메뉴 건너뛰기




Volumn 18, Issue 1, 2002, Pages 13-25

Amperometric biosensors. Key work principles and features of transducers of different generations

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84859941215     PISSN: 02337657     EISSN: 19936842     Source Type: Journal    
DOI: 10.7124/bc.0005E4     Document Type: Review
Times cited : (3)

References (95)
  • 1
    • 84942558425 scopus 로고
    • Monitor and control of blood and tissue oxygen tensions
    • Clark JL C, Jr. Monitor and control of blood and tissue oxygen tensions // Trans. Amer. Soc. Artif. Int. Organs.-1956.-2.-P. 41-48.
    • (1956) Trans. Amer. Soc. Artif. Int. Organs. , vol.2 , pp. 41-48
    • Clark Jr., J.L.C.1
  • 2
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • Clark L. C, Lyons C. Electrode systems for continuous monitoring in cardiovascular surgery // Ann. New York Acad. Sci.-1962.-102.-P. 29-45.
    • (1962) Ann. New York Acad. Sci. , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 3
    • 0014191637 scopus 로고
    • The enzyme electrode
    • Updike S. J., Hicks G. P. The enzyme electrode // Nature.-1967.-214.-P. 986-988.
    • (1967) Nature. , vol.214 , pp. 986-988
    • Updike, S.J.1    Hicks, G.P.2
  • 4
    • 0003822415 scopus 로고
    • Cambridge: Open Univ. press
    • Hall E. Biosensors.-Cambridge: Open Univ. press, 1991.
    • (1991) Biosensors.
    • Hall, E.1
  • 6
    • 0022187178 scopus 로고
    • Electrochemical techniques for the development of amperometric biosensors
    • Davis G. Electrochemical techniques for the development of amperometric biosensors // Biosensors.-1985-1.-P. 161-168.
    • (1985) Biosensors. , vol.1 , pp. 161-168
    • Davis, G.1
  • 7
    • 1342339054 scopus 로고    scopus 로고
    • Biosensors for food analysis
    • Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser
    • Warsinke A. Biosensors for food analysis // Frontiers in Biosensorics II. Practical Applications / Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser, 1997.-P. 121.
    • (1997) Frontiers in Biosensorics II. Practical Applications , pp. 121
    • Warsinke, A.1
  • 9
    • 0030638588 scopus 로고    scopus 로고
    • Commercial biosensors for medical application
    • Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser
    • Pfeiffer D. Commercial biosensors for medical application // Frontiers in Biosensorics II. Practical Applications / Eds F. W. Scheller, F. Schubert, J. Fedrowitz.-Basel: Birkhauser, 1997.-P. 149-160.
    • (1997) Frontiers in Biosensorics II. Practical Applications , pp. 149-160
    • Pfeiffer, D.1
  • 10
    • 0001441464 scopus 로고
    • A reliable L-lactate electrode with a new membrane for enzyme immobilization for amperometric assay of lactate
    • Bardeletti G, Sechaud F, Coilet P. R. A reliable L-lactate electrode with a new membrane for enzyme immobilization for amperometric assay of lactate // Anal. Chim. Acta.-1986.-187.-P. 47-54.
    • (1986) Anal. Chim. Acta. , vol.187 , pp. 47-54
    • Bardeletti, G.1    Sechaud, F.2    Coilet, P.R.3
  • 11
    • 4244186437 scopus 로고
    • An enzyme electrode for L-lactate with chemically amplified electrode
    • Mizutani F., Yamanaka T., Tanabe Y., Tsuda K An enzyme electrode for L-lactate with chemically amplified electrode // Anal. Chim. Acta.-1985.-177.-P. 153-166.
    • (1985) Anal. Chim. Acta. , vol.177 , pp. 153-166
    • Mizutani, F.1    Yamanaka, T.2    Tanabe, Y.3    Tsuda, K.4
  • 12
    • 84985653970 scopus 로고
    • Amperometric determination of choline with use of immobilized choline oxidase
    • Matsumoto K., Seijo H., Karube I., Suzuki S. Amperometric determination of choline with use of immobilized choline oxidase // Biotech, and Bioeng.-1980.-22.-P. 1071-1086.
    • (1980) Biotech, and Bioeng. , vol.22 , pp. 1071-1086
    • Matsumoto, K.1    Seijo, H.2    Karube, I.3    Suzuki, S.4
  • 13
    • 0030933561 scopus 로고    scopus 로고
    • Enzyme modified amperometric sensors for choline and acetylcholine with tetrathiafulvalene tetracyanoquinodimethane as the electron-transfer mediator
    • Xin Q., Wightman R. M. Enzyme modified amperometric sensors for choline and acetylcholine with tetrathiafulvalene tetracyanoquinodimethane as the electron-transfer mediator // Anal. Chim. Acta.-1997,-341.-P. 43-51.
    • (1997) Anal. Chim. Acta. , vol.341 , pp. 43-51
    • Xin, Q.1    Wightman, R.M.2
  • 15
    • 0034253374 scopus 로고    scopus 로고
    • Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer
    • Boujtita M., Hart J. P., Pittson R. Development of a disposable ethanol biosensor based on a chemically modified screen-printed electrode coated with alcohol oxidase for the analysis of beer // Biosensors and Bioelectronics.-2000.-15.-P. 257-263.
    • (2000) Biosensors and Bioelectronics. , vol.15 , pp. 257-263
    • Boujtita, M.1    Hart, J.P.2    Pittson, R.3
  • 16
    • 0343582417 scopus 로고
    • A family of polarographic enzyme electrodes and the measurement of alcohol
    • Clark L. C, Jr. A family of polarographic enzyme electrodes and the measurement of alcohol // Biotech, and Bioeng.-1972.-3.-P. 377-394.
    • (1972) Biotech, and Bioeng. , vol.3 , pp. 377-394
    • Clark Jr., L.C.1
  • 17
    • 0023595747 scopus 로고
    • An enzyme electrode for on-line determination of ethanol and methanol
    • Belghitin H., Romette J. L., Thomas D. An enzyme electrode for on-line determination of ethanol and methanol // Biotech, and Bioeng.-1987.-30.-P. 1001-1005.
    • (1987) Biotech, and Bioeng. , vol.30 , pp. 1001-1005
    • Belghitin, H.1    Romette, J.L.2    Thomas, D.3
  • 19
  • 20
    • 0028859996 scopus 로고
    • A biosensor for L-tryptophan determination based on recombinant Pseudomonas savastanoi tryptophan-2-monooxygenase
    • Simonian A. L., Rainina E. I., Wild J., Fitzpatrick P. F. A biosensor for L-tryptophan determination based on recombinant Pseudomonas savastanoi tryptophan-2-monooxygenase // Anal. Lett-1995.-28.-P. 1751-1761.
    • (1995) Anal. Lett , vol.28 , pp. 1751-1761
    • Simonian, A.L.1    Rainina, E.I.2    Wild, J.3    Fitzpatrick, P.F.4
  • 21
    • 0344609654 scopus 로고    scopus 로고
    • Amperometric determination of lysine oxidase biosensor based on rigid-conducting composites
    • Saurina J., Hernandez-Cassou S., Alegret S., Fabregas E. Amperometric determination of lysine oxidase biosensor based on rigid-conducting composites // Biosensors and Bioelectronics.-1999.-14.-P. 211-220.
    • (1999) Biosensors and Bioelectronics. , vol.14 , pp. 211-220
    • Saurina, J.1    Hernandez-Cassou, S.2    Alegret, S.3    Fabregas, E.4
  • 22
    • 0027076580 scopus 로고
    • Biosensor for determination of L-lysin
    • Vrbova E., Marek M., Ralys E. Biosensor for determination of L-lysin // Anal. Chim. Acta.-1992.-279.-P. 131-136.
    • (1992) Anal. Chim. Acta. , vol.279 , pp. 131-136
    • Vrbova, E.1    Marek, M.2    Ralys, E.3
  • 23
    • 0002202341 scopus 로고    scopus 로고
    • Renewable-surface graphite-ceramic enzyme sensors for the determination of hypoxantine in fish meat
    • Niu J., Yang JL J. Renewable-surface graphite-ceramic enzyme sensors for the determination of hypoxantine in fish meat // Anal. Commun.-1999.-36.-P. 81-83.
    • (1999) Anal. Commun. , vol.36 , pp. 81-83
    • Niu, J.1    Yang, J.L.J.2
  • 24
    • 0004189734 scopus 로고    scopus 로고
    • Chichester-Stuttgart: John Wiley and Sons and Teubner
    • Eggins B. R. Biosensors: an introduction.-Chichester-Stuttgart: John Wiley and Sons and Teubner, 1996.-P. 31-51.
    • (1996) Biosensors: An introduction. , pp. 31-51
    • Eggins, B.R.1
  • 26
    • 0006873386 scopus 로고
    • Amperometric enzyme electrodes. Part IV. An enzyme electrode for ethanol
    • Albery W. I., Bartlett P. N., Cass A. E. G, Sim K. W. Amperometric enzyme electrodes. Part IV. An enzyme electrode for ethanol // J. Electroanal. Chem.-1987.-218.-P. 127-134.
    • (1987) J. Electroanal. Chem. , vol.218 , pp. 127-134
    • Albery, W.I.1    Bartlett, P.N.2    Cass, A.E.G.3    Sim, K.W.4
  • 27
    • 0025778865 scopus 로고
    • Development of an amperometric alcohol sensor based on immobilized alcohol-dehydrogenase and entrapped NAD+
    • Miyamoto S., Murakami T., Saiti A., Kimura J. Development of an amperometric alcohol sensor based on immobilized alcohol-dehydrogenase and entrapped NAD+ // Biosensors and Bioelectronics.-1991.-6.-P. 563-567.
    • (1991) Biosensors and Bioelectronics. , vol.6 , pp. 563-567
    • Miyamoto, S.1    Murakami, T.2    Saiti, A.3    Kimura, J.4
  • 28
    • 0011903437 scopus 로고
    • Reagentless enzyme electrode for ethanol, lactate, and malate
    • Blaedel W. J., Engstrom R. C. Reagentless enzyme electrode for ethanol, lactate, and malate // Anal. Chem.-1980.-52.-P. 1691-1697.
    • (1980) Anal. Chem. , vol.52 , pp. 1691-1697
    • Blaedel, W.J.1    Engstrom, R.C.2
  • 29
    • 0032310226 scopus 로고    scopus 로고
    • NADH amperometric sensor based on poly (3-methylthiophene)-coated cylindrical carbon fiber microelectrodes: Application to the enzymatic determination of L-lactate
    • Jaraba P., Agui L., Yanez-Sedeno P., Pingarron J. M. NADH amperometric sensor based on poly (3-methylthiophene)-coated cylindrical carbon fiber microelectrodes: application to the enzymatic determination of L-lactate // Electrochim. Acta.-1998.-43.-P. 3555-3565.
    • (1998) Electrochim. Acta. , vol.43 , pp. 3555-3565
    • Jaraba, P.1    Agui, L.2    Yanez-Sedeno, P.3    Pingarron, J.M.4
  • 30
    • 0023499982 scopus 로고
    • Strategies for the development of amperometric enzyme electrodes
    • Bartlett P. N., Whitaker R. G. Strategies for the development of amperometric enzyme electrodes // Biosensors.-1987/1988.-3.-P. 359-379.
    • (1987) Biosensors. , vol.3 , pp. 359-379
    • Bartlett, P.N.1    Whitaker, R.G.2
  • 32
    • 0000890320 scopus 로고
    • Unmediated amperometric enzyme electrodes
    • Ed. A. E. G. Cass.-Oxford: Oxford Univ. press
    • Wilson G. S., Thevenot D. R. Unmediated amperometric enzyme electrodes // Biosensors. A practical approach / Ed. A. E. G. Cass.-Oxford: Oxford Univ. press, 1990.-P. 1-17.
    • (1990) Biosensors. A practical approach , pp. 1-17
    • Wilson, G.S.1    Thevenot, D.R.2
  • 33
    • 0029165171 scopus 로고
    • A novel multienzyme electrodes for the determination of citrate
    • Gajovic N., Warsinke A., Scheller F. W. A novel multienzyme electrodes for the determination of citrate /I. Chem. Tech. Biotechnol.-1995.-63.-P. 337-344.
    • (1995) Chem. Tech. Biotechnol. , vol.63 , pp. 337-344
    • Gajovic, N.1    Warsinke, A.2    Scheller, F.W.3
  • 34
    • 84988120991 scopus 로고
    • Amperometric flowinjection determination of citric acid in food using free citrate lyase and coimmobilized oxalacetate decarboxylase and pyruvate oxidase
    • Matsumoto K, Tsukatani T., Okajima Y. Amperometric flowinjection determination of citric acid in food using free citrate lyase and coimmobilized oxalacetate decarboxylase and pyruvate oxidase // Electroanalysis.-1995.-7.-P. 527-530.
    • (1995) Electroanalysis. , vol.7 , pp. 527-530
    • Matsumoto, K.1    Tsukatani, T.2    Okajima, Y.3
  • 35
    • 0002076024 scopus 로고
    • A combination of invertase reactor and glucose-oxidase electrode for successive determination of glucose and sucrose
    • Scheller F., Karsten C. A combination of invertase reactor and glucose-oxidase electrode for successive determination of glucose and sucrose // Anal. Chim. Acta.-1983.-155.-P. 29-36.
    • (1983) Anal. Chim. Acta. , vol.155 , pp. 29-36
    • Scheller, F.1    Karsten, C.2
  • 36
    • 0030024901 scopus 로고    scopus 로고
    • Enzymatic membranes for determination of some disaccharides by means of an oxygen electrode
    • Filipak M., Fludra K, Gosciminska E. Enzymatic membranes for determination of some disaccharides by means of an oxygen electrode // Biosensors and Bioelectronics.-1996.-11-P. 355-364.
    • (1996) Biosensors and Bioelectronics. , vol.11 , pp. 355-364
    • Filipak, M.1    Fludra, K.2    Gosciminska, E.3
  • 37
    • 0027508140 scopus 로고
    • Studying the bienzyme reaction with amperometric detection for measuring maltose
    • Varadi M., Adanyi N, Nagy G., Rezessy-Szabo J. Studying the bienzyme reaction with amperometric detection for measuring maltose // Biosensors and Bioelectronics.-1993.-8.-P. 339-345.
    • (1993) Biosensors and Bioelectronics. , vol.8 , pp. 339-345
    • Varadi, M.1    Adanyi, N.2    Nagy, G.3    Rezessy-Szabo, J.4
  • 38
    • 0024992862 scopus 로고
    • Amperometric bienzyme based biosensor for the detection of lactose. Characterization and application
    • Pfeiffer D., Ralis E.V., Makower A., Scheller F. Amperometric bienzyme based biosensor for the detection of lactose. Characterization and application // J. Chem. Tech. Biotechnol.-1990.-49.-P. 255-265.
    • (1990) J. Chem. Tech. Biotechnol. , vol.49 , pp. 255-265
    • Pfeiffer, D.1    Ralis, E.V.2    Makower, A.3    Scheller, F.4
  • 40
    • 0032310427 scopus 로고    scopus 로고
    • Design and development of an amperometric biosensor for acetylcholine determination in brain microdialysates
    • Larsson N., Ruzgas T., Gorton L, Kokaia M., Kissinger P., Csoregi E. Design and development of an amperometric biosensor for acetylcholine determination in brain microdialysates // Electrochim. Acta.-1998.-43.-P. 3541-3554.
    • (1998) Electrochim. Acta. , vol.43 , pp. 3541-3554
    • Larsson, N.1    Ruzgas, T.2    Gorton, L.3    Kokaia, M.4    Kissinger, P.5    Csoregi, E.6
  • 41
    • 0016837550 scopus 로고
    • A phosphate selective electrode based on immobilized alkaline phosphatase and glucose oxidase
    • Guilbault G. G., Nanjo M. A phosphate selective electrode based on immobilized alkaline phosphatase and glucose oxidase // Anal. Chim. Acta.-1975.-78.-P. 69-80.
    • (1975) Anal. Chim. Acta. , vol.78 , pp. 69-80
    • Guilbault, G.G.1    Nanjo, M.2
  • 43
    • 0021463364 scopus 로고
    • Transport and kinetics in modified electrodes
    • Albery W. Hillman A. R. Transport and kinetics in modified electrodes // J. Electroanal. Chem.-1984.-170.-P. 27-49.
    • (1984) J. Electroanal. Chem. , vol.170 , pp. 27-49
    • Albery, W.1    Hillman, A.R.2
  • 44
    • 0033558375 scopus 로고    scopus 로고
    • Improvement of the performance of H 202 oxidation at low working potential by incorporating TTF-TCNQ into a platinum wire electrode for glucose determination
    • Quing-Shan Li, Bang-Ce Ye, Bai-Xiang Liu, Jian-Jiang Zhong. Improvement of the performance of H 202 oxidation at low working potential by incorporating TTF-TCNQ into a platinum wire electrode for glucose determination // Biosensors and Bioelectronics.-1999.-14.-P. 327-334.
    • (1999) Biosensors and Bioelectronics. , vol.14 , pp. 327-334
    • Li, Q.-S.1    Ye, B.-C.2    Liu, B.-X.3    Zhong, J.-J.4
  • 45
    • 0001872729 scopus 로고
    • Amperometric enzyme electrodes: Theory and experiment
    • Eds A. P. F. Turner, I. Karube, G. S. Wilson.-Oxford: Oxford Univ. press
    • Albery W. J., Craston D. H. Amperometric enzyme electrodes: Theory and experiment // Biosensors. Fundamentals and Applications / Eds A. P. F. Turner, I. Karube, G. S. Wilson.-Oxford: Oxford Univ. press, 1987.-P. 180-210.
    • (1987) Biosensors. Fundamentals and Applications , pp. 180-210
    • Albery, W.J.1    Craston, D.H.2
  • 46
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobilization on electrode surface by entrapment or attachment to electrochemically polymerized films. A review
    • Cosnier S. Biomolecule immobilization on electrode surface by entrapment or attachment to electrochemically polymerized films. A review // Biosensors and Bioelectronics.-1999.-14.-P. 443-456.
    • (1999) Biosensors and Bioelectronics. , vol.14 , pp. 443-456
    • Cosnier, S.1
  • 47
    • 37049110860 scopus 로고
    • An organic conductor electrode for the oxidation of NADH
    • Albery W. J., Bartlett P. N. An organic conductor electrode for the oxidation of NADH // J. Chem. Soc. Chem. Commun.-1984.-P. 234-236.
    • (1984) J. Chem. Soc. Chem. Commun. , pp. 234-236
    • Albery, W.J.1    Bartlett, P.N.2
  • 48
    • 0011868049 scopus 로고
    • Amperometric enzyme electrodes. 3. A conducting salt electrode for the oxidation of four different flavoenzymes
    • Albery W. J., Bartlett P. N, Bycroft M., Craston D. H, Driscoll B. J. Amperometric enzyme electrodes. 3. A conducting salt electrode for the oxidation of four different flavoenzymes // J. Electroanal. Chem.-1987.-218.-P. 119-126.
    • (1987) J. Electroanal. Chem. , vol.218 , pp. 119-126
    • Albery, W.J.1    Bartlett, P.N.2    Bycroft, M.3    Craston, D.H.4    Driscoll, B.J.5
  • 49
    • 0034275903 scopus 로고    scopus 로고
    • Configurations used in the design of screen-printed enzymatic biosensors. A review
    • Albareda-Sirvent M., Mercoci A., Alegret S. Configurations used in the design of screen-printed enzymatic biosensors. A review // Sensors and Actuators B.-2000.-69.-P. 153-163.
    • (2000) Sensors and Actuators B. , vol.69 , pp. 153-163
    • Albareda-Sirvent, M.1    Mercoci, A.2    Alegret, S.3
  • 50
    • 0002568854 scopus 로고
    • Theoretical methods for analysing biosensor performance
    • Ed. A. E. G. Cass.-Oxford: Oxford Univ. press
    • Eddowes M. Theoretical methods for analysing biosensor performance // Biosensors. A practical approach / Ed. A. E. G. Cass.-Oxford: Oxford Univ. press, 1990.-P. 211-263.
    • (1990) Biosensors. A practical approach , pp. 211-263
    • Eddowes, M.1
  • 54
    • 0025176638 scopus 로고
    • Evaluation des Pen-Meters zur Blutzuckerbestimmung bei ambulanten Diabetikern
    • Spinas G. A., Andre U. R., Heinzinger T., Berger W. Evaluation des Pen-Meters zur Blutzuckerbestimmung bei ambulanten Diabetikern // Schweiz. Med. Wochenschr.-1990.-120.-S. 125.
    • (1990) Schweiz. Med. Wochenschr. , vol.120 , pp. 125
    • Spinas, G.A.1    Andre, U.R.2    Heinzinger, T.3    Berger, W.4
  • 55
    • 0026337602 scopus 로고
    • Optimisation of a biosensor for in situ fermentation monitoring of glucose concentration
    • Bradley J., Schmid R. D. Optimisation of a biosensor for in situ fermentation monitoring of glucose concentration // Biosensors and Bioelectronics.-1991.-6.-P. 669-674.
    • (1991) Biosensors and Bioelectronics. , vol.6 , pp. 669-674
    • Bradley, J.1    Schmid, R.D.2
  • 56
    • 0002770174 scopus 로고    scopus 로고
    • Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix
    • Stredansky M., Pizzariello A., Stredanska S., Miertus S. Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix // Anal. Commun.-1999.-36.-P. 57-61.
    • (1999) Anal. Commun. , vol.36 , pp. 57-61
    • Stredansky, M.1    Pizzariello, A.2    Stredanska, S.3    Miertus, S.4
  • 58
    • 0343913460 scopus 로고
    • Amperometric detection of lactate: A comparison between mediated and platinised carbon electrodes
    • Eds F. Scheller, R. D. Schmid.-Weinheim: VCH Publishers
    • White S. F, Higgins I. J., D'Costa E., Bradley I., Schmid R. D. Amperometric detection of lactate: a comparison between mediated and platinised carbon electrodes // Biosensors: Fundamental technologies and application / Eds F. Scheller, R. D. Schmid.-Weinheim: VCH Publishers, 1992.-P. 403-421.
    • (1992) Biosensors: Fundamental technologies and application , pp. 403-421
    • White, S.F.1    Higgins, I.J.2    D'Costa, E.3    Bradley, I.4    Schmid, R.D.5
  • 59
    • 0000961003 scopus 로고
    • Carbon paste electrodes with incorporated lactate oxidase and mediators
    • Kulys J., Schuhmann W., Schmidt H.-L. Carbon paste electrodes with incorporated lactate oxidase and mediators // Anal. Lett-1992.-26.-P. 1011-1024.
    • (1992) Anal. Lett , vol.26 , pp. 1011-1024
    • Kulys, J.1    Schuhmann, W.2    Schmidt, H.-L.3
  • 60
    • 0001164549 scopus 로고
    • Glutamate biosensors based on electrical communication between L-glutamate oxidase and a flexible redox polymer
    • Hale P. D., Hung S.-L, Okamoto Y, Skotheim T. A. Glutamate biosensors based on electrical communication between L-glutamate oxidase and a flexible redox polymer // Anal. Lett.-1991.-24.-P. 345-356.
    • (1991) Anal. Lett. , vol.24 , pp. 345-356
    • Hale, P.D.1    Hung, S.-L.2    Okamoto, Y.3    Skotheim, T.A.4
  • 61
    • 0005432467 scopus 로고
    • Mediated enzyme electrode for the determination of L-glutamate
    • Vahjen W., Bradley I., Bilitewski U., Schmid R.D. Mediated enzyme electrode for the determination of L-glutamate // Anal. Lett.-1991.-24.-P. 1445-1452.
    • (1991) Anal. Lett. , vol.24 , pp. 1445-1452
    • Vahjen, W.1    Bradley, I.2    Bilitewski, U.3    Schmid, R.D.4
  • 63
    • 0023415311 scopus 로고
    • Catalytic oxidation of reduced nicotinamide adenine dinucleotide at hexacyanoferrate-modified nickel electrodes
    • Yon Hin B. F. Y., Lowe C. R. Catalytic oxidation of reduced nicotinamide adenine dinucleotide at hexacyanoferrate-modified nickel electrodes // Anal. Chem.-1987.-59.-P. 2111-2115.
    • (1987) Anal. Chem. , vol.59 , pp. 2111-2115
    • Yon Hin, B.F.Y.1    Lowe, C.R.2
  • 65
    • 84890830676 scopus 로고
    • Pat USA 3,838,033. W. Mindt, P. Racine, P. Schlapfer // Publ
    • Pat USA 3,838,033. Enzyme electrode / W. Mindt, P. Racine, P. Schlapfer // Publ. 1974.
    • (1974) Enzyme electrode
  • 67
    • 0024802705 scopus 로고
    • Ferrocene modified poly pyrrole with immobilised glucose oxidase and its application in amperometric glucose microsensors
    • Dicks J. M., Hattori S., Karube I., Turner A. P. F., Yokozawa T. Ferrocene modified poly pyrrole with immobilised glucose oxidase and its application in amperometric glucose microsensors // Ann. Biol. Clin.-1987.-47.-P. 607-613.
    • (1987) Ann. Biol. Clin. , vol.47 , pp. 607-613
    • Dicks, J.M.1    Hattori, S.2    Karube, I.3    Turner, A.P.F.4    Yokozawa, T.5
  • 68
    • 0027382164 scopus 로고
    • Novel approaches for the use of mediators in enzyme electrodes
    • Rosen-Margalit L, Rishpon J. Novel approaches for the use of mediators in enzyme electrodes // Biosensors and Bioelectronics.-1993.-8.-P. 315-323.
    • (1993) Biosensors and Bioelectronics. , vol.8 , pp. 315-323
    • Rosen-Margalit, L.1    Rishpon, J.2
  • 69
    • 43649098628 scopus 로고
    • Electron transfer in inorganic, organic and biological systems
    • Marcus R. A., Sutin N. Electron transfer in inorganic, organic and biological systems // Adv. Chem.-1991.-228-P. 1-13.
    • (1991) Adv. Chem. , vol.228 , pp. 1-13
    • Marcus, R.A.1    Sutin, N.2
  • 70
    • 0022004980 scopus 로고
    • Electron transfer in chemistry and biology
    • Marcus R. A., Sutin N. Electron transfer in chemistry and biology // Biochim. et biophys. acta.-1985.-811.-P. 265-322.
    • (1985) Biochim. et biophys. acta. , vol.811 , pp. 265-322
    • Marcus, R.A.1    Sutin, N.2
  • 71
    • 0000478823 scopus 로고
    • Reversible electrode reaction of cytochrome c
    • Yeh P., Kuwana T. Reversible electrode reaction of cytochrome c // Chem. Lett.-1977.-P. 1145-1148.
    • (1977) Chem. Lett. , pp. 1145-1148
    • Yeh, P.1    Kuwana, T.2
  • 72
    • 37049092929 scopus 로고
    • Novel method for the investigation of the electrochemistry of metalloproteins: Cytochrome c
    • Eddows M. J., Hill H. A. O. Novel method for the investigation of the electrochemistry of metalloproteins: cytochrome c // L Chem. Soc. Chem. Commun.-1977.-P. 770-772.
    • (1977) L Chem. Soc. Chem. Commun. , pp. 770-772
    • Eddows, M.J.1    Hill, H.A.O.2
  • 73
    • 0001432284 scopus 로고
    • Electrochemical behavior of cytochrome c3 of Desulfovibrio vulgaris, strain Miyazaki, on the mercury electrode
    • Niki K, Yagi I., Inokuchi H., Kimura K. Electrochemical behavior of cytochrome c3 of Desulfovibrio vulgaris, strain Miyazaki, on the mercury electrode // J. Amer. Chem. Soc-1979.-101.-P. 3335-3340.
    • (1979) J. Amer. Chem. Soc , vol.101 , pp. 3335-3340
    • Niki, K.1    Yagi, I.2    Inokuchi, H.3    Kimura, K.4
  • 75
    • 0000430811 scopus 로고
    • Dynamic electrochemistry of iron-sulfur proteins
    • Armstrong F. A. Dynamic electrochemistry of iron-sulfur proteins // Adv. Inorg. Chem.-1992.-38.-P. 117-163.
    • (1992) Adv. Inorg. Chem. , vol.38 , pp. 117-163
    • Armstrong, F.A.1
  • 77
    • 0002098798 scopus 로고
    • Principles of bioelectrocatalysis
    • Berezin I. V., Varfolomeev S. D. Principles of bioelectrocatalysis // Enzym. Eng.-1980.-5.-P. 95-100.
    • (1980) Enzym. Eng. , vol.5 , pp. 95-100
    • Berezin, I.V.1    Varfolomeev, S.D.2
  • 78
    • 0021479012 scopus 로고
    • Catalysis of the reduction of dioxygen at graphit electrodes coated with fungal laccase
    • Lee Chi-Woo, Gray H. B., Anson F. C, Malmstron B. G. Catalysis of the reduction of dioxygen at graphit electrodes coated with fungal laccase // J. Electroanal. Chem.-1984.-172.-P. 289-300.
    • (1984) J. Electroanal. Chem. , vol.172 , pp. 289-300
    • Lee, C.-W.1    Gray, H.B.2    Anson, F.C.3    Malmstron, B.G.4
  • 79
    • 84987471882 scopus 로고
    • An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode
    • Jonsson G., Gorton L. An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode // Electroanalysis.-1989.-1.-P. 465-468.
    • (1989) Electroanalysis. , vol.1 , pp. 465-468
    • Jonsson, G.1    Gorton, L.2
  • 81
    • 44049115172 scopus 로고
    • Direct electron transfer at horseradish peroxidase-modified colloidal gold electrodes
    • Zhao I., Henkens R. W., O'Daly J. P., Crumbliss A. L. Direct electron transfer at horseradish peroxidase-modified colloidal gold electrodes // J. Electroanal. Chem.-1992.-327.-P. 109-119.
    • (1992) J. Electroanal. Chem. , vol.327 , pp. 109-119
    • Zhao, I.1    Henkens, R.W.2    O'Daly, J.P.3    Crumbliss, A.L.4
  • 82
    • 0001091998 scopus 로고
    • Mediatorless horseradish peroxidase enzyme electrodes based on activated carbon: Potential application to specific binding assay
    • Ho W. O., Athey D., McNeil C I., Hager H J., Evans G P., Mullen W. H. Mediatorless horseradish peroxidase enzyme electrodes based on activated carbon: potential application to specific binding assay // J. Electroanal. Chem.-1993.-351.-P. 185-197.
    • (1993) J. Electroanal. Chem. , vol.351 , pp. 185-197
    • Ho, W.O.1    Athey, D.2    McNeil, C.I.3    Hager, H.J.4    Evans, G.P.5    Mullen, W.H.6
  • 83
    • 58149364211 scopus 로고
    • Kinetic models of horseradish peroxidase action on a graphite electrode
    • Ruzgas T., Gorton L, Emneus J., Marko-Verga G. Kinetic models of horseradish peroxidase action on a graphite electrode // J. Electroanal. Chem.-1995-391.-P. 41-49.
    • (1995) J. Electroanal. Chem. , vol.391 , pp. 41-49
    • Ruzgas, T.1    Gorton, L.2    Emneus, J.3    Marko-Verga, G.4
  • 84
    • 0028929261 scopus 로고
    • Direct electron transfer bioelectronic interfaces: Application to clinical analysis
    • McNeil C. J., Athey D., Ho W. O. Direct electron transfer bioelectronic interfaces: application to clinical analysis // Biosensors and Bioelectronics.-1995.-10.-P. 75-83.
    • (1995) Biosensors and Bioelectronics. , vol.10 , pp. 75-83
    • McNeil, C.J.1    Athey, D.2    Ho, W.O.3
  • 85
    • 33845281191 scopus 로고
    • Fast interfacial electron transfer between cytochrome c peroxidase and graphite electrodes promoted by aminoglycosides: Novel electroenzymatic catalysis of H 202 reaction
    • Armstrong F. A., Lannon A. M. Fast interfacial electron transfer between cytochrome c peroxidase and graphite electrodes promoted by aminoglycosides: novel electroenzymatic catalysis of H 202 reaction // J. Amer. Chem. Soc-1987.-109.-P. 7211-7212.
    • (1987) J. Amer. Chem. Soc , vol.109 , pp. 7211-7212
    • Armstrong, F.A.1    Lannon, A.M.2
  • 86
    • 0001598453 scopus 로고
    • Electrocatalytic reduction of hydrogen peroxide via direct electron transfer from pyrolytic graphite electrodes to irreversibly adsorbed cytochrome c peroxidase
    • Paddok R. M., Bowden E. F. Electrocatalytic reduction of hydrogen peroxide via direct electron transfer from pyrolytic graphite electrodes to irreversibly adsorbed cytochrome c peroxidase // J. Electroanal. Chem.-1989.-260.-P. 487-494.
    • (1989) J. Electroanal. Chem. , vol.260 , pp. 487-494
    • Paddok, R.M.1    Bowden, E.F.2
  • 87
    • 0342997127 scopus 로고
    • The electrocatalytic enzyme function on adsorbed cytochrome c peroxidase on pyrolytic graphite
    • Scott D. L, Paddock R. M., Bowden E. F. The electrocatalytic enzyme function on adsorbed cytochrome c peroxidase on pyrolytic graphite // J. Electroanal. Chem.-1992.-341.-P. 307-321.
    • (1992) J. Electroanal. Chem. , vol.341 , pp. 307-321
    • Scott, D.L.1    Paddock, R.M.2    Bowden, E.F.3
  • 88
    • 0012967523 scopus 로고
    • Direct electrochemical communication between chemically modified enzymes and metal electrodes. 1. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme
    • Degani Y., Heller A. Direct electrochemical communication between chemically modified enzymes and metal electrodes. 1. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme // J. Phys. Chem.-1987.-91.-P. 1285-1289.
    • (1987) J. Phys. Chem. , vol.91 , pp. 1285-1289
    • Degani, Y.1    Heller, A.2
  • 89
    • 11944262355 scopus 로고
    • Electrical wiring of redox enzymes
    • Heller A. Electrical wiring of redox enzymes // Acc. Chem. Res.-1990.-23.-P. 128-134.
    • (1990) Acc. Chem. Res. , vol.23 , pp. 128-134
    • Heller, A.1
  • 90
    • 0025366526 scopus 로고
    • Crosslinked redox gels containing glucose oxidase for amperometric biosensor application
    • Gregg B. A., Heller A. Crosslinked redox gels containing glucose oxidase for amperometric biosensor application // Anal. Chem.-1990.-62.-P. 258-263.
    • (1990) Anal. Chem. , vol.62 , pp. 258-263
    • Gregg, B.A.1    Heller, A.2
  • 91
    • 33750428427 scopus 로고
    • Electrical connection of enzyme redox centers to electrodes
    • Heller A. Electrical connection of enzyme redox centers to electrodes // J. Phys. Chem.-1992.-96.-P. 3579-3587.
    • (1992) J. Phys. Chem. , vol.96 , pp. 3579-3587
    • Heller, A.1
  • 92
    • 0031127804 scopus 로고    scopus 로고
    • Electrical contact of redox enzymes with electrodes: Novel approaches for amperometric biosensors
    • Katz E., Heleg-Shabtai V., Willner B., Willner L, Buckmann A. Electrical contact of redox enzymes with electrodes: novel approaches for amperometric biosensors // Bioelectrochem. Bioenerg.-1997.-42.-P. 95-104.
    • (1997) Bioelectrochem. Bioenerg. , vol.42 , pp. 95-104
    • Katz, E.1    Heleg-Shabtai, V.2    Willner, B.3    Willner, L.4    Buckmann, A.5
  • 93
    • 0003169214 scopus 로고
    • Biosensors and Bioelectronics
    • Eds H. J. Rehm, G. Reed.-Weinheim: VCH Verlagsgesellschaft
    • Schmid R. D., Karube I. Biosensors and Bioelectronics // Biotechnology / Eds H. J. Rehm, G. Reed.-Weinheim: VCH Verlagsgesellschaft, 1988.-Vol. 66.-P. 317-365.
    • (1988) Biotechnology , vol.66 , pp. 317-365
    • Schmid, R.D.1    Karube, I.2
  • 94
    • 84911224812 scopus 로고
    • MediSense Inc. Product Information.-New York
    • MediSense Inc. Blood Glucose Sensor Electrodes // Product Information.-New York, 1990.
    • (1990) Blood Glucose Sensor Electrodes
  • 95
    • 0029166546 scopus 로고
    • Improving enzyme electrode contacts by redox modification of cofactors
    • Riklin A., Katz E., Willner I., Stocker A., Buckmann A. F. Improving enzyme electrode contacts by redox modification of cofactors // Nature.-1995.-376.-P. 672-675.
    • (1995) Nature. , vol.376 , pp. 672-675
    • Riklin, A.1    Katz, E.2    Willner, I.3    Stocker, A.4    Buckmann, A.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.