메뉴 건너뛰기




Volumn 58, Issue 7, 2009, Pages 2328-2334

Optical detection of partial discharges on insulator strings of high-voltage transmission lines

Author keywords

Flashover; Insulators; Leakage current; Lightemitting diodes (LEDs); Optical fiber transducers; Partial discharges; Power transmission lines

Indexed keywords

CURRENT DETECTION; HIGH VOLTAGE TRANSMISSION LINES; HIGH-VOLTAGE; INSULATOR STRING; INSULATORS; LEAKAGE CURRENT SENSORS; LIGHTEMITTING DIODES (LEDS); OPTICAL DETECTION; OPTICAL FIBER TRANSDUCERS; OVERHEAD TRANSMISSION LINES; POLLUTION LEVEL; POWER TRANSMISSION LINES; PROCESSING MODULES; RELATIVE HUMIDITIES;

EID: 67649598316     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIM.2009.2013924     Document Type: Conference Paper
Times cited : (32)

References (18)
  • 1
    • 0028529561 scopus 로고
    • Physics and chemistry of partial discharge and corona - Recent advances and future challenges
    • Oct
    • R. J. Van Brunt, "Physics and chemistry of partial discharge and corona - Recent advances and future challenges," IEEE Trans. Dielectr. Elect. Insul., vol. 1, no. 5, pp. 761-784, Oct. 1994.
    • (1994) IEEE Trans. Dielectr. Elect. Insul , vol.1 , Issue.5 , pp. 761-784
    • Van Brunt, R.J.1
  • 2
    • 3042662022 scopus 로고    scopus 로고
    • Correlation among ESDD, NSDD and leakage current in distribution insulators
    • May
    • G. Montoya, I. Ramirez, and J. I. Montoya, "Correlation among ESDD, NSDD and leakage current in distribution insulators," Proc. Inst. Elect. Eng. - Gener., Transmiss. Distrib., vol. 151, no. 3, pp. 334-340, May 2004.
    • (2004) Proc. Inst. Elect. Eng. - Gener., Transmiss. Distrib , vol.151 , Issue.3 , pp. 334-340
    • Montoya, G.1    Ramirez, I.2    Montoya, J.I.3
  • 3
    • 0033076769 scopus 로고    scopus 로고
    • Relation between leakage impedance and equivalent salt deposit density on an insulator under a saltwater spray
    • Feb
    • H. Matsuo, T. Fujishima, and T. Yamashita, "Relation between leakage impedance and equivalent salt deposit density on an insulator under a saltwater spray," IEEE Trans. Dielectr. Elect. Insul., vol. 6, no. 1, pp. 117-121, Feb. 1999.
    • (1999) IEEE Trans. Dielectr. Elect. Insul , vol.6 , Issue.1 , pp. 117-121
    • Matsuo, H.1    Fujishima, T.2    Yamashita, T.3
  • 4
    • 0032187641 scopus 로고    scopus 로고
    • Development of a new apparatus for contamination measurements of overhead transmission line insulators
    • Oct
    • K. Iwai, Y. Hase, E. Nakamura, and H. Katsukawa, "Development of a new apparatus for contamination measurements of overhead transmission line insulators," IEEE Trans. Power Del., vol. 13, no. 4, pp. 1412-1417, Oct. 1998.
    • (1998) IEEE Trans. Power Del , vol.13 , Issue.4 , pp. 1412-1417
    • Iwai, K.1    Hase, Y.2    Nakamura, E.3    Katsukawa, H.4
  • 5
    • 60249083436 scopus 로고    scopus 로고
    • Scintillation modeling for insulator string under polluted conditions
    • Aug. 23-27
    • D. C. Chaurasia, "Scintillation modeling for insulator string under polluted conditions," in Proc. 11th Int. Symp. High Voltage Eng., Aug. 23-27, 1999, vol. 4, pp. 224-227.
    • (1999) Proc. 11th Int. Symp. High Voltage Eng , vol.4 , pp. 224-227
    • Chaurasia, D.C.1
  • 7
    • 12544250986 scopus 로고    scopus 로고
    • Frequency characteristics of leakage current waveforms of a string of suspension insulators
    • Jan
    • T. Suda, "Frequency characteristics of leakage current waveforms of a string of suspension insulators," IEEE Trans. Power Del., vol. 20, no. 1, pp. 481-487, Jan. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.1 , pp. 481-487
    • Suda, T.1
  • 9
    • 0028758627 scopus 로고
    • Practical on-line partial discharge measuring system for high voltage apparatus
    • Jul
    • S. Moorthy, S. Shihab, and X. Cheng, "Practical on-line partial discharge measuring system for high voltage apparatus," in Proc. IEEE Properties Appl. Dielectr. Mater., Jul. 1994, pp. 586-589.
    • (1994) Proc. IEEE Properties Appl. Dielectr. Mater , pp. 586-589
    • Moorthy, S.1    Shihab, S.2    Cheng, X.3
  • 10
    • 0026264454 scopus 로고
    • A mathematical model to study the influence of source parameters in polluted insulator tests
    • Jul
    • R. W. S. Garcia, N. H. C. Santiago, and C. M. Portela, "A mathematical model to study the influence of source parameters in polluted insulator tests," in Proc. IEEE Properties Appl. Dielectr. Mater., Jul. 1991, pp. 953-956.
    • (1991) Proc. IEEE Properties Appl. Dielectr. Mater , pp. 953-956
    • Garcia, R.W.S.1    Santiago, N.H.C.2    Portela, C.M.3
  • 13
    • 0025682246 scopus 로고
    • Development of real-time system for simultaneous observation of visual discharges and leakage current on contaminated DC insulators
    • Dec
    • K. Isaka, Y. Yokoi, K. Naito, R. Matsuoka, S. Ito, K. Sakanishi, and O. Fujii, "Development of real-time system for simultaneous observation of visual discharges and leakage current on contaminated DC insulators," IEEE Trans. Dielectr. Elect. Insul., vol. 25, no. 6, pp. 1153-1160, Dec. 1990.
    • (1990) IEEE Trans. Dielectr. Elect. Insul , vol.25 , Issue.6 , pp. 1153-1160
    • Isaka, K.1    Yokoi, Y.2    Naito, K.3    Matsuoka, R.4    Ito, S.5    Sakanishi, K.6    Fujii, O.7
  • 14
    • 0035696051 scopus 로고    scopus 로고
    • Remote monitoring of surface current over insulators
    • Nov
    • M. Youssef and A. A. El-Alayly, "Remote monitoring of surface current over insulators," in Proc. IEEE Transmiss. Distrib. Conf., Nov. 2001, vol. 1, pp. 113-116.
    • (2001) Proc. IEEE Transmiss. Distrib. Conf , vol.1 , pp. 113-116
    • Youssef, M.1    El-Alayly, A.A.2
  • 17
    • 67649612672 scopus 로고    scopus 로고
    • M. Bass, Handbook of Optics, 2nd ed, 1. New York: McGraw-Hill, 1995, p. 15.5.
    • M. Bass, Handbook of Optics, 2nd ed, vol. 1. New York: McGraw-Hill, 1995, p. 15.5.
  • 18
    • 0030258997 scopus 로고    scopus 로고
    • A novel Fourier technique for calculating fiber-to-LED coupling efficiency with lateral and longitudinal misalignments
    • Oct
    • S.-C. Wang and M. N. Ingram, "A novel Fourier technique for calculating fiber-to-LED coupling efficiency with lateral and longitudinal misalignments," J. Lightw. Technol., vol. 14, no. 10, pp. 2407-2413, Oct. 1996.
    • (1996) J. Lightw. Technol , vol.14 , Issue.10 , pp. 2407-2413
    • Wang, S.-C.1    Ingram, M.N.2