메뉴 건너뛰기




Volumn 57, Issue 8, 2012, Pages 2209-2217

Investigation of signal fading in lithium formate EPR dosimeters using a new sensitive method

Author keywords

[No Author keywords available]

Indexed keywords

AIR HUMIDITY; CLINICAL APPLICATION; CLINICAL AUDIT; CONSTANT LEVEL; EPR SIGNALS; NEW EXPERIMENTAL METHOD; SENSITIVE METHOD; SIGNAL FADING; STORAGE TEMPERATURES; TRANSFER DOSIMETRY;

EID: 84859345008     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/8/2209     Document Type: Article
Times cited : (15)

References (15)
  • 1
    • 77956329689 scopus 로고    scopus 로고
    • Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy
    • Adolfsson E, Alm Carlsson G, Grindborg J-E, Gustafsson H, Lund E and Carlsson Tedgren Å 2010 Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy Med. Phys. 37 494659
    • (2010) Med. Phys. , vol.37 , Issue.9 , pp. 4946-4959
    • Adolfsson, E.1    Alm Carlsson, G.2    Grindborg, J.-E.3    Gustafsson, H.4    Lund, E.5    Tedgren Å, C.6
  • 2
    • 14844290219 scopus 로고    scopus 로고
    • Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system
    • DOI 10.1016/j.apradiso.2004.10.009, PII S0969804304005512
    • Anton M 2005 Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system Appl. Radiat. Isot. 62 77995 (Pubitemid 40342988)
    • (2005) Applied Radiation and Isotopes , vol.62 , Issue.5 , pp. 779-795
    • Anton, M.1
  • 6
    • 51849102925 scopus 로고    scopus 로고
    • Lithium formate EPR dosimetry for verification of calculated dose distributions prior to intensity modulated radiation therapy
    • Gustafsson H, Lund E and Olsson S 2008 Lithium formate EPR dosimetry for verification of calculated dose distributions prior to intensity modulated radiation therapy Phys. Med. Biol. 53 466782
    • (2008) Phys. Med. Biol. , vol.53 , Issue.17 , pp. 4667-4682
    • Gustafsson, H.1    Lund, E.2    Olsson, S.3
  • 9
    • 0033955780 scopus 로고    scopus 로고
    • The IAEA/WHO TLD postal programme for radiotherapy hospitals
    • DOI 10.1016/S0167-8140(99)00164-4, PII S0167814099001644
    • Izewska J and Andreo P 2000 The IAEA/WHO TLD postal programme for radiotherapy hospitals Radiother. Oncol. 54 6572 (Pubitemid 30055327)
    • (2000) Radiotherapy and Oncology , vol.54 , Issue.1 , pp. 65-72
    • Izewska, J.1    Andreo, P.2
  • 11
    • 0033991649 scopus 로고    scopus 로고
    • Advancements in accuracy of the alanine dosimetry system: Part 2. The influence of the irradiation temperature
    • Nagy V, Puhl J and Desrosiers M 2000a Advancements in accuracy of the alanine dosimetry system: part 2. The influence of the irradiation temperature Radiat. Phys. Chem. 57 19
    • (2000) Radiat. Phys. Chem. , vol.57 , Issue.1 , pp. 1-9
    • Nagy, V.1    Puhl, J.2    Desrosiers, M.3
  • 12
    • 0034308239 scopus 로고    scopus 로고
    • Advancements in accuracy of the alanine EPR dosimetry system. Part III: Usefulness of an adjacent reference sample
    • DOI 10.1016/S0969-806X(00)00275-9, PII S0969806X00002759
    • Nagy V, Sleptchonok O F, Desrosiers M F, Weber R T and Heiss A H 2000b Advancements in accuracy of the alanine EPR dosimetry system: part III. Usefulness of an adjacent reference sample Radiat. Phys. Chem. 59 42941 (Pubitemid 30616438)
    • (2000) Radiation Physics and Chemistry , vol.59 , Issue.4 , pp. 429-441
    • Nagy, V.1    Sleptchonok, O.F.2    Desrosiers, M.F.3    Weber, R.T.4    Heiss, A.H.5
  • 13
    • 0033622850 scopus 로고    scopus 로고
    • Advancements in accuracy of the alanine dosimetry system: Part 1. The effects of environmental humidity
    • Sleptchonok O, Nagy V and Desrosiers M 2000 Advancements in accuracy of the alanine dosimetry system: part 1. The effects of environmental humidity Radiat. Phys. Chem. 57 11533
    • (2000) Radiat. Phys. Chem. , vol.57 , Issue.2 , pp. 115-133
    • Sleptchonok, O.1    Nagy, V.2    Desrosiers, M.3
  • 15
    • 7244245568 scopus 로고    scopus 로고
    • Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: Comparison with thermoluminescence (TL) dosimetry using lithium fluoride rods
    • DOI 10.1088/0031-9155/49/20/003, PII S0031915504831221
    • Vestad T A, Malinen E, Olsen D R, Hole E O and Sagstuen E 2004 Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: comparison with thermoluminescence (TL) dosimetry using lithium flouride rods Phys. Med. Biol. 40 470115 (Pubitemid 39433500)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.20 , pp. 4701-4715
    • Vestad, T.A.1    Malinen, E.2    Olsen, D.R.3    Hole, E.O.4    Sagstuen, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.