-
1
-
-
21644487773
-
Laparoscopic surgery: Current status, issues and future developments
-
Cuschieri A. Laparoscopic surgery: current status, issues and future developments. Surgeon 2005; 3: 125-38.
-
(2005)
Surgeon
, vol.3
, pp. 125-138
-
-
Cuschieri, A.1
-
4
-
-
0024701576
-
A new rod-lens relay system off ering improved image quality
-
Dobson SJ, Hopkins HH. A new rod-lens relay system off ering improved image quality. J Phys E Sci Instrum 1989; 22: 450.
-
(1989)
J Phys e Sci Instrum
, vol.22
, pp. 450
-
-
Dobson, S.J.1
Hopkins, H.H.2
-
8
-
-
0026155737
-
A 2 million pixel FIT-CCD image sensor for HDTV camera systems
-
Yamagishi M, Negishi M, Yamada H, et al. A 2 million pixel FIT-CCD image sensor for HDTV camera systems. IEEE Trans Electron Devices 1991; 38: 976-80.
-
(1991)
IEEE Trans Electron Devices
, vol.38
, pp. 976-980
-
-
Yamagishi, M.1
Negishi, M.2
Yamada, H.3
-
11
-
-
0007644530
-
Eye movement control during inspection of words under conditions of pulsating illumination
-
Kennedy A, Murray WS. Eye movement control during inspection of words under conditions of pulsating illumination. Eur J Cognitive Psychol 1996; 8: 831-43.
-
(1996)
Eur J Cognitive Psychol
, vol.8
, pp. 831-843
-
-
Kennedy, A.1
Murray, W.S.2
-
12
-
-
14644439736
-
The history of liquid-crystal displays
-
Kawamoto, H. The history of liquid-crystal displays. Proc IEEE 2001; 90: 460-500.
-
(2001)
Proc. IEEE
, vol.90
, pp. 460-500
-
-
Kawamoto, H.1
-
13
-
-
37049097142
-
Synthesis of electrically conducting organic polymers: Halogen derivatives of polyacetylene, (CH) x
-
Shirakawa H, Louis EJ, MacDiarmid AG, Chiang CK, Heeger AJ. Synthesis of electrically conducting organic polymers: halogen derivatives of polyacetylene, (CH)x. J Chem Soc Chem Commun 1977; 578-80.
-
(1977)
J Chem Soc Chem Commun
, pp. 578-580
-
-
Shirakawa, H.1
Louis, E.J.2
MacDiarmid, A.G.3
Chiang, C.K.4
Heeger, A.J.5
-
14
-
-
0031926852
-
Task performance in endoscopic surgery is influenced by location of image display
-
Hanna GB, Shimi SM, Cuschieri A. Task performance in endoscopic surgery is influenced by location of image display. Ann Surg 1998; 227: 481-84.
-
(1998)
Ann Surg
, vol.227
, pp. 481-484
-
-
Hanna, G.B.1
Shimi, S.M.2
Cuschieri, A.3
-
16
-
-
0018647832
-
Cancer therapy with ultrasound: A historical review
-
Kremkau FW. Cancer therapy with ultrasound: a historical review. J Clin Ultrasound 1979; 7: 287-300.
-
(1979)
J Clin Ultrasound
, vol.7
, pp. 287-300
-
-
Kremkau, F.W.1
-
18
-
-
44149102122
-
Ultrasound, cavitation bubbles and their interaction with cells
-
Wu J, Nyborg WL. Ultrasound, cavitation bubbles and their interaction with cells. Adv Drug Deliv Rev 2008; 60: 1103-16.
-
(2008)
Adv Drug Deliv Rev
, vol.60
, pp. 1103-1116
-
-
Wu, J.1
Nyborg, W.L.2
-
19
-
-
0034931395
-
A review of therapeutic ultrasound: Effectiveness studies
-
Robertson VJ, Baker KG. A review of therapeutic ultrasound: effectiveness studies. Phys Ther 2001; 81: 1339-50.
-
(2001)
Phys Ther
, vol.81
, pp. 1339-1350
-
-
Robertson, V.J.1
Baker, K.G.2
-
20
-
-
0034946544
-
A review of therapeutic ultrasound: Biophysical effects
-
Baker KG, Robertson VJ, Duck FA. A review of therapeutic ultrasound: biophysical effects. Phys Ther 2001; 81: 1350-58.
-
(2001)
Phys Ther
, vol.81
, pp. 1350-1358
-
-
Baker, K.G.1
Robertson, V.J.2
Duck, F.A.3
-
21
-
-
54049139369
-
Ultrasound hyperthermia and the prediction of heating
-
Duck FA, Baker AC, Starritt HC, eds Bristol: IOP Publishing
-
Hand JW. Ultrasound hyperthermia and the prediction of heating. In: Duck FA, Baker AC, Starritt HC, eds. Ultrasound in Medicine. Bristol: IOP Publishing, 1998.
-
(1998)
Ultrasound in Medicine
-
-
Hand, J.W.1
-
22
-
-
27744493451
-
Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: Initial comparison with MRI
-
Curiel L, Souchon R, Rouvière O, Gelet A, Chapelon J Y. Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI. Ultrasound Med Biol 2005; 31: 1461-68.
-
(2005)
Ultrasound Med Biol
, vol.31
, pp. 1461-1468
-
-
Curiel, L.1
Souchon, R.2
Rouvière, O.3
Gelet, A.4
Chapelon, J.Y.5
-
23
-
-
77953569221
-
Integrated therapy delivery systems
-
Jolesz FA, Hynynen KH, eds London: Informa Healthcare
-
Hynynen KH, McDannold N. Integrated therapy delivery systems. In: Jolesz FA, Hynynen KH, eds. MRI-Guided Focused Ultrasound Surgery. London: Informa Healthcare, 2008.
-
(2008)
MRI-Guided Focused Ultrasound Surgery
-
-
Hynynen, K.H.1
McDannold, N.2
-
25
-
-
14944376721
-
Healing sound: The use of ultrasound in drug delivery and other therapeutic applications
-
Mitragorta S. Healing sound: the use of ultrasound in drug delivery and other therapeutic applications. Nat Rev Drug Discov 2005; 4: 255-60.
-
(2005)
Nat Rev Drug Discov
, vol.4
, pp. 255-260
-
-
Mitragorta, S.1
-
26
-
-
48149101439
-
Progress and problems in the application of focused ultrasound for blood-brain barrier disruption
-
Vykhodtseva N, McDannold N, Hynynen KH. Progress and problems in the application of focused ultrasound for blood-brain barrier disruption. Ultrasonics 2008; 48: 279-96.
-
(2008)
Ultrasonics
, vol.48
, pp. 279-296
-
-
Vykhodtseva, N.1
McDannold, N.2
Hynynen, K.H.3
-
27
-
-
67651089634
-
Lipid-shelled vehicles: Engineering for ultrasound molecular imaging and drug delivery
-
Ferrara KW, Borden MA, Zhang H. Lipid-shelled vehicles: engineering for ultrasound molecular imaging and drug delivery. Acc Chem Res 2009; 42: 881-92.
-
(2009)
Acc Chem Res
, vol.42
, pp. 881-892
-
-
Ferrara, K.W.1
Borden, M.A.2
Zhang, H.3
-
28
-
-
33847446049
-
Stimulated optical radiation in ruby
-
Maiman TH. Stimulated optical radiation in ruby. Nature 1960; 187: 493-94.
-
(1960)
Nature
, vol.187
, pp. 493-494
-
-
Maiman, T.H.1
-
29
-
-
33646128024
-
Laser eye surgery for refractive errors
-
Sakimoto T, Rosenblatt MI, Azar D T. Laser eye surgery for refractive errors. Lancet 2006; 367: 1432-47.
-
(2006)
Lancet
, vol.367
, pp. 1432-1447
-
-
Sakimoto, T.1
Rosenblatt, M.I.2
Azar, D.T.3
-
30
-
-
0141559198
-
Nanodissection of human chromosomes with near-infrared femtosecond laser pulses
-
Konig K, Riemann I, Fritzsche W. Nanodissection of human chromosomes with near-infrared femtosecond laser pulses. Opt Lett 2001; 26: 819-21.
-
(2001)
Opt Lett
, vol.26
, pp. 819-821
-
-
Konig, K.1
Riemann, I.2
Fritzsche, W.3
-
31
-
-
0036135270
-
Holmium laser lithotripsy for upper urinary tract calculi in 598 patients
-
Sofer M, Watterson JD, Wollin TA, et al. Holmium laser lithotripsy for upper urinary tract calculi in 598 patients. J Urology 2002; 167: 31-34.
-
(2002)
J Urology
, vol.167
, pp. 31-34
-
-
Sofer, M.1
Watterson, J.D.2
Wollin, T.A.3
-
32
-
-
0032998253
-
Holmium:YAG lithotripsy: Photothermal mechanism
-
Vassar GJ, Chan KF, Teichman JMH, et al. Holmium:YAG lithotripsy: photothermal mechanism. J Endourology 1999; 13: 181-90.
-
(1999)
J Endourology
, vol.13
, pp. 181-190
-
-
Vassar, G.J.1
Chan, K.F.2
Jmh, T.3
-
33
-
-
18744397861
-
Photosensitization of singlet oxygen via two-photon-excited fluorescence resonance energy transfer in a water-soluble dendrimer
-
Oar MA, Serin JA, Dichtel WR, Frechet JMJ. Photosensitization of singlet oxygen via two-photon-excited fluorescence resonance energy transfer in a water-soluble dendrimer. Chem Mater 2005; 17: 2267-75.
-
(2005)
Chem Mater
, vol.17
, pp. 2267-2275
-
-
Oar, M.A.1
Serin, J.A.2
Dichtel, W.R.3
Frechet, J.M.J.4
-
34
-
-
0141644208
-
High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution
-
Konig K, Riemann IJ. High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. J Biomed Opt 2003; 8: 423-29.
-
(2003)
J Biomed Opt
, vol.8
, pp. 423-429
-
-
Konig, K.1
Riemann, I.J.2
-
35
-
-
76849114854
-
Photoacoustics, thermoacoustics, and acousto-optics for biomedical imaging
-
Tang M-X, Elson DS, Li R, Dunsby C, Eckersley RJ. Photoacoustics, thermoacoustics, and acousto-optics for biomedical imaging. Proc Inst Mech Eng H 2010; 2: 291-306.
-
(2010)
Proc Inst Mech Eng H
, vol.2
, pp. 291-306
-
-
Tang, M.-X.1
Elson, D.S.2
Li, R.3
Dunsby, C.4
Eckersley, R.J.5
-
36
-
-
33746803555
-
Image formation by induced local interactions: Examples of employing nuclear magnetic resonance
-
Lauterbur PC. Image formation by induced local interactions: examples of employing nuclear magnetic resonance. Nature 1973; 242: 190-91.
-
(1973)
Nature
, vol.242
, pp. 190-191
-
-
Lauterbur, P.C.1
-
37
-
-
0022645636
-
Stereotaxic biopsy of the brain under MR imaging control
-
Thomas DG, Davis CH, Ingram S, Olney JS, Bydder GM, Young IR. Stereotaxic biopsy of the brain under MR imaging control. Am J Neuroradiol 1986; 7: 161-63.
-
(1986)
Am J Neuroradiol
, vol.7
, pp. 161-163
-
-
Thomas, D.G.1
Davis, C.H.2
Ingram, S.3
Olney, J.S.4
Bydder, G.M.5
Young, I.R.6
-
38
-
-
0035061283
-
MR imaging-guided stent placement in iliac arterial stenoses: A feasibility study
-
Manke C, Nitz WR, Djavidani B, et al. MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. Radiology 2001; 219: 527-34.
-
(2001)
Radiology
, vol.219
, pp. 527-534
-
-
Manke, C.1
Nitz, W.R.2
Djavidani, B.3
-
39
-
-
33744770950
-
Testing methods for MR safety and compatibility of medical devices
-
Schaefers G, Melzer A. Testing methods for MR safety and compatibility of medical devices. Minim Invasive Ther Allied Technol 2006; 15: 71-75.
-
(2006)
Minim Invasive Ther Allied Technol
, vol.15
, pp. 71-75
-
-
Schaefers, G.1
Melzer, A.2
-
40
-
-
0029781333
-
Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization
-
Burl M, Coutts GA, Young IR. Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization. Magn Reson Med 1996; 36: 491-93.
-
(1996)
Magn Reson Med
, vol.36
, pp. 491-493
-
-
Burl, M.1
Coutts, G.A.2
Young, I.R.3
-
41
-
-
33744773464
-
Improvement of the MR imaging behaviour of vascular implants
-
Immel E, Melzer A. Improvement of the MR imaging behaviour of vascular implants. Minim Invasive Ther Allied Technol 2006; 15: 85-92.
-
(2006)
Minim Invasive Ther Allied Technol
, vol.15
, pp. 85-92
-
-
Immel, E.1
Melzer, A.2
-
42
-
-
0030820138
-
Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications
-
Black PM, Moriarty T, Alexander E, et al. Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. Neurosurgery 1997; 41: 831-45.
-
(1997)
Neurosurgery
, vol.41
, pp. 831-845
-
-
Black, P.M.1
Moriarty, T.2
Alexander, E.3
-
43
-
-
0033808915
-
Intraoperative magnetic resonance image guidance in neurosurgery
-
Lewin JS, Metzger A, Selman WR. Intraoperative magnetic resonance image guidance in neurosurgery. J Magn Reson Imaging 2000; 12: 512-24.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 512-524
-
-
Lewin, J.S.1
Metzger, A.2
Selman, W.R.3
-
44
-
-
4644265713
-
Intraoperative high-field-strength MR imaging: Implementation and experience in 200 patients
-
Nimsky C, Ganslandt O, von Keller B, Romstöck J, Fahlbusch R. Intraoperative high-field-strength MR imaging: implementation and experience in 200 patients. Radiology 2004; 233: 67-78.
-
(2004)
Radiology
, vol.233
, pp. 67-78
-
-
Nimsky, C.1
Ganslandt, O.2
Von Keller, B.3
Romstöck, J.4
Fahlbusch, R.5
-
45
-
-
33646200054
-
Intraoperative magnetic resonance imaging-guided neurosurgery at 3-T
-
Truwit CL, Hall WA. Intraoperative magnetic resonance imaging-guided neurosurgery at 3-T. Neurosurgery 2006; 58: 338-45.
-
(2006)
Neurosurgery
, vol.58
, pp. 338-345
-
-
Truwit, C.L.1
Hall, W.A.2
-
46
-
-
0020583556
-
Influence of the interval between primary tumor removal and chemotherapy on kinetics and growth of metastases
-
Fisher B, Gunduz N, Saff er EA. Influence of the interval between primary tumor removal and chemotherapy on kinetics and growth of metastases. Cancer Res 1983; 43: 1488-92.
-
(1983)
Cancer Res
, vol.43
, pp. 1488-1492
-
-
Fisher, B.1
Gunduz, N.2
Saffer, E.A.3
-
47
-
-
84859914916
-
MR-guided transapical delivery of a self expanding heart valve prosthesis equipped with a resonant circuit: Initial experiences in porcine model
-
Melzer A, Horvath K, Guttman M, et al. MR-guided transapical delivery of a self expanding heart valve prosthesis equipped with a resonant circuit: initial experiences in porcine model. ISMRM Proc 2006; 270: 61.
-
(2006)
ISMRM Proc
, vol.270
, pp. 61
-
-
Melzer, A.1
Horvath, K.2
Guttman, M.3
-
48
-
-
77249095026
-
Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model
-
Hoffmann BA, Koops A, Rostock T, et al. Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model. Eur Heart J 2010, 31: 450-56.
-
(2010)
Eur Heart J
, vol.31
, pp. 450-456
-
-
Hoffmann, B.A.1
Koops, A.2
Rostock, T.3
-
49
-
-
33744726142
-
Interventional robotic systems: Applications and technology state of the art
-
Cleary K, Melzer A, Watson V, Kronreif G, Stoianovici D. Interventional robotic systems: applications and technology state of the art. Minim Invasive Ther Allied Technol 2006; 15: 101-13.
-
(2006)
Minim Invasive Ther Allied Technol
, vol.15
, pp. 101-113
-
-
Cleary, K.1
Melzer, A.2
Watson, V.3
Kronreif, G.4
Stoianovici, D.5
-
50
-
-
79956294511
-
MR-compatible robotic system for biopsies in a high field MRI system: Initial results in patients with suspicious prostate lesions
-
Zangos J, Sadighi C, Thalhammer A, et al. MR-compatible robotic system for biopsies in a high field MRI system: initial results in patients with suspicious prostate lesions. Radiology 2011; 259: 903-10.
-
(2011)
Radiology
, vol.259
, pp. 903-910
-
-
Zangos, J.1
Sadighi, C.2
Thalhammer, A.3
-
53
-
-
0002646875
-
Magnetic resonance image-guided focused ultrasound surgery
-
Jolesz FA, Hynynen KH. Magnetic resonance image-guided focused ultrasound surgery. Cancer J 2002; 8: 100-12.
-
(2002)
Cancer J
, vol.8
, pp. 100-112
-
-
Jolesz, F.A.1
Hynynen, K.H.2
-
54
-
-
33745221857
-
Magnetic resonance-guided focused ultrasound surgery of breast cancer: Reliability and effectiveness
-
Furusawa H, Namba K, Thomasen S, et al. Magnetic resonance-guided focused ultrasound surgery of breast cancer: reliability and effectiveness. J Am Coll Surg 2006; 203: 54-63.
-
(2006)
J Am Coll Surg
, vol.203
, pp. 54-63
-
-
Furusawa, H.1
Namba, K.2
Thomasen, S.3
-
55
-
-
66149111754
-
Early clinical experience using high intensity focused ultrasound for palliation of inoperable pancreatic cancer
-
Xiong LL, Hwang JH, Huang XB et al. Early clinical experience using high intensity focused ultrasound for palliation of inoperable pancreatic cancer. JOP 2009; 10: 123-29.
-
(2009)
JOP
, vol.10
, pp. 123-129
-
-
Xiong, L.L.1
Hwang, J.H.2
Huang, X.B.3
-
56
-
-
37549000196
-
High-intensity focused ultrasound: Current potential and oncologic applications
-
Dubinsky TJ, Cuevas C, Dighe MK, Kolokythas O, Hwang JH. High-intensity focused ultrasound: current potential and oncologic applications. Am J Roentgenol 2008; 190: 191-99.
-
(2008)
Am J Roentgenol
, vol.190
, pp. 191-199
-
-
Dubinsky, T.J.1
Cuevas, C.2
Dighe, M.K.3
Kolokythas, O.4
Hwang, J.H.5
-
57
-
-
53749095088
-
Palliative treatment of painful bone metastases with MR imaging-guided focused ultrasound
-
Gianfelice D, Gupta CH, Kucharczyk W, et al. Palliative treatment of painful bone metastases with MR imaging-guided focused ultrasound. Radiology 2008; 249: 352-62.
-
(2008)
Radiology
, vol.249
, pp. 352-362
-
-
Gianfelice, D.1
Gupta, C.H.2
Kucharczyk, W.3
|