Hahn G and Quintel M 2011 Lung impedance measurements to monitor alveolar ventilation Curr. Opin. Crit. Care 17 26067
    • (2011) Curr. Opin. Crit. Care , vol.17 , pp. 260-267
    • Moerer, O.1    Hahn, G.2    Quintel, M.3
  • 21
    • 0029825267 scopus 로고    scopus 로고
    • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images
    • Nopp P, Zhao T X, Brown B H and Wang W 1996 Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images Physiol. Meas. 213 A21325
    • (1996) Physiol. Meas. , vol.213
    • Nopp, P.1    Zhao, T.X.2    Brown, B.H.3    Wang, W.4
  • 22
    • 77954677516 scopus 로고    scopus 로고
    • Separation of ventilation and perfusion related signals within EIT-data streams
    • 1742-6596 012028
    • Pikkemaat R and Leonhardt S 2010 Separation of ventilation and perfusion related signals within EIT-data streams J. Phys.: Conf. Ser. 224 012028
    • (2010) J. Phys.: Conf. Ser. , vol.224
    • Pikkemaat, R.1    Leonhardt, S.2
  • 23
    • 0038777521 scopus 로고    scopus 로고
    • Electrical impedance tomography to measure pulmonary perfusion: Is the reproducibility high enough for clinical practice?
    • DOI 10.1088/0967-3334/24/2/359, PII S0967333403542149
    • Smit H J, Handoko M L, Vonk Noordegraaf A, Faes T J C, Postmus P E, de Vries P M J M and Boonstra A 2003a Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? Physiol. Meas. 24 4919 (Pubitemid 36648413)
    • (2003) Physiological Measurement , vol.24 , Issue.2 , pp. 491-499
    • Smit, H.J.1    Handoko, M.L.2    Vonk Noordegraaf, A.3    Faes, Th.J.C.4    Postmus, P.E.5    De Vries, P.M.J.M.6    Boonstra, A.7
  • 25
    • 33749240345 scopus 로고    scopus 로고
    • Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography
    • DOI 10.1159/000088694
    • Smit H J, Vonk-Noordegraaf A, Boonstra A, de Vries P M and Postmus P E 2006 Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography Respir. 73 597602 (Pubitemid 44481475)
    • (2006) Respiration , vol.73 , Issue.5 , pp. 597-602
    • Smit, H.J.1    Vonk-Noordegraaf, A.2    Boonstra, A.3    De Vries, P.M.4    Postmus, P.E.5
  • 27
    • 0037790938 scopus 로고    scopus 로고
    • Pulmonary vascular responses to hypoxia and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography
    • DOI 10.1378/chest.123.6.1803
    • Smit H J, Vonk Noordegraaf A, Marcus J T, van der Weijden S, Postmus P E, de Vries P M J M and Boonstra A 2003b Pulmonary vascular responses to hypoxia and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography Chest 123 18039 (Pubitemid 36706697)
    • (2003) Chest , vol.123 , Issue.6 , pp. 1803-1809
    • Smit, H.J.1    Vonk-Noordegraaf, A.2    Marcus, J.T.3    Van Der Weijden, S.4    Postmus, P.E.5    De Vries, P.M.J.M.6    Boonstra, A.7
  • 29
    • 0026444174 scopus 로고
    • Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT (electrical impedance tomography) images
    • 10.1088/0143-0815/13/A/037 0143-0815
    • Zadehkoochak M, Blott B H, Hames T K and George R F 1992 Pulmonary perfusion and ventricular ejection imaging by frequency domain filtering of EIT (electrical impedance tomography) images Clin. Phys. Physiol. Meas. 13 1916 (Suppl A)
    • (1992) Clin. Phys. Physiol. Meas. , vol.13 , Issue.A , pp. 191-196
    • Zadehkoochak, M.1    Blott, B.H.2    Hames, T.K.3    George, R.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.