Calibration and evaluation of a magnetically tracked ICE probe for guidance of left atrial ablation therapy

Author keywords

Calibration; Image Guided Cardiac Procedures; Intra operative Imaging; Localization and Tracking Technologies; Ultrasound Guidance

Indexed keywords

ABLATION THERAPY; CLINICAL APPLICATION; EVALUATION METHOD; FIDUCIALS; IMAGE-GUIDED; INTERVENTIONAL; INTRA-OPERATIVE; INTRACARDIAC ECHOCARDIOGRAPHIES; LOCALIZATION AND TRACKING; MULTIPLE IMAGING MODALITY; PATIENT'S HEART; PROTOTYPE SYSTEM; SUBJECT-SPECIFIC; SURGICAL INSTRUMENT; TARGET LOCALIZATION; TARGET LOCATION; ULTRASOUND CALIBRATION; ULTRASOUND GUIDANCE; VALIDATION STUDY; VOLUME RECONSTRUCTION;

EID: 84860253220     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.912869     Document Type: Conference Paper
Times cited : (3)

References (14)
  • 2
    • 25444454665 scopus 로고    scopus 로고
    • Catheter ablation of atrial fibrillation guided by registered computed tomographic image of the atrium
    • J. Dong, T. Dickfeld, S. Z. Lamiy, and H. Calkins, "Catheter ablation of atrial fibrillation guided by registered computed tomographic image of the atrium," Heart Rhythm 2, pp. 1021-2., 2005.
    • (2005) Heart Rhythm , vol.2 , pp. 1021-1022
    • Dong, J.1    Dickfeld, T.2    Lamiy, S.Z.3    Calkins, H.4
  • 3
    • 15944409546 scopus 로고    scopus 로고
    • Stereotactic catheter navigation using magnetic resonance image integration in the human heart
    • T. Dickfeld, H. Calkins, D. Bradley, and S. Solomon, "Stereotactic catheter navigation using magnetic resonance image integration in the human heart," Heart Rhythm 2, pp. 413-5., 2005.
    • (2005) Heart Rhythm , vol.2 , pp. 413-415
    • Dickfeld, T.1    Calkins, H.2    Bradley, D.3    Solomon, S.4
  • 4
    • 25444458106 scopus 로고    scopus 로고
    • Registration of 3D left atrial computed tomographic images with fluoroscopy
    • J. Sra, D. Krum, B. Belanger, and R. Vaillant, "Registration of 3D left atrial computed tomographic images with fluoroscopy," Heart Rhythm 2, pp. 1020-2, 2005.
    • (2005) Heart Rhythm , vol.2 , pp. 1020-1022
    • Sra, J.1    Krum, D.2    Belanger, B.3    Vaillant, R.4
  • 5
    • 67349086267 scopus 로고    scopus 로고
    • An event-driven distributed processing architecture for image-guided cardiac ablation therapy
    • M. Rettmann, D. R. Holmes III, B. Cameron, and R. A. Robb, "An event-driven distributed processing architecture for image-guided cardiac ablation therapy," ComputMethods Programs Biomed. 95, pp. 95-104, 2009.
    • (2009) ComputMethods Programs Biomed. , vol.95 , pp. 95-104
    • Rettmann, M.1    Holmes III, D.R.2    Cameron, B.3    Robb, R.A.4
  • 6
    • 0013566626 scopus 로고    scopus 로고
    • Intracardiac ultrasound guidance of multipolar atrial and ventricular mapping basket applications
    • S. Johnson and D. L. Packer, "Intracardiac ultrasound guidance of multipolar atrial and ventricular mapping basket applications," J Am Coll Cardiol. 29, p. 202A, 1997.
    • (1997) J Am Coll Cardiol. , vol.29
    • Johnson, S.1    Packer, D.L.2
  • 7
    • 0029422063 scopus 로고
    • Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery
    • R. Rohling, P. Munger, J. M. Hollerbach, and T. Peter, "Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery," J Image Guid Surg. 1, pp. 30-4, 1995.
    • (1995) J Image Guid Surg. , vol.1 , pp. 30-34
    • Rohling, R.1    Munger, P.2    Hollerbach, J.M.3    Peter, T.4
  • 10
    • 84957066839 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • Proc. Med Image Comput Comput Assist Interv.
    • D. G. Gobbi, R. M. Comeau, and T. M. Peters, "Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift," in Proc. Med Image Comput Comput Assist Interv., Lect Notes Comput Sci 1679, pp. 920-927, 1999.
    • (1999) Lect Notes Comput Sci , vol.1679 , pp. 920-927
    • Gobbi, D.G.1    Comeau, R.M.2    Peters, T.M.3
  • 11
    • 0033995330 scopus 로고    scopus 로고
    • Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery
    • R. Comeau, A. F. Sadikot, A. Fenster, and T. M. Peters, "Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery," Med Phys. 27, pp. 787-800, 2000.
    • (2000) Med Phys. , vol.27 , pp. 787-800
    • Comeau, R.1    Sadikot, A.F.2    Fenster, A.3    Peters, T.M.4
  • 12
    • 33744829272 scopus 로고    scopus 로고
    • A novel phantom-less spatial and temporal ultrasound calibration method
    • Proc. Med Image Comput Comput Assist Interv.
    • A. Khamene and F. Sauer, "A novel phantom-less spatial and temporal ultrasound calibration method," in Proc. Med Image Comput Comput Assist Interv., Lect Notes Comput Sci. 3750, pp. 671-78, 2004.
    • (2004) Lect Notes Comput Sci. , vol.3750 , pp. 671-678
    • Khamene, A.1    Sauer, F.2
  • 13
    • 44949180930 scopus 로고    scopus 로고
    • Developing patient-specific anatomic models for validation of cardiac ablation guidance procedures
    • D. R. Holmes III, M. Rettmann, B. Cameron, J. Camp, and R. Robb, "Developing patient-specific anatomic models for validation of cardiac ablation guidance procedures," Proc. SPIE Medical Imaging 6918, pp. 69181W-8, 2008.
    • (2008) Proc. SPIE Medical Imaging , vol.6918
    • Holmes III, D.R.1    Rettmann, M.2    Cameron, B.3    Camp, J.4    Robb, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.