메뉴 건너뛰기




Volumn 25, Issue 2, 2012, Pages 123-128

A study of low elastic modulus expandable pedicle screws in osteoporotic sheep

Author keywords

biomechanics; elastic modulus; expandable pedicle screw; micro CT; osteoporosis; screw bone interface

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BONE DENSITY; CONTROLLED STUDY; FEMALE; FIXATION DEVICE; HISTOLOGY; INFLAMMATION; LOW ELASTIC MODULUS EXPANDABLE PEDICLE SCREW; LUMBAR SPINE; NONHUMAN; OSTEOPOROSIS; PEDICLE SCREW; PRIORITY JOURNAL; SHEEP;

EID: 84859633153     PISSN: 15360652     EISSN: 15392465     Source Type: Journal    
DOI: 10.1097/BSD.0b013e31820ef9f7     Document Type: Article
Times cited : (18)

References (34)
  • 1
    • 0033794424 scopus 로고    scopus 로고
    • The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
    • Gains RW Jr. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg. 2000;82- A:1458-1476.
    • (2000) J Bone Joint Surg , vol.82 A , pp. 1458-1476
    • Gains Jr., R.W.1
  • 2
    • 77649325980 scopus 로고    scopus 로고
    • One-stage combined posterior and anterior approaches for excising thoracolumbar and lumbar tumors: Surgical and oncological outcomes
    • Hu Y, Xia Q, Ji J, et al. One-stage combined posterior and anterior approaches for excising thoracolumbar and lumbar tumors: surgical and oncological outcomes. Spine (Phila Pa 1976). 2010;35:590-595.
    • (2010) Spine (Phila Pa 1976) , vol.35 , pp. 590-595
    • Hu, Y.1    Xia, Q.2    Ji, J.3
  • 3
    • 70349733419 scopus 로고    scopus 로고
    • Thoracic pedicle screw instrumentation: The learning curve and evolution in technique in the treatment of adolescent idiopathic scoliosis
    • Lonner BS, Auerbach JD, Estreicher MB, et al. Thoracic pedicle screw instrumentation: the learning curve and evolution in technique in the treatment of adolescent idiopathic scoliosis. Spine (Phila Pa 1976). 2009;34:2158-2164.
    • (2009) Spine (Phila Pa 1976) , vol.34 , pp. 2158-2164
    • Lonner, B.S.1    Auerbach, J.D.2    Estreicher, M.B.3
  • 4
    • 56349095102 scopus 로고    scopus 로고
    • Assessment of different screw augmentation techniques and screw designs in osteoporotic spines
    • Becker S, Chavanne A, Spitaler R, et al. Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J. 2008;17:1462-1469.
    • (2008) Eur Spine J , vol.17 , pp. 1462-1469
    • Becker, S.1    Chavanne, A.2    Spitaler, R.3
  • 5
    • 34548422314 scopus 로고    scopus 로고
    • Double pedicle screw instrumentation in the osteoporotic spine: A biomechanical feasibility study
    • DOI 10.1097/BSD.0b013e318030e945, PII 0002472020070800000004
    • Jiang L, Arlet V, Beckman L, et al. Double pedicle screw instrumentation in the osteoporotic spine: a biomechanical feasibility study. J Spinal Disord Tech. 2007;20:430-435. (Pubitemid 47357500)
    • (2007) Journal of Spinal Disorders and Techniques , vol.20 , Issue.6 , pp. 430-435
    • Jiang, L.1    Arlet, V.2    Beckman, L.3    Steffen, T.4
  • 6
    • 41949110636 scopus 로고    scopus 로고
    • Increasing bending strength and pullout strength in conical pedicle screws: Biomechanical tests and finite element analyses
    • Chao CK, Hsu CC, Wang JL, et al. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. J Spinal Disord Tech. 2008;21:130-138.
    • (2008) J Spinal Disord Tech , vol.21 , pp. 130-138
    • Chao, C.K.1    Hsu, C.C.2    Wang, J.L.3
  • 8
    • 0033771307 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: In vitro comparison with two established implant systems
    • Richter M, Wilke HJ, Kluger P, et al. Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in vitro comparison with two established implant systems. Eur Spine J. 2000;9:417-425.
    • (2000) Eur Spine J , vol.9 , pp. 417-425
    • Richter, M.1    Wilke, H.J.2    Kluger, P.3
  • 9
    • 79958207834 scopus 로고    scopus 로고
    • Augmentation of pedicle screw stability with calcium sulfate cement in osteoporotic sheep: Biomechanical and screw-bone interfacial evaluation
    • Liu D, Lei W, Wu ZX, et al. Augmentation of pedicle screw stability with calcium sulfate cement in osteoporotic sheep: biomechanical and screw-bone interfacial evaluation. J Spinal Disord Tech. 2011;24: 235-241.
    • (2011) J Spinal Disord Tech , vol.24 , pp. 235-241
    • Liu, D.1    Lei, W.2    Wu, Z.X.3
  • 10
    • 34748828574 scopus 로고    scopus 로고
    • Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant: Technical note and report of three cases
    • DOI 10.3171/SPI-07/09/366
    • Fransen P. Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant. Technical note and report of three cases. J Neurosurg Spine. 2007;7:366-369. (Pubitemid 47480467)
    • (2007) Journal of Neurosurgery: Spine , vol.7 , Issue.3 , pp. 366-369
    • Fransen, P.1
  • 12
    • 70350247738 scopus 로고    scopus 로고
    • Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone
    • Tami AE, Leitner MM, Baucke MG, et al. Hydroxyapatite particles maintain peri-implant bone mantle during osseointegration in osteoporotic bone. Bone. 2009;45:1117-1124.
    • (2009) Bone , vol.45 , pp. 1117-1124
    • Tami, A.E.1    Leitner, M.M.2    Baucke, M.G.3
  • 13
  • 14
    • 68149098997 scopus 로고    scopus 로고
    • 1150 Kyphoplasties over 7 years: Indications, techniques, and intraoperative complications
    • McArthur N, Kasperk C, Baier M, et al. 1150 kyphoplasties over 7 years: indications, techniques, and intraoperative complications. Orthopedics. 2009;32:90.
    • (2009) Orthopedics , vol.32 , pp. 90
    • McArthur, N.1    Kasperk, C.2    Baier, M.3
  • 15
    • 0034463634 scopus 로고    scopus 로고
    • Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    • DOI 10.1097/00002517-200006000-00006
    • Cook SD, Salkeld SL, Whitecloud TS III, et al. Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord. 2000;13:230-236. (Pubitemid 32201548)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.3 , pp. 230-236
    • Cook, S.D.1    Salkeld, S.L.2    Whitecloud III, T.S.3    Barbera, J.4
  • 16
    • 0042919361 scopus 로고    scopus 로고
    • Lumbosacral fixation using expandable pedicle screws: An alternative in reoperation and osteoporosis
    • DOI 10.1016/S1529-9430(01)00020-1, PII S1529943001000201
    • Cook SD, Barbera J, Rubi M, et al. Lumbosacral fixation using expandable pedicle screws: an alternative in reoperation and osteoporosis. Spine J. 2001;1:109-114. (Pubitemid 33628833)
    • (2001) Spine Journal , vol.1 , Issue.2 , pp. 109-114
    • Cook, S.D.1    Barbera, J.2    Rubi, M.3    Salkeld, S.L.4    Whitecloud III, T.S.5
  • 17
    • 0034913909 scopus 로고    scopus 로고
    • An expandable anchor for fixation in osteoporotic bone
    • DOI 10.1016/S0736-0266(00)00052-8
    • McKoy BE, An YH. An expandable anchor for fixation in osteoporotic bone. J Orthop Res. 2001;19:545-547. (Pubitemid 32700965)
    • (2001) Journal of Orthopaedic Research , vol.19 , Issue.4 , pp. 545-547
    • McKoy, B.E.1    An, Y.H.2
  • 18
    • 0034463634 scopus 로고    scopus 로고
    • Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    • DOI 10.1097/00002517-200006000-00006
    • Stephen DC, Salkeld SL, Whitecloud TS III, et al. Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord. 2000;13:230-236. (Pubitemid 32201548)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.3 , pp. 230-236
    • Cook, S.D.1    Salkeld, S.L.2    Whitecloud III, T.S.3    Barbera, J.4
  • 19
    • 33644641656 scopus 로고    scopus 로고
    • Biomechanical evaluation of an expansive pedicle screw in calf vertebrae
    • DOI 10.1007/s00586-004-0867-1
    • Lei W, Wu ZX. Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J. 2006;15:321-326. (Pubitemid 43327666)
    • (2006) European Spine Journal , vol.15 , Issue.3 , pp. 321-326
    • Lei, W.1    Wu, Z.2
  • 20
    • 79952685426 scopus 로고    scopus 로고
    • Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep
    • Wan S, Lei W, Wu Z, et al. Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep. Eur Spine J. 2010;19:2122-2129.
    • (2010) Eur Spine J , vol.19 , pp. 2122-2129
    • Wan, S.1    Lei, W.2    Wu, Z.3
  • 23
    • 33846884619 scopus 로고    scopus 로고
    • Elastic deformation behaviour of Ti-24Nb-4Zr-7.9Sn for biomedical applications
    • DOI 10.1016/j.actbio.2006.11.002, PII S1742706106001528
    • Hao YL, Li SJ, Sun SY. Elastic deformation behaviour of Ti-24Nb-4Zr-7.9Sn for biomedical applications. Acta Biomater. 2007;3: 277-286. (Pubitemid 46223901)
    • (2007) Acta Biomaterialia , vol.3 , Issue.2 , pp. 277-286
    • Hao, Y.L.1    Li, S.J.2    Sun, S.Y.3    Zheng, C.Y.4    Yang, R.5
  • 26
    • 0038386323 scopus 로고    scopus 로고
    • Influence of the stiffness of bone defect implants on the mechanical conditions at the interface - A finite element analysis with contact
    • DOI 10.1016/S0021-9290(03)00114-3
    • Simon U, Augat P, Ignatius A, et al. Influence in the stiffness of bone defect implants on the mechanical conditions at the interface-a finite element analysis with contact. J Biomech. 2003;36:1079-1086. (Pubitemid 36794103)
    • (2003) Journal of Biomechanics , vol.36 , Issue.8 , pp. 1079-1086
    • Simon, U.1    Augat, P.2    Ignatius, A.3    Claes, L.4
  • 27
    • 33847626692 scopus 로고    scopus 로고
    • Bone formation at the surface of low modulus Ti-7.5Mo implants in rabbit femur
    • Lin DJ, Chuang CC, Chern Lin JH, et al. Bone formation at the surface of low modulus Ti-7.5Mo implants in rabbit femur. Biomaterials. 2007;28:2582-2589.
    • (2007) Biomaterials , vol.28 , pp. 2582-2589
    • Lin, D.J.1    Chuang, C.C.2    Chern Lin, J.H.3
  • 28
    • 62849125345 scopus 로고    scopus 로고
    • The effects of nail rigidity on bone healing of rats with osteoporosis
    • Sha M, Guo Z, Fu J, et al. The effects of nail rigidity on bone healing of rats with osteoporosis. Acta Orthop. 2009;80:135-138.
    • (2009) Acta Orthop , vol.80 , pp. 135-138
    • Sha, M.1    Guo, Z.2    Fu, J.3
  • 29
    • 33847774370 scopus 로고    scopus 로고
    • Three-dimensional microcomputed tomographic imaging of alveolar bone in experimental bone loss or repair
    • Park CH, Abramson ZR, Taba M, et al. Three-dimensional microcomputed tomographic imaging of alveolar bone in experimental bone loss or repair. J Periodontol. 2007;78:273-281.
    • (2007) J Periodontol , vol.78 , pp. 273-281
    • Park, C.H.1    Abramson, Z.R.2    Taba, M.3
  • 31
    • 0031788127 scopus 로고    scopus 로고
    • Mechanobiology of skeletal regeneration
    • Carter DR, Beaupre GS, Giori NJ, et al. Mechanobiology of skeletal regeneration. Clin Orthop. 1998;355(suppl):41-55.
    • (1998) Clin Orthop , vol.355 , Issue.SUPPL. , pp. 41-55
    • Carter, D.R.1    Beaupre, G.S.2    Giori, N.J.3
  • 32
    • 0035062762 scopus 로고    scopus 로고
    • Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains
    • DOI 10.1016/S0736-0266(00)90006-8
    • Simmons CA, Shaker AM, Pilliar RM. Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains. J Orthop Res. 2001;19:187-194. (Pubitemid 32331691)
    • (2001) Journal of Orthopaedic Research , vol.19 , Issue.2 , pp. 187-194
    • Simmons, C.A.1    Meguid, S.A.2    Pilliar, R.M.3
  • 34
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • DOI 10.1002/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, et al. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998; 43:192-203. (Pubitemid 28246972)
    • (1998) Journal of Biomedical Materials Research , vol.43 , Issue.2 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.