-
1
-
-
84858708881
-
-
The national dialysis access survey - preliminary results. UK Renal Registry Report. Chapter 6
-
The national dialysis access survey - preliminary results. UK Renal Registry Report. Chapter 6: 94-96, 2005
-
(2005)
, pp. 94-96
-
-
-
2
-
-
3342975641
-
Locking of tunnelled hemodialysis catheters with gentamicin and heparin
-
McIntyre CW, Hulme LJ, Taal M, Fluck RJ: Locking of tunnelled hemodialysis catheters with gentamicin and heparin. Kidney Int 66:801-805, 2004
-
(2004)
Kidney Int
, vol.66
, pp. 801-805
-
-
McIntyre, C.W.1
Hulme, L.J.2
Taal, M.3
Fluck, R.J.4
-
3
-
-
0036063589
-
Prevention of tunnelled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomised control study
-
Dogra GK, Herson H, Hutchison B, Irish AB, Heath CH, Golledge C, Luxton G, Moody H: Prevention of tunnelled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomised control study. J Am Soc Nephrol 13:2133-2139, 2002
-
(2002)
J Am Soc Nephrol
, vol.13
, pp. 2133-2139
-
-
Dogra, G.K.1
Herson, H.2
Hutchison, B.3
Irish, A.B.4
Heath, C.H.5
Golledge, C.6
Luxton, G.7
Moody, H.8
-
4
-
-
33748748203
-
Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia
-
Nori US, Manoharan A, Yee J, Besarab A: Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia. Am J Kidney Dis 48:596-605, 2006
-
(2006)
Am J Kidney Dis
, vol.48
, pp. 596-605
-
-
Nori, U.S.1
Manoharan, A.2
Yee, J.3
Besarab, A.4
-
5
-
-
33746174152
-
Enhancing the survival of tunnelled hemodialysis catheters using an antibiotic lock in the elderly: a randomised, double-blind clinical trial
-
Saxena AK, Panhotra BR, Sundaram DS, Naguib M, Morsy F, Al-Arabi Al-Ghamdi AM: Enhancing the survival of tunnelled hemodialysis catheters using an antibiotic lock in the elderly: a randomised, double-blind clinical trial. Nephrology 11:299-305, 2006
-
(2006)
Nephrology
, vol.11
, pp. 299-305
-
-
Saxena, A.K.1
Panhotra, B.R.2
Sundaram, D.S.3
Naguib, M.4
Morsy, F.5
Al-Arabi Al-Ghamdi, A.M.6
-
6
-
-
44449152491
-
Preventing hemodialysis catheter-related bacteremia with an antimicrobial lock solution: a meta-analysis of prospective randomized trials
-
Labriola L, Crott R, Jadoul M: Preventing hemodialysis catheter-related bacteremia with an antimicrobial lock solution: a meta-analysis of prospective randomized trials. Nephrol Dial Transplant 23:1666-1672, 2008
-
(2008)
Nephrol Dial Transplant
, vol.23
, pp. 1666-1672
-
-
Labriola, L.1
Crott, R.2
Jadoul, M.3
-
7
-
-
46249086815
-
Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: systematic review and meta-analysis of randomized, controlled trials
-
Yahav D, Rozen-Zvi B, Gafter-Gvili A, Leibovici L, Gafter U, Paul M: Antimicrobial lock solutions for the prevention of infections associated with intravascular catheters in patients undergoing hemodialysis: systematic review and meta-analysis of randomized, controlled trials. Clin Infect Dis 47:83-93, 2008
-
(2008)
Clin Infect Dis
, vol.47
, pp. 83-93
-
-
Yahav, D.1
Rozen-Zvi, B.2
Gafter-Gvili, A.3
Leibovici, L.4
Gafter, U.5
Paul, M.6
-
8
-
-
77958590280
-
Emergence of gentamicin-resistant bacteremia in hemodialysis patients receiving gentamicin lock catheter prophylaxis
-
Landry DL, Braden GL, Gobeille SL, Haessler SD, Vaidya CK, Sweet SJ: Emergence of gentamicin-resistant bacteremia in hemodialysis patients receiving gentamicin lock catheter prophylaxis. Clin J Am Soc Nephrol 10:1799-1804, 2010
-
(2010)
Clin J Am Soc Nephrol
, vol.10
, pp. 1799-1804
-
-
Landry, D.L.1
Braden, G.L.2
Gobeille, S.L.3
Haessler, S.D.4
Vaidya, C.K.5
Sweet, S.J.6
-
9
-
-
73649114226
-
Effect of catheter-lock solutions on catheter-related infection and inflammatory syndrome in hemodialysis patients: heparin versus citrate 46% versus heparin/gentamicin
-
Venditto M, Tezenas du Montcel S, Robert J, Robert J, Trystam D, Dighiero J, Hue D, Bessette C, Deray G, Mercadal L: Effect of catheter-lock solutions on catheter-related infection and inflammatory syndrome in hemodialysis patients: heparin versus citrate 46% versus heparin/gentamicin. Blood Purif 29:268-273, 2010
-
(2010)
Blood Purif
, vol.29
, pp. 268-273
-
-
Venditto, M.1
Tezenas du Montcel, S.2
Robert, J.3
Robert, J.4
Trystam, D.5
Dighiero, J.6
Hue, D.7
Bessette, C.8
Deray, G.9
Mercadal, L.10
-
10
-
-
84858709655
-
-
Does the use of line locks lead to antibiotic resistant organisms as compared with systemic antibiotics alone in the treatment of hemodialysis catheter infections? (abstract) Liverpool: Renal Association, P119
-
Dixon J, Steele M, Makanjuola D: Does the use of line locks lead to antibiotic resistant organisms as compared with systemic antibiotics alone in the treatment of hemodialysis catheter infections? (abstract) Liverpool: Renal Association, 2009: P119
-
(2009)
-
-
Dixon, J.1
Steele, M.2
Makanjuola, D.3
-
11
-
-
0036007330
-
Prevention of hemodialysis catheter-related bloodstream infection using an antimicrobial lock
-
Quarello F, Forneris G: Prevention of hemodialysis catheter-related bloodstream infection using an antimicrobial lock. Blood Purif 20:87-92, 2002
-
(2002)
Blood Purif
, vol.20
, pp. 87-92
-
-
Quarello, F.1
Forneris, G.2
-
12
-
-
50449096050
-
A new hemodialysis catheter-locking agent reduces infections in hemodialysis patients
-
Taylor C, Cahill J, Gerrish M, Little J: A new hemodialysis catheter-locking agent reduces infections in hemodialysis patients. J Ren Care 34(3):116-120, 2008
-
(2008)
J Ren Care
, vol.34
, Issue.3
, pp. 116-120
-
-
Taylor, C.1
Cahill, J.2
Gerrish, M.3
Little, J.4
-
13
-
-
18744363007
-
Taurolidine lock: the key to prevention of recurrent catheter-related bloodstream infections
-
Jurewitsch B, Jeejeebhoy KN: Taurolidine lock: the key to prevention of recurrent catheter-related bloodstream infections. Clin Nutr 24:462-465, 2005
-
(2005)
Clin Nutr
, vol.24
, pp. 462-465
-
-
Jurewitsch, B.1
Jeejeebhoy, K.N.2
-
14
-
-
0038548201
-
Prophylaxis against dialysis catheter-related bacteremia with a novel antimicrobial lock solution
-
Allon M: Prophylaxis against dialysis catheter-related bacteremia with a novel antimicrobial lock solution. Clin Infect Dis 36:1539-1544, 2003
-
(2003)
Clin Infect Dis
, vol.36
, pp. 1539-1544
-
-
Allon, M.1
-
15
-
-
2942735234
-
Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution
-
Betjes MGH, van Agteren M: Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution. Nephrol Dial Transplant 19(6):1546-1551, 2004
-
(2004)
Nephrol Dial Transplant
, vol.19
, Issue.6
, pp. 1546-1551
-
-
Betjes, M.G.H.1
van Agteren, M.2
-
16
-
-
0036093266
-
Antimicrobial activity of a novel catheter lock solution
-
Shah CB, Mittelman MW, Costerton JW, Parenteau S, Pelak M, Arsenault R, Mermel LA: Antimicrobial activity of a novel catheter lock solution. Antimicrob Agents Chemother 46:1674-1679, 2002
-
(2002)
Antimicrob Agents Chemother
, vol.46
, pp. 1674-1679
-
-
Shah, C.B.1
Mittelman, M.W.2
Costerton, J.W.3
Parenteau, S.4
Pelak, M.5
Arsenault, R.6
Mermel, L.A.7
-
17
-
-
77952542208
-
A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis
-
Solomon LR, Cheesbrough JS, Ebah L, Al-Sayed T, Heap M, Milband M, Waterhouse D, Mitra S, Curry A, Saxena R, Bhat R, Schulz M, Diggle P: A randomized double-blind controlled trial of taurolidine-citrate catheter locks for the prevention of bacteremia in patients treated with hemodialysis. Am J Kidney Dis 55:1069-1078, 2010
-
(2010)
Am J Kidney Dis
, vol.55
, pp. 1069-1078
-
-
Solomon, L.R.1
Cheesbrough, J.S.2
Ebah, L.3
Al-Sayed, T.4
Heap, M.5
Milband, M.6
Waterhouse, D.7
Mitra, S.8
Curry, A.9
Saxena, R.10
Bhat, R.11
Schulz, M.12
Diggle, P.13
-
18
-
-
33947529736
-
Catheter lock solution - taurolock for prevention of catheter-related bacteremia in hemodialysis patients
-
Geron R, Tanchileski O, Kristal B: Catheter lock solution - taurolock for prevention of catheter-related bacteremia in hemodialysis patients. Harefuah 145:881-884, 2006
-
(2006)
Harefuah
, vol.145
, pp. 881-884
-
-
Geron, R.1
Tanchileski, O.2
Kristal, B.3
-
19
-
-
77952994713
-
Diagnosis, prevention and treatment of hemodialysis catheter-related bloodstream infections (CRBSI): a position statement of European Renal Best Practice (ERBP)
-
Vanholder R, Canaud B, Fluck R, Jadoul M, Labriola L, Marti-Monros A, Tordoir J, Van Biesen W: Diagnosis, prevention and treatment of hemodialysis catheter-related bloodstream infections (CRBSI): a position statement of European Renal Best Practice (ERBP). NDT Plus 3:234-246, 2010
-
(2010)
NDT Plus
, vol.3
, pp. 234-246
-
-
Vanholder, R.1
Canaud, B.2
Fluck, R.3
Jadoul, M.4
Labriola, L.5
Marti-Monros, A.6
Tordoir, J.7
Van Biesen, W.8
-
20
-
-
84858703870
-
-
Renal Association clinical practice guidelines, vascular access for hemodialysis. Guideline 5.4.
-
Fluck R, Kumwenda M: Renal Association clinical practice guidelines, vascular access for hemodialysis. Guideline 5.4., 2010
-
(2010)
-
-
Fluck, R.1
Kumwenda, M.2
-
21
-
-
79251474918
-
Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activaror
-
Hemmelgarn BR, Moist LM, Lok CE, Tonelli M, Manns BJ, Holden RM, et al.: Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activaror. N Engl J Med 364:303-312, 2011
-
(2011)
N Engl J Med
, vol.364
, pp. 303-312
-
-
Hemmelgarn, B.R.1
Moist, L.M.2
Lok, C.E.3
Tonelli, M.4
Manns, B.J.5
Holden, R.M.6
-
22
-
-
34547208226
-
Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement
-
Yevzlin AS, Sanchez RJ, Hiatt JG, Washington MH, Wakeen M, Hofmann RM, Becker YT: Concentrated heparin lock is associated with major bleeding complications after tunneled hemodialysis catheter placement. Semin Dial 20:351-354, 2007
-
(2007)
Semin Dial
, vol.20
, pp. 351-354
-
-
Yevzlin, A.S.1
Sanchez, R.J.2
Hiatt, J.G.3
Washington, M.H.4
Wakeen, M.5
Hofmann, R.M.6
Becker, Y.T.7
-
23
-
-
0036900893
-
Superior antimicrobial activity of trisodium citrate over heparin for catheter locking
-
Weijmer MC, Debets-Ossenkopp YJ, Van de Vondervoort FJ, ter Wee PM: Superior antimicrobial activity of trisodium citrate over heparin for catheter locking. Nephrol Dial Transplant 17:2189-2195, 2002
-
(2002)
Nephrol Dial Transplant
, vol.17
, pp. 2189-2195
-
-
Weijmer, M.C.1
Debets-Ossenkopp, Y.J.2
Van de Vondervoort, F.J.3
ter Wee, P.M.4
-
24
-
-
54749107591
-
Locking solutions for hemodialysis catheters; heparin and citrate-a position paper by ASDIN
-
Moran JE, Ash S: Locking solutions for hemodialysis catheters; heparin and citrate-a position paper by ASDIN. Semin Dial 21:490-492, 2008
-
(2008)
Semin Dial
, vol.21
, pp. 490-492
-
-
Moran, J.E.1
Ash, S.2
-
25
-
-
77955758792
-
Does the heparin lock concentration affect hemodialysis catheter patency?
-
Maya ID, Smith T, Allon M: Does the heparin lock concentration affect hemodialysis catheter patency? Clin J Am Soc Nephrol 5:1458-1462, 2010
-
(2010)
Clin J Am Soc Nephrol
, vol.5
, pp. 1458-1462
-
-
Maya, I.D.1
Smith, T.2
Allon, M.3
-
26
-
-
33748032064
-
Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces
-
Shanks RM, Sargent JL, Martinez RM, Graber ML, O'Toole GA: Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces. Nephrol Dial Transplant 21:2247-2255, 2006
-
(2006)
Nephrol Dial Transplant
, vol.21
, pp. 2247-2255
-
-
Shanks, R.M.1
Sargent, J.L.2
Martinez, R.M.3
Graber, M.L.4
O'Toole, G.A.5
-
27
-
-
0242684598
-
Stability and in vitro efficacy of antibiotic-heparin lock solutions potentially useful for treatment of central venous catheter-related sepsis
-
Droste JC, Jeraj HA, MacDonald A, Farrington K: Stability and in vitro efficacy of antibiotic-heparin lock solutions potentially useful for treatment of central venous catheter-related sepsis. J Antimicrob Chemother 51:849-855, 2003
-
(2003)
J Antimicrob Chemother
, vol.51
, pp. 849-855
-
-
Droste, J.C.1
Jeraj, H.A.2
MacDonald, A.3
Farrington, K.4
-
29
-
-
30944443546
-
Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients
-
Weijmer MC, Van den Dorpel MA, Van de Ven PJG, ter Wee PM, Van Geelen JACA, Groeneveld JO, Van Jaarsveld BC, Koopmans MG, le Poole CY, Schrander-Van der Meer AM, Siegert CEH, Stas KJF: Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients. J Am Soc Nephrol 16:2769-2777, 2005
-
(2005)
J Am Soc Nephrol
, vol.16
, pp. 2769-2777
-
-
Weijmer, M.C.1
Van den Dorpel, M.A.2
Van de Ven, P.J.G.3
ter Wee, P.M.4
Van Geelen, J.A.C.A.5
Groeneveld, J.O.6
Van Jaarsveld, B.C.7
Koopmans, M.G.8
Le Poole, C.Y.9
Schrander-Van der Meer, A.M.10
Siegert, C.E.H.11
Stas, K.J.F.12
-
30
-
-
56749158831
-
Safety of concentrated trisodium citrate catheter locks
-
Polaschegg HD, Sodemann K: Safety of concentrated trisodium citrate catheter locks. Nephrol Dial Transplant 23:4075-4076, 2008
-
(2008)
Nephrol Dial Transplant
, vol.23
, pp. 4075-4076
-
-
Polaschegg, H.D.1
Sodemann, K.2
-
31
-
-
84858703869
-
-
US Food and Drug Administration: FDA issues warning on tricitrasol dialysis catheter anticoagulant. FDA Talk paper TOO-16 14 April 2000.
-
US Food and Drug Administration: FDA issues warning on tricitrasol dialysis catheter anticoagulant. FDA Talk paper TOO-16 14 April 2000.
-
-
-
-
32
-
-
33846671513
-
Trisodium citrate 4%-an alternative to heparin capping of Hemodialysis catheters
-
Lok CE, Appleton D, Bhola C, Khoo B, Richardson RM: Trisodium citrate 4%-an alternative to heparin capping of Hemodialysis catheters. Nephrol Dial Transplant 22:477-483, 2007
-
(2007)
Nephrol Dial Transplant
, vol.22
, pp. 477-483
-
-
Lok, C.E.1
Appleton, D.2
Bhola, C.3
Khoo, B.4
Richardson, R.M.5
-
33
-
-
33846657539
-
Sodium citrate 4% locking solution for central venous dialysis catheters-an effective, more cost-efficient alternative to heparin
-
Grudzinski L, Quinan P, Kwok S, Pierratos A: Sodium citrate 4% locking solution for central venous dialysis catheters-an effective, more cost-efficient alternative to heparin. Nephrol Dial Transplant 22:471-476, 2007
-
(2007)
Nephrol Dial Transplant
, vol.22
, pp. 471-476
-
-
Grudzinski, L.1
Quinan, P.2
Kwok, S.3
Pierratos, A.4
-
34
-
-
42549150104
-
Citrate 4% versus heparin and the reduction of thrombosis study (CHARTS)
-
MacRae JM, Dojcinovic I, Djurdjev O, Jung B, Shalansky S, Levin A, Kiaii M: Citrate 4% versus heparin and the reduction of thrombosis study (CHARTS). Clin J Am Soc Nephrol 3:369-374, 2008
-
(2008)
Clin J Am Soc Nephrol
, vol.3
, pp. 369-374
-
-
MacRae, J.M.1
Dojcinovic, I.2
Djurdjev, O.3
Jung, B.4
Shalansky, S.5
Levin, A.6
Kiaii, M.7
-
35
-
-
67349147029
-
Sodium citrate versus heparin catheter locks for cuffed central venous catheters: a single center randomised control trial of sodium citrate versus heparin line locks for cuffed central venous catheters
-
Power A, Duncan N, Singh SK, Brown W, Dalby E, Edwards C, Lynch K, Prout V, Cairns T, Griffith M, McLean A, Palmer A, Taube D: Sodium citrate versus heparin catheter locks for cuffed central venous catheters: a single center randomised control trial of sodium citrate versus heparin line locks for cuffed central venous catheters. Am J Kidney Dis 53:1034-1041, 2009
-
(2009)
Am J Kidney Dis
, vol.53
, pp. 1034-1041
-
-
Power, A.1
Duncan, N.2
Singh, S.K.3
Brown, W.4
Dalby, E.5
Edwards, C.6
Lynch, K.7
Prout, V.8
Cairns, T.9
Griffith, M.10
McLean, A.11
Palmer, A.12
Taube, D.13
-
36
-
-
79953204575
-
A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomised trial
-
Maki DG, Ash SR, Winger RK, Lavin P: A novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomised trial. Crit Care Med 39:613-620, 2011
-
(2011)
Crit Care Med
, vol.39
, pp. 613-620
-
-
Maki, D.G.1
Ash, S.R.2
Winger, R.K.3
Lavin, P.4
-
37
-
-
73449110151
-
Does heparin coating improve patency or reduce infection of tunneled dialysis catheters?
-
Jain G, Allon M, Saddekni S, Barker J-F, Maya ID: Does heparin coating improve patency or reduce infection of tunneled dialysis catheters? Clin J Am Soc Nephrol 4:1787-1790, 2009
-
(2009)
Clin J Am Soc Nephrol
, vol.4
, pp. 1787-1790
-
-
Jain, G.1
Allon, M.2
Saddekni, S.3
Barker, J.-F.4
Maya, I.D.5
|