메뉴 건너뛰기




Volumn 163, Issue 3, 2012, Pages 492-499

Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation

Author keywords

[No Author keywords available]

Indexed keywords

AGED; ARTICLE; ATRIOVENTRICULAR BLOCK; CONSERVATIVE TREATMENT; FEMALE; HEART LEFT BUNDLE BRANCH BLOCK; HEART RIGHT BUNDLE BRANCH BLOCK; HOSPITALIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; PACEMAKER; PATIENT SAFETY; PRIORITY JOURNAL; SUDDEN DEATH; SURVIVAL RATE; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84858319998     PISSN: 00028703     EISSN: 10976744     Source Type: Journal    
DOI: 10.1016/j.ahj.2011.12.009     Document Type: Article
Times cited : (98)

References (21)
  • 1
    • 0037420076 scopus 로고    scopus 로고
    • Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery
    • B.A. Koplan, W.G. Stevenson, and L.M. Epstein Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery J Am Coll Cardiol 41 2003 795 801
    • (2003) J Am Coll Cardiol , vol.41 , pp. 795-801
    • Koplan, B.A.1    Stevenson, W.G.2    Epstein, L.M.3
  • 2
    • 33646229105 scopus 로고    scopus 로고
    • Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement
    • [discussion 216-17]
    • H.B. Erdogan, N. Kayalar, and H. Ardal Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement J Card Surg 21 2006 211 215 [discussion 216-17]
    • (2006) J Card Surg , vol.21 , pp. 211-215
    • Erdogan, H.B.1    Kayalar, N.2    Ardal, H.3
  • 3
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • A. Cribier, H. Eltchaninoff, and A. Bash Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description Circulation 106 2002 3006 3008
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 4
    • 28844467934 scopus 로고    scopus 로고
    • First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis
    • E. Grube, J.C. Laborde, and B. Zickmann First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis Catheter Cardiovasc Interv 66 2005 465 469
    • (2005) Catheter Cardiovasc Interv , vol.66 , pp. 465-469
    • Grube, E.1    Laborde, J.C.2    Zickmann, B.3
  • 5
    • 44949088496 scopus 로고    scopus 로고
    • Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve
    • N. Piazza, Y. Onuma, and E. Jesserun Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve JACC Cardiovasc Interv 1 2008 310 316
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 310-316
    • Piazza, N.1    Onuma, Y.2    Jesserun, E.3
  • 6
    • 78449261311 scopus 로고    scopus 로고
    • Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system
    • A.S. Petronio, M. De Carlo, and F. Bedogni Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system Circ Cardiovasc Interv 3 2010 359 366
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 359-366
    • Petronio, A.S.1    De Carlo, M.2    Bedogni, F.3
  • 7
    • 77955617014 scopus 로고    scopus 로고
    • Predictors for new-onset complete heart block after transcatheter aortic valve implantation
    • S. Bleiziffer, H. Ruge, and J. Horer Predictors for new-onset complete heart block after transcatheter aortic valve implantation JACC Cardiovasc Interv 3 2010 524 530
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 524-530
    • Bleiziffer, S.1    Ruge, H.2    Horer, J.3
  • 8
    • 78149452061 scopus 로고    scopus 로고
    • Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation
    • L. Roten, P. Wenaweser, and E. Delacretaz Incidence and predictors of atrioventricular conduction impairment after transcatheter aortic valve implantation Am J Cardiol 106 2010 1473 1480
    • (2010) Am J Cardiol , vol.106 , pp. 1473-1480
    • Roten, L.1    Wenaweser, P.2    Delacretaz, E.3
  • 9
    • 77955651417 scopus 로고    scopus 로고
    • "Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI
    • G. Latsios, U. Gerckens, and L. Buellesfeld "Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI Catheter Cardiovasc Interv 76 2010 431 439
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 431-439
    • Latsios, G.1    Gerckens, U.2    Buellesfeld, L.3
  • 10
    • 79952738239 scopus 로고    scopus 로고
    • Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: Incidence and contributing factors (the UK CoreValve Collaborative)
    • M.Z. Khawaja, R. Rajani, and A. Cook Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative) Circulation 123 2011 951 960
    • (2011) Circulation , vol.123 , pp. 951-960
    • Khawaja, M.Z.1    Rajani, R.2    Cook, A.3
  • 11
    • 78651506594 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: First results from a multi-centre real-world registry
    • R. Zahn, U. Gerckens, and E. Grube Transcatheter aortic valve implantation: first results from a multi-centre real-world registry Eur Heart J 32 2011 198 204
    • (2011) Eur Heart J , vol.32 , pp. 198-204
    • Zahn, R.1    Gerckens, U.2    Grube, E.3
  • 12
    • 64349084245 scopus 로고    scopus 로고
    • Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    • H. Jilaihawi, D. Chin, and M. Vasa-Nicotera Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis Am Heart J 157 2009 860 866
    • (2009) Am Heart J , vol.157 , pp. 860-866
    • Jilaihawi, H.1    Chin, D.2    Vasa-Nicotera, M.3
  • 13
    • 78349255551 scopus 로고    scopus 로고
    • Predictors for permanent pacing after transcatheter aortic valve implantation
    • P. Haworth, M. Behan, and M. Khawaja Predictors for permanent pacing after transcatheter aortic valve implantation Catheter Cardiovasc Interv 76 2010 751 756
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 751-756
    • Haworth, P.1    Behan, M.2    Khawaja, M.3
  • 14
    • 77649145354 scopus 로고    scopus 로고
    • Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis
    • J. Baan Jr., Z.Y. Yong, and K.T. Koch Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis Am Heart J 159 2010 497 503
    • (2010) Am Heart J , vol.159 , pp. 497-503
    • Baan, Jr.J.1    Yong, Z.Y.2    Koch, K.T.3
  • 15
    • 77955182912 scopus 로고    scopus 로고
    • Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation
    • D. Erkapic, W.K. Kim, and M. Weber Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation Europace 12 2010 1188 1190
    • (2010) Europace , vol.12 , pp. 1188-1190
    • Erkapic, D.1    Kim, W.K.2    Weber, M.3
  • 16
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, and A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 17
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • E. Grube, G. Schuler, and L. Buellesfeld Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome J Am Coll Cardiol 50 2007 69 76
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 18
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, and E. Nikolsky Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium Eur Heart J 32 2011 205 217
    • (2011) Eur Heart J , vol.32 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 19
    • 34548793595 scopus 로고    scopus 로고
    • Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association
    • P.E. Vardas, A. Auricchio, and J.J. Blanc Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in collaboration with the European Heart Rhythm Association Eur Heart J 28 2007 2256 2295
    • (2007) Eur Heart J , vol.28 , pp. 2256-2295
    • Vardas, P.E.1    Auricchio, A.2    Blanc, J.J.3
  • 20
    • 44949107393 scopus 로고    scopus 로고
    • Atrioventricular block after transcatheter balloon expandable aortic valve implantation
    • A. Sinhal, L. Altwegg, and S. Pasupati Atrioventricular block after transcatheter balloon expandable aortic valve implantation JACC Cardiovasc Interv 1 2008 305 309
    • (2008) JACC Cardiovasc Interv , vol.1 , pp. 305-309
    • Sinhal, A.1    Altwegg, L.2    Pasupati, S.3
  • 21
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • D. Himbert, F. Descoutures, and N. Al-Attar Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis J Am Coll Cardiol 54 2009 303 311
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al-Attar, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.