메뉴 건너뛰기




Volumn 84, Issue 8, 2010, Pages 1382-1396

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

Author keywords

Daily efficiency; Efficiency; Evacuated tube collector; Flat plate collector; Quasi dynamic method

Indexed keywords

COMPARATIVE TESTS; COMPOUND PARABOLIC CONCENTRATOR; DAILY EFFICIENCY; DIRECT FLOW; DYNAMIC CONDITION; DYNAMIC METHOD; DYNAMIC TESTS; ENERGY PERFORMANCE; EVACUATED COLLECTOR; EVACUATED TUBE COLLECTORS; EVACUATED TUBE SOLAR COLLECTOR; EXPERIMENTAL ANALYSIS; FLAT PLATE; FLAT-PLATE COLLECTOR; HOT WATER; INCIDENCE ANGLES; INPUT/OUTPUT; SOLAR COOLING; TEMPERATURE DIFFERENCES; TEST RUNS; THERMAL PERFORMANCE; VARIABLE CONDITIONS; WORKING CONDITIONS;

EID: 77954312142     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2010.04.020     Document Type: Article
Times cited : (265)

References (25)
  • 2
    • 56949088021 scopus 로고    scopus 로고
    • Performance of water-in-glass evacuated tube solar water heaters
    • Budihardjo I., Morrison G.L. Performance of water-in-glass evacuated tube solar water heaters. Solar Energy 2009, 83:49-56.
    • (2009) Solar Energy , vol.83 , pp. 49-56
    • Budihardjo, I.1    Morrison, G.L.2
  • 3
    • 77954311398 scopus 로고    scopus 로고
    • Comparison between test methods for parameters determination of flat plate solar collectors in transient conditions. In: 63rd ATI Congress (in Italian).
    • Cucumo, M., Cucumo, S., De Rosa, A., Ferraro, V., Kaliakatsos, D., Marinelli, V., 2008. Comparison between test methods for parameters determination of flat plate solar collectors in transient conditions. In: 63rd ATI Congress (in Italian).
    • (2008)
    • Cucumo, M.1    Cucumo, S.2    De Rosa, A.3    Ferraro, V.4    Kaliakatsos, D.5    Marinelli, V.6
  • 4
    • 77954310260 scopus 로고    scopus 로고
    • New experimental apparatus for testing the performance of solar collectors. In: 62nd ATI Congress.
    • Del Col, D., Padovan, A., 2007. New experimental apparatus for testing the performance of solar collectors. In: 62nd ATI Congress.
    • (2007)
    • Del Col, D.1    Padovan, A.2
  • 6
    • 77954314794 scopus 로고    scopus 로고
    • Solar engineering of thermal processes (Chapter 6).
    • Duffie, A., Beckman, W.A., 2006. Solar engineering of thermal processes (Chapter 6).
    • (2006)
    • Duffie, A.1    Beckman, W.A.2
  • 7
    • 77954313424 scopus 로고    scopus 로고
    • EN 12975-2, Thermal Solar Systems and Components - Solar Collectors - Part 2: Test Methods.
    • EN 12975-2, 2006. Thermal Solar Systems and Components - Solar Collectors - Part 2: Test Methods.
    • (2006)
  • 9
    • 0018985293 scopus 로고
    • Incidence angle modifier and average optical efficiency of parabolic trough collectors
    • Gaul H., Rabl A. Incidence angle modifier and average optical efficiency of parabolic trough collectors. Transactions of ASME, Journal of Solar Energy Engineering 1980, 102:547-551.
    • (1980) Transactions of ASME, Journal of Solar Energy Engineering , vol.102 , pp. 547-551
    • Gaul, H.1    Rabl, A.2
  • 10
    • 44249085139 scopus 로고    scopus 로고
    • Experimental investigation of novel indirect solar cooker with indoor PCM thermal storage and cooking unit
    • Hussein H.M.S., El-Ghetany H.H., Nada S.A. Experimental investigation of novel indirect solar cooker with indoor PCM thermal storage and cooking unit. Energy Conversion and Management 2008, 49:2237-2246.
    • (2008) Energy Conversion and Management , vol.49 , pp. 2237-2246
    • Hussein, H.M.S.1    El-Ghetany, H.H.2    Nada, S.A.3
  • 11
    • 77954313755 scopus 로고
    • ISO, Guide to the Expression of Uncertainty in Measurement.
    • ISO, 1995. Guide to the Expression of Uncertainty in Measurement.
    • (1995)
  • 12
    • 0040958804 scopus 로고    scopus 로고
    • Comparison between inverted absorber asymmetric and symmetric tubular-absorber compound parabolic concentrating solar collectors
    • Kothdiwala A.F., Eames P.C., Norton B., Zacharopolous A. Comparison between inverted absorber asymmetric and symmetric tubular-absorber compound parabolic concentrating solar collectors. Renewable Energy 1999, 18:277-281.
    • (1999) Renewable Energy , vol.18 , pp. 277-281
    • Kothdiwala, A.F.1    Eames, P.C.2    Norton, B.3    Zacharopolous, A.4
  • 13
    • 33748230239 scopus 로고    scopus 로고
    • Assessment of the Partial Model Stability of the Quasi-Dynamic Collector Test under Outdoor Conditions EN 12975 by the Application of Uncertainty Analysis. In: International Solar Energy Conference, Orlando, USA.
    • Kratzenberg, M.G., Beyer, H.G., Colle, S., Albertazzi, A., Güths, S., Fernandes, D., Oikawa, P.M.V., Machado, R.H., Petzoldt, D., 2005. Assessment of the Partial Model Stability of the Quasi-Dynamic Collector Test under Outdoor Conditions EN 12975 by the Application of Uncertainty Analysis. In: International Solar Energy Conference, Orlando, USA.
    • (2005)
    • Kratzenberg, M.G.1    Beyer, H.G.2    Colle, S.3    Albertazzi, A.4    Güths, S.5    Fernandes, D.6    Oikawa, P.M.V.7    Machado, R.H.8    Petzoldt, D.9
  • 14
    • 33750716036 scopus 로고    scopus 로고
    • Uncertainty calculation applied to different regression methods in the quasi-dynamic collector test
    • Kratzenberg M.G., Beyer H.G., Colle S. Uncertainty calculation applied to different regression methods in the quasi-dynamic collector test. Solar Energy 2006, 80:1453-1460.
    • (2006) Solar Energy , vol.80 , pp. 1453-1460
    • Kratzenberg, M.G.1    Beyer, H.G.2    Colle, S.3
  • 15
    • 50549219954 scopus 로고
    • The long-term average performance of flat-plate solar energy collectors
    • Liu B.Y.H., Jordan R.C. The long-term average performance of flat-plate solar energy collectors. Solar Energy 1963, 7.
    • (1963) Solar Energy , vol.7
    • Liu, B.Y.H.1    Jordan, R.C.2
  • 16
    • 77954311127 scopus 로고
    • User's Manual TMY2s - Typical Meteorological Year, National Renewable Energy Laboratory, Golden, CO, USA, 1995.
    • Marion, W., Urban, K., 1995. User's Manual TMY2s - Typical Meteorological Year, National Renewable Energy Laboratory, Golden, CO, USA, 1995.
    • (1995)
    • Marion, W.1    Urban, K.2
  • 17
    • 0033177722 scopus 로고    scopus 로고
    • Assessment of uncertainty in solar collector modelling and testing
    • Mathioulakis E., Voropoulos K., Belessiotis V. Assessment of uncertainty in solar collector modelling and testing. Solar Energy 1999, 66:337-347.
    • (1999) Solar Energy , vol.66 , pp. 337-347
    • Mathioulakis, E.1    Voropoulos, K.2    Belessiotis, V.3
  • 18
    • 0031126507 scopus 로고    scopus 로고
    • An improved dynamic solar collector test method for determination of non-linear optical and thermal characteristics with multiple regression
    • Perers B. An improved dynamic solar collector test method for determination of non-linear optical and thermal characteristics with multiple regression. Solar Energy 1997, 59:163-178.
    • (1997) Solar Energy , vol.59 , pp. 163-178
    • Perers, B.1
  • 20
    • 77954312943 scopus 로고
    • Analytical model for the input/output energy relationship. Commission of the European Communities.
    • Perers, B., Zinko, H., Holst, P., 1984. Analytical model for the input/output energy relationship. Commission of the European Communities.
    • (1984)
    • Perers, B.1    Zinko, H.2    Holst, P.3
  • 22
    • 45549106526 scopus 로고    scopus 로고
    • Thermal performance testing of flat-plate collectors
    • Rojas D., Beermann J., Klein S.A., Reindl D.T. Thermal performance testing of flat-plate collectors. Solar Energy 2008, 82:746-757.
    • (2008) Solar Energy , vol.82 , pp. 746-757
    • Rojas, D.1    Beermann, J.2    Klein, S.A.3    Reindl, D.T.4
  • 23
    • 0031124192 scopus 로고    scopus 로고
    • On the factorisation of incidence angle modifiers for CPC collectors
    • Rönnelid M., Perers B., Karlsson B. On the factorisation of incidence angle modifiers for CPC collectors. Solar Energy 1997, 59:281-286.
    • (1997) Solar Energy , vol.59 , pp. 281-286
    • Rönnelid, M.1    Perers, B.2    Karlsson, B.3
  • 24
    • 0036832875 scopus 로고    scopus 로고
    • Efficiency test of solar collectors: uncertainty in the estimation of regression parameters and sensitivity analysis
    • Sabatelli V., Marano D., Braccio G., Sharma V.K. Efficiency test of solar collectors: uncertainty in the estimation of regression parameters and sensitivity analysis. Energy Conversion and Management 2002, 43:2287-2295.
    • (2002) Energy Conversion and Management , vol.43 , pp. 2287-2295
    • Sabatelli, V.1    Marano, D.2    Braccio, G.3    Sharma, V.K.4
  • 25
    • 0021294995 scopus 로고
    • Performance comparison of flat plate and evacuated tubular collectors used in the Sydney University solar cooling and heating project. In: Biennial Congress of Int. Solar Energy Society Perth.
    • Schmid, R., Collins, R.E., Mannik, E., 1984. Performance comparison of flat plate and evacuated tubular collectors used in the Sydney University solar cooling and heating project. In: Biennial Congress of Int. Solar Energy Society Perth, vol. 2, pp. 1056-1060.
    • (1984) , vol.2 , pp. 1056-1060
    • Schmid, R.1    Collins, R.E.2    Mannik, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.