메뉴 건너뛰기




Volumn 53, Issue 2, 2012, Pages 873-880

Depth-dependent transverse shear properties of the human corneal stroma

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; CADAVER; COMPRESSION; CORNEA STROMA; CORNEA THICKNESS; FEMTOSECOND LASER; HUMAN; HUMAN TISSUE; MECHANICAL TORSION; PRIORITY JOURNAL; SHEAR STRENGTH; VALIDITY; COMPARATIVE STUDY; DONOR; MATERIALS TESTING; METHODOLOGY; PHYSIOLOGY;

EID: 84859979202     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.11-8611     Document Type: Article
Times cited : (129)

References (28)
  • 1
    • 33847014493 scopus 로고    scopus 로고
    • Assessment of corneal biomechanical properties and their variation with age
    • Elsheikh A, Wang D, Brown M, Rama P, Campanelli M, Pye D. Assessment of corneal biomechanical properties and their variation with age. Curr Eye Res. 2007;32:11-19.
    • (2007) Curr Eye Res , vol.32 , pp. 11-19
    • Elsheikh, A.1    Wang, D.2    Brown, M.3    Rama, P.4    Campanelli, M.5    Pye, D.6
  • 3
    • 0030199985 scopus 로고    scopus 로고
    • Regional elastic performance of the human cornea
    • Hjortdal J.O. Regional elastic performance of the human cornea. J Biomech. 1996;29:931-942.
    • (1996) J Biomech , vol.29 , pp. 931-942
    • Hjortdal, J.O.1
  • 4
    • 47849123765 scopus 로고    scopus 로고
    • Full-field deformation of bovine cornea under constrained inflation conditions
    • Boyce BL, Grazier JM, Jones RE, Nguyen TD. Full-field deformation of bovine cornea under constrained inflation conditions. Biomaterials. 2008;29:3896-3904.
    • (2008) Biomaterials , vol.29 , pp. 3896-3904
    • Boyce, B.L.1    Grazier, J.M.2    Jones, R.E.3    Nguyen, T.D.4
  • 5
    • 84861132734 scopus 로고
    • Chapter 3.1: Transversely isotropic media
    • 1st ed. New York, NY: John Wiley & Sons
    • Christensen RM. Chapter 3.1: Transversely isotropic media. In: Mechanics of Composite Materials. 1st ed. New York, NY: John Wiley & Sons; 1979:74-80.
    • (1979) Mechanics of Composite Materials , pp. 74-80
    • Christensen, R.M.1
  • 7
    • 77953542585 scopus 로고    scopus 로고
    • A computational remodeling approach to predict the physiological architecture of the collagen fibril network in corneo-scleral shells
    • Grytz R, Meschke G. A computational remodeling approach to predict the physiological architecture of the collagen fibril network in corneo-scleral shells. Biomech Model Mechanobiol. 2010; 9:225-235.
    • (2010) Biomech Model Mechanobiol , vol.9 , pp. 225-235
    • Grytz, R.1    Meschke, G.2
  • 8
    • 13844317409 scopus 로고    scopus 로고
    • Computational modeling of mechanical anisotropy in the cornea and sclera
    • Pinsky PM, van der Heide D, Chernyak D. Computational modeling of mechanical anisotropy in the cornea and sclera. J Cataract Refract Surg. 2005;31:136-145.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 136-145
    • Pinsky, P.M.1    van der Heide, D.2    Chernyak, D.3
  • 11
    • 77957593176 scopus 로고    scopus 로고
    • Evaluating corneal collagen organization using high-resolution nonlinear optical macroscopy
    • Jester JV, Winkler M, Jester BE, Nien C, Chai D, Brown DJ. Evaluating corneal collagen organization using high-resolution nonlinear optical macroscopy. Eye Contact Lens. 2010;36:260-264.
    • (2010) Eye Contact Lens , vol.36 , pp. 260-264
    • Jester, J.V.1    Winkler, M.2    Jester, B.E.3    Nien, C.4    Chai, D.5    Brown, D.J.6
  • 12
    • 84855407646 scopus 로고    scopus 로고
    • Nonlinear optical macroscopic assessment of 3-D corneal collagen organization and axial biomechanics
    • Winkler M, Chai D, Kriling S, et al. Nonlinear optical macroscopic assessment of 3-D corneal collagen organization and axial biomechanics. Invest Ophthalmol Vis Sci. 2011;52:8818-8827.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8818-8827
    • Winkler, M.1    Chai, D.2    Kriling, S.3
  • 13
    • 0026002067 scopus 로고
    • The three-dimensional organization of collagen fibrils in the human cornea and sclera
    • Komai Y, Ushiki T. The three-dimensional organization of collagen fibrils in the human cornea and sclera. Invest Ophthalmol Vis Sci. 1991;32:2244-2258.
    • (1991) Invest Ophthalmol Vis Sci , vol.32 , pp. 2244-2258
    • Komai, Y.1    Ushiki, T.2
  • 14
    • 76749112649 scopus 로고    scopus 로고
    • 3D collagen orientation study of the human cornea using X-ray diffraction and femtosecond laser technology
    • Abahussin M, Hayes S, Knox Cartwright NE, et al. 3D collagen orientation study of the human cornea using X-ray diffraction and femtosecond laser technology. Invest Ophthalmol Vis Sci. 2009; 50:5159-5164.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 5159-5164
    • Abahussin, M.1    Hayes, S.2    Knox, C.N.E.3
  • 15
    • 0036822477 scopus 로고    scopus 로고
    • A randomized, double-masked clinical trial of Optisol-GS vs Chen Medium for human corneal storage
    • Naor J, Slomovic AR, Chipman M, Rootman DS. A randomized, double-masked clinical trial of Optisol-GS vs Chen Medium for human corneal storage. Arch Ophthalmol. 2002;120:1280-1285.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1280-1285
    • Naor, J.1    Slomovic, A.R.2    Chipman, M.3    Rootman, D.S.4
  • 16
    • 0000376091 scopus 로고
    • Swelling of the cornea in vivo after the destruction of its limiting layers
    • Maurice DM, Giardini AA. Swelling of the cornea in vivo after the destruction of its limiting layers. Br J Ophthalmol. 1951;35:791-797.
    • (1951) Br J Ophthalmol , vol.35 , pp. 791-797
    • Maurice, D.M.1    Giardini, A.A.2
  • 17
    • 45249084956 scopus 로고    scopus 로고
    • Epithelial thickness in the normal cornea: Three-dimensional display with very high frequency ultrasound
    • Reinstein DZ, Archer TJ, Gobbe M, Silverman RH, Coleman DJ. Epithelial thickness in the normal cornea: three-dimensional display with very high frequency ultrasound. J Refract Surg. 2008; 24:571-581.
    • (2008) J Refract Surg , vol.24 , pp. 571-581
    • Reinstein, D.Z.1    Archer, T.J.2    Gobbe, M.3    Silverman, R.H.4    Coleman, D.J.5
  • 18
    • 84861108415 scopus 로고
    • Scanning electron microscopic studies of the corneal endothelium in man and monkeys
    • Svenbergh B, Bill A. Scanning electron microscopic studies of the corneal endothelium in man and monkeys. Acta Ophthalmologica. 1972;26:136-143.
    • (1972) Acta Ophthalmologica , vol.26 , pp. 136-143
    • Svenbergh, B.1    Bill, A.2
  • 19
    • 0023268038 scopus 로고
    • The swelling pressure of the human corneal stroma as determined by a new method
    • Olsen T, Sperling S. The swelling pressure of the human corneal stroma as determined by a new method. Exp Eye Res. 1987;44: 481-490.
    • (1987) Exp Eye Res , vol.44 , pp. 481-490
    • Olsen, T.1    Sperling, S.2
  • 21
    • 0034603359 scopus 로고    scopus 로고
    • Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    • Doughty MJ, Zaman ML. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol. 2000;44:367-408.
    • (2000) Surv Ophthalmol , vol.44 , pp. 367-408
    • Doughty, M.J.1    Zaman, M.L.2
  • 23
    • 79955039196 scopus 로고    scopus 로고
    • Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer
    • Kopito R, Gaujoux T, Montard R, et al. Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer. Acta Ophthalmologica. 2011;89: 225-230.
    • (2011) Acta Ophthalmologica , vol.89 , pp. 225-230
    • Kopito, R.1    Gaujoux, T.2    Montard, R.3
  • 24
    • 39149134885 scopus 로고    scopus 로고
    • Assessment of the epithelium's contribution to corneal biomechanics
    • Elsheikh A, Alhasso D, Rama P. Assessment of the epithelium's contribution to corneal biomechanics. Exp Eye Res. 2008;86:445-451.
    • (2008) Exp Eye Res , vol.86 , pp. 445-451
    • Elsheikh, A.1    Alhasso, D.2    Rama, P.3
  • 25
    • 0026762792 scopus 로고
    • Does Bowman's layer determine the biomechanical properties of the cornea?
    • Seiler T, Matallana M, Sendler S, Bende T. Does Bowman's layer determine the biomechanical properties of the cornea? Refract Corneal Surg. 1992;8:139-142.
    • (1992) Refract Corneal Surg , vol.8 , pp. 139-142
    • Seiler, T.1    Matallana, M.2    Sendler, S.3    Bende, T.4
  • 26
    • 0022929770 scopus 로고
    • The mechanical properties of the rabbit and human cornea
    • Jue B, Maurice DM. The mechanical properties of the rabbit and human cornea. J Biomech. 1986;19:847-853.
    • (1986) J Biomech , vol.19 , pp. 847-853
    • Jue, B.1    Maurice, D.M.2
  • 27
    • 4444294390 scopus 로고    scopus 로고
    • Tensile mechanical and creep properties of Descemet's membrane and lens capsule
    • Danielsen CC. Tensile mechanical and creep properties of Descemet's membrane and lens capsule. Exp Eye Res. 2004;79:343-350.
    • (2004) Exp Eye Res , vol.79 , pp. 343-350
    • Danielsen, C.C.1
  • 28
    • 0035818682 scopus 로고    scopus 로고
    • Effect of electrostatic interactions between glycosaminoglycans on the shear stiffness of cartilage: A molecular model and experiments
    • Jin M, Grodzinsky AJ. Effect of electrostatic interactions between glycosaminoglycans on the shear stiffness of cartilage: a molecular model and experiments. Macromolecules. 2001;34:8330-8339.
    • (2001) Macromolecules , vol.34 , pp. 8330-8339
    • Jin, M.1    Grodzinsky, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.