메뉴 건너뛰기




Volumn 69, Issue , 2012, Pages 25-31

Metal argide (MAr +) ions are lost during ion extraction in laser ablation-inductively coupled plasma-mass spectrometry

Author keywords

ICP MS; Laser ablation; MAr + ions; Metal argide ions; Polyatomic ions

Indexed keywords

COLLISION-INDUCED DISSOCIATION; DISSOCIATION ENERGIES; ICP-MS; ION EXTRACTION; KINETIC TEMPERATURES; LA-ICP-MS; LASER-ABLATION INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY; MASS SPECTRA; PLASMA CONDITIONS; POLYATOMIC ION; RELATIVE ABUNDANCE;

EID: 84860268482     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2012.02.008     Document Type: Article
Times cited : (13)

References (51)
  • 1
    • 33847085726 scopus 로고
    • Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements
    • R.S. Houk, V.A. Fassel, G.D. Flesch, H.J. Svec, A.L. Gray, and C.E. Taylor Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements Anal. Chem. 52 1980 2283 2289
    • (1980) Anal. Chem. , vol.52 , pp. 2283-2289
    • Houk, R.S.1    Fassel, V.A.2    Flesch, G.D.3    Svec, H.J.4    Gray, A.L.5    Taylor, C.E.6
  • 3
    • 4244154315 scopus 로고
    • Analytical inductively coupled nitrogen and air plasmas
    • G.A. Meyer, and R.M. Barnes Analytical inductively coupled nitrogen and air plasmas Spectrochim. Acta Part B 40 1985 893 905
    • (1985) Spectrochim. Acta Part B , vol.40 , pp. 893-905
    • Meyer, G.A.1    Barnes, R.M.2
  • 4
    • 0042692779 scopus 로고
    • Inductively coupled nitrogen plasma mass spectrometry assisted by adding argon to the outer gas
    • H. Uchida, and T. Ito Inductively coupled nitrogen plasma mass spectrometry assisted by adding argon to the outer gas J. Anal. At. Spectrom. 10 1995 843 848
    • (1995) J. Anal. At. Spectrom. , vol.10 , pp. 843-848
    • Uchida, H.1    Ito, T.2
  • 5
    • 0025569198 scopus 로고
    • Low-power oxygen inductively coupled plasma for spectrochemical analysis. IV. Analytical features
    • DOI 10.1016/0584-8547(90)80088-Z
    • P. Yang, and R.M. Barnes A low-power oxygen inductively coupled plasma for spectrochemical analysis-IV. Analytical features Spectrochim. Acta Part B 45 1990 167 176 (Pubitemid 21699843)
    • (1990) Spectrochimica acta, Part B: Atomic spectroscopy , vol.45 , Issue.1-2 , pp. 167-176
    • Yang Pengyuan1    Barnes Ramon, M.2
  • 6
    • 5444221156 scopus 로고    scopus 로고
    • Low-pressure helium ICP-MS for trace analysis
    • DOI 10.2116/bunsekikagaku.53.793
    • H. Hayashi, and M. Hiraide Low-pressure helium ICP-MS for trace analysis Bunseki Kagaku 53 2004 793 804 (Pubitemid 39360639)
    • (2004) Bunseki Kagaku , vol.53 , Issue.8 , pp. 793-804
    • Hayashi, H.1    Hiraide, M.2
  • 7
    • 29144480584 scopus 로고    scopus 로고
    • Laser ablation and low-pressure helium-ICP-MS for the analysis of alumina powder dispersed in glycerol
    • DOI 10.2116/analsci.21.1411
    • T. Nagayasu, H. Hayashi, and M. Hiraide Laser ablation and low-pressure helium-ICP-MS for the analysis of alumina powder dispersed in glycerol Anal. Sci. 21 2005 1411 1413 (Pubitemid 41797860)
    • (2005) Analytical Sciences , vol.21 , Issue.12 , pp. 1411-1413
    • Nagayasu, T.1    Hayashi, H.2    Hiraide, M.3
  • 8
    • 0009508250 scopus 로고
    • Generation of a low flow atmospheric pressure neon ICP
    • T. Manning, G. Bentley, B. Palmer, and D. Hof Generation of a low flow atmospheric pressure neon ICP Spectrosc. Lett. 22 1989 341 344
    • (1989) Spectrosc. Lett. , vol.22 , pp. 341-344
    • Manning, T.1    Bentley, G.2    Palmer, B.3    Hof, D.4
  • 9
    • 4244036412 scopus 로고
    • Determination of metals in xylene by inductively coupled air plasma emission spectrometry
    • G.A. Meyer Determination of metals in xylene by inductively coupled air plasma emission spectrometry Spectrochim. Acta Part B 42 1987 201 206
    • (1987) Spectrochim. Acta Part B , vol.42 , pp. 201-206
    • Meyer, G.A.1
  • 10
    • 0030191015 scopus 로고    scopus 로고
    • Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry
    • DOI 10.1016/0584-8547(96)01506-6, PII S0584854796015066
    • H. Niu, and R.S. Houk Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 51 1996 779 815 (Pubitemid 126355385)
    • (1996) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.51 , Issue.8 , pp. 779-815
    • Niu, H.1    Houk, R.S.2
  • 11
    • 0035979152 scopus 로고    scopus 로고
    • Dissociation of polyatomic ions in the inductively coupled plasma
    • DOI 10.1016/S0584-8547(01)00236-1, PII S0584854701002361
    • R.S. Houk, and N. Praphairaksit Dissociation of polyatomic ions in inductively coupled plasma Spectrochim. Acta Part B 56 2001 1069 1096 (Pubitemid 32716108)
    • (2001) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.56 , Issue.7 , pp. 1069-1096
    • Houk, R.S.1    Praphairaksit, N.2
  • 12
    • 33750379519 scopus 로고    scopus 로고
    • High resolution studies of the origins of polyatomic ions in inductively coupled plasma-mass spectrometry, Part I. Identification methods and effects of neutral gas density assumptions, extraction voltage, and cone material
    • DOI 10.1016/j.sab.2006.07.001, PII S0584854706002114
    • J.W. Ferguson, and R.S. Houk High resolution studies of the origins of polyatomic ions in inductively coupled plasma-mass spectrometry, Part I. Identification methods and effects of neutral gas density assumptions, extraction voltage, and cone material Spectrochim. Acta Part B 61 2006 905 915 (Pubitemid 44636079)
    • (2006) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.61 , Issue.8 , pp. 905-915
    • Ferguson, J.W.1    Houk, R.S.2
  • 13
    • 79957798380 scopus 로고    scopus 로고
    • Measurement of gas kinetic temperatures for polyatomic ions in inductively coupled-plasma mass spectrometry: Validation and refinements
    • S.M. McIntyre, J.W. Ferguson, T.M. Witte, and R.S. Houk Measurement of gas kinetic temperatures for polyatomic ions in inductively coupled-plasma mass spectrometry: validation and refinements Spectrochim. Acta Part B 66 2011 248 254
    • (2011) Spectrochim. Acta Part B , vol.66 , pp. 248-254
    • McIntyre, S.M.1    Ferguson, J.W.2    Witte, T.M.3    Houk, R.S.4
  • 14
    • 79959997697 scopus 로고    scopus 로고
    • The effect of quarupole ICPMS interface and ion lens design on argide formation. Implications for LA-ICPMS analysis of PGE's in geological samples
    • M. Guillong, L. Danyushevsky, M. Walle, and M. Raveggi The effect of quarupole ICPMS interface and ion lens design on argide formation. Implications for LA-ICPMS analysis of PGE's in geological samples J. Anal. At. Spectrom. 26 2011 1401 1407
    • (2011) J. Anal. At. Spectrom. , vol.26 , pp. 1401-1407
    • Guillong, M.1    Danyushevsky, L.2    Walle, M.3    Raveggi, M.4
  • 15
    • 0035891206 scopus 로고    scopus 로고
    • Simultaneous ultratrace determination of Zr and Nb in chromium matrixes with ICP-dynamic reaction cell MS
    • DOI 10.1021/ac015549a
    • B. Hattendorf, D. Günther, M. Schönbächler, and A. Halliday Simultaneous ultratrace determination of zr and nb in chromium matrixes with ICP-dynamic reaction cell MS Anal. Chem. 73 2001 5494 5498 (Pubitemid 33108560)
    • (2001) Analytical Chemistry , vol.73 , Issue.22 , pp. 5494-5498
    • Hattendorf, B.1    Gunther, D.2    Schonbachler, M.3    Halliday, A.4
  • 16
    • 0035668452 scopus 로고    scopus 로고
    • A new method to correct Ni- and Cu-argide interference in the determination of the platinum-group elements, Ru, Rh, and Pd, by ICP-MS
    • M.-F. Zhou, J. Malpas, M. Sun, Y. Liu, and X. Fu A new method to correct Ni- and Cu-argide interference in the determination of the platinum-group elements, Ru, Rh, and Pd, by ICP-MS Geochem. J. 35 2001 413 420 (Pubitemid 34025665)
    • (2001) Geochemical Journal , vol.35 , Issue.6 , pp. 413-420
    • Zhou, M.-F.1    Malpas, J.2    Sun, M.3    Liu, Y.4    Fu, X.5
  • 17
    • 0030247880 scopus 로고    scopus 로고
    • Mass spectrometric and theoretical investigations into the formation of argon molecular ions in plasma mass spectrometry
    • J.S. Becker, G. Seifert, A.I. Saprykin, and H.-J. Dietze Mass spectrometric and theoretical investigations into the formation of argon molecular ions in plasma mass spectrometry J. Anal. At. Spectrom. 11 1996 643 648 (Pubitemid 126581178)
    • (1996) Journal of Analytical Atomic Spectrometry , vol.11 , Issue.9 , pp. 643-648
    • Becker, J.S.1    Seifert, G.2    Saprykin, A.I.3    Dietze, H.-J.4
  • 18
    • 0001234823 scopus 로고
    • Mass spectrometric determination of the temperature of an argon inductively coupled plasma from the formation of the singly charged monoxide rare earths and their known dissociation energies
    • H.P. Longerich Mass spectrometric determination of the temperature of an argon inductively coupled plasma from the formation of the singly charged monoxide rare earths and their known dissociation energies J. Anal. Atom. Spectrom. 4 1989 491 497
    • (1989) J. Anal. Atom. Spectrom. , vol.4 , pp. 491-497
    • Longerich, H.P.1
  • 19
    • 0037023111 scopus 로고    scopus 로고
    • Comparative study of the determination of equilibrium dissociation temperature in inductively coupled plasma-mass spectrometry
    • DOI 10.1016/S0584-8547(02)00003-4, PII S0584854702000034
    • E.H. Evans, L. Ebdon, and L. Rowley Comparative study of the determination of equilibrium dissociation temperature in inductively coupled plasma-mass spectrometry Spectrochim. Acta Part B 57 2002 741 754 (Pubitemid 34405325)
    • (2002) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.57 , Issue.4 , pp. 741-754
    • Evans, E.H.1    Ebdon, L.2    Rowley, L.3
  • 24
    • 0001365993 scopus 로고
    • Theoretical study of the interaction of ionized transition metals (Cr, Mn, Fe, Co, Ni, Cu) with argon
    • B.L. Hammond, W.A. Lester Jr., M. Braga, and C.A. Taft Theoretical study of the interaction of ionized transition metals (Cr, Mn, Fe, Co, Ni, Cu) with argon Phys. Rev. A 41 1990 10447 10452
    • (1990) Phys. Rev. A , vol.41 , pp. 10447-10452
    • Hammond, B.L.1    Lester, Jr.W.A.2    Braga, M.3    Taft, C.A.4
  • 26
    • 4244209725 scopus 로고
    • All-electron relativistic Dirac-Fock-Slater self-consistent-field calculations of the singly charged diatomic transition-metal- (Fe, Co, Ni, Cu, Zn) argon molecules
    • T. Bastug, W.-D. Sepp, B. Fricke, E. Johnson, and C.M. Barshick All-electron relativistic Dirac-Fock-Slater self-consistent-field calculations of the singly charged diatomic transition-metal- (Fe, Co, Ni, Cu, Zn) argon molecules Phys. Rev. A 52 1995 2734 2736
    • (1995) Phys. Rev. A , vol.52 , pp. 2734-2736
    • Bastug, T.1    Sepp, W.-D.2    Fricke, B.3    Johnson, E.4    Barshick, C.M.5
  • 28
    • 0000135371 scopus 로고
    • +: Analysis of vibrational structure
    • +: analysis of vibrational structure J. Chem. Phys. 90 1989 6296 6305
    • (1989) J. Chem. Phys. , vol.90 , pp. 6296-6305
    • Lessen, D.1    Brucat, P.J.2
  • 34
    • 0039034012 scopus 로고
    • The electronic partition functions of atoms and ions between 1500 K and 7000 K
    • L. De Galan, R. Smith, and J.D. Winefordner The electronic partition functions of atoms and ions between 1500 K and 7000 K Spectrochim. Acta Part B 23 1968 521 525
    • (1968) Spectrochim. Acta Part B , vol.23 , pp. 521-525
    • De Galan, L.1    Smith, R.2    Winefordner, J.D.3
  • 35
    • 45949128093 scopus 로고
    • The electronic partition functions of atoms and ions between 7000 K and 12 000 K
    • S. Tamaki, and T. Kuroda The electronic partition functions of atoms and ions between 7000 K and 12 000 K Spectrochim. Acta Part B 42 1987 1105 1111
    • (1987) Spectrochim. Acta Part B , vol.42 , pp. 1105-1111
    • Tamaki, S.1    Kuroda, T.2
  • 37
    • 0037349332 scopus 로고    scopus 로고
    • Instrument response functions, mass bias, and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collectore ICP-MS
    • C.P. Ingle, B.L. Sharp, M.S.A. Horstwood, R.R. Parrish, and D.J. Lewis Instrument response functions, mass bias, and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collectore ICP-MS J. Anal. Atom. Spectrom. 18 2003 219 229
    • (2003) J. Anal. Atom. Spectrom. , vol.18 , pp. 219-229
    • Ingle, C.P.1    Sharp, B.L.2    Horstwood, M.S.A.3    Parrish, R.R.4    Lewis, D.J.5
  • 41
    • 0000758476 scopus 로고
    • Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry
    • G.R. Gillson, D.J. Douglas, J.E. Fulford, K.W. Halligan, and S.D. Tanner Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry Anal. Chem. 60 1988 1472 1474
    • (1988) Anal. Chem. , vol.60 , pp. 1472-1474
    • Gillson, G.R.1    Douglas, D.J.2    Fulford, J.E.3    Halligan, K.W.4    Tanner, S.D.5
  • 42
    • 84860298262 scopus 로고    scopus 로고
    • personal, communication
    • D.J. Douglas, personal, communication, (1996, 2011).
    • (1996)
    • Douglas, D.J.1
  • 43
    • 0000960301 scopus 로고
    • Communication. Influence of load coil geometry on oxide and doubly charged ion response in inductively coupled plasma source mass spectrometry
    • A.L. Gray Communication. Influence of load coil geometry on oxide and doubly charged ion response in inductively coupled plasma source mass spectrometry J. Anal. At. Spectrom. 1 1986 247 249
    • (1986) J. Anal. At. Spectrom. , vol.1 , pp. 247-249
    • Gray, A.L.1
  • 44
    • 0028514552 scopus 로고
    • Reduction of fundamental polyatomic ions in inductively coupled plasma mass spectrometry
    • K.I. Sakata, and K. Kawabata Reduction of fundamental polyatomic ions in inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 49 1994 1027 1038
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 1027-1038
    • Sakata, K.I.1    Kawabata, K.2
  • 45
    • 0028513618 scopus 로고
    • Some characteristics of polyatomic ion spectra in inductively coupled plasma mass spectrometry
    • N.S. Nonose, N. Matsuda, N. Fudagawa, and M. Kubota Some characteristics of polyatomic ion spectra in inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 49 1994 955 974
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 955-974
    • Nonose, N.S.1    Matsuda, N.2    Fudagawa, N.3    Kubota, M.4
  • 46
    • 0024774652 scopus 로고
    • Langmuir probe measurements of potential inside a supersonic jet extracted from an inductively coupled plasma
    • DOI 10.1016/0584-8547(89)80099-0
    • H.B. Lim, R.S. Houk, and J.S. Crain Langmuir probe measurements of potential inside a supersonic jet extracted from an inductively coupled plasma Spectrochim. Acta Part B 44 1989 989 998 (Pubitemid 21727464)
    • (1989) Spectrochimica acta, Part B: Atomic spectroscopy , vol.44 , Issue.10 , pp. 989-998
    • Lim, H.B.1    Houk, R.S.2    Crain Jeffrey, S.3
  • 47
    • 0034652371 scopus 로고    scopus 로고
    • Collision-induced dissociation of ions within the orifice-skimmer region of an electrospray mass spectrometer
    • DOI 10.1021/ac990926t
    • B.B. Schneider, and D.D.Y. Chen Collision-induced dissociation of ions with the orifice-skimmer region of an electrospray mass spectrometer Anal. Chem. 72 2000 791 799 (Pubitemid 30111520)
    • (2000) Analytical Chemistry , vol.72 , Issue.4 , pp. 791-799
    • Schneider, B.B.1    Chen, D.D.Y.2
  • 48
    • 80052909442 scopus 로고    scopus 로고
    • + in inductively coupled plasma-mass spectrometry: Effects of excited electronic states and dissociation pathways
    • + in inductively coupled plasma-mass spectrometry: effects of excited electronic states and dissociation pathways Spectrochim. Acta Part B 66 2011 581 587
    • (2011) Spectrochim. Acta Part B , vol.66 , pp. 581-587
    • McIntyre, S.M.1    Ferguson, J.W.2    Houk, R.S.3
  • 49
    • 0032665589 scopus 로고    scopus 로고
    • Optically determined velocity distributions of metastable argon in the second stage of an inductively coupled plasma mass spectrometer
    • J.E. Patterson, B.S. Duersch, and P.B. Farnsworth Optically determined velocity distributions of metastable argon in the second stage of an inductively coupled plasma mass spectrometer Spectrochim. Acta Part B 54 1999 537 544
    • (1999) Spectrochim. Acta Part B , vol.54 , pp. 537-544
    • Patterson, J.E.1    Duersch, B.S.2    Farnsworth, P.B.3
  • 50
    • 33745845501 scopus 로고    scopus 로고
    • Characterization of the supersonic expansion in the vacuum interface of an inductively coupled plasma mass spectrometer by high-resolution diode laser spectroscopy
    • DOI 10.1016/j.sab.2005.09.004, PII S0584854705002788
    • W.N. Radicic, J.B. Olsen, R.V. Nielson, J.H. Macedone, and P.B. Farnsworth Characterization of the supersonic expansion in the vacuum interface of an inductively coupled plasma mass spectrometer by high-resolution diode laser spectroscopy Spectrochim. Acta Part B 61 2006 686 695 (Pubitemid 44038141)
    • (2006) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.61 , Issue.6 , pp. 686-695
    • Radicic, W.N.1    Olsen, J.B.2    Nielson, R.V.3    Macedone, J.H.4    Farnsworth, P.B.5
  • 51
    • 84860275885 scopus 로고    scopus 로고
    • Experimental characterization of the effect of skimmer cone design on shock formation and ion transmission efficiency in the vacuum interface of an inductively coupled plasma mass spectrometer
    • submitted for publication
    • N. Taylor, P.B. Farnsworth, Experimental characterization of the effect of skimmer cone design on shock formation and ion transmission efficiency in the vacuum interface of an inductively coupled plasma mass spectrometer, Spectrochim. Acta Part B (2012) submitted for publication.
    • (2012) Spectrochim. Acta Part B
    • Taylor, N.1    Farnsworth, P.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.