Application of modern technology for fault diagnosis in power transformers energy management

Author keywords

Analyser; Chromatograph; Diagnostics; Fault; Spectroscopy; Transformer

Indexed keywords

ANALYSER; CATASTROPHIC FAILURES; CHROMATOGRAPH; CONTINUOUS MONITORING; DIELECTRIC CIRCUIT; DISTRIBUTION TRANSFORMER; FAULT; INCIPIENT FAULTS; MODERN TECHNOLOGIES; OPERATION AND MAINTENANCE; POWER SUPPLY; STRUCTURAL FAILURE; TRANSFORMER; UNINTERRUPTED POWER SUPPLY;

EID: 80052111875     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CSNT.2011.84     Document Type: Conference Paper
Times cited : (19)

References (18)
  • 1
    • 80052113040 scopus 로고    scopus 로고
    • Increasing life of distribution transformer through energy audit
    • Dr. Dec. IIT New Delhi, India
    • Dr. Zakir Hussain: "Increasing life of distribution transformer through energy audit", International Conf. on Power Generation, System Planning and Operation, Dec. 1997, IIT New Delhi, India, pp 207-214
    • (1997) International Conf. on Power Generation, System Planning and Operation , pp. 207-214
    • Hussain, Z.1
  • 2
    • 50649083110 scopus 로고    scopus 로고
    • Review of modern diagnostics techniques for assessing insulation condion in aged transformer
    • Nov.
    • Verma P, "Review of Modern Diagnostics Techniques for assessing Insulation condion in aged Transformer", Electrical Review, Nov.2005, Vol XII, No-11, pp 26-29.
    • (2005) Electrical Review , vol.12 , Issue.11 , pp. 26-29
    • Verma, P.1
  • 8
    • 58049093453 scopus 로고    scopus 로고
    • Institut fur Energieversorgung und Hoschspannungstechnik der Universitat Hannover Schering Institute
    • H. Borsi, "Diagnose von Leistungtransformatoren" Institut fur Energieversorgung und Hoschspannungstechnik der Universitat Hannover Schering Institute
    • Diagnose von Leistungtransformatoren
    • Borsi, H.1
  • 9
    • 42549086502 scopus 로고    scopus 로고
    • Transformer diagnostic testing by SFRA
    • Sep.
    • Yadav Ashok K., Taneja Subhash C., "Transformer diagnostic testing by SFRA", The Journal of CPRI, vol.2, No.2, Sep. 2005, pp 177-185
    • (2005) The Journal of CPRI , vol.2 , Issue.2 , pp. 177-185
    • Yadav Ashok, K.1    Taneja Subhash, C.2
  • 10
    • 33645822324 scopus 로고    scopus 로고
    • Cellulose insulation in oil-filled power transformers: Part II-maintaining insulation integrity and life
    • March-April
    • Oommen T.V, Prevost T.A, "Cellulose insulation in oil-filled power transformers: part II-Maintaining insulation integrity and life", IEEE Electrical Insulation Magazine, vol. 22, Issue 2, March-April 2006, pp. 5-14
    • (2006) IEEE Electrical Insulation Magazine , vol.22 , Issue.2 , pp. 5-14
    • Oommen, T.V.1    Prevost, T.A.2
  • 11
    • 33947256235 scopus 로고    scopus 로고
    • Cellulose insulation in oil-filled power transformers: Part I - History and development
    • Jan.-Feb.
    • Prevost T.A.; Oommen T.V, "Cellulose insulation in oil-filled power transformers: Part I - History and development", IEEE Electrical Insulation Magazine, vol.22, Issue 1, Jan.-Feb. 2006, pp. 28-35.
    • (2006) IEEE Electrical Insulation Magazine , vol.22 , Issue.1 , pp. 28-35
    • Prevost, T.A.1    Oommen, T.V.2
  • 12
  • 13
    • 77950513564 scopus 로고    scopus 로고
    • Creating a preliminary model for estimating degree of polymerization of thermally upgraded paper based on furan concentrations in transformer oil
    • S D Myers Inc. Boston, Apr.
    • Shkolnik A. B., Bigin K.M, and Kelly J.J. (S D Myers Inc.), "Creating a preliminary model for estimating degree of polymerization of thermally upgraded paper based on furan concentrations in transformer oil," Doble Conf. Paper, Boston, Apr. 1999
    • (1999) Doble Conf. Paper
    • Shkolnik, A.B.1    Bigin, K.M.2    Kelly, J.J.3
  • 14
    • 0344872364 scopus 로고
    • Power transformer insulation ageing
    • Sydney, Australia
    • Pahlavanapour B., "Power transformer insulation ageing," CIGRE SC 15 Symp., Sydney, Australia, 1995.
    • (1995) CIGRE SC 15 Symp.
    • Pahlavanapour, B.1
  • 15
    • 80052136194 scopus 로고    scopus 로고
    • Furfural and ageing: How they are related
    • Liquids, National Grid Leatherhead, UK
    • DePablo A., "Furfural and ageing: How they are related," IEEE Power Division Colloquium Insul. Liquids, National Grid Leatherhead, UK 1999
    • (1999) IEEE Power Division Colloquium Insul
    • DePablo, A.1
  • 18
    • 77952954923 scopus 로고    scopus 로고
    • Partial discharge measurement of cryogenic dielectric materials in an HTS transformer using HFCT
    • June
    • S. H. Lee, S. Y. Jung, B. W. Lee: Partial discharge measurement of cryogenic Dielectric materials in an HTS transformer using HFCT, IEEE transactions on applied superconductivity, vol.20, no.3, June 2010
    • (2010) IEEE Transactions on Applied Superconductivity , vol.20 , Issue.3
    • Lee, S.H.1    Jung, S.Y.2    Lee, B.W.3