메뉴 건너뛰기




Volumn 35, Issue 5, 2012, Pages 1233-1239

Improving quality of arterial spin labeling MR imaging at 3 Tesla with a 32-channel coil and parallel imaging

Author keywords

Array coil; Arterial spin labeling; Brain; Magnetic resonance imaging; Parallel imaging; Perfusion imaging

Indexed keywords

ADULT; ARTICLE; ARTIFACT; DEVICES; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE QUALITY; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SIGNAL NOISE RATIO; SPIN LABELING;

EID: 84859795017     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23586     Document Type: Article
Times cited : (20)

References (20)
  • 2
    • 60549084357 scopus 로고    scopus 로고
    • Arterial spin labeling perfusion MRI in pediatric arterial ischemic stroke: Initial experiences
    • Chen J, Licht DJ, Smith SE, et al. Arterial spin labeling perfusion MRI in pediatric arterial ischemic stroke: initial experiences. J Magn Reson Imaging 2009;29:282-290.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 282-290
    • Chen, J.1    Licht, D.J.2    Smith, S.E.3
  • 3
    • 77952645949 scopus 로고    scopus 로고
    • Chronic and treatment-resistant depression: A study using arterial spin labeling perfusion MRI at 3Tesla
    • Duhameau B, Ferre JC, Jannin P, et al. Chronic and treatment-resistant depression: A study using arterial spin labeling perfusion MRI at 3Tesla. Psychiatry Res 2010;182:111-116.
    • (2010) Psychiatry Res , vol.182 , pp. 111-116
    • Duhameau, B.1    Ferre, J.C.2    Jannin, P.3
  • 4
    • 79953248554 scopus 로고    scopus 로고
    • Posterior hypoperfusion in Parkinson's disease with and without dementia measured with arterial spin labeling MRI
    • Kamagata K, Motoi Y, Hori M, et al. Posterior hypoperfusion in Parkinson's disease with and without dementia measured with arterial spin labeling MRI. J Magn Reson Imaging 2011;33:803-807.
    • (2011) J Magn Reson Imaging , vol.33 , pp. 803-807
    • Kamagata, K.1    Motoi, Y.2    Hori, M.3
  • 5
    • 41949140351 scopus 로고    scopus 로고
    • SNR and functional sensitivity of BOLD and perfusion-based fMRI using arterial spin labeling with spiral SENSE at 3 T
    • Perthen JE, Bydder M, Restom K, Liu TT. SNR and functional sensitivity of BOLD and perfusion-based fMRI using arterial spin labeling with spiral SENSE at 3 T. Magn Reson Imaging 2008;26:513-522.
    • (2008) Magn Reson Imaging , vol.26 , pp. 513-522
    • Perthen, J.E.1    Bydder, M.2    Restom, K.3    Liu, T.T.4
  • 6
    • 79960619645 scopus 로고    scopus 로고
    • Arterial spin labeling for motor activation mapping at 3T with a 32-channel coil: Reproducibility and spatial accuracy in comparison with BOLD fMRI
    • Raoult H, Petr J, Bannier E, et al. Arterial spin labeling for motor activation mapping at 3T with a 32-channel coil: Reproducibility and spatial accuracy in comparison with BOLD fMRI. Neuroimage 2011;58:157-167.
    • (2011) Neuroimage , vol.58 , pp. 157-167
    • Raoult, H.1    Petr, J.2    Bannier, E.3
  • 7
    • 0042844535 scopus 로고    scopus 로고
    • Quantification of blood flow in brain tumors: Comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging
    • DOI 10.1148/radiol.2282020409
    • Warmuth C, Gunther M, Zimmer C. Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging. Radiology 2003;228:523-532. (Pubitemid 36910097)
    • (2003) Radiology , vol.228 , Issue.2 , pp. 523-532
    • Warmuth, C.1    Gunther, M.2    Zimmer, C.3
  • 9
    • 24144462588 scopus 로고    scopus 로고
    • Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T
    • DOI 10.1002/mrm.20574
    • Wang Z, Wang J, Connick TJ, Wetmore GS, Detre JA. Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T. Magn Reson Med 2005;54:732-737. (Pubitemid 41233771)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.3 , pp. 732-737
    • Wang, Z.1    Wang, J.2    Connick, T.J.3    Wetmore, G.S.4    Detre, J.A.5
  • 10
    • 33748273322 scopus 로고    scopus 로고
    • Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction
    • DOI 10.1002/jmri.20673
    • Lupo JM, Lee MC, Han ET, et al. Feasibility of dynamic susceptibility contrast perfusion MR imaging at 3T using a standard quadrature head coil and eight-channel phased-array coil with and without SENSE reconstruction. J Magn Reson Imaging 2006;24:520-529. (Pubitemid 44320552)
    • (2006) Journal of Magnetic Resonance Imaging , vol.24 , Issue.3 , pp. 520-529
    • Lupo, J.M.1    Lee, M.C.2    Han, E.T.3    Cha, S.4    Chang, S.M.5    Berger, M.S.6    Nelson, S.J.7
  • 11
    • 0346373773 scopus 로고    scopus 로고
    • Signal-to-Noise Ratio and Parallel Imaging Performance of a 16-Channel Receive-only Brain Coil Array at 3.0 Tesla
    • DOI 10.1002/mrm.10678
    • de Zwart JA, Ledden PJ, van Gelderen P, Bodurka J, Chu R, Duyn JH. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla. Magn Reson Med 2004;51:22-26. (Pubitemid 38095698)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 22-26
    • De Zwart, J.A.1    Ledden, P.J.2    Van Gelderen, P.3    Bodurka, J.4    Chu, R.5    Duyn, J.H.6
  • 12
    • 0032997648 scopus 로고    scopus 로고
    • 1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • DOI 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO;2-N
    • Luh WM, Wong EC, Bandettini PA, Hyde JS. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med 1999;41:1246-1254. (Pubitemid 29247294)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.6 , pp. 1246-1254
    • Luh, W.-M.1    Wong, E.C.2    Bandettini, P.A.3    Hyde, J.S.4
  • 13
    • 0030725989 scopus 로고    scopus 로고
    • Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    • Wong EC, Buxton RB, Frank LR. Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling. NMR Biomed 1997;10:237-249. (Pubitemid 27519924)
    • (1997) NMR in Biomedicine , vol.10 , Issue.4-5 , pp. 237-249
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 14
    • 40449110012 scopus 로고    scopus 로고
    • Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T
    • DOI 10.1002/jmri.21191
    • Preibisch C, Wallenhorst T, Heidemann R, Zanella FE, Lanfermann H. Comparison of parallel acquisition techniques generalized autocalibrating partially parallel acquisitions (GRAPPA) and modified sensitivity encoding (mSENSE) in functional MRI (fMRI) at 3T. J Magn Reson Imaging 2008;27:590-598. (Pubitemid 351354745)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.3 , pp. 590-598
    • Preibisch, C.1    Wallenhorst, T.2    Heidemann, R.3    Zanella, F.E.4    Lanfermann, H.5
  • 15
    • 79751474582 scopus 로고    scopus 로고
    • Denoising arterial spin labeling MRI using tissue partial volume
    • Dawant BM, Hayno DR, editors. San Diego: SPIE
    • Petr J, Ferré J-C, Gauvrit J-Y, Barillot C. Denoising arterial spin labeling MRI using tissue partial volume. In: Dawant BM, Hayno DR, editors. SPIE medical imaging 2010: image processing. San Diego: SPIE; 2010. p 76230-76239.
    • (2010) SPIE Medical Imaging 2010: Image Processing , pp. 76230-76239
    • Petr, J.1    Ferré, J.-C.2    Gauvrit, J.-Y.3    Barillot, C.4
  • 16
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • DOI 10.1002/jmri.20969
    • Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 2007;26:375-385. (Pubitemid 47257737)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.2 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3    Reiser, M.F.4    Schoenberg, S.O.5
  • 17
    • 4444334451 scopus 로고    scopus 로고
    • Current concepts and advances in clinical parallel magnetic resonance imaging
    • DOI 10.1097/01.rmr.0000139666.23921.27
    • Bammer R, Schoenberg SO. Current concepts and advances in clinical parallel magnetic resonance imaging. Top Magn Reson Imaging 2004;15:129-158. (Pubitemid 39187202)
    • (2004) Topics in Magnetic Resonance Imaging , vol.15 , Issue.3 , pp. 129-158
    • Bammer, R.1    Schoenberg, S.O.2
  • 18
    • 0034789167 scopus 로고    scopus 로고
    • Physiological noise in oxygenation-sensitive magnetic resonance imaging
    • DOI 10.1002/mrm.1240
    • Kruger G, Glover GH. Physiological noise in oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 2001;46:631-637. (Pubitemid 32906131)
    • (2001) Magnetic Resonance in Medicine , vol.46 , Issue.4 , pp. 631-637
    • Kruger, G.1    Glover, G.H.2
  • 19
    • 15944423506 scopus 로고    scopus 로고
    • Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity
    • DOI 10.1002/jmri.20288
    • Vogt FM, Antoch G, Hunold P, et al. Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity. J Magn Reson Imaging 2005;21:376-382. (Pubitemid 40446432)
    • (2005) Journal of Magnetic Resonance Imaging , vol.21 , Issue.4 , pp. 376-382
    • Vogt, F.M.1    Antoch, G.2    Hunold, P.3    Maderwald, S.4    Ladd, M.E.5    Debatin, J.F.6    Ruehm, S.G.7
  • 20
    • 33847099530 scopus 로고    scopus 로고
    • Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging
    • Bhagat YA, Emery DJ, Naik S, Yeo T, Beaulieu C. Comparison of generalized autocalibrating partially parallel acquisitions and modified sensitivity encoding for diffusion tensor imaging. AJNR Am J Neuroradiol 2007;28:293-298. (Pubitemid 46281049)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.2 , pp. 293-298
    • Bhagat, Y.A.1    Emery, D.J.2    Naik, S.3    Yeo, T.4    Beaulieu, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.