메뉴 건너뛰기




Volumn 134, Issue 3, 2012, Pages

Syrinx fluid transport: Modeling pressure-wave-induced flux across the spinal pial membrane

Author keywords

coaxial elastic tubes; Darcy's law; perivascular flow; syringomyelia; wave propagation

Indexed keywords

DARCY'S LAW; ELASTIC TUBES; FLOW OBSTRUCTION; FLUID EXCHANGE; FLUID TRANSPORT; FLUID-FILLED CAVITY; HOOP STRESS; INERTIAL FORCES; INTERSTITIAL FLOW; PERIVASCULAR FLOW; POROELASTIC; PRESSURE WAVE PROPAGATION; PRESSURE WAVES; SPINAL CANALS; SPINAL CORDS; SUBARACHNOID SPACES; SYRINGOMYELIA; TIME-SCALES;

EID: 84859912611     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4005849     Document Type: Article
Times cited : (21)

References (58)
  • 2
    • 0037365738 scopus 로고    scopus 로고
    • Biologic aspects of flexor tendon laceration and repair
    • Levine, D. N., 2004, The Pathogenesis of Syringomyelia Associated With Lesions at the Foramen Magnum: A Critical Review of Existing Theories and Proposal of a New Hypothesis., J. Neurol. Sci., 220 (1-2), pp. 3-21. (Pubitemid 36538767)
    • (2003) Journal of Bone and Joint Surgery - Series A , vol.85 , Issue.3 , pp. 539-550
    • Beredjiklian, P.K.1
  • 3
    • 0019788437 scopus 로고
    • The importance of controlled passive mobilization on flexor tendon healing
    • Batzdorf, U., Klekamp, J., and Johnson, J. P., 1998, A Critical Appraisal of Syrinx Cavity Shunting Procedures., J. Neurosurg., 89 (3), pp. 382-388. (Pubitemid 12207311)
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , Issue.6 , pp. 615-622
    • Woo, S.L.Y.1    Gelberman, R.H.2    Cobb, N.G.3
  • 5
    • 4444325444 scopus 로고    scopus 로고
    • Functional efficacy of tendon repair processes
    • DOI 10.1146/annurev.bioeng.6.040803.140240
    • Speer, M. C., Enterline, D. S., Mehltretter, L., Hammock, P., Joseph, J., Dickerson, M., Ellenbogen, R. G., Milhorat, T. H., Hauser, M. A., and George, T. M., 2003, Chiari Type I Malformation With or Without Syringomyelia: Prevalence and Genetics., J. Genet. Couns., 12 (4), pp. 297-311. (Pubitemid 39209501)
    • (2004) Annual Review of Biomedical Engineering , vol.6 , pp. 303-329
    • Butler, D.L.1    Juncosa, N.2    Dressler, M.R.3
  • 6
  • 8
    • 18644366547 scopus 로고    scopus 로고
    • The role of fiber-matrix interactions in a nonlinear fiber-reinforced strain energy model of tendon
    • DOI 10.1115/1.1865212
    • Yoshizawa, H., 2002, Presidential Address: Pathomechanism of Myelopathy and Radiculopathy from the Viewpoint of Blood Flow and Cerebrospinal Fluid Flow Including a Short Historical Review., Spine, 27 (12), pp. 1255-1263. (Pubitemid 40663978)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.2 , pp. 345-350
    • Guerin, H.A.L.1    Elliott, D.M.2
  • 9
    • 35148867185 scopus 로고    scopus 로고
    • Csf pathways: A review
    • Brodbelt, A. R. and Stoodley, M. A., 2007, CSF Pathways: A Review., Br. J. Neurosurg., 21 (5), pp. 510-520.
    • (2007) Br. J. Neurosurg. , vol.21 , Issue.5 , pp. 510-520
    • Brodbelt, A.R.1    Stoodley, M.A.2
  • 10
    • 3042713511 scopus 로고    scopus 로고
    • Characterisation of proteoglycans and their catabolic products in tendon and explant cultures of tendon
    • DOI 10.1016/j.matbio.2004.03.004, PII S0945053X04000332
    • Brodbelt, A. R., 2003, Investigations in Post-traumatic Syringomyelia., PhD thesis, Prince of Wales Medical Research Institute, University of New South Wales, Sydney, Australia. (Pubitemid 38891526)
    • (2004) Matrix Biology , vol.23 , Issue.2 , pp. 127-140
    • Samiric, T.1    Ilic, M.Z.2    Handley, C.J.3
  • 15
    • 0033233166 scopus 로고    scopus 로고
    • Growing C57B1/6 mice increase whole bone mechanical properties by increasing geometric and material properties
    • Oldfield, E. H., Murasko, K., Shawker, T. H., and Patronas, N. H., 1994, Pathophysiology of Syringomyelia Associated With Chiari I Malformation of the Cerebellar Tonsils. Implications for Diagnosis and Treatment., J. Neurosurg., 80, pp. 3-15. (Pubitemid 30026966)
    • (1999) Journal of Bone and Mineral Research , vol.14 , Issue.12 , pp. 2159-2166
    • Brodt, M.D.1    Ellis, C.B.2    Silva, M.J.3
  • 16
    • 0033499617 scopus 로고    scopus 로고
    • The presyrinx' state: A reversible myelopathic condition that may precede syringomyelia
    • Fischbein, N. J., Dillon, W. P., Cobbs, C., and Weinstein, P. R., 1999, The Presyrinx' State: A Reversible Myelopathic Condition That May Precede Syringomyelia., Am. J. Neuroradiol., 20, pp. 7-20.
    • (1999) Am. J. Neuroradiol. , vol.20 , pp. 7-20
    • Fischbein, N.J.1    Dillon, W.P.2    Cobbs, C.3    Weinstein, P.R.4
  • 17
    • 21244435670 scopus 로고    scopus 로고
    • Altered subarachnoid space compliance and fluid flow in an animal model of posttraumatic syringomyelia
    • Brodbelt, A. R., Stoodley, M. A., Watling, A. M., Tu, J., Burke, S., and Jones, N. R., 2003, Altered subarachnoid space compliance and fluid flow in an animal model of posttraumatic syringomyelia. Spine, 28 (20), pp. E413-E419.
    • (2003) Spine , vol.28 , Issue.20
    • Brodbelt, A.R.1    Stoodley, M.A.2    Watling, A.M.3    Tu, J.4    Burke, S.5    Jones, N.R.6
  • 18
    • 0742323978 scopus 로고    scopus 로고
    • Pressure wave propagation in fluid-filled co-axial elastic tubes-part 2: Mechanisms for the pathogenesis of syringomyelia
    • Carpenter, P., Berkouk, K., and Lucey, A., 2003, Pressure Wave Propagation in Fluid-Filled Co-Axial Elastic Tubes-Part 2: Mechanisms for the Pathogenesis of Syringomyelia., ASME J. Biomech. Eng., 125 (6), pp. 857-863.
    • (2003) ASME J. Biomech. Eng. , vol.125 , Issue.6 , pp. 857-863
    • Carpenter, P.1    Berkouk, K.2    Lucey, A.3
  • 19
    • 0021428157 scopus 로고
    • An analysis of the unconfined compression of articular cartilage
    • Martin, B. A., Kalata, W., Loth, F., and Royston, T. J., 2005, Syringomyelia Hydrodynamics: An in vitro Study Based on in vivo Measurements., ASME J. Biomech. Eng., 127 (7), pp. 1110-1120. (Pubitemid 14022391)
    • (1984) Journal of Biomechanical Engineering , vol.106 , Issue.2 , pp. 165-173
    • Armstrong, C.G.1    Lai, W.M.2    Mow, V.C.3
  • 20
    • 0031238905 scopus 로고    scopus 로고
    • Estimating the effective Young's modulus of soft tissues from indentation tests - Nonlinear finite element analysis of effects of friction and large deformation
    • DOI 10.1016/S1350-4533(97)00017-9, PII S1350453397000179
    • Bertram, C. D., 2010, Evaluation by Fluid/Structure-Interaction Spinal-Cord Simulation of the Effects of Subarachnoid-Space Stenosis on an Adjacent Syrinx., ASME. J. Biomech. Eng., 132 (6), p. 061009. (Pubitemid 27461590)
    • (1997) Medical Engineering and Physics , vol.19 , Issue.6 , pp. 512-517
    • Zhang, M.1    Zheng, Y.P.2    Mak, A.F.T.3
  • 21
    • 0023161999 scopus 로고
    • Biphasic indentation of articular cartilage - I. Theoretical analysis
    • DOI 10.1016/0021-9290(87)90036-4
    • Lockey, P., Poots, G., and Williams, B., 1975, Theoretical Aspects of the Attenuation of Pressure Pulses Within Cerebrospinal Fluid Pathways., Med. Biol. Eng. Comput., 13, pp. 861-869. (Pubitemid 17654722)
    • (1987) Journal of Biomechanics , vol.20 , Issue.7 , pp. 703-714
    • Mak, A.F.1    Lai, W.M.2    Mow, V.C.3
  • 22
    • 0742323979 scopus 로고    scopus 로고
    • Pressure wave propagation in fluid-filled co-axial elastic tubes-part 1: Basic theory
    • Berkouk, K., Carpenter, P. W., and Lucey, A. D., 2003, Pressure Wave Propagation in Fluid-Filled Co-Axial Elastic Tubes-Part 1: Basic Theory., ASME J. Biomech. Eng., 125 (6), pp. 852-856.
    • (2003) ASME J. Biomech. Eng. , vol.125 , Issue.6 , pp. 852-856
    • Berkouk, K.1    Carpenter, P.W.2    Lucey, A.D.3
  • 24
    • 0022470549 scopus 로고
    • Extracellular compartments in tendon morphogenesis: Collagen fibril, bundle, and macroaggregate formation
    • Bertram, C. D., Bilston, L. E., and Stoodley, M. A., 2008, Tensile Radial Stress in the Spinal Cord Related to Arachnoiditis or Tethering: A Numerical Model., Med. Biol. Eng. Comput., 46, pp. 701-707. (Pubitemid 16067007)
    • (1986) Journal of Cell Biology , vol.103 , Issue.1 , pp. 231-240
    • Birk, D.E.1    Trelstad, R.L.2
  • 25
    • 63449133397 scopus 로고    scopus 로고
    • A coaxial tube model of the cerebrospinal fluid pulse propagation in the spinal column
    • Cirovic, S., 2009, A Coaxial Tube Model of the Cerebrospinal Fluid Pulse Propagation in the Spinal Column., ASME J. Biomech. Eng., 131 (2), p. 021008.
    • (2009) ASME J. Biomech. Eng. , vol.131 , Issue.2 , pp. 021008
    • Cirovic, S.1
  • 26
    • 79955857675 scopus 로고    scopus 로고
    • The influence of coughing on cerebrospinal fluid pressure in an in vitro syringomyelia model with spinal subarachnoid space stenosis
    • Martin, B. A. and Loth, F., 2009. The Influence of Coughing on Cerebrospinal Fluid Pressure in an in vitro Syringomyelia Model With Spinal Subarachnoid Space Stenosis., Cerebrospinal Fluid Res., 6 (1), p. 17.
    • (2009) Cerebrospinal Fluid Res. , vol.6 , Issue.1 , pp. 17
    • Martin, B.A.1    Loth, F.2
  • 27
    • 0022887540 scopus 로고
    • Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus
    • Bertram, C. D., 2009, A Numerical Investigation of Waves Propagating in the Spinal Cord and Subarachnoid Space in the Presence of a Syrinx., J. Fluids. Struct., 25, pp. 1189-1205. (Pubitemid 17227720)
    • (1986) Journal of Orthopaedic Research , vol.4 , Issue.4 , pp. 379-392
    • Akizuki, S.1    Mow, V.C.2    Muller, F.3
  • 28
    • 77958588951 scopus 로고    scopus 로고
    • Spinal subarachnoid space pressure measurements in an in vitro spinal stenosis model: Implications on syringomyelia theories
    • Martin, B. A., Labuda, R., Royston, T. J., Oshinski, J. N., Iskandar, B., and Loth, F., 2010, Spinal Subarachnoid Space Pressure Measurements in an in vitro Spinal Stenosis Model: Implications on Syringomyelia Theories., ASME J. Biomech. Eng., 132 (11), p. 111007.
    • (2010) ASME J. Biomech. Eng. , vol.132 , Issue.11 , pp. 111007
    • Martin, B.A.1    Labuda, R.2    Royston, T.J.3    Oshinski, J.N.4    Iskandar, B.5    Loth, F.6
  • 29
    • 2442676612 scopus 로고    scopus 로고
    • Arterial pulsation-driven cerebrospinal fluid flow in the perivascular space: A computational model
    • Bilston, L. E., Fletcher, D. F., Brodbelt, A. R., and Stoodley, M. A., 2003, Arterial Pulsation-Driven Cerebrospinal Fluid Flow in the Perivascular Space: A Computational Model., Comput. Methods. Biomech. Biomed. Eng., 6 (4), pp. 235-241.
    • (2003) Comput. Methods. Biomech. Biomed. Eng. , vol.6 , Issue.4 , pp. 235-241
    • Bilston, L.E.1    Fletcher, D.F.2    Brodbelt, A.R.3    Stoodley, M.A.4
  • 30
    • 77950647447 scopus 로고    scopus 로고
    • The influence of the relative timing of arterial and subarachnoid space pulse waves on spinal perivascular cerebrospinal fluid flow as a possible factor in syrinx developments
    • Bilston, L. E., Stoodley, M. A., and Fletcher, D. F., 2010, The Influence of the Relative Timing of Arterial and Subarachnoid Space Pulse Waves on Spinal Perivascular Cerebrospinal Fluid Flow as a Possible Factor in Syrinx Developments., J. Neurosurg., 112 (4), pp. 808-813.
    • (2010) J. Neurosurg. , vol.112 , Issue.4 , pp. 808-813
    • Bilston, L.E.1    Stoodley, M.A.2    Fletcher, D.F.3
  • 31
    • 0031060035 scopus 로고    scopus 로고
    • The state of tissue hydration determines the strain-rate-sensitive stiffness of human patellar tendon
    • DOI 10.1016/S0021-9290(96)00108-X, PII S002192909600108X
    • Elliott, N. S. J., Lockerby, D. A., and Brodbelt, A. R., 2011, A Lumped-Parameter Model of the Cerebrospinal System for Investigating Arterial-Driven Flow in Posttraumatic Syringomyelia., Med. Eng. Phys., 33, pp. 874-882. (Pubitemid 26421558)
    • (1997) Journal of Biomechanics , vol.30 , Issue.1 , pp. 79-81
    • Haut, T.L.1    Haut, R.C.2
  • 32
    • 67049137991 scopus 로고    scopus 로고
    • The pathogenesis of syringomyelia: A re-evaluation of the elastic-jump hypothesis
    • Elliott, N. S. J., Lockerby, D. A., and Brodbelt, A. R., 2009, The Pathogenesis of Syringomyelia: A Re-Evaluation of the Elastic-Jump Hypothesis., ASME J. Biomech. Eng., 131 (4), p. 044503.
    • (2009) ASME J. Biomech. Eng. , vol.131 , Issue.4 , pp. 044503
    • Elliott, N.S.J.1    Lockerby, D.A.2    Brodbelt, A.R.3
  • 34
    • 11044222473 scopus 로고    scopus 로고
    • Viscoelastic properties of the human medial collateral ligament under longitudinal, transverse and shear loading
    • DOI 10.1016/j.orthres.2004.06.002, PII S0736026604001469
    • Zauderer, E., 2006, Partial Differential Equations of Applied Mathematics, Pure and Applied Mathematics, third ed., Wiley, New York. (Pubitemid 40045079)
    • (2005) Journal of Orthopaedic Research , vol.23 , Issue.1 , pp. 67-76
    • Bonifasi-Lista, C.1    Lake, S.P.2    Small, M.S.3    Weiss, J.A.4
  • 35
    • 35548979581 scopus 로고    scopus 로고
    • Vectorized adaptive quadrature in matlab
    • Shampine, L. F., 2008, Vectorized Adaptive Quadrature in MATLAB., J. Comput. Appl. Math., 211 (2), pp. 131-140.
    • (2008) J. Comput. Appl. Math. , vol.211 , Issue.2 , pp. 131-140
    • Shampine, L.F.1
  • 38
    • 3042553012 scopus 로고    scopus 로고
    • Mechanical properties and function of the spinal pia mater
    • Ozawa, H., Matsumoto, T., Ohashi, T., Sato, M., and Kokuban, S., 2004, Mechanical Properties and Function of the Spinal Pia Mater., J. Neurosurg., 1, pp. 122-127.
    • (2004) J. Neurosurg. , vol.1 , pp. 122-127
    • Ozawa, H.1    Matsumoto, T.2    Ohashi, T.3    Sato, M.4    Kokuban, S.5
  • 40
    • 0015992737 scopus 로고
    • Scanning electron microscopy of the subarachnoid space in the dog: I. Spinal cord levels
    • Cloyd, M. W. and Low, F. N., 1974, Scanning Electron Microscopy of the Subarachnoid Space in the Dog: I. Spinal Cord Levels., J. Comp. Neurol., 153 (4), pp. 325-368.
    • (1974) J. Comp. Neurol. , vol.153 , Issue.4 , pp. 325-368
    • Cloyd, M.W.1    Low, F.N.2
  • 42
    • 33644609166 scopus 로고    scopus 로고
    • A hydroelastic model of hydrocephalus
    • Smillie, A., Sobey, I., and Molnar, Z., 2005, A Hydroelastic Model of Hydrocephalus., J. Fluid. Mech., 539, pp. 417-443.
    • (2005) J. Fluid. Mech. , vol.539 , pp. 417-443
    • Smillie, A.1    Sobey, I.2    Molnar, Z.3
  • 43
    • 0036027060 scopus 로고    scopus 로고
    • Wave propagation in a system of coaxial tubes filled with incompressible media: A model of pulse transmission in the intracranial arteries
    • DOI 10.1006/jfls.2002.0457
    • Cirovic, S., Walsh, C., and Fraser, W. D., 2002, Wave Propagation in a System of Coaxial Tubes Flled With Incompressible Media: A Model of Pulse Transmission in the Intracranial Arteries., J. Fluids. Struct., 16 (8), pp. 1029-1049. (Pubitemid 36093500)
    • (2002) Journal of Fluids and Structures , vol.16 , Issue.8 , pp. 1029-1049
    • Cirovic, S.1    Walsh, C.2    Fraser, W.D.3
  • 45
    • 0035089444 scopus 로고    scopus 로고
    • Hydrodynamic modeling of cerebrospinal fluid motion within the spinal cavity
    • DOI 10.1115/1.1336144
    • Loth, F., Yardimci, M. A., and Alperin, N., 2001, Hydrodynamic Model of Cerebrospinal Fluid Motion Within the Spinal Cavity., ASME J. Biomech. Eng., 123, pp. 71-79. (Pubitemid 32202582)
    • (2001) Journal of Biomechanical Engineering , vol.123 , Issue.1 , pp. 71-79
    • Loth, F.1    Yardimci, M.A.2    Alperin, N.3
  • 47
    • 33645717591 scopus 로고    scopus 로고
    • Effect of anatomical fine structure on the flow of cerebrospinal fluid in the spinal subarachnoid space
    • Stockman, H. W., 2006, Effect of Anatomical Fine Structure on the Flow of Cerebrospinal Fluid in the Spinal Subarachnoid Space., ASME J. Biomech. Eng., 128, pp. 106-114.
    • (2006) ASME J. Biomech. Eng. , vol.128 , pp. 106-114
    • Stockman, H.W.1
  • 48
    • 0019626921 scopus 로고
    • Poroelasticity equations derived from microstructure
    • Burridge, R. and Keller, J. B., 1981, Poroelasticity Equations Derived From Microstructure., J. Acoust. Soc. Am., 70 (4), pp. 1140-1146.
    • (1981) J. Acoust. Soc. Am. , vol.70 , Issue.4 , pp. 1140-1146
    • Burridge, R.1    Keller, J.B.2
  • 49
    • 0036801284 scopus 로고    scopus 로고
    • A spinal cord surrogate with nanoscale porosity for in vitro simulations of restorative neurosurgical techniques
    • DOI 10.1088/0957-4484/13/5/308, PII S0957448402399045
    • Gillies, G. T., Wilhelm, T. D., Humphrey, J. A. C., Fillmore, H. L., Holloway, K. L., and Broaddus, W. C., 2002, A Spinal Cord Surrogate With Nanoscale Porosity for in vitro Simulations of Restorative Neurosurgical Techniques., Nanotechnology, 13, pp. 587-591. (Pubitemid 35263784)
    • (2002) Nanotechnology , vol.13 , Issue.5 , pp. 587-591
    • Gillies, G.T.1    Wilhelm, T.D.2    Humphrey, J.A.C.3    Fillmore, H.L.4    Holloway, K.L.5    Broaddus, W.C.6
  • 50
    • 0030030502 scopus 로고    scopus 로고
    • The mechanical properties of the human cervical spinal cord in vitro
    • Bilston, L. E. and Thibault, L. E., 1996, The Mechanical Properties of the Human Cervical Spinal Cord in vitro., Ann. Biomed. Eng., 24 (1), pp. 67-74.
    • (1996) Ann. Biomed. Eng. , vol.24 , Issue.1 , pp. 67-74
    • Bilston, L.E.1    Thibault, L.E.2
  • 51
    • 0015506325 scopus 로고
    • Pathogenesis of syringomyelia
    • Ball, M. J. and Dayan, A. D., 1972, Pathogenesis of Syringomyelia., Lancet, ii, pp. 799-801.
    • (1972) Lancet , vol.2 , pp. 799-801
    • Ball, M.J.1    Dayan, A.D.2
  • 52
    • 0032907186 scopus 로고    scopus 로고
    • Cerebrospinal fluid flow in an animal model of noncommunicating syringomyelia
    • Stoodley, M. A., Gutschmidt, B., and Jones, N. R., 1999, Cerebrospinal Fluid Flow in an Animal Model of Noncommunicating Syringomyelia., Neurosurgery, 44 (5), pp. 1065-1075.
    • (1999) Neurosurgery , vol.44 , Issue.5 , pp. 1065-1075
    • Stoodley, M.A.1    Gutschmidt, B.2    Jones, N.R.3
  • 53
    • 77956725039 scopus 로고
    • Theory of propagation of elastic waves in a fluid-saturated porous solid. I. Low-frequency range
    • Biot, M. A., 1956, Theory of Propagation of Elastic Waves in a Fluid-Saturated Porous Solid. I. Low-Frequency Range., J. Acoust. Soc. Am., 28 (2), pp. 168-178.
    • (1956) J. Acoust. Soc. Am. , vol.28 , Issue.2 , pp. 168-178
    • Biot, M.A.1
  • 54
    • 0033963675 scopus 로고    scopus 로고
    • Brain biomechanics: Mathematical modeling of hydrocephalus
    • Tenti, G., Drake, J., and Sivaloganathan, S., 2000, Brain Biomechanics: Mathematical Modelling of Hydrocephalus., Neurol. Res., 22, pp. 19-24. (Pubitemid 30075144)
    • (2000) Neurological Research , vol.22 , Issue.1 , pp. 19-24
    • Tenti, G.1    Drake, J.M.2    Sivaloganathan, S.3
  • 55
    • 84859907105 scopus 로고    scopus 로고
    • A porous finite element model of the motion of the spinal cord
    • Volume: Computational Methods, edited by C. Constanda and M. E. Pérez, Springer, New York
    • Harris, P. J. and Hardwidge, C., 2010, A Porous Finite Element Model of the Motion of the Spinal Cord., Integral Methods in Science and Engineering, Volume 2: Computational Methods, edited by, C. Constanda, and, M. E. Pérez, Springer, New York, pp. 193-201.
    • (2010) Integral Methods in Science and Engineering , vol.2 , pp. 193-201
    • Harris, P.J.1    Hardwidge, C.2
  • 57
    • 0038710535 scopus 로고    scopus 로고
    • Post-traumatic syringomyelia: A review
    • DOI 10.1016/S0967-5868(02)00326-0
    • Brodbelt, A. R. and Stoodley, M. A., 2003, Post-Traumatic Syringomyelia: A Review., J. Clin. Neurosci., 10 (4), pp. 401-408. (Pubitemid 36876645)
    • (2003) Journal of Clinical Neuroscience , vol.10 , Issue.4 , pp. 401-408
    • Brodbelt, A.R.1    Stoodley, M.A.2
  • 58
    • 0030720081 scopus 로고    scopus 로고
    • Intramedullary pressure in syringomyelia: Clinical and pathophysiological correlates of syrinx distension
    • Milhorat, T. H., Capocelli, A. L., Kotzen, R. M., Bolognese, P., Heger, I. M., and Cottrell, J. E., 1997, Intramedullary Pressure in Syringomyelia: Clinical and Pathophysiological Correlates of Syrinx Distension., Neurosurgery, 41 (5), pp. 1102-1110.
    • (1997) Neurosurgery , vol.41 , Issue.5 , pp. 1102-1110
    • Milhorat, T.H.1    Capocelli, A.L.2    Kotzen, R.M.3    Bolognese, P.4    Heger, I.M.5    Cottrell, J.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.