-
1
-
-
0032771288
-
Porous-coated cementless acetabular cups in revision surgery: A 6- to 11-year follow-up study
-
DOI 10.1016/S0883-5403(99)90094-3
-
Garcia-Cimbrelo E. Porous-coated cementless acetabular cups in revision surgery: a 6- to 11-year follow-up study. J Arthroplast. 1999;14:397-406. (Pubitemid 29329791)
-
(1999)
Journal of Arthroplasty
, vol.14
, Issue.4
, pp. 397-406
-
-
Garcia-Cimbrelo, E.1
-
2
-
-
0030882690
-
Isolated revision acetabuloplasty using a porous-coated cementless acetabular component without removal of a well-fixed femoral component: A 3- to 9-year follow-up study
-
DOI 10.1016/S0883-5403(97)90000-0
-
Moskal JT, Danisa OA, Shaffrey CI. Isolated revision acetabuloplasty using a porous-coated cementless acetabular component without removal of a well-fixed femoral component. A 3- to 9-year follow-up study. J Arthroplast. 1997;12:719-27. (Pubitemid 27452603)
-
(1997)
Journal of Arthroplasty
, vol.12
, Issue.7
, pp. 719-727
-
-
Moskal, J.T.1
Danisa, O.A.2
Shaffrey, C.I.3
-
3
-
-
0029793627
-
Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years
-
Silverton CD, Rosenberg AG, Sheinkop MB, Kull LR, Galante JO. Revision of the acetabular component without cement after total hip arthroplasty. A follow-up note regarding results at seven to eleven years. J Bone Joint Surg Am. 1996;78:1366-70. (Pubitemid 26336888)
-
(1996)
Journal of Bone and Joint Surgery - Series A
, vol.78
, Issue.9
, pp. 1366-1370
-
-
Silverton, C.D.1
Rosenberg, A.G.2
Sheinkop, M.B.3
Kull, L.R.4
Galante, J.O.5
-
4
-
-
0027174572
-
Revision of the acetabular component without cement after total hip arthroplasty. Three to six-year follow-up
-
Padgett DE, Kull L, Rosenberg A, Sumner DR, Galante JO. Revision of the acetabular component without cement after total hip arthroplasty. Three to six-year follow-up. J Bone Joint Surg Am. 1993;75:663-73. (Pubitemid 23199099)
-
(1993)
Journal of Bone and Joint Surgery - Series A
, vol.75
, Issue.5
, pp. 663-673
-
-
Padgett, D.E.1
Kull, L.2
Rosenberg, A.3
Sumner, D.R.4
Galante, J.O.5
-
6
-
-
0033981259
-
Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency
-
Chen WM, Engh CA Jr, Hopper RH Jr, McAuley JP, Engh CA. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency. J Bone Joint Surg Am. 2000;82:197-206. (Pubitemid 30097019)
-
(2000)
Journal of Bone and Joint Surgery - Series A
, vol.82
, Issue.2
, pp. 197-206
-
-
Chen, W.-M.1
Engh Jr., C.A.2
Hopper Jr., R.H.3
Mcauley, J.P.4
Engh, C.A.5
-
7
-
-
0029042750
-
Acetabular reconstruction using bipolar endoprosthesis and bone grafting in patients with severe bone deficiency
-
Papagelopoulos PJ, Lewallen DG, Cabanela ME, McFarland EG, Wallrichs SL. Acetabular reconstruction using bipolar endoprosthesis and bone grafting in patients with severe bone deficiency. Clin Orthop Relat Res. 1995;314:170-84.
-
(1995)
Clin Orthop Relat Res
, vol.314
, pp. 170-184
-
-
Papagelopoulos, P.J.1
Lewallen, D.G.2
Cabanela, M.E.3
McFarland, E.G.4
Wallrichs, S.L.5
-
8
-
-
34147154144
-
Revision total hip arthroplasty for pelvic discontinuity
-
DOI 10.2106/JBJS.F.00313
-
DeBoer DK, Christie MJ, Brinson MF, Morrison JC. Revision total hip arthroplasty for pelvic discontinuity. J Bone Joint Surg Am. 2007;89:835-40. (Pubitemid 46564290)
-
(2007)
Journal of Bone and Joint Surgery - Series A
, vol.89
, Issue.4
, pp. 835-840
-
-
DeBoer, D.K.1
Christie, M.J.2
Brinson, M.F.3
Morrison, J.C.4
-
9
-
-
33644801512
-
The treatment of acetabular bone defects with an associated pelvic discontinuity
-
DOI 10.1097/01.blo.0000194311.20901.f9, PII 0000308620051200000033
-
Paprosky WG, O'Rourke M, Sporer SM. The treatment of acetabular bone defects with an associated pelvic discontinuity. Clin Orthop Relat Res. 2005;441:216-20. (Pubitemid 44384224)
-
(2005)
Clinical Orthopaedics and Related Research
, Issue.441
, pp. 216-220
-
-
Paprosky, W.G.1
O'Rourke, M.2
Sporer, S.M.3
-
10
-
-
0023712045
-
Results of acetabular revisions with newer cement techniques
-
Fuchs MD, Salvati EA, Wilson PD Jr, Sculco TP, Pellicci PM. Results of acetabular revisions with newer cement techniques. Orthop Clin N Am. 1988;19:649-55.
-
(1988)
Orthop Clin N Am
, vol.19
, pp. 649-655
-
-
Fuchs, M.D.1
Salvati, E.A.2
Wilson Jr., P.D.3
Sculco, T.P.4
Pellicci, P.M.5
-
11
-
-
0018601394
-
The results of revision of total hip arthroplasty
-
Hunter GA, Welsh RP, Cameron HU, Bailey WH. The results of revision of total hip arthroplasty. J Bone Joint Surg Br. 1979;61:419-21. (Pubitemid 10201800)
-
(1979)
Journal of Bone and Joint Surgery - Series B
, vol.61
, Issue.4
, pp. 419-421
-
-
Hunter, G.A.1
Welsh, R.P.2
Cameron, H.U.3
Bailey, W.H.4
-
12
-
-
0024368926
-
Classification and management of acetabular abnormalities in total hip arthroplasty
-
D'Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG, et al. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989;243:126-37. (Pubitemid 19165374)
-
(1989)
Clinical Orthopaedics and Related Research
, Issue.243
, pp. 126-137
-
-
D'Antonio, J.A.1
Capello, W.N.2
Borden, L.S.3
Bargar, W.L.4
Bierbaum, B.F.5
Boettcher, W.G.6
Steinberg, M.E.7
Stulberg, S.D.8
Wedge, J.H.9
-
14
-
-
0032895219
-
Mechanical considerations in impaction bone grafting
-
DOI 10.1302/0301-620X.81B1.8480
-
Brewster NT, Gillespie WJ, Howie CR, Madabhushi SP, Usmani AS, Fairbairn DR. Mechanical considerations in impaction bone grafting. J Bone Joint Surg Br. 1999;81:118-24. (Pubitemid 29043424)
-
(1999)
Journal of Bone and Joint Surgery - Series B
, vol.81
, Issue.1
, pp. 118-124
-
-
Brewster, N.T.1
Gillespie, W.J.2
Howie, C.R.3
Madabhushi, S.P.G.4
Usmani, A.S.5
Fairbairn, D.R.6
-
15
-
-
0345004135
-
Subsidence of a non-polished stem in revisions of the hip using impaction allograft
-
DOI 10.1302/0301-620X.81B1.8922
-
Karrholm J, Hultmark P, Carlsson L, Malchau H. Subsidence of a non-polished stem in revisions of the hip using impaction allograft. Evaluation with radiostereometry and dual-energy X-ray absorptiometry. J Bone Joint Surg Br. 1999;81:135-42. (Pubitemid 29043427)
-
(1999)
Journal of Bone and Joint Surgery - Series B
, vol.81
, Issue.1
, pp. 135-142
-
-
Karrholm, J.1
Hultmark, P.2
Carlsson, L.3
Malchau, H.4
-
16
-
-
0030069836
-
Acetabular and femoral reconstruction with impacted graft and cement
-
Slooff TJ, Buma P, Schreurs BW, Schimmel JW, Huiskes R, Gardeniers J. Acetabular and femoral reconstruction with impacted graft and cement. Clin Orthop Relat Res. 1996;324: 108-15. (Pubitemid 26071756)
-
(1996)
Clinical Orthopaedics and Related Research
, Issue.324
, pp. 108-115
-
-
Slooff, T.J.J.H.1
Buma, P.2
Schreurs, B.W.3
Schimmel, J.W.4
Huiskes, R.5
Gardeniers, J.6
-
17
-
-
80051545924
-
Mechanical properties of 7-10 mm bone grafts and small slurry grafts in impaction bone grafting
-
Xu ZJ, Chen LY, Zhong C, Tan YB, He RX. Mechanical properties of 7-10 mm bone grafts and small slurry grafts in impaction bone grafting. J Orthop Res. 2011;29:1491-5.
-
(2011)
J Orthop Res
, vol.29
, pp. 1491-1495
-
-
Xu, Z.J.1
Chen, L.Y.2
Zhong, C.3
Tan, Y.B.4
He, R.X.5
-
18
-
-
0013818212
-
Idiopathic necrosis of the femoral head in adults
-
Merle D'Aubigne R, Postel M, Mazabraud A, Massias P, Gueguen J, France P. Idiopathic necrosis of the femoral head in adults. J Bone Joint Surg Br. 1965;47:612-33.
-
(1965)
J Bone Joint Surg Br
, vol.47
, pp. 612-633
-
-
Merle D'Aubigne, R.1
Postel, M.2
Mazabraud, A.3
Massias, P.4
Gueguen, J.5
France, P.6
-
21
-
-
0026442786
-
The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years
-
Schmalzried TP, Harris WH. The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years. J Bone Joint Surg Am. 1992;74:1130-9.
-
(1992)
J Bone Joint Surg Am
, vol.74
, pp. 1130-1139
-
-
Schmalzried, T.P.1
Harris, W.H.2
-
22
-
-
0027413687
-
Impacted cancellous allografts and cement for revision total hip arthroplasty
-
Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br. 1993;75:14-21. (Pubitemid 23052407)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.1
, pp. 14-21
-
-
Gie, G.A.1
Linder, L.2
Ling, R.S.M.3
Simon, J.-P.4
Slooff, T.J.J.H.5
Timperley, A.J.6
-
23
-
-
33845382806
-
Nonparametric estimation from incomplete observations
-
Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457-81.
-
(1958)
J Am Stat Assoc
, vol.53
, pp. 457-481
-
-
Kaplan, E.L.1
Meier, P.2
-
25
-
-
0030852061
-
Reinforcement rings for deficient acetabular bone in revision surgery: Long-term results
-
Garcia-Cimbrelo E, Alonso-Biarge J, Cordero-Ampuero J. Reinforcement rings for deficient acetabular bone in revision surgery: long-term results. Hip Int. 1997;7:57-63.
-
(1997)
Hip Int
, vol.7
, pp. 57-63
-
-
Garcia-Cimbrelo, E.1
Alonso-Biarge, J.2
Cordero-Ampuero, J.3
-
26
-
-
0026785585
-
Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency
-
Berry DJ, Muller ME. Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency. J Bone Joint Surg Br. 1992;74:711-5.
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 711-715
-
-
Berry, D.J.1
Muller, M.E.2
-
27
-
-
9644270215
-
Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty
-
DOI 10.1097/01.blo.0000150133.88271.80
-
Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201-8. (Pubitemid 39579213)
-
(2004)
Clinical Orthopaedics and Related Research
, Issue.429
, pp. 201-208
-
-
Nehme, A.1
Lewallen, D.G.2
Hanssen, A.D.3
-
28
-
-
0035215222
-
Technical factors for success with metal ring acetabular reconstruction
-
DOI 10.1054/arth.2001.27669
-
Udomkiat P, Dorr LD, Won YY, Longjohn D, Wan Z. Technical factors for success with metal ring acetabular reconstruction. J Arthroplast. 2001;16:961-9. (Pubitemid 33151870)
-
(2001)
Journal of Arthroplasty
, vol.16
, Issue.8
, pp. 961-969
-
-
Udomkiat, P.1
Dorr, L.D.2
Won, Y.-Y.3
Longjohn, D.4
Wan, Z.5
-
29
-
-
0033852227
-
The Kerboull acetabular reinforcement device in major acetabular reconstructions
-
Kerboull M, Hamadouche M, Kerboull L. The Kerboull acetabular reinforcement device in major acetabular reconstructions. Clin Orthop Relat Res. 2000;378:155-68.
-
(2000)
Clin Orthop Relat Res
, vol.378
, pp. 155-168
-
-
Kerboull, M.1
Hamadouche, M.2
Kerboull, L.3
-
30
-
-
0025172181
-
Acetabular reconstruction with a bipolar prosthesis and morseled bone grafts
-
Brien WW, Bruce WJ, Salvati EA, Wilson PD Jr, Pellicci PM. Acetabular reconstruction with a bipolar prosthesis and morseled bone grafts. J Bone Joint Surg Am. 1990;72:1230-5. (Pubitemid 20343171)
-
(1990)
Journal of Bone and Joint Surgery - Series A
, vol.72
, Issue.8
, pp. 1230-1235
-
-
Brien, W.W.1
Bruce, W.J.2
Salvati, E.A.3
Wilson Jr., P.D.4
Pellicci, P.M.5
-
31
-
-
0024842454
-
The fate of acetabular allografts after bipolar revision arthroplasty of the hip. A radiographic review
-
Wilson MG, Nikpoor N, Aliabadi P, Poss R, Weissman BN. The fate of acetabular allografts after bipolar revision arthroplasty of the hip. A radiographic review. J Bone Joint Surg Am. 1989;71: 1469-79. (Pubitemid 20054462)
-
(1989)
Journal of Bone and Joint Surgery - Series A
, vol.71
, Issue.10
, pp. 1469-1479
-
-
Wilson, M.G.1
Nikpoor, N.2
Aliabadi, P.3
Poss, R.4
Weissman, B.N.5
-
32
-
-
0031851235
-
An oblong revision cup for large acetabular defects: Design rationale and two- to seven-year follow-up
-
DOI 10.1016/S0883-5403(98)90056-0
-
Koster G, Willert HG, Kohler HP, Dopkens K. An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplast. 1998;13:559-69. (Pubitemid 28380815)
-
(1998)
Journal of Arthroplasty
, vol.13
, Issue.5
, pp. 559-569
-
-
Koster, G.1
Willert, H.-G.2
Kohler, H.-P.3
Dopkens, K.4
-
33
-
-
33747875028
-
Management of Types III and IV Acetabular Deficiencies With the Longitudinal Oblong Revision Cup
-
DOI 10.1016/j.arth.2005.08.026, PII S0883540305006844
-
Herrera A, Martinez AA, Cuenca J, Canales V. Management of types III and IV acetabular deficiencies with the longitudinal oblong revision cup. J Arthroplast. 2006;21:857-64. (Pubitemid 44293242)
-
(2006)
Journal of Arthroplasty
, vol.21
, Issue.6
, pp. 857-864
-
-
Herrera, A.1
Martinez, A.A.2
Cuenca, J.3
Canales, V.4
-
34
-
-
0035181128
-
Bridging massive acetabular defects with the triflange cup: 2- to 9-year results
-
Christie MJ, Barrington SA, Brinson MF, Ruhling ME, DeBoer DK. Bridging massive acetabular defects with the triflange cup: 2- to 9-year results. Clin Orthop Relat Res. 2001;393:216-27. (Pubitemid 33101715)
-
(2001)
Clinical Orthopaedics and Related Research
, Issue.393
, pp. 216-227
-
-
Christie, M.J.1
Barrington, S.A.2
Brinson, M.F.3
Ruhling, M.E.4
DeBoer, D.K.5
-
35
-
-
9644281446
-
Use of custom triflanged acetabular components in revision total hip arthroplasty
-
DOI 10.1097/01.blo.0000150252.19780.74
-
Holt GE, Dennis DA. Use of custom triflanged acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2004;429:209-14. (Pubitemid 39579214)
-
(2004)
Clinical Orthopaedics and Related Research
, Issue.429
, pp. 209-214
-
-
Holt, G.E.1
Dennis, D.A.2
-
36
-
-
34548284861
-
The Use of Tantalum Porous Metal Implants for Paprosky 3A and 3B Defects
-
DOI 10.1016/j.arth.2007.04.024, PII S0883540307002513
-
Weeden SH, Schmidt RH. The use of tantalum porous metal implants for Paprosky 3A and 3B defects. J Arthroplast. 2007;22:151-5. (Pubitemid 47333023)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.6 SUPPL.
, pp. 151-155
-
-
Weeden, S.H.1
Schmidt, R.H.2
-
37
-
-
52049089951
-
Management of severe bone loss in acetabular revision using a trabecular metal shell
-
Flecher X, Sporer S, Paprosky W. Management of severe bone loss in acetabular revision using a trabecular metal shell. J Arthroplast. 2008;23:949-55.
-
(2008)
J Arthroplast
, vol.23
, pp. 949-955
-
-
Flecher, X.1
Sporer, S.2
Paprosky, W.3
|