메뉴 건너뛰기




Volumn 9, Issue 5, 2012, Pages 750-751

The Riata story - Where are we now?

Author keywords

[No Author keywords available]

Indexed keywords

LEAD; POLYURETHAN; SILICONE;

EID: 84859972412     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2012.01.013     Document Type: Editorial
Times cited : (6)

References (8)
  • 1
    • 84860006215 scopus 로고    scopus 로고
    • St Jude Medical Available at: riatacommunication.com. Accessed January 10, 2012
    • St Jude Medical. Medical device advisory (Riata ICD leads). 2010. Available at: riatacommunication.com. Accessed January 10, 2012.
    • (2010) Medical Device Advisory (Riata ICD Leads)
  • 2
    • 50949122705 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillator lead disintegration at the level of the tricuspid valve
    • Duray GZ, Israel CW, Schmitt J, Hohnloser SH. Implantable cardioverter-defibrillator lead disintegration at the level of the tricuspid valve. Heart Rhythm 2008;5:1224-1225.
    • (2008) Heart Rhythm , vol.5 , pp. 1224-1225
    • Duray, G.Z.1    Israel, C.W.2    Schmitt, J.3    Hohnloser, S.H.4
  • 3
    • 77956877526 scopus 로고    scopus 로고
    • Unusual failure of a multilumen, small-diameter implantable cardioverter-defibrillator lead
    • Jalal Z, Derval N, Ploux S, Bordachar P. Unusual failure of a multilumen, small-diameter implantable cardioverter-defibrillator lead. Heart Rhythm 2010;7:1166-1167.
    • (2010) Heart Rhythm , vol.7 , pp. 1166-1167
    • Jalal, Z.1    Derval, N.2    Ploux, S.3    Bordachar, P.4
  • 4
    • 84859939804 scopus 로고    scopus 로고
    • Riata implantable cardioverter-defibrillator lead failure: Analysis of explanted leads with a unique insulation defect
    • Hauser RG, McGriff D, Retel LK. Riata implantable cardioverter- defibrillator lead failure: analysis of explanted leads with a unique insulation defect. Heart Rhythm 2012;9:742-749.
    • (2012) Heart Rhythm , vol.9 , pp. 742-749
    • Hauser, R.G.1    McGriff, D.2    Retel, L.K.3
  • 5
    • 50549103961 scopus 로고    scopus 로고
    • How to prevent, recognize, and manage complications of lead extraction, Part III: Procedural factors
    • Henrikson CA, Brinker JA. How to prevent, recognize, and manage complications of lead extraction, Part III: procedural factors. Heart Rhythm 2008;5:1352-1354.
    • (2008) Heart Rhythm , vol.5 , pp. 1352-1354
    • Henrikson, C.A.1    Brinker, J.A.2
  • 6
    • 80052834751 scopus 로고    scopus 로고
    • Premature failure of a Riata defibrillator lead without impedance change or inappropriate sensing: A case report and review of the literature
    • Krebsbach A, Alhumaid F, Henrikson CA, Calkins H, Berger RD, Cheng A. Premature failure of a Riata defibrillator lead without impedance change or inappropriate sensing: a case report and review of the literature. J Cardiovasc Electrophysiol 2011;22:1070-1072.
    • (2011) J Cardiovasc Electrophysiol , vol.22 , pp. 1070-1072
    • Krebsbach, A.1    Alhumaid, F.2    Henrikson, C.A.3    Calkins, H.4    Berger, R.D.5    Cheng, A.6
  • 7
    • 84859958736 scopus 로고    scopus 로고
    • Riata lead failure: A report from the Northern Ireland Riata Lead Screening Programme
    • abstract
    • Kodoth V, Cromie N, Lau E, McEneaney D, Wilson C, Roberts MJ. Riata lead failure: a report from the Northern Ireland Riata Lead Screening Programme [abstract]. Eur Heart J 2011;32:P1838.
    • (2011) Eur Heart J , vol.32 , pp. 1838
    • Kodoth, V.1    Cromie, N.2    Lau, E.3    McEneaney, D.4    Wilson, C.5    Roberts, M.J.6
  • 8
    • 84859947979 scopus 로고    scopus 로고
    • St Jude Medical. Available at: riatacommunication.com. Accessed January 10, 2012
    • St Jude Medical. Important product information (Riata ICD leads). 2011. Available at: riatacommunication.com. Accessed January 10, 2012.
    • (2011) Important Product Information (Riata ICD Leads)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.