메뉴 건너뛰기




Volumn 86, Issue 5, 2012, Pages 1222-1231

A new dynamic test method for thermal performance of all-glass evacuated solar air collectors

Author keywords

All glass evacuated tube; Dynamic method; Solar air collector; Thermal performance

Indexed keywords

AIR; COLLECTOR EFFICIENCY; GLASS; TESTING;

EID: 84859441738     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2012.01.015     Document Type: Article
Times cited : (52)

References (14)
  • 1
    • 0033133623 scopus 로고    scopus 로고
    • A new dynamic method for testing solar flat-plate collectors under variable weather
    • Amer E.H., Nayak J.K., et al. A new dynamic method for testing solar flat-plate collectors under variable weather. Energy Conversion and Management 1999, 40(8):803-823.
    • (1999) Energy Conversion and Management , vol.40 , Issue.8 , pp. 803-823
    • Amer, E.H.1    Nayak, J.K.2
  • 2
    • 84862792886 scopus 로고    scopus 로고
    • ASHRAE 93-2003. Methods of Testing to Determine the Thermal Performance of Solar Collectors.
    • ASHRAE 93-2003, 2003. Methods of Testing to Determine the Thermal Performance of Solar Collectors.
    • (2003)
  • 3
    • 56949088021 scopus 로고    scopus 로고
    • Performance of water-in-glass evacuated tube solar water heaters
    • Budihardjo I., Morrison G.L. Performance of water-in-glass evacuated tube solar water heaters. Solar Energy 2009, 83(1):49-56.
    • (2009) Solar Energy , vol.83 , Issue.1 , pp. 49-56
    • Budihardjo, I.1    Morrison, G.L.2
  • 4
    • 84862780766 scopus 로고    scopus 로고
    • EN 12975-1. Thermal Solar Systems and Components - Solar Collectors - Part 1: General Requirements.
    • EN 12975-1, 2006. Thermal Solar Systems and Components - Solar Collectors - Part 1: General Requirements.
    • (2006)
  • 5
    • 0347028563 scopus 로고    scopus 로고
    • Collector test method under quasi-dynamic conditions according to the European Standard EN 12975-2
    • Fischer S., Heidemann W., et al. Collector test method under quasi-dynamic conditions according to the European Standard EN 12975-2. Solar Energy 2004, 76(1):117-123.
    • (2004) Solar Energy , vol.76 , Issue.1 , pp. 117-123
    • Fischer, S.1    Heidemann, W.2
  • 6
    • 84862824458 scopus 로고    scopus 로고
    • Research on Dynamic Thermal Performance test Method of Solar Collectors. PH.D. Thesis, Shanghai Jiao Tong University, Shanghai, China.
    • Hou, H., 2005. Research on Dynamic Thermal Performance test Method of Solar Collectors. PH.D. Thesis, Shanghai Jiao Tong University, Shanghai, China.
    • (2005)
    • Hou, H.1
  • 7
    • 10944274134 scopus 로고    scopus 로고
    • A new method for the measurement of solar collector time constant
    • Hou H.J., Wang Z.F., et al. A new method for the measurement of solar collector time constant. Renewable Energy 2005, 30(6):855-865.
    • (2005) Renewable Energy , vol.30 , Issue.6 , pp. 855-865
    • Hou, H.J.1    Wang, Z.F.2
  • 8
    • 84862824462 scopus 로고
    • ISO 9806-1. Test Methods for Solar Collectors - Part 1: Thermal Performance of Glazed Liquid Heating Collectors Including Pressure Drop.
    • ISO 9806-1, 1994. Test Methods for Solar Collectors - Part 1: Thermal Performance of Glazed Liquid Heating Collectors Including Pressure Drop.
    • (1994)
  • 9
    • 33750716036 scopus 로고    scopus 로고
    • Uncertainty calculation applied to different regression methods in the quasi-dynamic collector test
    • Kratzenberg M.G., Beyer H.G., et al. Uncertainty calculation applied to different regression methods in the quasi-dynamic collector test. Solar Energy 2006, 80(11):1453-1462.
    • (2006) Solar Energy , vol.80 , Issue.11 , pp. 1453-1462
    • Kratzenberg, M.G.1    Beyer, H.G.2
  • 10
    • 80051595596 scopus 로고    scopus 로고
    • Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube
    • Liang R.B., Ma L.D., et al. Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube. Solar Energy 2011, 85(9):1735-1744.
    • (2011) Solar Energy , vol.85 , Issue.9 , pp. 1735-1744
    • Liang, R.B.1    Ma, L.D.2
  • 11
    • 77952584857 scopus 로고    scopus 로고
    • Thermal performance analysis of the glass evacuated tube solar collector with U-tube
    • Ma L.D., Lu Z., et al. Thermal performance analysis of the glass evacuated tube solar collector with U-tube. Building and Environment 2010, 45(9):1959-1967.
    • (2010) Building and Environment , vol.45 , Issue.9 , pp. 1959-1967
    • Ma, L.D.1    Lu, Z.2
  • 12
    • 0033651356 scopus 로고    scopus 로고
    • Experimental and theoretical evaluation of dynamic test procedures for solar flat-plate collectors
    • Nayak J.K., Amer E.H. Experimental and theoretical evaluation of dynamic test procedures for solar flat-plate collectors. Solar Energy 2000, 69(5):377-401.
    • (2000) Solar Energy , vol.69 , Issue.5 , pp. 377-401
    • Nayak, J.K.1    Amer, E.H.2
  • 13
    • 79956094160 scopus 로고    scopus 로고
    • Comparative studies on thermal performance of water-in-glass evacuated tube solar water heaters with different collector tilt-angles
    • Tang R., Yang Y., et al. Comparative studies on thermal performance of water-in-glass evacuated tube solar water heaters with different collector tilt-angles. Solar Energy 2011, 85(7):1381-1389.
    • (2011) Solar Energy , vol.85 , Issue.7 , pp. 1381-1389
    • Tang, R.1    Yang, Y.2
  • 14
    • 77954312142 scopus 로고    scopus 로고
    • Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions
    • Zambolin E., Del Col D. Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions. Solar Energy 2010, 84(8):1382-1396.
    • (2010) Solar Energy , vol.84 , Issue.8 , pp. 1382-1396
    • Zambolin, E.1    Del Col, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.