메뉴 건너뛰기




Volumn 217, Issue , 2012, Pages 10-18

The design of a double-tuned two-port surface resonator and its application to in vivo Hydrogen- and Sodium-MRI

Author keywords

23Na MRI; Coil construction; Double tuning; Two port surface resonator

Indexed keywords

23NA-MRI; APPARENT DIFFUSION COEFFICIENT MAPS; COIL DESIGNS; CONSTRUCTION STEPS; DATA SETS; DESIGN AND CONSTRUCTION; DETECTOR ELEMENTS; DOUBLE-TUNING; FIELD STRENGTHS; FREQUENCY COMPONENTS; FREQUENCY SIGNALS; FUNCTION OF TIME; IN-SITU; IN-VIVO; MRI SCANNERS; OPTIMAL VARIABLES; OUTPUT CHANNELS; RAT BRAIN; REGIONAL VARIATION; RODENT BRAIN; TIME COURSE;

EID: 84859430559     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2012.02.002     Document Type: Article
Times cited : (19)

References (34)
  • 1
    • 33645092692 scopus 로고    scopus 로고
    • Stroke onset time using sodium MRI in rat focal cerebral ischemia
    • DOI 10.1161/01.STR.0000198845.79254.0f, PII 0000767020060300000036
    • S.C. Jones, A. Kharlamov, B. Yanovski, D.K. Kim, K.A. Easley, V.E. Yushmanov, S.K. Ziolko, and F.E. Boada Stroke onset time using sodium MRI in rat focal cerebral ischemia Stroke 37 Mar 2006 883 888 (Pubitemid 43731926)
    • (2006) Stroke , vol.37 , Issue.3 , pp. 883-888
    • Jones, S.C.1    Kharlamov, A.2    Yanovski, B.3    Kim, D.K.4    Easley, K.A.5    Yushmanov, V.E.6    Ziolko, S.K.7    Boada, F.E.8
  • 3
    • 1342343892 scopus 로고    scopus 로고
    • Functional sodium magnetic resonance imaging of the intact rat kidney
    • DOI 10.1111/j.1523-1755.2004.00475.x
    • N. Maril, R. Margalit, J. Mispelter, and H. Degani Functional sodium magnetic resonance imaging of the intact rat kidney Kidney Int. 65 March 2004 927 935 (Pubitemid 38251068)
    • (2004) Kidney International , vol.65 , Issue.3 , pp. 927-935
    • Maril, N.1    Margalit, R.2    Mispelter, J.3    Degani, H.4
  • 4
    • 84856878359 scopus 로고    scopus 로고
    • Regional and temporal variations in tissue sodium concentration during the acute stroke phase
    • MARCH
    • F. Wetterling, L. Gallagher, I. Macrae, S. Junge, and A. Fagan Regional and temporal variations in tissue sodium concentration during the acute stroke phase Magn. Reson. Med. 67 March 2012 740 749
    • (2012) Magn. Reson. Med. , vol.67 , pp. 740-749
    • Wetterling, F.1    Gallagher, L.2    MacRae, I.3    Junge, S.4    Fagan, A.5
  • 6
    • 0033042575 scopus 로고    scopus 로고
    • Quantitative tissue sodium concentration mapping of the growth of focal cerebral tumors with sodium magnetic resonance imaging
    • DOI 10.1002/(SICI)1522-2594(199902)41:2<351::AID-MRM20>3.0.CO;2-H
    • K.R. Thulborn, D. Davis, H. Adams, T. Gindin, and J. Zhou Quantitative tissue sodium concentration mapping of the growth of focal cerebral tumors with sodium magnetic resonance imaging Magn. Reson. Med. 41 February 1999 351 359 (Pubitemid 29104522)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.2 , pp. 351-359
    • Thulborn, K.R.1    Davis, D.2    Adams, H.3    Gindin, T.4    Zhou, J.5
  • 7
    • 29144452878 scopus 로고    scopus 로고
    • Sodium MR Imaging of Acute and Subacute Stroke for Assessment of Tissue Viability
    • DOI 10.1016/j.nic.2005.08.003, PII S1052514905000535, Stroke II: Imaging Techniques and Future Directions
    • K.R. Thulborn, D. Davis, J. Snyder, H. Yonas, and A. Kassam Sodium MR imaging of acute and subacute stroke for assessment of tissue viability Neuroimag. Clin North Am 15 August 2005 639 653 xi-xii (Pubitemid 41796944)
    • (2005) Neuroimaging Clinics of North America , vol.15 , Issue.3 , pp. 639-653
    • Thulborn, K.R.1    Davis, D.2    Snyder, J.3    Yonas, H.4    Kassam, A.5
  • 8
    • 0032887073 scopus 로고    scopus 로고
    • Comprehensive MR imaging protocol for stroke management: Tissue sodium concentration as a measure of tissue viability in nonhuman primate studies and in clinical studies
    • K.R. Thulborn, T.S. Gindin, D. Davis, and P. Erb Comprehensive MR imaging protocol for stroke management: tissue sodium concentration as a measure of tissue viability in nonhuman primate studies and in clinical studies Radiology 213 October 1999 156 166 (Pubitemid 29470422)
    • (1999) Radiology , vol.213 , Issue.1 , pp. 156-166
    • Thulborn, K.R.1    Gindin, T.S.2    Davis, D.3    Erb, P.4
  • 12
    • 33751353597 scopus 로고    scopus 로고
    • 1ρ MRI for molecular and diagnostic imaging of articular cartilage
    • DOI 10.1002/nbm.1102
    • A. Borthakur, E. Mellon, S. Niyogi, W. Witschey, J.B. Kneeland, and R. Reddy Sodium and T-1 rho MRI for molecular and diagnostic imaging of articular cartilage NMR Biomed. 19 November 2006 781 821 (Pubitemid 44811543)
    • (2006) NMR in Biomedicine , vol.19 , Issue.7 , pp. 781-821
    • Borthakur, A.1    Mellon, E.2    Niyogi, S.3    Witschey, W.4    Kneeland, J.B.5    Reddy, R.6
  • 13
    • 77950278295 scopus 로고    scopus 로고
    • Brain tissue sodium concentration in multiple sclerosis: A sodium imaging study at 3 tesla
    • MARCH
    • M. Inglese, G. Madelin, N. Oesingmann, J.S. Babb, W. Wu, B. Stoeckel, J. Herbert, and G. Johnson Brain tissue sodium concentration in multiple sclerosis: a sodium imaging study at 3 tesla Brain 133 March 2010 847 857
    • (2010) Brain , vol.133 , pp. 847-857
    • Inglese, M.1    Madelin, G.2    Oesingmann, N.3    Babb, J.S.4    Wu, W.5    Stoeckel, B.6    Herbert, J.7    Johnson, G.8
  • 16
    • 78650081438 scopus 로고    scopus 로고
    • A double-tuned H-1/Na-23 dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI
    • DECEMBER 21
    • F. Wetterling, M. Tabbert, S. Junge, L. Gallagher, I.M. Macrae, and A.J. Fagan A double-tuned H-1/Na-23 dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI Phys. Med. Biol. 55 December 21 2010 7681 7695
    • (2010) Phys. Med. Biol. , vol.55 , pp. 7681-7695
    • Wetterling, F.1    Tabbert, M.2    Junge, S.3    Gallagher, L.4    MacRae, I.M.5    Fagan, A.J.6
  • 21
    • 0030671545 scopus 로고    scopus 로고
    • 1 pattern for sodium and proton imaging of the human brain at 1.5 T
    • DOI 10.1002/mrm.1910380507
    • G.X. Shen, F.E. Boada, and K.R. Thulborn Dual-frequency, dual-quadrature, birdcage RF coil design with identical B1 pattern for sodium and proton imaging of the human brain at 1.5 T Magn. Reson. Med. 38 November 1997 717 725 (Pubitemid 27467710)
    • (1997) Magnetic Resonance in Medicine , vol.38 , Issue.5 , pp. 717-725
    • Shen, G.X.1    Boada, F.E.2    Thulborn, K.R.3
  • 22
    • 51349152031 scopus 로고    scopus 로고
    • A new dedicated double-tuned (100 MHz-27 MHz) volume RF coil actively-decoupled form a receive-only simple-tuned (27 MHz) coil: Application to the MRF experiments of hyperpolarized Xe-129 in the rat brain
    • A. Asfour, and V. Auboiroux A new dedicated double-tuned (100 MHz-27 MHz) volume RF coil actively-decoupled form a receive-only simple-tuned (27 MHz) coil: application to the MRF experiments of hyperpolarized Xe-129 in the rat brain 2008 Ieee Instrum. Measur. Technol. Conf. 1-5 2008 945 950
    • (2008) 2008 Ieee Instrum. Measur. Technol. Conf. , vol.15 , pp. 945-950
    • Asfour, A.1    Auboiroux, V.2
  • 23
    • 0023618309 scopus 로고
    • A transformer-coupled double-resonant probe for NMR imaging and spectroscopy
    • DOI 10.1002/mrm.1910050510
    • J.R. Fitzsimmons, H.R. Brooker, and B. Beck A transformer-coupled double-resonant probe for Nmr imaging and spectroscopy Magn. Reson. Med. 5 November 1987 471 477 (Pubitemid 17167638)
    • (1987) Magnetic Resonance in Medicine , vol.5 , Issue.5 , pp. 471-477
    • Fitzsimmons, J.R.1    Brooker, H.R.2    Beck, B.3
  • 28
    • 0035072464 scopus 로고    scopus 로고
    • 23Na MRI after transient focal cerebral ischemia
    • S.P. Lin, S.K. Song, J.P. Miller, J.J. Ackerman, and J.J. Neil Direct, longitudinal comparison of (1)H and (23)Na MRI after transient focal cerebral ischemia Stroke 32 April 2001 925 932 (Pubitemid 32285162)
    • (2001) Stroke , vol.32 , Issue.4 , pp. 925-932
    • Lin, S.-P.1    Song, S.-K.2    Miller, J.P.3    Ackerman, J.J.H.4    Neil, J.J.5
  • 29
    • 0031022460 scopus 로고    scopus 로고
    • The sensitivity of low flip angle RARE imaging
    • DOI 10.1002/mrm.1910370206
    • D.C. Alsop The sensitivity of low flip angle RARE imaging Magn. Reson. Med. 37 February 1997 176 184 (Pubitemid 27045388)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.2 , pp. 176-184
    • Alsop, D.C.1
  • 30
    • 22744437068 scopus 로고    scopus 로고
    • Efficiency of inversion pulses for background suppressed arterial spin labeling
    • DOI 10.1002/mrm.20556
    • D.M. Garcia, G. Duhamel, and D.C. Alsop Efficiency of inversion pulses for background suppressed arterial spin labeling Magn. Reson. Med. 54 August 2005 366 372 (Pubitemid 41033553)
    • (2005) Magnetic Resonance in Medicine , vol.54 , Issue.2 , pp. 366-372
    • Garcia, D.M.1    Duhamel, G.2    Alsop, D.C.3
  • 32
  • 33
    • 68049094031 scopus 로고    scopus 로고
    • In vivo K-39, Na-23 and H-1 MR imaging using a triple resonant RF coil setup
    • SEPTEMBER
    • M. Augath, P. Heiler, S. Kirsch, and L.R. Schad In vivo K-39, Na-23 and H-1 MR imaging using a triple resonant RF coil setup J. Magn. Reson. 200 September 2009 134 136
    • (2009) J. Magn. Reson. , vol.200 , pp. 134-136
    • Augath, M.1    Heiler, P.2    Kirsch, S.3    Schad, L.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.