메뉴 건너뛰기




Volumn 55, Issue 5, 2008, Pages 2770-2774

Pulsed Bias Voltage Shutdown to Suppress the Polarization Effect for a CdTe Radiation Detector

Author keywords

Energy resolution; polarization effect; pulsed bias voltage; semiconductor radiation detectors

Indexed keywords


EID: 84858332728     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/TNS.2008.2002079     Document Type: Article
Times cited : (10)

References (12)
  • 2
    • 0001442926 scopus 로고    scopus 로고
    • CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors
    • Y. Eisen and A. Shor, “CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors,” J. Cryst. Growth, vol. 184/185, pp. 1302–1312, 1998.
    • (1998) J. Cryst. Growth , vol.184-185 , pp. 1302-1312
    • Eisen, Y.1    Shor, A.2
  • 3
    • 84939368785 scopus 로고
    • Polarization in cadmium telluride nuclear radiation detectors
    • Feb.
    • P. Siffert, J. Berger, C. Scharager, A. Cornet, and R. Stuck, “Polarization in cadmium telluride nuclear radiation detectors,” IEEE Trans. Nucl. Sci., vol. NS-23, no. 1, pp. 159–170, Feb. 1976.
    • (1976) IEEE Trans. Nucl. Sci. , vol.NS-23 , Issue.1 , pp. 159-170
    • Siffert, P.1    Berger, J.2    Scharager, C.3    Cornet, A.4    Stuck, R.5
  • 5
    • 34548106567 scopus 로고    scopus 로고
    • Electric field properties of CdTe nuclear detectors
    • Aug.
    • A. Cola, I. Farella, A. M. Mancini, and A. Donati, “Electric field properties of CdTe nuclear detectors,” IEEE Trans. Nucl. Sci., vol. 54, no. 4, pp. 868–872, Aug. 2007.
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.4 , pp. 868-872
    • Cola, A.1    Farella, I.2    Mancini, A.M.3    Donati, A.4
  • 6
    • 0032096137 scopus 로고    scopus 로고
    • Performance of a new schottky CdTe detector for hard X-ray spectroscopy
    • Jun.
    • C. Matsumoto, T. Takahashi, K. Takizawa, R. Ohno, T. Ozaki, and K. Mori, “Performance of a new schottky CdTe detector for hard X-ray spectroscopy,” IEEE Trans. Nucl. Sci., vol. 45, no. 3, pp. 428–432, Jun. 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.3 , pp. 428-432
    • Matsumoto, C.1    Takahashi, T.2    Takizawa, K.3    Ohno, R.4    Ozaki, T.5    Mori, K.6
  • 8
    • 0016059854 scopus 로고
    • Time-dependent polarization of CdTe gamma-ray detectors
    • R. O. Bell, G. Entine, and H. B. Serreze, “Time-dependent polarization of CdTe gamma-ray detectors,” Nucl. Instrum. Methods, vol. 117, pp. 267–271, 1974.
    • (1974) Nucl. Instrum. Methods , vol.117 , pp. 267-271
    • Bell, R.O.1    Entine, G.2    Serreze, H.B.3
  • 9
    • 34548062258 scopus 로고    scopus 로고
    • CdTe detector characteristics at 30 C and 35 C when using the periodic bias reset technique
    • Aug.
    • T. Seino and I. Takahashi, “CdTe detector characteristics at 30 C and 35 C when using the periodic bias reset technique,” IEEE Trans. Nucl. Sci., vol. 54, no. 4, pp. 777–781, Aug. 2007.
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.4 , pp. 777-781
    • Seino, T.1    Takahashi, I.2
  • 10
    • 23844461529 scopus 로고    scopus 로고
    • Derivation of the input function from dynamic PET images with the HRRT
    • Rome, Italy
    • S. Baudrexel, R. Graf, C. Knoess, S. Vollmar, and K. Wienhard, “Derivation of the input function from dynamic PET images with the HRRT,” in Proc. IEEE NSS-MIC Conf. Rec., Rome, Italy, 2004, pp. 3890–3892.
    • (2004) Proc. IEEE NSS-MIC Conf. Rec. , pp. 3890-3892
    • Baudrexel, S.1    Graf, R.2    Knoess, C.3    Vollmar, S.4    Wienhard, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.