메뉴 건너뛰기




Volumn 46, Issue 1, 2012, Pages 75-80

Efficacy of high-energy collimator for sentinel node lymphoscintigraphy of early breast cancer patients

Author keywords

collimator; HEAP; high energy all purpose; LEHR; low energy high resolution; lymphoscintigraphy; sentinel node

Indexed keywords

TECHNETIUM SULFUR COLLOID TC 99M;

EID: 84858263121     PISSN: 13182099     EISSN: 15813207     Source Type: Journal    
DOI: 10.2478/v10019-012-0013-3     Document Type: Article
Times cited : (6)

References (18)
  • 1
    • 68949113489 scopus 로고    scopus 로고
    • Assessment the diagnostic accuracy of sentinel lymph nodes lymphoscintigraphy using Technetium-99m phytate in breast cancer
    • Eftekhari M, Beiki D, Fallahi B, Arabi M, Memari F, Gholamrezanezhad A, et al. Assessment the diagnostic accuracy of sentinel lymph nodes lymphoscintigraphy using Technetium-99m phytate in breast cancer. DARU J Pharm Sci 2009; 17: 83-7.
    • (2009) DARU J Pharm Sci , vol.17 , pp. 83-87
    • Eftekhari, M.1    Beiki, D.2    Fallahi, B.3    Arabi, M.4    Memari, F.5    Gholamrezanezhad, A.6
  • 2
    • 78649295305 scopus 로고    scopus 로고
    • Lymphedema following cancer therapy in Slovenia: A frequently overlooked condition?
    • Rucigaj TP, Leskovec NK, Zunter VT. Lymphedema following cancer therapy in Slovenia: a frequently overlooked condition? Radiol Oncol 2010; 44: 244-8.
    • (2010) Radiol Oncol , vol.44 , pp. 244-248
    • Rucigaj, T.P.1    Leskovec, N.K.2    Zunter, V.T.3
  • 5
    • 13644252419 scopus 로고    scopus 로고
    • Sentinel node detection in patients with breast cancer: Low-energy all-purpose collimator or medium-energy collimator?
    • DOI 10.1097/00003072-200410000-00001
    • Lemstra C, Broersma M, Poot L, Jager PL. Sentinel node detection in patients with breast cancer: low-energy all-purpose collimator or medium-energy collimator? Clin Nucl Med 2004; 29: 609-13. (Pubitemid 40228162)
    • (2004) Clinical Nuclear Medicine , vol.29 , Issue.10 , pp. 609-613
    • Lemstra, C.1    Broersma, M.2    Poot, L.3    Jager, P.L.4
  • 6
    • 84858188506 scopus 로고    scopus 로고
    • Detectability of sentinel nodes in lymphoscintigraphy as a function of collimator type and distance from the injection site: A phantom study
    • Nunez M, Alonso O, Mut F, Vila R, Beretta M, Illutton BF. Detectability of sentinel nodes in lymphoscintigraphy as a function of collimator type and distance from the injection site: A phantom study. J Nucl Med Technol 2004; 32: 105-6.
    • (2004) J Nucl Med Technol , vol.32 , pp. 105-106
    • Nunez, M.1    Alonso, O.2    Mut, F.3    Vila, R.4    Beretta, M.5    Illutton, B.F.6
  • 9
    • 17644377550 scopus 로고    scopus 로고
    • Sentinel node detection in patients with breast cancer: Low-energy all-purpose collimator or medium-energy collimator? (multiple letters)
    • DOI 10.1097/01.rlu.0000159913.08107.5b
    • Krynyckyi BR, Sata S, Zolty I, Kim DW, Kim SC, Knesaurek K. Sentinel node detection in patients with breast cancer: low-energy all-purpose collimator or medium-energy collimator? Clin Nucl Med 2005; 30: 369-70. (Pubitemid 40569800)
    • (2005) Clinical Nuclear Medicine , vol.30 , Issue.5 , pp. 369-370
    • Krynyckyi, B.R.1    Sata, S.2    Zolty, I.3    Dong, W.K.4    Suk, C.K.5    Knesaurek, K.6    Lemstra, C.7
  • 12
    • 84927960116 scopus 로고    scopus 로고
    • Website: Accessed on 1 June 2011
    • Design calculator. Nuclear Fields Website: http://www.nuclearfields.com/ collimators-design-calculator.htm. Accessed on 1 June 2011.
    • Design Calculator
  • 14
    • 77349110016 scopus 로고    scopus 로고
    • Factors affecting sentinel lymph node detection failure in breast cancer patients using intradermal injection of the tracer
    • Abdollahi A, Jangjoo A, Dabbagh Kakhki VR, Zakavi SR, Memar B, Forghani MN, et al. Factors affecting sentinel lymph node detection failure in breast cancer patients using intradermal injection of the tracer. Rev Esp Med Nucl 2010; 29: 73-7.
    • (2010) Rev Esp Med Nucl , vol.29 , pp. 73-77
    • Abdollahi, A.1    Jangjoo, A.2    Dabbagh Kakhki, V.R.3    Zakavi, S.R.4    Memar, B.5    Forghani, M.N.6
  • 15
    • 0036580189 scopus 로고    scopus 로고
    • Usefulness of imaging method without using lead plate for sentinel lymph node scintigraphy
    • Tsushima H, Yamanaga T, Shimonishi Y, Ochi H. Usefulness of imaging method without using lead plate for sentinel lymph node scintigraphy. Kaku Igaku 2002; 39: 161-9.
    • (2002) Kaku Igaku , vol.39 , pp. 161-169
    • Tsushima, H.1    Yamanaga, T.2    Shimonishi, Y.3    Ochi, H.4
  • 16
    • 0036923129 scopus 로고    scopus 로고
    • 99m sulphur colloid and blue-dye for detection of the sentinel lymph node in breast cancer
    • Jastrzebski T, Kopacz A, Lass P. Comparison of peritumoral and subareolar injection of Tc99m sulphur colloid and blue-dye for detection of the sentinel lymph node in breast cancer. Nucl Med Rev Cent East Eur 2002; 5: 159-61. (Pubitemid 36054678)
    • (2002) Nuclear Medicine Review , vol.5 , Issue.2 , pp. 159-161
    • Jastrzebski, T.1    Kopacz, A.2    Lass, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.