메뉴 건너뛰기




Volumn 27, Issue 2, 2012, Pages 953-962

Sensor network for monitoring the state of pollution of high-voltage insulators via satellite

Author keywords

Insulators; leakage current; microcontrollers; optical signal detection; partial discharges (PDs); power transmission lines; satellite mobile communication; transducers

Indexed keywords

DESIGN AND DEVELOPMENT; ELECTRONIC PROCESSING; HIGH-VOLTAGES; LONG-TERM MEASUREMENTS; MEASURED DATA; MONITORING POINTS; NORTHEAST BRAZIL; OPTICAL SIGNAL DETECTION; POLLUTION LEVEL; PRELIMINARY ANALYSIS; REMOTE MONITORING; SATELLITE MOBILE COMMUNICATIONS; SENSOR SYSTEMS; TRANSMISSION TOWER;

EID: 84859771745     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2012.2183623     Document Type: Article
Times cited : (31)

References (17)
  • 1
    • 0028529561 scopus 로고
    • Physics and chemistry of partial discharge and corona-recent advances and future challenges
    • Oct.
    • R. J. Van Brunt, "Physics and chemistry of partial discharge and corona-recent advances and future challenges," IEEE Trans. Dielect. Elect. Insul., vol. 1, no. 5, pp. 761-784, Oct. 1994.
    • (1994) IEEE Trans. Dielect. Elect. Insul. , vol.1 , Issue.5 , pp. 761-784
    • Van Brunt, R.J.1
  • 2
    • 3042662022 scopus 로고    scopus 로고
    • Correlation among ESDD, NSDD and leakage current in distribution insulators
    • G. Montoya, I. Ramirez, and J. I. Montoya, "Correlation among ESDD, NSDD and leakage current in distribution insulators," Proc. Inst. Elect. Eng., Gen., Transm. Distrib., vol. 151, no. 3, pp. 334-340, 2004.
    • (2004) Proc. Inst. Elect. Eng., Gen., Transm. Distrib. , vol.151 , Issue.3 , pp. 334-340
    • Montoya, G.1    Ramirez, I.2    Montoya, J.I.3
  • 3
    • 0035696051 scopus 로고    scopus 로고
    • Remote monitoring of surface current over insulators
    • Atlanta, GA
    • M. Youssef and A. A. El-Alayly, "Remote monitoring of surface current over insulators," in Proc. IEEE Transm. Distrib. Conf., Atlanta, GA, 2001, pp. 113-116.
    • (2001) Proc. IEEE Transm. Distrib. Conf. , pp. 113-116
    • Youssef, M.1    El-Alayly, A.A.2
  • 5
    • 12544250986 scopus 로고    scopus 로고
    • Frequency characteristics of leakage current waveforms of a string of suspension insulators
    • Jan.
    • T. Suda, "Frequency characteristics of leakage current waveforms of a string of suspension insulators," IEEE Trans. Power Del., vol. 20, no. 1, pp. 481-487, Jan. 2005.
    • (2005) IEEE Trans. Power Del. , vol.20 , Issue.1 , pp. 481-487
    • Suda, T.1
  • 7
    • 0028758627 scopus 로고
    • Practical on-line partial discharge measuring system for high voltage apparatus
    • Jul.
    • S. Moorthy, S. Shihab, and X. cheng, "Practical on-line partial discharge measuring system for high voltage apparatus," in Proc. IEEE Prop. Appl. Dielect. Mater., Jul. 1994, pp. 586-589.
    • (1994) Proc. IEEE Prop. Appl. Dielect. Mater. , pp. 586-589
    • Moorthy, S.1    Shihab, S.2    Cheng, X.3
  • 8
    • 0026264454 scopus 로고
    • A mathematical model to study the influence of source parameters in polluted insulator tests
    • Jul.
    • R. W. S. Garcia, N. H. C. Santiago, and C. M. Portela, "A mathematical model to study the influence of source parameters in polluted insulator tests," in Proc. IEEE Prop. Appl. Dielect. Mater., Jul. 1991, pp. 953-956.
    • (1991) Proc. IEEE Prop. Appl. Dielect. Mater. , pp. 953-956
    • Garcia, R.W.S.1    Santiago, N.H.C.2    Portela, C.M.3
  • 11
    • 0025682246 scopus 로고
    • Development of real-time system for simultaneous observation of visual discharges and leakage current on contaminated dc insulators
    • Dec.
    • K. Isaka, Y. Yokoi, K. Naito, R. Matsuoka, S. Ito, K. Sakanishi, and O. Fujii, "Development of real-time system for simultaneous observation of visual discharges and leakage current on contaminated dc insulators," IEEE Trans. Dielect. Elect. Insul., vol. 25, no. 6, pp. 1153-1160, Dec. 1990.
    • (1990) IEEE Trans. Dielect. Elect. Insul. , vol.25 , Issue.6 , pp. 1153-1160
    • Isaka, K.1    Yokoi, Y.2    Naito, K.3    Matsuoka, R.4    Ito, S.5    Sakanishi, K.6    Fujii, O.7
  • 14
    • 67649598316 scopus 로고    scopus 로고
    • Optical detection of partial discharges on insulator strings of high-voltage transmission lines
    • Jul.
    • S. C. Oliveira and E. Fontana, "Optical detection of partial discharges on insulator strings of high-voltage transmission lines," IEEE Trans. Instrum. Meas., vol. 58, no. 7, pp. 2328-2334, Jul. 2009.
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.7 , pp. 2328-2334
    • Oliveira, S.C.1    Fontana, E.2
  • 17
    • 84859746069 scopus 로고    scopus 로고
    • Programa de pós-graduaçao em engenharia elétrica da UFPE, PPGEEUFPE. (2010)," Satellite telemetry system for pollution detection of high-voltage insulator strings. [Online]. Available:
    • "Programa de pós-graduaçao em engenharia elétrica da UFPE, PPGEEUFPE. (2010)," Satellite telemetry system for pollution detection of high-voltage insulator strings. [Online]. Available: http://www.youtube.com/watch?v=sU2ZCD-fsYU


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.