Volumn 35, Issue 5, 2012, Pages 1071-1076

Cardiac MRI of the fetal heart using a novel triggering method: Initial results in an animal model

Author keywords

Diagnosis; Fetal MRI; Imaging; Magnetic resonance imaging; Pregnancy

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; CARDIOTOCOGRAPHY; CARDIOVASCULAR MAGNETIC RESONANCE; EWE; FETUS; FETUS HEART; HEART CONTRACTION; HEART FORAMEN OVALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE VOLUME; HEART STROKE VOLUME; HEART VALVE; IMAGE QUALITY; NONHUMAN; PRIORITY JOURNAL; STEADY STATE;

EID: 84859798068     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23541     Document Type: Article
Times cited : (38)

References (21)
  • 1
    • 0038105073 scopus 로고    scopus 로고
    • Volumetric assessment of normal fetal lungs using three-dimensional ultrasound
    • DOI 10.1016/S0301-5629(03)00902-5
    • Chang CH, Yu CH, Chang FM, Ko HC, Chen HY. Volumetric assessment of normal fetal lungs using three-dimensional ultrasound. Ultrasound Med Biol 2003;29:935-942. (Pubitemid 36871723)
    • (2003) Ultrasound in Medicine and Biology , vol.29 , Issue.7 , pp. 935-942
    • Chang, C.-H.1    Yu, C.-H.2    Chang, F.-M.3    Ko, H.-C.4    Chen, H.-Y.5
  • 3
    • 0036905438 scopus 로고    scopus 로고
    • Interventional fetal cardiac therapy - Possible perspectives and current shortcomings
    • DOI 10.1046/j.1469-0705.2002.00858.x
    • Meyer-Wittkopf M. Interventional fetal cardiac therapy - possible perspectives and current shortcomings. Ultrasound Obstet Gynecol 2002;20:527-531. (Pubitemid 36002608)
    • (2002) Ultrasound in Obstetrics and Gynecology , vol.20 , Issue.6 , pp. 527-531
    • Meyer-Wittkopf, M.1
  • 4
    • 0030278068 scopus 로고    scopus 로고
    • Evaluation of three-dimensional ultrasonography and magnetic resonance imaging in assessment of congenital heart anomalies in fetal cardiac specimens
    • Meyer-Wittkopf M, Cook A, McLennan A, Summers P, Sharland GK, Maxwell DJ. Evaluation of three-dimensional ultrasonography and magnetic resonance imaging in assessment of congenital heart anomalies in fetal cardiac specimens. Ultrasound Obstet Gynecol 1996;8:303-308. (Pubitemid 126720613)
    • (1996) Ultrasound in Obstetrics and Gynecology , vol.8 , Issue.5 , pp. 303-308
    • Meyer-Wittkopf, M.1    Cook, A.2    McLennan, A.3    Summers, P.4    Sharland, G.K.5    Maxwell, D.J.6
  • 5
    • 11144230801 scopus 로고    scopus 로고
    • New fetal cardiac imaging techniques
    • DOI 10.1002/pd.1066
    • Deng J, Rodeck CH. New fetal cardiac imaging techniques. Prenat Diagn 2004;24:1092-1103. (Pubitemid 40053032)
    • (2004) Prenatal Diagnosis , vol.24 , Issue.13 , pp. 1092-1103
    • Deng, J.1    Rodeck, C.H.2
  • 6
    • 33646536100 scopus 로고    scopus 로고
    • Current applications of fetal cardiac imaging technology
    • Deng J, Rodeck CH. Current applications of fetal cardiac imaging technology. Curr Opin Obstet Gynecol 2006;18:177-184.
    • (2006) Curr Opin Obstet Gynecol , vol.18 , pp. 177-184
    • Deng, J.1    Rodeck, C.H.2
  • 7
    • 78651568741 scopus 로고    scopus 로고
    • A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes
    • Yu H, Pattichis MS, Agurto C, Beth Goens M. A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes. Biomed Eng Online 2011;10:7.
    • (2011) Biomed Eng Online , vol.10 , pp. 7
    • Yu, H.1    Pattichis, M.S.2    Agurto, C.3    Beth Goens, M.4
  • 8
    • 70349865119 scopus 로고    scopus 로고
    • High resolution MR imaging of the fetal heart with cardiac triggering: A feasibility study in the sheep fetus
    • Yamamura J, Kooijmann H, Frisch M, Hecher K, Adam G, Wedegartner U. High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus. Eur Radiol 2009;19:2383-2390.
    • (2009) Eur Radiol , vol.19 , pp. 2383-2390
    • Yamamura, J.1    Kooijmann, H.2    Frisch, M.3    Hecher, K.4    Adam, G.5    Wedegartner, U.6
  • 9
    • 70049107132 scopus 로고    scopus 로고
    • In ovo non-invasive quantification of the myocardial function and mass of chick embryos using magnetic resonance imaging
    • Holmes WM, Mullin JM, Condon B, Bain MM. In ovo non-invasive quantification of the myocardial function and mass of chick embryos using magnetic resonance imaging. NMR Biomed 2009; 22:745-752.
    • (2009) NMR Biomed , vol.22 , pp. 745-752
    • Holmes, W.M.1    Mullin, J.M.2    Condon, B.3    Bain, M.M.4
  • 10
    • 66149105947 scopus 로고    scopus 로고
    • Three-dimensional, in vivo MRI with self-gating and image coregistration in the mouse
    • Nieman BJ, Turnbull DH. Three-dimensional, in vivo MRI with self-gating and image coregistration in the mouse. Magn Reson Med 2009;6:1148-1157.
    • (2009) Magn Reson Med , vol.6 , pp. 1148-1157
    • Nieman, B.J.1    Turnbull, D.H.2
  • 11
    • 78650546576 scopus 로고    scopus 로고
    • Self-gating MR imaging of the fetal heart: Comparison with real cardiac triggering
    • Yamamura J, Frisch M, Ecker H, et al. Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering. Eur Radiol 2011;21:142-149.
    • (2011) Eur Radiol , vol.21 , pp. 142-149
    • Yamamura, J.1    Frisch, M.2    Ecker, H.3
  • 12
    • 70350709890 scopus 로고    scopus 로고
    • Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope
    • Frauenrath T, Hezel F, Heinrichs U, et al. Feasibility of cardiac gating free of interference with electro-magnetic fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla using an MR-stethoscope. Invest Radiol 2009;44:539-547.
    • (2009) Invest Radiol , vol.44 , pp. 539-547
    • Frauenrath, T.1    Hezel, F.2    Heinrichs, U.3
  • 13
    • 77952096359 scopus 로고    scopus 로고
    • Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T
    • Becker M, Frauenrath T, Hezel F, et al. Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T. Eur Radiol 2010;20:1344-1355.
    • (2010) Eur Radiol , vol.20 , pp. 1344-1355
    • Becker, M.1    Frauenrath, T.2    Hezel, F.3
  • 14
    • 0031758191 scopus 로고    scopus 로고
    • MRI does not change fetal cardiotocographic parameters
    • DOI 10.1002/(SICI)1097-0223(199811)18:11<1149::AID-PD421>3.0.CO;2-K
    • Poutamo J, Partanen K, Vanninen R, Vainio P, Kirkinen P. MRI does not change fetal cardiotocographic parameters. Prenat Diagn 1998;18:1149-1154. (Pubitemid 28526224)
    • (1998) Prenatal Diagnosis , vol.18 , Issue.11 , pp. 1149-1154
    • Poutamo, J.1    Partanen, K.2    Vanninen, R.3    Vainio, P.4    Kirkinen, P.5
  • 15
    • 0032717795 scopus 로고    scopus 로고
    • A method for foetal heart rate monitoring during magnetic resonance imaging using Doppler ultrasound
    • Shakespeare SA, Moore RJ, Crowe JA, Gowland PA, Hayes-Gill BR. A method for foetal heart rate monitoring during magnetic resonance imaging using Doppler ultrasound. Physiol Meas 1999;20:363-368.
    • (1999) Physiol Meas , vol.20 , pp. 363-368
    • Shakespeare, S.A.1    Moore, R.J.2    Crowe, J.A.3    Gowland, P.A.4    Hayes-Gill, B.R.5
  • 17
    • 53249131059 scopus 로고    scopus 로고
    • Feasibility of MRI of the fetal heart with balanced steady-state free precession sequence along fetal body and cardiac planes
    • Saleem SN. Feasibility of MRI of the fetal heart with balanced steady-state free precession sequence along fetal body and cardiac planes. AJR Am J Roentgenol 2008;191:1208-1215.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1208-1215
    • Saleem, S.N.1
  • 20
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO;2-9
    • Fischer SE, Wickline SA, Lorenz CH. Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999;42:361-370. (Pubitemid 29364715)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.2 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 21
    • 0033761052 scopus 로고    scopus 로고
    • Performance of QRS detection for cardiacmagnetic resonance imagingwith a novel vectorcardiographic triggering method
    • Chia JM, Fischer SE, Wickline SA, Lorenz CH. Performance of QRS detection for cardiacmagnetic resonance imagingwith a novel vectorcardiographic triggering method. JMagn Reson Imaging 2000;12:678-688.
    • (2000) JMagn Reson Imaging , vol.12 , pp. 678-688
    • Chia, J.M.1    Fischer, S.E.2    Wickline, S.A.3    Lorenz, C.H.4