메뉴 건너뛰기




Volumn , Issue , 2008, Pages 945-950

A new dedicated double-tuned (100 MHz-27 MHz) volume RF coil actively-decoupled form a receive-only simple-tuned (27 MHz) coil: Application to the MRI experiments of hyperpolarized 129Xe in the rat brain

Author keywords

Active decoupling; Hyperpolarized xenon 129; MRI; RF double tuned coils

Indexed keywords

ACTIVE DECOUPLING; HYPERPOLARIZED XENON-129; MEASUREMENT TECHNOLOGIES; MRI; RF DOUBLE-TUNED COILS;

EID: 51349152031     PISSN: 10915281     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2008.4547172     Document Type: Conference Paper
Times cited : (2)

References (13)
  • 1
    • 1842428976 scopus 로고    scopus 로고
    • 129Xe in human brain analyzed by an uptake model
    • 129Xe in human brain analyzed by an uptake model". Magnetic Resonance in Medicine (MRM), 51: 843-847,2004.
    • (2004) Magnetic Resonance in Medicine (MRM) , vol.51 , pp. 843-847
    • Kilian, W.1
  • 4
    • 0036333672 scopus 로고    scopus 로고
    • Global and regional cerebral blood flow measurements using NMR of injected hyperpolarized xenon-129
    • G. Duhamel et al., "Global and regional cerebral blood flow measurements using NMR of injected hyperpolarized xenon-129. Acad Radiol., 9(2): 498-500; 2002.
    • (2002) Acad Radiol , vol.9 , Issue.2 , pp. 498-500
    • Duhamel, G.1
  • 5
    • 34648838017 scopus 로고    scopus 로고
    • Development of a fully digital and low frequency NMR system for polarization measurement of hyperpolarized gases
    • Sorrento-Italy, April 20-23
    • A. Asfour et al., "Development of a fully digital and low frequency NMR system for polarization measurement of hyperpolarized gases", Proceedings of the IEEE Instrumentation and Measurement Technology Conference IMTC 2006, Sorrento-Italy, April 20-23, 2006.
    • (2006) Proceedings of the IEEE Instrumentation and Measurement Technology Conference IMTC
    • Asfour, A.1
  • 6
    • 46549092488 scopus 로고
    • An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5 T
    • C. E. Hayes et al., "An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5 T", Journal of Magnetic Resonance, 63: 622-628; 1985.
    • (1985) Journal of Magnetic Resonance , vol.63 , pp. 622-628
    • Hayes, C.E.1
  • 7
    • 51349115304 scopus 로고    scopus 로고
    • J. Mispelter, M. Lupu and A. Briguet, NMR Probeheads for Biophysical and Biomedical Experiments: theoretical principles and practical guidelines. Imperial College Press, 2006.
    • J. Mispelter, M. Lupu and A. Briguet, NMR Probeheads for Biophysical and Biomedical Experiments: theoretical principles and practical guidelines. Imperial College Press, 2006.
  • 8
    • 0009569536 scopus 로고
    • Design and performance of a double-tuned birdcage coil
    • A. R. Rath, "Design and performance of a double-tuned birdcage coil", Journal of Magnetic Resonance, 86: 488-495; 1990.
    • (1990) Journal of Magnetic Resonance , vol.86 , pp. 488-495
    • Rath, A.R.1
  • 10
    • 18444401717 scopus 로고    scopus 로고
    • BirdcageBuilder: Design of specified-geometry birdcage coils with desired current pattern and reonance frequency
    • C. L. Chin et al., "BirdcageBuilder: Design of specified-geometry birdcage coils with desired current pattern and reonance frequency", Concepts in Magnetic Resonance, 15(2): 156-163, 2002.
    • (2002) Concepts in Magnetic Resonance , vol.15 , Issue.2 , pp. 156-163
    • Chin, C.L.1
  • 11
    • 0037851009 scopus 로고    scopus 로고
    • A coil combination for magnetic resonance perfusion imaging of mice in vivo at 7 T
    • J. U. G. Streif et al. "A coil combination for magnetic resonance perfusion imaging of mice in vivo at 7 T", Review of Scientific Instruments, 74 (5): 2843-2848, 2003.
    • (2003) Review of Scientific Instruments , vol.74 , Issue.5 , pp. 2843-2848
    • Streif, J.U.G.1
  • 12
    • 0033959514 scopus 로고    scopus 로고
    • A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
    • E. A. Barberi et al. "A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications,"Magnetic Resonance in Medicine (MRM), 43: 284-289, 2000.
    • (2000) Magnetic Resonance in Medicine (MRM) , vol.43 , pp. 284-289
    • Barberi, E.A.1
  • 13
    • 0002904010 scopus 로고
    • An inductively coupled, series tuned NMR probe gases
    • M. Décorps et al., "An inductively coupled, series tuned NMR probe gases", Journal of Magnetic Resonance, 65: 100-109; 1985.
    • (1985) Journal of Magnetic Resonance , vol.65 , pp. 100-109
    • Décorps, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.