1
-
-
0028496219
-
Review ofChemical Indicators of Degradation of Cellulosic Electrical Paper Insulation in Oil-Filled transformers
-
September
-
A. M. Emsley, and G. C. Stevens, "Review ofChemical Indicators of Degradation of Cellulosic Electrical Paper Insulation in Oil-Filled transformers", IEE Proc.-Sci. Meas. Technol., Vol. 141, No. 5, pp. 324-334, September 1994.
-
(1994)
IEE Proc.-Sci. Meas. Technol.
, vol.141
, Issue.5
, pp. 324-334
-
-
Emsley, A.M.1
Stevens, G.C.2
-
2
-
-
0033732347
-
Degradation ofCellulosic Insulation in Power Transformers. Part 3: Effects on Oxygen and Water on Aging in Oil
-
May
-
A. M. Emsley, X. Xiao, R. J. Heywood, and M. Ali, "Degradation ofCellulosic Insulation in Power Transformers. Part 3: Effects on Oxygen and Water on Aging in Oil", IEE Proc-Sci. Meas. Technol., May 2000, 147, No. 3, pp. 115-119.
-
(2000)
IEE Proc-Sci. Meas. Technol.
, vol.147
, Issue.3
, pp. 115-119
-
-
Emsley, A.M.1
Xiao, X.2
Heywood, R.J.3
Ali, M.4
-
3
-
-
0034313980
-
Degradation of cellulosic insulation in power transformers. Part 4: Effects of ageing on the tensile strength of paper
-
DOI 10.1049/ip-smt:20000644
-
A.M. Emsley, R. J. Heywood, M. Ali, and X. Xiao, "Degradation ofCellulosic Insulation in Power Transformers. Part 4. Effects of Aging on the Tensile Strength of Paper", IEE Proc. Sci. Meas. Technol., May 2000, Vol. 147, No. 6, pp. 285-290. (Pubitemid 32134362)
-
(2000)
IEE Proceedings: Science, Measurement and Technology
, vol.147
, Issue.6
, pp. 285-290
-
-
Emsley, A.M.1
Heywood, R.J.2
Ali, M.3
Xiao, X.4
-
4
-
-
0033742666
-
Degradation ofcellulosic insulation in power Transformers. Part 2: Formation of furan products in insulating oil
-
May
-
A. M. Emsley, X. Xiao, R. J. Heywood, and M. Ali, "Degradation ofcellulosic insulation in power Transformers. Part 2: Formation of furan products in insulating oil", IEE Proc. Sci. Meas. Technol., May 2000, Vol. 147, No. 3, pp 110-115.
-
(2000)
IEE Proc. Sci. Meas. Technol.
, vol.147
, Issue.3
, pp. 110-115
-
-
Emsley, A.M.1
Xiao, X.2
Heywood, R.J.3
Ali, M.4
-
5
-
-
0346076735
-
Aging of Oil-Impregnated paper in Power transformers
-
L. Lundgaard, W. Hansen, D. Linhjell, and T. Painter, "Aging of Oil-Impregnated paper in Power transformers", IEEE Trans Pow. Del. 2004, Vol. 19, No. 1, pp. 230 -239.
-
(2004)
IEEE Trans Pow. Del.
, vol.19
, Issue.1
, pp. 230-239
-
-
Lundgaard, L.1
Hansen, W.2
Linhjell, D.3
Painter, T.4
-
6
-
-
0022148642
-
A Review of Paper Aging in Power Transformers
-
D. H. Shroff, C. Eng, and A. W. Stannet, "A Review of Paper Aging in Power Transformers", IEE Proceedings, Vol. 132, Pt. C, No. 6, pp. 312-219, 1985.
-
(1985)
IEE Proceedings
, vol.132
, Issue.6 PART C
, pp. 312-1219
-
-
Shroff, D.H.1
Eng, C.2
Stannet, A.W.3
-
7
-
-
0014794592
-
Nouveax criteres pour caracteriser la degradation thermique d'une isolation a base de papier
-
B. Bouvier, "Nouveax criteres pour caracteriser la degradation thermique d'une isolation a base de papier", Rev. Gen. Elec., 1970, Vol. 79, pp 489-496.
-
(1970)
Rev. Gen. Elec.
, vol.79
, pp. 489-496
-
-
Bouvier, B.1
-
10
-
-
85051771879
-
Transformer Aging Research on Furanic Compounds Dissolved in Insulating Oil
-
CIGRE, Paper 15-302
-
I. Höhlein, H. Lütke, A. and J. Kachler, "Transformer Aging Research on Furanic Compounds Dissolved in Insulating Oil", CIGRE, Paper 15-302, CIGRE session 2002, Paris.
-
CIGRE Session 2002, Paris
-
-
Höhlein, I.1
Lütke, H.2
Kachler, A.J.3
-
11
-
-
0002416206
-
Furanic Compounds Analysis: A Tool for Predictive Maintenance of Oil-Filled Electrical Equipment
-
A. De Pablo, and B. Pahlavanpour, "Furanic Compounds Analysis: A Tool for Predictive Maintenance of Oil-Filled Electrical Equipment", Electra, Nr. 175, pp 9-18.
-
Electra
, Issue.175
, pp. 9-18
-
-
De Pablo, A.1
Pahlavanpour, B.2
-
12
-
-
0003582240
-
-
CIGRE, Paper 137, (Paris)
-
J. Fabre, andA. Pichon, "Deteriorating Processes and Products of Paper in Oil. Application to Transformers", CIGRE, Paper 137, (Paris), 1960.
-
(1960)
Deteriorating Processes and Products of Paper in Oil. Application to Transformers
-
-
Fabre, J.1
Pichon, A.2
-
14
-
-
84857221852
-
Use of Oil Testing to Determine Transformer Condition and Life Extension
-
Books
-
Moore, Harold R., "Use of Oil Testing to Determine Transformer Condition and Life Extension", Tech Con 98, New Orleans, LA. February 16-18, 1998. Books
-
Tech Con 98, New Orleans, LA. February 16-18, 1998
-
-
Moore Harold, R.1
-
15
-
-
0032186594
-
A Combined ANN and Expert System Tool for Transformer Fault Diagnose
-
October
-
Zhenyuan Wang, Yilu liu, and Paul J.Griffin, A Combined ANN and Expert System Tool for Transformer Fault Diagnose, IEEE Transactions on Power Delivery, October 1998, Vol. 13, NO.4.
-
(1998)
IEEE Transactions on Power Delivery
, vol.13
, Issue.4
-
-
Wang, Z.1
Liu, Y.2
Griffin, P.J.3
-
16
-
-
0034186792
-
A Fuzy Dissolved Gas Analysis Method for the Diagnoses of Multipe Incipient Faults in a Transformer
-
May
-
Q.Su, C.Mi, L.L.Lai, and P. Austin, A Fuzy Dissolved Gas Analysis Method for the Diagnoses of Multipe Incipient Faults in a Transformer", IEEE Transaction on Power Systems, May 2000, Vol. 15. No.2.
-
(2000)
IEEE Transaction on Power Systems
, vol.15
, Issue.2
-
-
Su, Q.1
Mi, C.2
Lai, L.L.3
Austin, P.4
-
17
-
-
0032136423
-
Intelligent Decision Support for Diagnoses of Incipient Transformer Faults Using Self-Organizing Polynomial Networks
-
August
-
Hong-Tzer Yang, "Intelligent Decision Support for Diagnoses of Incipient Transformer Faults Using Self-Organizing Polynomial Networks", IEEE Transactions on Power Systems, August 1998, Vol. 13, No.3.
-
(1998)
IEEE Transactions on Power Systems
, vol.13
, Issue.3
-
-
Yang, H.-T.1
-
18
-
-
0346076735
-
Aging of Oil-Impregnated Paper in Power Transformers
-
January
-
Lars E. Lundgaard, Walter Hansen, Dag Linhjell, and Terence J. Painter, Aging of Oil-Impregnated Paper in Power Transformers, IEEE Transactions on Power Delivery, January, 2004, Vol.19, No.1.
-
(2004)
IEEE Transactions on Power Delivery
, vol.19
, Issue.1
-
-
Lundgaard, L.E.1
Hansen, W.2
Linhjell, D.3
Painter, T.J.4
-
20
-
-
80052111875
-
Application of Modern Technology for Fault Diagnosis in Power Transformers Energy Management
-
Hasmat Malik, R.K. Jarial, A.Zeem and A.K.Y, "Application of Modern Technology for Fault Diagnosis in Power Transformers Energy Management", IEEE International Conference on Communication Systems and Network Technologies, June 2011,pp. 376-381.
-
IEEE International Conference on Communication Systems and Network Technologies, June 2011
, pp. 376-381
-
-
Hasmat Malik1
Jarial, R.K.2
Zeem, A.3
Y, A.K.4
|