Volumn 83, Issue 4, 2012, Pages 500-504

The use of dual accelerometers improves measurement of chest compression depth

Author keywords

Accelerometer; Compression depth; CPR; Feedback

Indexed keywords

ACCELERATION; ACCELEROMETER; ACCURACY; ARTICLE; AUDIOVISUAL EQUIPMENT; BED; CHEST COMPRESSION DEPTH; COMPRESSION; MEASUREMENT; PRIORITY JOURNAL; RESUSCITATION; SIGNAL PROCESSING; STERNUM;

EID: 84858073719     PISSN: 03009572     EISSN: 18731570     Source Type: Journal    
DOI: 10.1016/j.resuscitation.2011.09.028     Document Type: Article
Times cited : (44)

References (17)
  • 1
    • 0021364531 scopus 로고
    • Coronary blood flow during cardiopulmonary resuscitation in swine
    • Bellamy R.F., Deguzman L.R., Pedersen D.C. Coronary blood flow during cardiopulmonary resuscitation in swine. Circulation 1984, 69:174-180.
    • (1984) Circulation , vol.69 , pp. 174-180
    • Bellamy, R.F.1    Deguzman, L.R.2    Pedersen, D.C.3
  • 2
    • 28544432407 scopus 로고    scopus 로고
    • European resuscitation council guidelines for resuscitation 2005 section 2. Adult basic life support and use of automated external defibrillators
    • p. S1, S7-23
    • Hardley A.J., Koster R., Monsieurs K., Perkins G.D., Davies S., Bossaert L. European resuscitation council guidelines for resuscitation 2005 section 2. Adult basic life support and use of automated external defibrillators. Resuscitation 2005, 67. p. S1, S7-23.
    • (2005) Resuscitation , vol.67
    • Hardley, A.J.1    Koster, R.2    Monsieurs, K.3    Perkins, G.D.4    Davies, S.5    Bossaert, L.6
  • 3
    • 12244267087 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during in hospital cardiac arrest
    • Abella B.S., Alvarado J.P., Myklebust H., et al. Quality of cardiopulmonary resuscitation during in hospital cardiac arrest. JAMA 2005, 293:305-310.
    • (2005) JAMA , vol.293 , pp. 305-310
    • Abella, B.S.1    Alvarado, J.P.2    Myklebust, H.3
  • 4
    • 12244295495 scopus 로고    scopus 로고
    • Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest
    • Wik L., Kramer-Johanson J., Myklebust H., et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA 2005, 293:299-304.
    • (2005) JAMA , vol.293 , pp. 299-304
    • Wik, L.1    Kramer-Johanson, J.2    Myklebust, H.3
  • 5
    • 11144332045 scopus 로고    scopus 로고
    • CPREzy: an evaluation during simulated cardiac arrest on a hospital bed
    • Perkins G.D., Augre C., Rogers H., Allan M., Thickett D.R. CPREzy: an evaluation during simulated cardiac arrest on a hospital bed. Resuscitation 2005, 64:103-108.
    • (2005) Resuscitation , vol.64 , pp. 103-108
    • Perkins, G.D.1    Augre, C.2    Rogers, H.3    Allan, M.4    Thickett, D.R.5
  • 6
    • 72049110223 scopus 로고    scopus 로고
    • New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest
    • Skorning M., Beckers S.K., Brokmann J.C., et al. New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest. Resuscitation 2010, 81:53-58.
    • (2010) Resuscitation , vol.81 , pp. 53-58
    • Skorning, M.1    Beckers, S.K.2    Brokmann, J.C.3
  • 8
    • 0035189805 scopus 로고    scopus 로고
    • The effect of differing support surfaces on the efficacy of chest compressions using a resuscitation manikin model
    • Tweed M., Tweed C., Perkins G.D. The effect of differing support surfaces on the efficacy of chest compressions using a resuscitation manikin model. Resuscitation 2001, 51:179-183.
    • (2001) Resuscitation , vol.51 , pp. 179-183
    • Tweed, M.1    Tweed, C.2    Perkins, G.D.3
  • 9
    • 68049119268 scopus 로고    scopus 로고
    • American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 2. Adult basic life support
    • (III-5-16)
    • American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 2. Adult basic life support. Circulation 2005, 112. (III-5-16).
    • (2005) Circulation , vol.112
  • 10
    • 57649240448 scopus 로고    scopus 로고
    • Compression feedback devices overestimate chest compression depth when performed on a bed
    • Perkins G.D., Kocierz L., Smith S.C., McCulloch R.A., Davies R.P. Compression feedback devices overestimate chest compression depth when performed on a bed. Resuscitation 2009, 80:79-82.
    • (2009) Resuscitation , vol.80 , pp. 79-82
    • Perkins, G.D.1    Kocierz, L.2    Smith, S.C.3    McCulloch, R.A.4    Davies, R.P.5
  • 11
    • 67349185558 scopus 로고    scopus 로고
    • Effect of mattress deflection on CPR quality assessment for older children and adolescents
    • Nishisaki A., Nysaether J., Sutton R., et al. Effect of mattress deflection on CPR quality assessment for older children and adolescents. Resuscitation 2009, 80:540-545.
    • (2009) Resuscitation , vol.80 , pp. 540-545
    • Nishisaki, A.1    Nysaether, J.2    Sutton, R.3
  • 12
    • 0036172471 scopus 로고    scopus 로고
    • Compression depth estimation for CPR quality assessment using DSP on accelerometer signals
    • Aase S., Myklebust H. Compression depth estimation for CPR quality assessment using DSP on accelerometer signals. IEEE Trans Biomed Eng 2002, 49:263-268.
    • (2002) IEEE Trans Biomed Eng , vol.49 , pp. 263-268
    • Aase, S.1    Myklebust, H.2
  • 13
    • 84858069552 scopus 로고    scopus 로고
    • Implementing positioning algorithms using accelerometers. Free Scale Semiconductor Application Note, AN3397
    • Seifert K, Camacho O. Implementing positioning algorithms using accelerometers. Free Scale Semiconductor Application Note, AN3397 http://www.freescale.com/support.
    • Seifert, K.1    Camacho, O.2
  • 14
    • 78349261145 scopus 로고    scopus 로고
    • American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 5. Adult basic life support
    • American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Part 5. Adult basic life support. Circulation 2010, 122:S685-S705.
    • (2010) Circulation , vol.122
  • 15
    • 33751254313 scopus 로고    scopus 로고
    • Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback; a prospective interventional study
    • Kramer-Johanson J., Myklebust H., Wik L., et al. Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback; a prospective interventional study. Resuscitation 2006, 71:283-292.
    • (2006) Resuscitation , vol.71 , pp. 283-292
    • Kramer-Johanson, J.1    Myklebust, H.2    Wik, L.3
  • 16
    • 34250338449 scopus 로고    scopus 로고
    • Increasing compression depth during manikin CPR using a simple backboard
    • Andersen L.O., Isbye D.L., Rasmussen L.S. Increasing compression depth during manikin CPR using a simple backboard. Acta Anaesthesiol Scand 2007, 51:747-750.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 747-750
    • Andersen, L.O.1    Isbye, D.L.2    Rasmussen, L.S.3
  • 17
    • 84858074955 scopus 로고    scopus 로고
    • Novel smart backboard improves CPR performance
    • 81S: S11
    • Perkins G.D., Fossan H., Field R., et al. Novel smart backboard improves CPR performance. Resuscitation 2010, 81S: S11.
    • (2010) Resuscitation
    • Perkins, G.D.1    Fossan, H.2    Field, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.