-
1
-
-
34247616143
-
In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillator detector
-
0094-2405,. 10.1118/1.2727248
-
J. Lambert, T. Nakano, S. Law, J. Elsey, D. R. McKenzie, and N. Suchowerska, " In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillator detector.," Med. Phys. 0094-2405 34, 1759-1765 (2007). 10.1118/1.2727248
-
(2007)
Med. Phys.
, vol.34
, pp. 1759-1765
-
-
Lambert, J.1
Nakano, T.2
Law, S.3
Elsey, J.4
McKenzie, D.R.5
Suchowerska, N.6
-
2
-
-
34447301820
-
Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors
-
0094-2405,. 10.1118/1.2736288
-
Z. Qi, X. Deng, S. Huang, J. Lu, M. Lerch, D. Cutajar, and A. Rosenfeld, " Verification of the plan dosimetry for high dose rate brachytherapy using metal-oxide-semiconductor field effect transistor detectors.," Med. Phys. 0094-2405 34, 2007-2013 (2007). 10.1118/1.2736288
-
(2007)
Med. Phys.
, vol.34
, pp. 2007-2013
-
-
Qi, Z.1
Deng, X.2
Huang, S.3
Lu, J.4
Lerch, M.5
Cutajar, D.6
Rosenfeld, A.7
-
3
-
-
1142304255
-
Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
-
0094-2405,. 10.1118/1.1646040
-
M. J. Rivard, B. M. Coursey, L. A. DeWerd, W. F. Hanson, M. S. Huq, G. S. Ibbott, M. G. Mitch, R. Nath, and J. F. Williamson, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 0094-2405 31, 633-674 (2004). 10.1118/1.1646040
-
(2004)
Med. Phys.
, vol.31
, pp. 633-674
-
-
Rivard, M.J.1
Coursey, B.M.2
Dewerd, L.A.3
Hanson, W.F.4
Huq, M.S.5
Ibbott, G.S.6
Mitch, M.G.7
Nath, R.8
Williamson, J.F.9
-
4
-
-
33845939280
-
Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 keV
-
0094-2405,. 10.1118/1.2388155
-
Z. Li, R. K. Das, L. A. DeWerd, G. S. Ibbott, A. S. Meigooni, J. Ṕrez-Calatayud, M. J. Rivard, R. S. Sloboda, and J. F. Williamson, " Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 keV.," Med. Phys. 0094-2405 34, 37-40 (2007). 10.1118/1.2388155
-
(2007)
Med. Phys.
, vol.34
, pp. 37-40
-
-
Li, Z.1
Das, R.K.2
Dewerd, L.A.3
Ibbott, G.S.4
Meigooni, A.S.5
Ṕrez- Calatayud, J.6
Rivard, M.J.7
Sloboda, R.S.8
Williamson, J.F.9
-
5
-
-
0000116668
-
Dosimetry of palladium-103 brachytherapy sources for permanent implants
-
A. S. Meigooni, S. Sabnis, and R. Nath, " Dosimetry of palladium-103 brachytherapy sources for permanent implants.," Endocurie Hypertherm Oncol. 6, 107-117 (1990).
-
(1990)
Endocurie Hypertherm Oncol.
, vol.6
, pp. 107-117
-
-
Meigooni, A.S.1
Sabnis, S.2
Nath, R.3
-
6
-
-
0025922324
-
Thermoluminescent dosimetry for P 103 d seeds (model 200) in solid water phantom
-
0094-2405,. 10.1118/1.596692
-
S. -T. Chiu-Tsao and L. L. Anderson, " Thermoluminescent dosimetry for P 103 d seeds (model 200) in solid water phantom.," Med. Phys. 0094-2405 18, 449-452 (1991). 10.1118/1.596692
-
(1991)
Med. Phys.
, vol.18
, pp. 449-452
-
-
Chiu-Tsao, S.-T.1
Anderson, L.L.2
-
7
-
-
0027786947
-
Anisotropy functions for P 103 d, i 125 and i 192 r interstitial brachytherapy sources
-
0094-2405,. 10.1118/1.597110
-
R. Nath, A. S. Meigooni, P. Muench, and A. Melillo, " Anisotropy functions for P 103 d, I 125 and I 192 r interstitial brachytherapy sources.," Med. Phys. 0094-2405 20, 1465-1473 (1993). 10.1118/1.597110
-
(1993)
Med. Phys.
, vol.20
, pp. 1465-1473
-
-
Nath, R.1
Meigooni, A.S.2
Muench, P.3
Melillo, A.4
-
8
-
-
0014786851
-
Proton dosimetry: Measurement of depth doses from 185-MeV protons by means of thermoluminescent LiF
-
0033-7587,. 10.2307/3572792
-
C. A. Carlsson and G. Alm Carlsson, " Proton dosimetry: Measurement of depth doses from 185-MeV protons by means of thermoluminescent LiF.," Radiat. Res. 0033-7587 42, 207-219 (1970). 10.2307/3572792
-
(1970)
Radiat. Res.
, vol.42
, pp. 207-219
-
-
Carlsson, C.A.1
Alm Carlsson, G.2
-
9
-
-
42949161466
-
LiF: Mg, Ti TLD response as a function of photon energy for moderated filtered x-ray spectra in the range 20-250 kVP relative to C 60 o
-
0094-2405,. 10.1118/1.2898137
-
A. A. Nunn, S. D. Davis, J. A. Micka, and L. A. De Werd, " LiF: Mg, Ti TLD response as a function of photon energy for moderated filtered x-ray spectra in the range 20-250 kVP relative to C 60 o.," Med. Phys. 0094-2405 35, 1859-1869 (2008). 10.1118/1.2898137
-
(2008)
Med. Phys.
, vol.35
, pp. 1859-1869
-
-
Nunn, A.A.1
Davis, S.D.2
Micka, J.A.3
De Werd, L.A.4
-
10
-
-
0029563617
-
TLD, diode and Monte Carlo dosimetry of an i 192 r source for high dose-rate brachytherapy
-
0031-9155,. 10.1088/0031-9155/40/12/002
-
A. S. Kirov, J. F. Williamson, A. S. Meigooni, and Y. Zhu, " TLD, diode and Monte Carlo dosimetry of an I 192 r source for high dose-rate brachytherapy.," Phys. Med. Biol. 0031-9155 40, 2015-2036 (1995). 10.1088/0031-9155/40/12/002
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 2015-2036
-
-
Kirov, A.S.1
Williamson, J.F.2
Meigooni, A.S.3
Zhu, Y.4
-
11
-
-
0037149982
-
Radiation dose measurements with alanine/agarose gel and thin alanine films around a i 192 r brachytherapy source, using ESR spectroscopy
-
0031-9155,. 10.1088/0031-9155/47/8/308
-
S. K. Olsson, E. S. Bergstrand, Å. K. Carlsson, E. O. Hole, and E. Lund, " Radiation dose measurements with alanine/agarose gel and thin alanine films around a I 192 r brachytherapy source, using ESR spectroscopy.," Phys. Med. Biol. 0031-9155 47, 1333-1356 (2002). 10.1088/0031-9155/47/8/308
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 1333-1356
-
-
Olsson, S.K.1
Bergstrand, E.S.2
Carlsson, Å.K.3
Hole, E.O.4
Lund, E.5
-
12
-
-
16444387482
-
Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry
-
0031-9155,. 10.1088/0031-9155/50/6/005
-
C. S. G. Calcina, A. De Almeida, J. R. Oliveira Rocha, F. Chen Abrego, and O. Baffa, " Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry.," Phys. Med. Biol. 0031-9155 50, 1109-1117 (2005). 10.1088/0031-9155/50/6/005
-
(2005)
Phys. Med. Biol.
, vol.50
, pp. 1109-1117
-
-
Calcina, C.S.G.1
De Almeida, A.2
Oliveira Rocha, J.R.3
Chen Abrego, F.4
Baffa, O.5
-
13
-
-
0037605852
-
In vivo alanine/EPR dosimetry in daily clinical practice: A feasibility study
-
0360-3016,. 10.1016/S0360-3016(03)00196-2
-
B. Ciesielski, K. Schultka, A. Kobierska, R. Nowak, and Z. Peimel-Stuglik, " In vivo alanine/EPR dosimetry in daily clinical practice: A feasibility study.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 56, 899-905 (2003). 10.1016/S0360-3016(03)00196-2
-
(2003)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.56
, pp. 899-905
-
-
Ciesielski, B.1
Schultka, K.2
Kobierska, A.3
Nowak, R.4
Peimel-Stuglik, Z.5
-
14
-
-
0020331280
-
Dosimetry by ESR spectroscopy of alanine
-
0969-8043,. 10.1016/0020-708X(82)90238-1
-
D. F. Regulla and U. Deffner, " Dosimetry by ESR spectroscopy of alanine.," Appl. Radiat. Isot. 0969-8043 33, 1101-1114 (1982). 10.1016/0020-708X(82)90238-1
-
(1982)
Appl. Radiat. Isot.
, vol.33
, pp. 1101-1114
-
-
Regulla, D.F.1
Deffner, U.2
-
15
-
-
0035126054
-
Transit dose of an Ir-192 high dose rate brachytherapy stepping source
-
0031-9155,. 10.1088/0031-9155/46/2/304
-
T. P. Y. Wong, W. Fernando, P. N. Johnston, and I. F. Bubb, " Transit dose of an Ir-192 high dose rate brachytherapy stepping source.," Phys. Med. Biol. 0031-9155 46, 323-331 (2001). 10.1088/0031-9155/46/2/304
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 323-331
-
-
Wong, T.P.Y.1
Fernando, W.2
Johnston, P.N.3
Bubb, I.F.4
-
16
-
-
0027304238
-
The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications
-
K. T. Bastin, M. B. Podgorsak, and B. R. Thomadsen, " Transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 26, 695-702 (1993). (Pubitemid 23220172)
-
(1993)
International Journal of Radiation Oncology Biology Physics
, vol.26
, Issue.4
, pp. 695-702
-
-
Bastin, K.T.1
Podgorsak, M.B.2
Thomadsen, B.R.3
-
17
-
-
0026447630
-
Dose determination in high dose rate brachytherapy
-
0360-3016.
-
P. V. Houdek, J. G. Schwade, X. Wu, V. Pisciotta, J. A. Fiedler, C. F. Serago, A. M. Markoe, A. A. Abitbol, A. A. Lewin, P. G. Braunschweiger, and M. D. Sklar, " Dose determination in high dose rate brachytherapy.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 24, 795-801 (1992).
-
(1992)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.24
, pp. 795-801
-
-
Houdek, P.V.1
Schwade, J.G.2
Wu, X.3
Pisciotta, V.4
Fiedler, J.A.5
Serago, C.F.6
Markoe, A.M.7
Abitbol, A.A.8
Lewin, A.A.9
Braunschweiger, P.G.10
Sklar, M.D.11
-
18
-
-
0029062568
-
Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy
-
0094-2405,. 10.1118/1.597484
-
R. K. Valicenti, A. S. Kirov, A. S. Meigooni, V. Mishra, R. K. Das, and J. F. Williamson, " Experimental validation of Monte Carlo dose calculations about a high-intensity Ir-192 source for pulsed dose-rate brachytherapy.," Med. Phys. 0094-2405 22, 821-829 (1995). 10.1118/1.597484
-
(1995)
Med. Phys.
, vol.22
, pp. 821-829
-
-
Valicenti, R.K.1
Kirov, A.S.2
Meigooni, A.S.3
Mishra, V.4
Das, R.K.5
Williamson, J.F.6
-
19
-
-
85027228921
-
-
Ph.D. thesis, Linköping University, (online, available at).
-
H. Gustafsson, Ph.D. thesis, Linköping University, 2008 (online, available at http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-11099).
-
(2008)
-
-
Gustafsson, H.1
-
20
-
-
0042020306
-
EPR dosimetric properties of formates
-
0969-8043,. 10.1016/S0969-8043(03)00165-9
-
T. A. Vestad, E. Malinen, A. Lund, E. O. Hole, and E. Sagstuen, " EPR dosimetric properties of formates.," Appl. Radiat. Isot. 0969-8043 59, 181-188 (2003). 10.1016/S0969-8043(03)00165-9
-
(2003)
Appl. Radiat. Isot.
, vol.59
, pp. 181-188
-
-
Vestad, T.A.1
Malinen, E.2
Lund, A.3
Hole, E.O.4
Sagstuen, E.5
-
21
-
-
3042821938
-
Radiation-induced radicals in lithium formate monohydrate (LiHCO2H2O). EPR and ENDOR studies of X-irradiated crystal and polycrystalline samples
-
1463-9076,. 10.1039/b402846e
-
T. A. Vestad, H. Gustafsson, A. Lund, E. O. Hole, and E. Sagstuen, " Radiation-induced radicals in lithium formate monohydrate (LiHCO2H2O). EPR and ENDOR studies of X-irradiated crystal and polycrystalline samples.," Phys. Chem. Chem. Phys. 1463-9076 6, 3017-3022 (2004). 10.1039/b402846e
-
(2004)
Phys. Chem. Chem. Phys.
, vol.6
, pp. 3017-3022
-
-
Vestad, T.A.1
Gustafsson, H.2
Lund, A.3
Hole, E.O.4
Sagstuen, E.5
-
22
-
-
7244245568
-
Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: Comparison with thermoluminescence (TL) dosimetry using lithium flouride rods
-
0031-9155,. 10.1088/0031-9155/49/20/003
-
T. A. Vestad, E. Malinen, D. R. Olsen, E. O. Hole, and E. Sagstuen, " Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: Comparison with thermoluminescence (TL) dosimetry using lithium flouride rods.," Phys. Med. Biol. 0031-9155 49, 4701-4715 (2004). 10.1088/0031-9155/49/20/003
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 4701-4715
-
-
Vestad, T.A.1
Malinen, E.2
Olsen, D.R.3
Hole, E.O.4
Sagstuen, E.5
-
23
-
-
34547321939
-
The energy dependence of lithium formate EPR dosimeters for clinical electron beams
-
0031-9155,. 10.1088/0031-9155/52/14/022
-
E. Malinen, E. Waldeland, E. O. Hole, and E. Sagstuen, " The energy dependence of lithium formate EPR dosimeters for clinical electron beams.," Phys. Med. Biol. 0031-9155 52, 4361-4369 (2007). 10.1088/0031-9155/52/14/022
-
(2007)
Phys. Med. Biol.
, vol.52
, pp. 4361-4369
-
-
Malinen, E.1
Waldeland, E.2
Hole, E.O.3
Sagstuen, E.4
-
24
-
-
51849102925
-
Lithium formate EPR dosimetry for verification of calculated dose distributions prior to intensity modulated radiation therapy
-
0031-9155,. 10.1088/0031-9155/53/17/014
-
H. Gustafsson, E. Lund, and S. Olsson, " Lithium formate EPR dosimetry for verification of calculated dose distributions prior to intensity modulated radiation therapy.," Phys. Med. Biol. 0031-9155 53, 4667-4682 (2008). 10.1088/0031-9155/53/17/014
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 4667-4682
-
-
Gustafsson, H.1
Lund, E.2
Olsson, S.3
-
25
-
-
0030293066
-
One year of experience with alanine EPR dosimetry in radiotherapy
-
0969-8043,. 10.1016/S0969-8043(96)00040-1
-
B. Schaeken and P. Scalliet, " One year of experience with alanine EPR dosimetry in radiotherapy.," Appl. Radiat. Isot. 0969-8043 47, 1177-1182 (1996). 10.1016/S0969-8043(96)00040-1
-
(1996)
Appl. Radiat. Isot.
, vol.47
, pp. 1177-1182
-
-
Schaeken, B.1
Scalliet, P.2
-
26
-
-
0003680967
-
Absorbed dose determination in external beam radiotherapy: An international code of practice based on Standards of absorbed dose to water
-
IAEA, "," (Vienna, International Atomic Energy Agency).
-
IAEA, " Absorbed dose determination in external beam radiotherapy: An international code of practice based on Standards of absorbed dose to water.," Report No. IAEA TRS 398 (Vienna, International Atomic Energy Agency, 2000).
-
(2000)
Report No. IAEA TRS 398
-
-
-
27
-
-
25644456181
-
Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols
-
0094-2405,. 10.1118/1.2012807
-
J. P. Seuntjens, M. Olivares, M. Evans, and E. Podgorsak, " Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols.," Med. Phys. 0094-2405 32, 2945-2953 (2005). 10.1118/1.2012807
-
(2005)
Med. Phys.
, vol.32
, pp. 2945-2953
-
-
Seuntjens, J.P.1
Olivares, M.2
Evans, M.3
Podgorsak, E.4
-
28
-
-
65649123553
-
Least squares when both variables have uncertainties
-
0002-9505,. 10.1119/1.12972
-
J. Orear, " Least squares when both variables have uncertainties.," Am. J. Phys. 0002-9505 50, 912-916 (1982). 10.1119/1.12972
-
(1982)
Am. J. Phys.
, vol.50
, pp. 912-916
-
-
Orear, J.1
-
29
-
-
0034657422
-
Accuracy considerations in EPR dosimetry
-
0969-8043,. 10.1016/S0969-8043(00)00052-X
-
V. Nagy, " Accuracy considerations in EPR dosimetry.," Appl. Radiat. Isot. 0969-8043 52, 1039-1050 (2000). 10.1016/S0969-8043(00)00052-X
-
(2000)
Appl. Radiat. Isot.
, vol.52
, pp. 1039-1050
-
-
Nagy, V.1
-
30
-
-
0035664767
-
Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus i 192 r sources
-
0094-2405,. 10.1118/1.1420398
-
F. Ballester, V. Puchades, J. L. Lluch, M. A. Serrano-Andŕs, Y. Limami, J. Calatayud-Ṕrez, and E. Casal, " Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus I 192 r sources.," Med. Phys. 0094-2405 28, 2586-2591 (2001). 10.1118/1.1420398
-
(2001)
Med. Phys.
, vol.28
, pp. 2586-2591
-
-
Ballester, F.1
Puchades, V.2
Lluch, J.L.3
Serrano-Andŕs, M.A.4
Limami, Y.5
Calatayud-Ṕrez, J.6
Casal, E.7
-
31
-
-
0037244209
-
Monte Carlo dosimetry of a new i 192 r pulsed dose rate brachytherapy source
-
0094-2405,. 10.1118/1.1524168
-
P. Karaiskos, A. Angelopoulos, E. Pantelis, P. Papagiannis, L. Sakelliou, E. Kouwenhoven, and D. Baltas, " Monte Carlo dosimetry of a new I 192 r pulsed dose rate brachytherapy source.," Med. Phys. 0094-2405 30, 9-16 (2003). 10.1118/1.1524168
-
(2003)
Med. Phys.
, vol.30
, pp. 9-16
-
-
Karaiskos, P.1
Angelopoulos, A.2
Pantelis, E.3
Papagiannis, P.4
Sakelliou, L.5
Kouwenhoven, E.6
Baltas, D.7
-
32
-
-
0001458835
-
-
in, edited by F. H. Attix and W. C. Roesch (Academic, New York), Vol.,.
-
T. E. Burlin, in Radiation Dosimetry, edited by, F. H. Attix, and, W. C. Roesch, (Academic, New York, 1968), Vol. 1, p. 331.
-
(1968)
Radiation Dosimetry
, vol.1
, pp. 331
-
-
Burlin, T.E.1
-
33
-
-
0003797114
-
The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport
-
In: (Ottawa:National Research Council Canada).
-
I. Kawrakow and D. W. O. Rogers, " The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport. " In: NRCC PIRS-701 (Ottawa:National Research Council Canada, 2006).
-
(2006)
NRCC PIRS-701
-
-
Kawrakow, I.1
Rogers, D.W.O.2
-
34
-
-
0003492598
-
NRC User Codes for EGSnrc
-
In: (Ottawa:National Research Council Canada).
-
D. W. O. Rogers, I. Kawrakow, J. P. Seuntjens, B. R. B. Walters, and E. Mainegra-Hing, " NRC User Codes for EGSnrc.,'' In: NRCC PIRS-702(revB) (Ottawa:National Research Council Canada, 2005).
-
(2005)
NRCC PIRS-702(revB)
-
-
Rogers, D.W.O.1
Kawrakow, I.2
Seuntjens, J.P.3
Walters, B.R.B.4
Mainegra-Hing, E.5
-
35
-
-
0021849353
-
Energy and angular distributions of photons from medical linear accelerators
-
0094-2405,. 10.1118/1.595680
-
R. Mohan, C. Chui, and L. Lidofsky, " Energy and angular distributions of photons from medical linear accelerators.," Med. Phys. 0094-2405 12, 592-597 (1985). 10.1118/1.595680
-
(1985)
Med. Phys.
, vol.12
, pp. 592-597
-
-
Mohan, R.1
Chui, C.2
Lidofsky, L.3
-
36
-
-
0003992280
-
-
(version 1.2.3), National Institute of Standards and Technology, Gaithersburg, MD,. [Online] Available: [January 23, 2009]. Originally published as, NISTIR 4999, National Institute of Standards and Technology, Gaithersburg, MD (1993).
-
M. J. Berger, J. S. Coursey, M. A. Zucker, and J. Chang, ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions (version 1.2.3), National Institute of Standards and Technology, Gaithersburg, MD, 2005. [Online] Available: http://physics.nist.gov/Star [January 23, 2009]. Originally published as M. J. Berger, NISTIR 4999, National Institute of Standards and Technology, Gaithersburg, MD (1993).
-
(2005)
ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions
-
-
Berger, M.J.1
Coursey, J.S.2
Zucker, M.A.3
Chang, J.4
Berger, M.J.5
-
37
-
-
0003523753
-
-
(version 1.4). [Online] Available: [January 23, 2009]. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD (1995).
-
J. H. Hubbell and S. M. Seltzer, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4) (2004). [Online] Available: http://physics.nist.gov/xaamdi [January 23, 2009]. National Institute of Standards and Technology, Gaithersburg, MD. Originally published as NISTIR 5632, National Institute of Standards and Technology, Gaithersburg, MD (1995).
-
(2004)
Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients
-
-
Hubbell, J.H.1
Seltzer, S.M.2
-
38
-
-
66449103523
-
Influence of phantom material and dimensions on experimental i 192 r dosimetry
-
0094-2405.
-
Å. Carlsson Tedgren and G. Alm Carlsson, " Influence of phantom material and dimensions on experimental I 192 r dosimetry.," Med. Phys. 0094-2405 36, 2228-2235 (2009).
-
(2009)
Med. Phys.
, vol.36
, pp. 2228-2235
-
-
Carlsson Tedgren, Å.1
Alm Carlsson, G.2
-
39
-
-
36649031763
-
Monte Carlo simulations of photon spectra in air from i 192 r sources
-
In: (Ottawa:National Research Council Canada).
-
J. Borg and D. W. O. Rogers, " Monte Carlo simulations of photon spectra in air from I 192 r sources.," In: NRCC PIRS-629r (Ottawa:National Research Council Canada, 1999).
-
(1999)
NRCC PIRS-629r
-
-
Borg, J.1
Rogers, D.W.O.2
-
40
-
-
54949121823
-
Equivalent phantom sizes and shapes for brachytherapy dosimetric studies of i 192 r and C 137 s
-
0094-2405,. 10.1118/1.2982140
-
D. Granero, J. Ṕrez-Calatayud, M. Pujades-Claumarchirant, F. Ballester, C. Melhus, and M. J. Rivard, " Equivalent phantom sizes and shapes for brachytherapy dosimetric studies of I 192 r and C 137 s.," Med. Phys. 0094-2405 35, 4872-4877 (2008). 10.1118/1.2982140
-
(2008)
Med. Phys.
, vol.35
, pp. 4872-4877
-
-
Granero, D.1
Ṕrez-Calatayud, J.2
Pujades-Claumarchirant, M.3
Ballester, F.4
Melhus, C.5
Rivard, M.J.6
-
41
-
-
84976821043
-
An adaptive algorithm for numerical integration over an N-dimensional rectangular region
-
0377-0427,. 10.1016/0771-050X(80)90039-X
-
A. C. Genz and A. A. Malik, " An adaptive algorithm for numerical integration over an N-dimensional rectangular region.," J. Comput. Appl. Math. 0377-0427 6, 295-302 (1980). 10.1016/0771-050X(80)90039-X
-
(1980)
J. Comput. Appl. Math.
, vol.6
, pp. 295-302
-
-
Genz, A.C.1
Malik, A.A.2
-
42
-
-
0031120968
-
ROOT-An object oriented data analysis framework, Proceedings AIHENP'96 Workshop, Lausanne, Sep. 1996
-
0168-9002,. 10.1016/S0168-9002(97)00048-X
-
R. Brun and F. Rademakers, " ROOT-An object oriented data analysis framework, Proceedings AIHENP'96 Workshop, Lausanne, Sep. 1996.," Nucl. Instrum. Methods Phys. Res. A 0168-9002 389, 81-86 (1997). 10.1016/S0168- 9002(97)00048-X
-
(1997)
Nucl. Instrum. Methods Phys. Res. A
, vol.389
, pp. 81-86
-
-
Brun, R.1
Rademakers, F.2
-
43
-
-
66449135492
-
-
International Organization for Standardization, Guide to the Expression of Uncertainties in Measurements
-
International Organization for Standardization, Guide to the Expression of Uncertainties in Measurements," 1995.
-
(1995)
-
-
-
44
-
-
33751166576
-
Uncertainties in alanine/EPR dosimetry at the Physikalisch-Technische Bundesanstalt
-
0031-9155,. 10.1088/0031-9155/51/21/003
-
M. Anton, " Uncertainties in alanine/EPR dosimetry at the Physikalisch-Technische Bundesanstalt.," Phys. Med. Biol. 0031-9155 51, 5419-5440 (2006). 10.1088/0031-9155/51/21/003
-
(2006)
Phys. Med. Biol.
, vol.51
, pp. 5419-5440
-
-
Anton, M.1
-
45
-
-
41449084989
-
Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources
-
0094-2405,. 10.1118/1.2868766
-
D. Granero, J. Ṕrez-Calatayud, and F. Ballester, " Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources.," Med. Phys. 0094-2405 35, 1280-1287 (2008). 10.1118/1.2868766
-
(2008)
Med. Phys.
, vol.35
, pp. 1280-1287
-
-
Granero, D.1
Ṕrez-Calatayud, J.2
Ballester, F.3
|