Human distal sciatic nerve fascicular anatomy: Implications for ankle control using nerve-cuff electrodes

Author keywords

Anatomy; Ankle; Common fibular; Cuff; Electrode; Nerve; Prosthesis; Rehabilitation; Sciatic; Tibial

Indexed keywords

ANATOMY; ANKLE; COMMON FIBULAR; CUFF; NERVE; SCIATIC; TIBIAL;

EID: 84859881294     PISSN: 07487711     EISSN: 19381352     Source Type: Journal    
DOI: 10.1682/JRRD.2010.10.0201     Document Type: Article
Times cited : (48)

References (30)
  • 1
    • 0016829641 scopus 로고
    • Experimental correction of footdrop by electrical stimulation of the peroneal nerve
    • PMID:1081538
    • Waters RL, McNeal D, Perry J. Experimental correction of footdrop by electrical stimulation of the peroneal nerve. J Bone Joint Surg Am. 1975;57(8):1047-54. PMID:1081538
    • (1975) J Bone Joint Surg Am , vol.57 , Issue.8 , pp. 1047-1054
    • Waters, R.L.1    McNeal, D.2    Perry, J.3
  • 2
    • 0023135406 scopus 로고
    • Treatment of drop foot using an implantable peroneal underknee stimulator
    • PMID:3495033
    • Strojnik P, Acimovic R, Vavken E, Simic V, Stanic U. Treatment of drop foot using an implantable peroneal underknee stimulator. Scand J Rehabil Med. 1987;19(1): 37-43. PMID:3495033
    • (1987) Scand J Rehabil Med , vol.19 , Issue.1 , pp. 37-43
    • Strojnik, P.1    Acimovic, R.2    Vavken, E.3    Simic, V.4    Stanic, U.5
  • 3
    • 0026664807 scopus 로고
    • Gait evaluation in hemiparetic patients using subcutaneous peroneal electrical stimulation
    • PMID:1411357
    • Kljaji M, Malezic M, Aimovi R, Vavken E, Stanic U, Pan-grsic B, Rozman J. Gait evaluation in hemiparetic patients using subcutaneous peroneal electrical stimulation. Scand J Rehabil Med. 1992;24(3):121-26. PMID:1411357
    • (1992) Scand J Rehabil Med , vol.24 , Issue.3 , pp. 121-126
    • Kljaji, M.1    Malezic, M.2    Aimovi, R.3    Vavken, E.4    Stanic, U.5    Pan-Grsic, B.6    Rozman, J.7
  • 4
    • 0036159631 scopus 로고    scopus 로고
    • Real time foot drop correction using machine learning and natural sensors
    • PMID:22151781& http://dx.doi.org/10.1046/j.1525-1403.2002._2008.x
    • Hansen M, Haugland M, Sinkjaer T, Donaldson N. Real time foot drop correction using machine learning and natural sensors. Neuromodulation. 2002;5(1):41-53. PMID:22151781& http://dx.doi.org/10.1046/j.1525-1403.2002._2008.x
    • (2002) Neuromodulation , vol.5 , Issue.1 , pp. 41-53
    • Hansen, M.1    Haugland, M.2    Sinkjaer, T.3    Donaldson, N.4
  • 6
    • 0029510632 scopus 로고
    • Cutaneous whole nerve record-ings used for correction of footdrop in hemiplegic man
    • http://dx.doi.org/10.1109/86.481970
    • Haugland MK, Sinkjaer T. Cutaneous whole nerve record-ings used for correction of footdrop in hemiplegic man. IEEE Trans Rehabil Eng. 1995;3(4):307-17. http://dx.doi.org/10.1109/86.481970
    • (1995) IEEE Trans Rehabil Eng , vol.3 , Issue.4 , pp. 307-317
    • Haugland, M.K.1    Sinkjaer, T.2
  • 8
    • 0036991511 scopus 로고    scopus 로고
    • A review of portable FES-based neural orthoses for the correction of drop foot
    • PMID:12611364 & http://dx.doi.org/10.1109/TNSRE.2002.806832
    • Lyons GM, Sinkjaer T, Burridge JH, Wilcox DJ. A review of portable FES-based neural orthoses for the correction of drop foot. IEEE Trans Neural Syst Rehabil Eng. 2002; 10(4):260-79. PMID:12611364 & http://dx.doi.org/10.1109/TNSRE.2002.806832
    • (2002) IEEE Trans Neural Syst Rehabil Eng , vol.10 , Issue.4 , pp. 260-279
    • Lyons, G.M.1    Sinkjaer, T.2    Burridge, J.H.3    Wilcox, D.J.4
  • 9
    • 0345099656 scopus 로고    scopus 로고
    • Modi-fied implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width pro-files
    • PMID:14686596 & http://dx.doi.org/10.1007/BF02349978
    • O'Halloran T, Haugland M, Lyons GM, Sinkjaer T. Modi-fied implanted drop foot stimulator system with graphical user interface for customised stimulation pulse-width pro-files. Med Biol Eng Comput. 2003;41(6):701-9. PMID:14686596 & http://dx.doi.org/10.1007/BF02349978
    • (2003) Med Biol Eng Comput , vol.41 , Issue.6 , pp. 701-709
    • O'Halloran, T.1    Haugland, M.2    Lyons, G.M.3    Sinkjaer, T.4
  • 10
    • 0037213330 scopus 로고    scopus 로고
    • Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implant-able drop-foot stimulator
    • PMID:12485783 & http://dx.doi.org/10.1016/S1350-4533(02)00041-3
    • Veltink PH, Slycke P, Hemssems J, Buschman R, Bultstra G, Hermens H. Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implant-able drop-foot stimulator. Med Eng Phys. 2003;25(1):21-28. PMID:12485783 & http://dx.doi.org/10.1016/S1350-4533(02)00041-3
    • (2003) Med Eng Phys , vol.25 , Issue.1 , pp. 21-28
    • Veltink, P.H.1    Slycke, P.2    Hemssems, J.3    Buschman, R.4    Bultstra, G.5    Hermens, H.6
  • 14
    • 0002294920 scopus 로고
    • Overview of peripheral nerve electrode design and implantation
    • editors. Neural prostheses: Fundamental studies. Englewood Cliffs (NJ): Prentice Hall
    • Naples GG, Mortimer JT, Yuen TG. Overview of peripheral nerve electrode design and implantation. In: Agnew WF, McCreery DB, editors. Neural prostheses: Fundamental studies. Englewood Cliffs (NJ): Prentice Hall; 1990. p. 107-45.
    • (1990) Agnew WF, McCreery DB , pp. 107-145
    • Naples, G.G.1    Mortimer, J.T.2    Yuen, T.G.3
  • 15
    • 0034004232 scopus 로고    scopus 로고
    • Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes
    • PMID:10679687 & http://dx.doi.org/10.1002/(SICI)1097- 4636(200005)50:2<215::AID-JBM17>3.0.CO;2-A
    • Grill WM, Mortimer JT. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J Biomed Mater Res. 2000;50(2): 215-26. PMID:10679687 & http://dx.doi.org/10.1002/(SICI)1097- 4636(200005)50:2<215::AID-JBM17>3.0.CO;2-A
    • (2000) J Biomed Mater Res , vol.50 , Issue.2 , pp. 215-226
    • Grill, W.M.1    Mortimer, J.T.2
  • 16
    • 42049099508 scopus 로고    scopus 로고
    • A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis
    • PMID:18403289 &http://dx.doi.org/10.1109/TNSRE.2008.918425
    • Schiefer MA, Triolo RJ, Tyler DJ. A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis. IEEE Trans Neural Syst Rehabil Eng. 2008;16(2):195-204. PMID:18403289 &http://dx.doi.org/10.1109/TNSRE.2008.918425
    • (2008) IEEE Trans Neural Syst Rehabil Eng , vol.16 , Issue.2 , pp. 195-204
    • Schiefer, M.A.1    Triolo, R.J.2    Tyler, D.J.3
  • 17
    • 0242375641 scopus 로고
    • The intraneural plexus of fasciculi and fibers in the sciatic nerve
    • McKinley JC. The intraneural plexus of fasciculi and fibers in the sciatic nerve. Arch Neurol Psychiatry. 1921;6(4): 377-99.
    • (1921) Arch Neurol Psychiatry , vol.6 , Issue.4 , pp. 377-399
    • McKinley, J.C.1
  • 18
    • 0001142522 scopus 로고
    • The intraneural topography of the sciatic nerve and its popliteal divisions in man
    • PMID:18099549 & http://dx.doi.org/10.1093/brain/71.3.242
    • Sunderland S, Ray LJ. The intraneural topography of the sciatic nerve and its popliteal divisions in man. Brain. 1948;71(Pt 3):242-73. PMID:18099549 & http://dx.doi.org/10.1093/brain/71.3.242
    • (1948) Brain , vol.71 , Issue.Pt 3 , pp. 242-273
    • Sunderland, S.1    Ray, L.J.2
  • 19
    • 0035087305 scopus 로고    scopus 로고
    • Selectivity of multiple-contact nerve cuff electrodes: A simulation analysis
    • PMID:11296872 &http://dx.doi.org/10.1109/10.909637
    • Choi AQ, Cavanaugh JK, Durand DM. Selectivity of multiple-contact nerve cuff electrodes: A simulation analysis. IEEE Trans Biomed Eng. 2001;48(2):165-72. PMID:11296872 &http://dx.doi.org/10.1109/10.909637
    • (2001) IEEE Trans Biomed Eng , vol.48 , Issue.2 , pp. 165-172
    • Choi, A.Q.1    Cavanaugh, J.K.2    Durand, D.M.3
  • 20
    • 0030176010 scopus 로고    scopus 로고
    • Quantification of recruitment properties of multiple contact cuff electrodes
    • PMID:8798072& http://dx.doi.org/10.1109/86.506402
    • Grill WM, Jr, Mortimer JT. Quantification of recruitment properties of multiple contact cuff electrodes. IEEE Trans Rehabil Eng. 1996;4(2):49-62. PMID:8798072& http://dx.doi.org/10.1109/86.506402
    • (1996) IEEE Trans Rehabil Eng , vol.4 , Issue.2 , pp. 49-62
    • Grill Jr., W.M.1    Mortimer, J.T.2
  • 21
    • 0036994474 scopus 로고    scopus 로고
    • Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
    • PMID:12611367& http://dx.doi.org/10.1109/TNSRE.2002.806840
    • Tyler DJ, Durand DM. Functionally selective peripheral nerve stimulation with a flat interface nerve electrode. IEEE Trans Neural Syst Rehabil Eng. 2002;10(4):294-303. PMID:12611367& http://dx.doi.org/10.1109/TNSRE.2002.806840
    • (2002) IEEE Trans Neural Syst Rehabil Eng , vol.10 , Issue.4 , pp. 294-303
    • Tyler, D.J.1    Durand, D.M.2
  • 22
    • 74049157989 scopus 로고    scopus 로고
    • Fascicular anatomy of human femoral nerve: Implications for neural prostheses using nerve cuff electrodes
    • PMID:20104420 &http://dx.doi.org/10.1682/JRRD.2008.08.0097
    • Gustafson KJ, Pinault GC, Neville JJ, Syed IS, Davis JA, Jr, Jean-Claude J, Triolo RJ. Fascicular anatomy of human femoral nerve: Implications for neural prostheses using nerve cuff electrodes. J Rehabil Res Dev. 2009;46(7):973-84. PMID:20104420 &http://dx.doi.org/10.1682/JRRD.2008.08.0097
    • (2009) J Rehabil Res Dev , vol.46 , Issue.7 , pp. 973-984
    • Gustafson, K.J.1    Pinault, G.C.2    Neville, J.J.3    Syed, I.S.4    Davis Jr., J.A.5    Jean-Claude, J.6    Triolo, R.J.7
  • 23
    • 77950998308 scopus 로고    scopus 로고
    • Intraoperative demonstration of selective stimulation of the common human femoral nerve with a FINE
    • Sep 3-6, Minneapolis, MN
    • Schiefer MA, Polasek KH, Triolo RJ, Pinault GC, Tyler DJ. Intraoperative demonstration of selective stimulation of the common human femoral nerve with a FINE. Proc 31st Ann Int Conf IEEE EBMS; 2009 Sep 3-6; Minneapolis, MN. p. 610-13.
    • (2009) Proc 31st Ann Int Conf IEEE EBMS , pp. 610-613
    • Schiefer, M.A.1    Polasek, K.H.2    Triolo, R.J.3    Pinault, G.C.4    Tyler, D.J.5
  • 24
    • 77949890676 scopus 로고    scopus 로고
    • Selective stimulation of the human femoral nerve with a flat interface nerve electrode
    • 26006. PMID:20208125 http://dx.doi.org/10.1088/1741-2560/7/2/026006
    • Schiefer MA, Polasek KH, Triolo RJ, Pinault GC, Tyler DJ. Selective stimulation of the human femoral nerve with a flat interface nerve electrode. J Neural Eng. 2010;7(2): 26006. PMID:20208125 http://dx.doi.org/10.1088/1741-2560/7/2/026006
    • (2010) J Neural Eng , vol.7 , Issue.2
    • Schiefer, M.A.1    Polasek, K.H.2    Triolo, R.J.3    Pinault, G.C.4    Tyler, D.J.5
  • 25
    • 0004276918 scopus 로고    scopus 로고
    • 5th ed. Baltimore (MD): Lippincott Williams & Wilkins
    • Moore KL, Dalley AF. Clinically Oriented Anatomy. 5th ed. Baltimore (MD): Lippincott Williams & Wilkins; 2006. p. 555-724.
    • (2006) Clinically Oriented Anatomy , pp. 555-724
    • Moore, K.L.1    Dalley, A.F.2
  • 26
    • 0036862294 scopus 로고    scopus 로고
    • Sciatic nerve variations in some studies on the Polish population and its statistical significance
    • PMID:12725497
    • Okraszewska E, Migdalski L, Jedrzejewski KS, Bol-anowski W. Sciatic nerve variations in some studies on the Polish population and its statistical significance. Folia Morphol (Warsz). 2002;61(4):277-82. PMID:12725497
    • (2002) Folia Morphol (Warsz) , vol.61 , Issue.4 , pp. 277-282
    • Okraszewska, E.1    Migdalski, L.2    Jedrzejewski, K.S.3    Bol-Anowski, W.4
  • 27
    • 1842628632 scopus 로고    scopus 로고
    • Restoration of motor function of the deep fibular (peroneal) nerve by direct nerve transfer of branches from the tibial nerve: An ana-tomical study
    • PMID:15042567 http://dx.doi.org/10.1002/ca.10189
    • Bodily KD, Spinner RJ, Bishop AT. Restoration of motor function of the deep fibular (peroneal) nerve by direct nerve transfer of branches from the tibial nerve: An ana-tomical study. Clin Anat. 2004;17(3):201-5. PMID:15042567 http://dx.doi.org/10.1002/ca.10189
    • (2004) Clin Anat , vol.17 , Issue.3 , pp. 201-205
    • Bodily, K.D.1    Spinner, R.J.2    Bishop, A.T.3
  • 28
    • 0018921333 scopus 로고
    • Internal topography of major nerves of the forearm and hand: A current view
    • PMID:7365209
    • Jabaley ME, Wallace WH, Heckler FR. Internal topography of major nerves of the forearm and hand: A current view. J Hand Surg Am. 1980;5(1):1-18. PMID:7365209
    • (1980) J Hand Surg Am , vol.5 , Issue.1 , pp. 1-18
    • Jabaley, M.E.1    Wallace, W.H.2    Heckler, F.R.3
  • 29
    • 31144436039 scopus 로고    scopus 로고
    • Fascicular anatomy and surgical access of the human pudendal nerve
    • PMID:16333625 & http://dx.doi.org/10.1007/s00345-005-0032-4
    • Gustafson KJ, Zelkovic PF, Feng AH, Draper CE, Bodner DR, Grill WM. Fascicular anatomy and surgical access of the human pudendal nerve. World J Urol. 2005;23(6):411-18. PMID:16333625 & http://dx.doi.org/10.1007/s00345-005-0032-4
    • (2005) World J Urol , vol.23 , Issue.6 , pp. 411-418
    • Gustafson, K.J.1    Zelkovic, P.F.2    Feng, A.H.3    Draper, C.E.4    Bodner, D.R.5    Grill, W.M.6
  • 30
    • 0021800935 scopus 로고
    • Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up
    • PMID:3873456
    • Waters RL, McNeal DR, Faloon W, Clifford B. Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up. J Bone Joint Surg Am. 1985;67(5):792-93. PMID:3873456
    • (1985) J Bone Joint Surg Am , vol.67 , Issue.5 , pp. 792-793
    • Waters, R.L.1    McNeal, D.R.2    Faloon, W.3    Clifford, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.