메뉴 건너뛰기




Volumn 34, Issue 3, 2006, Pages 153-159

Usefulness of medium-energy collimator for sentinel node lymphoscintigraphy imaging in breast cancer patients

Author keywords

Breast cancer; Lymphoscintigraphy; Medium energy collimator; Sentinel lymph node; Star shaped artifacts

Indexed keywords

PERTECHNETIC ACID TC 99M;

EID: 33947635980     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (17)
  • 2
    • 0033977366 scopus 로고    scopus 로고
    • The concept of sentinel node localization: How it started
    • Morton DL, Chan AD. The concept of sentinel node localization: how it started. Semin Nucl Med. 2000;30:4-10.
    • (2000) Semin Nucl Med , vol.30 , pp. 4-10
    • Morton, D.L.1    Chan, A.D.2
  • 3
    • 0033966645 scopus 로고    scopus 로고
    • Sentinel node staging of early breast cancer using lymphoscintigraphy and the intraoperative gamma-detecting probe
    • Alazraki NP, Styblo T, Grant SF, Cohen S, Larsen T, Aarsvold JN. Sentinel node staging of early breast cancer using lymphoscintigraphy and the intraoperative gamma-detecting probe. Semin Nucl Med. 2000;30:56-64.
    • (2000) Semin Nucl Med , vol.30 , pp. 56-64
    • Alazraki, N.P.1    Styblo, T.2    Grant, S.F.3    Cohen, S.4    Larsen, T.5    Aarsvold, J.N.6
  • 5
    • 0041341832 scopus 로고    scopus 로고
    • Lymphatic mapping in patients with breast carcinoma: Reproducibility of lymphoscintigraphic results
    • Tanis PJ, Valdes Olmos RA, Muller SH, Nieweg OE. Lymphatic mapping in patients with breast carcinoma: reproducibility of lymphoscintigraphic results. Radiology. 2003;228:546-551.
    • (2003) Radiology , vol.228 , pp. 546-551
    • Tanis, P.J.1    Valdes Olmos, R.A.2    Muller, S.H.3    Nieweg, O.E.4
  • 6
    • 0032407347 scopus 로고    scopus 로고
    • Lymphoscintigraphy and radioguided biopsy of the sentinel axillary node in breast cancer
    • De Cicco C, Cremonesi M, Luini A, et al. Lymphoscintigraphy and radioguided biopsy of the sentinel axillary node in breast cancer. J Nucl Med. 1998;39: 2080-2084.
    • (1998) J Nucl Med , vol.39 , pp. 2080-2084
    • De Cicco, C.1    Cremonesi, M.2    Luini, A.3
  • 7
    • 0035023033 scopus 로고    scopus 로고
    • Summary of the second international sentinel node conference
    • Nieweg OE, Tanis PJ, Rutgers EJT. Summary of the second international sentinel node conference. Eur J Nucl Med. 2001;28:646-649.
    • (2001) Eur J Nucl Med , vol.28 , pp. 646-649
    • Nieweg, O.E.1    Tanis, P.J.2    Rutgers, E.J.T.3
  • 8
    • 0034894472 scopus 로고    scopus 로고
    • Radioguided sentinel lymph node biopsy in breast cancer surgery
    • Mariani G, Moresco L, Viale G, et al. Radioguided sentinel lymph node biopsy in breast cancer surgery. J Nucl Med. 2001;42:1198-1215.
    • (2001) J Nucl Med , vol.42 , pp. 1198-1215
    • Mariani, G.1    Moresco, L.2    Viale, G.3
  • 9
    • 1642328446 scopus 로고    scopus 로고
    • Periareolar injection for localization of sentinel nodes in breast cancer patients
    • Ellis RL, Seifert PJ, Neal CE, et al. Periareolar injection for localization of sentinel nodes in breast cancer patients. Breast J. 2004;10:94-100.
    • (2004) Breast J , vol.10 , pp. 94-100
    • Ellis, R.L.1    Seifert, P.J.2    Neal, C.E.3
  • 10
    • 13444302482 scopus 로고    scopus 로고
    • Improved detection of axillary hot nodes in lymphoscintigraphy in breast cancer located in the upper lateral quadrant with additional projection imaging
    • Koizumi M, Nomura E, Yamada Y, et al. Improved detection of axillary hot nodes in lymphoscintigraphy in breast cancer located in the upper lateral quadrant with additional projection imaging. Ann Nucl Med. 2004;18:707-710.
    • (2004) Ann Nucl Med , vol.18 , pp. 707-710
    • Koizumi, M.1    Nomura, E.2    Yamada, Y.3
  • 11
    • 0032993399 scopus 로고    scopus 로고
    • Technical aspects of sentinel node lymphoscintigraphy for breast cancer
    • Dunnwald LK, Mankoff DA, Byrd DR, et al. Technical aspects of sentinel node lymphoscintigraphy for breast cancer. J Nucl Med Technol. 1999;27:106-111.
    • (1999) J Nucl Med Technol , vol.27 , pp. 106-111
    • Dunnwald, L.K.1    Mankoff, D.A.2    Byrd, D.R.3
  • 13
    • 0033659553 scopus 로고    scopus 로고
    • Technical aspects of performing lymphoscintigraphy: Optimization of methods used to obtain images
    • Krynyckyi BR, Miner M, Ragonese JM, Firestone M, Kim CK, Machac J. Technical aspects of performing lymphoscintigraphy: optimization of methods used to obtain images. Clin Nucl Med. 2000;25:978-985.
    • (2000) Clin Nucl Med , vol.25 , pp. 978-985
    • Krynyckyi, B.R.1    Miner, M.2    Ragonese, J.M.3    Firestone, M.4    Kim, C.K.5    Machac, J.6
  • 14
    • 0033778999 scopus 로고    scopus 로고
    • Factors affecting sentinel node localization during preoperative breast lymphoscintigraphy
    • Haigh PI, Hansen NM, Giuliano AE, Edwards GK, Ye W, Glass EC. Factors affecting sentinel node localization during preoperative breast lymphoscintigraphy. J Nucl Med. 2000;41:1682-1688.
    • (2000) J Nucl Med , vol.41 , pp. 1682-1688
    • Haigh, P.I.1    Hansen, N.M.2    Giuliano, A.E.3    Edwards, G.K.4    Ye, W.5    Glass, E.C.6
  • 15
    • 13644252419 scopus 로고    scopus 로고
    • Sentinel node detection in patients with breast cancer: Low-energy all-purpose collimator or medium-energy collimator?
    • Lemstra C, Broersma M, Poot L, et al. Sentinel node detection in patients with breast cancer: low-energy all-purpose collimator or medium-energy collimator? Clin Nucl Med. 2004;29:609-613.
    • (2004) Clin Nucl Med , vol.29 , pp. 609-613
    • Lemstra, C.1    Broersma, M.2    Poot, L.3
  • 16
    • 0036580189 scopus 로고    scopus 로고
    • Usefulness of imaging method without using lead plate for sentinel lymph node scintigraphy [in Japanese]
    • Tsushima H, Yamanaga T, Shimonishi Y, Ochi H. Usefulness of imaging method without using lead plate for sentinel lymph node scintigraphy [in Japanese]. Kaku Igaku. 2002;39:161-169.
    • (2002) Kaku Igaku , vol.39 , pp. 161-169
    • Tsushima, H.1    Yamanaga, T.2    Shimonishi, Y.3    Ochi, H.4
  • 17
    • 17644377550 scopus 로고    scopus 로고
    • Sentinel node detection in patients with breast cancer: Low-energy all-purpose collimator or medium-energy collimator?
    • Krynyckyi BR, Sata S, Zolty I, Kim DW, Kim SC, Knesaurek K. Sentinel node detection in patients with breast cancer: low-energy all-purpose collimator or medium-energy collimator? Clin Nucl Med. 2005;30: 369-370.
    • (2005) Clin Nucl Med , vol.30 , pp. 369-370
    • Krynyckyi, B.R.1    Sata, S.2    Zolty, I.3    Kim, D.W.4    Kim, S.C.5    Knesaurek, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.