메뉴 건너뛰기




Volumn 14, Issue 3, 2012, Pages 139-143

Techniques for Self-Measurement of Blood Pressure: Limitations and Needs for Future Research

Author keywords

[No Author keywords available]

Indexed keywords

ANTIHYPERTENSIVE AGENT;

EID: 84857640629     PISSN: 15246175     EISSN: 17517176     Source Type: Journal    
DOI: 10.1111/j.1751-7176.2011.00586.x     Document Type: Note
Times cited : (22)

References (30)
  • 1
    • 12444277817 scopus 로고    scopus 로고
    • European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement
    • et al; on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring
    • O'Brien E, Asmar R, Beilin L, et al; on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens. 2003;21:821-848.
    • (2003) J Hypertens , vol.21 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3
  • 2
    • 0023839194 scopus 로고
    • How common is white coat hypertension?
    • Pickering TG, James GD, Boddie C, et al. How common is white coat hypertension? JAMA. 1988;259:255-258.
    • (1988) JAMA , vol.259 , pp. 255-258
    • Pickering, T.G.1    James, G.D.2    Boddie, C.3
  • 3
    • 0035527547 scopus 로고    scopus 로고
    • Reliability of ambulatory blood pressure monitoring
    • Palatini P. Reliability of ambulatory blood pressure monitoring. Blood Press Monit. 2001;6:291-295.
    • (2001) Blood Press Monit , vol.6 , pp. 291-295
    • Palatini, P.1
  • 4
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • et al; Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • Pickering TG, Hall JE, Appel LJ, et al; Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45:142-161.
    • (2005) Hypertension. , vol.45 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3
  • 5
    • 83655161390 scopus 로고    scopus 로고
    • Ambulatory and home blood pressure measurement: complementary rather than competitive methods
    • Palatini P. Ambulatory and home blood pressure measurement: complementary rather than competitive methods. Hypertension. 2012;59:2-4.
    • (2012) Hypertension. , vol.59 , pp. 2-4
    • Palatini, P.1
  • 6
    • 51549098043 scopus 로고    scopus 로고
    • European society of hypertension guidelines for blood pressure monitoring at home: a summary report of the second international consensus conference on home blood pressure monitoring
    • et al; ESH Working Group on Blood Pressure Monitoring
    • Parati G, Stergiou GS, Asmar R, et al; ESH Working Group on Blood Pressure Monitoring. European society of hypertension guidelines for blood pressure monitoring at home: a summary report of the second international consensus conference on home blood pressure monitoring. J Hypertens. 2008;26:1505-1526.
    • (2008) J Hypertens , vol.26 , pp. 1505-1526
    • Parati, G.1    Stergiou, G.S.2    Asmar, R.3
  • 7
    • 0034892295 scopus 로고    scopus 로고
    • Rapid oscillometric blood pressure measurement compared to conventional ocillometric measurement
    • Yarows AS, Patel K, Brook R. Rapid oscillometric blood pressure measurement compared to conventional ocillometric measurement. Blood Press Monit. 2001;6:145-147.
    • (2001) Blood Press Monit. , vol.6 , pp. 145-147
    • Yarows, A.S.1    Patel, K.2    Brook, R.3
  • 10
    • 0027218269 scopus 로고
    • The British Hypertension Society protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Littler WA, et al. The British Hypertension Society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11(suppl 2):S43-S63.
    • (1993) J Hypertens , vol.11 , Issue.SUPPL. 2
    • O'Brien, E.1    Petrie, J.2    Littler, W.A.3
  • 11
    • 0035992025 scopus 로고    scopus 로고
    • European Society of Hypertension international protocol for validation of blood pressure measuring devices in adults
    • et al; Working Group on Blood Pressure Monitoring of the European Society of Hypertension
    • O'Brien E, Pickering T, Asmar R, et al; Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension international protocol for validation of blood pressure measuring devices in adults. Blood Press Monit. 2002;7:3-17.
    • (2002) Blood Press Monit. , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3
  • 12
    • 76449087188 scopus 로고    scopus 로고
    • European Society of Hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults
    • et al; on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension
    • O'Brien E, Atkins N, Stergiou G, et al; on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15:23-38.
    • (2010) Blood Press Monit. , vol.15 , pp. 23-38
    • O'Brien, E.1    Atkins, N.2    Stergiou, G.3
  • 13
    • 53549116740 scopus 로고    scopus 로고
    • PA.NET international quality certification protocol for blood pressure monitors
    • Omboni S, Costantini C, Pini C, et al. PA.NET international quality certification protocol for blood pressure monitors. Blood Press Monit. 2008;13:285-289.
    • (2008) Blood Press Monit. , vol.13 , pp. 285-289
    • Omboni, S.1    Costantini, C.2    Pini, C.3
  • 14
    • 0032430927 scopus 로고    scopus 로고
    • Reliability of reporting self-measured blood pressure values by hypertensives patients
    • Mengden T, Hernandez Medina RM, Beltran B, et al. Reliability of reporting self-measured blood pressure values by hypertensives patients. Am J Hypertens. 1998;11:1413-1417.
    • (1998) Am J Hypertens , vol.11 , pp. 1413-1417
    • Mengden, T.1    Hernandez Medina, R.M.2    Beltran, B.3
  • 15
    • 57449092072 scopus 로고    scopus 로고
    • Day-by-day variability of blood pressure and heart rate at home as a novel predictor of prognosis: the Ohasama study
    • Kikuya M, Ohkubo T, Metoki H, et al. Day-by-day variability of blood pressure and heart rate at home as a novel predictor of prognosis: the Ohasama study. Hypertension. 2008;52:1045-1050.
    • (2008) Hypertension. , vol.52 , pp. 1045-1050
    • Kikuya, M.1    Ohkubo, T.2    Metoki, H.3
  • 16
    • 67649647666 scopus 로고    scopus 로고
    • Association between the morning-evening difference in home blood pressure and cardiac damage in untreated hypertensive patients
    • Matsui Y, Eguchi K, Shibasaki S, et al. Association between the morning-evening difference in home blood pressure and cardiac damage in untreated hypertensive patients. J Hypertens. 2009;27:712-720.
    • (2009) J Hypertens , vol.27 , pp. 712-720
    • Matsui, Y.1    Eguchi, K.2    Shibasaki, S.3
  • 17
    • 33947175152 scopus 로고    scopus 로고
    • A tool for reliable self-home blood pressure monitoring designed according to the European Society of Hypertension recommendations: the Microlife WatchBP Home monitor
    • Stergiou GS, Giovas PP, Gkinos CP, et al. A tool for reliable self-home blood pressure monitoring designed according to the European Society of Hypertension recommendations: the Microlife WatchBP Home monitor. Blood Press Monit. 2007;12:127-131.
    • (2007) Blood Press Monit. , vol.12 , pp. 127-131
    • Stergiou, G.S.1    Giovas, P.P.2    Gkinos, C.P.3
  • 18
    • 0029831681 scopus 로고    scopus 로고
    • A century of confusion: which bladder for accurate blood pressure measurement?
    • review
    • O'Brien E. A century of confusion: which bladder for accurate blood pressure measurement? [review]. J Hum Hypertens. 1996;10:565-572.
    • (1996) J Hum Hypertens , vol.10 , pp. 565-572
    • O'Brien, E.1
  • 19
    • 79951662140 scopus 로고    scopus 로고
    • Blood pressure measurement in very obese patients: a challenging problem
    • Palatini P, Parati G. Blood pressure measurement in very obese patients: a challenging problem. J Hypertens. 2011;29:425-429.
    • (2011) J Hypertens , vol.29 , pp. 425-429
    • Palatini, P.1    Parati, G.2
  • 20
    • 0033845223 scopus 로고    scopus 로고
    • Cuff width and accuracy of measurement of blood pressure
    • Alpert BS. Cuff width and accuracy of measurement of blood pressure. Blood Press Monit. 2000;5:151-152.
    • (2000) Blood Press Monit. , vol.5 , pp. 151-152
    • Alpert, B.S.1
  • 21
    • 0020061643 scopus 로고
    • Reliability of blood pressure measurement on fat upper arms
    • Huige MC. Reliability of blood pressure measurement on fat upper arms. Ther Umsch. 1982;39:87-91.
    • (1982) Ther Umsch , vol.39 , pp. 87-91
    • Huige, M.C.1
  • 22
    • 0022363509 scopus 로고
    • Comparison of the conical cuff and the standard rectangular cuffs
    • Maxwell GF, Pruijt JF, Arntzenius AC. Comparison of the conical cuff and the standard rectangular cuffs. Int J Epidemiol. 1985;14:468-472.
    • (1985) Int J Epidemiol , vol.14 , pp. 468-472
    • Maxwell, G.F.1    Pruijt, J.F.2    Arntzenius, A.C.3
  • 23
    • 79957944591 scopus 로고    scopus 로고
    • Postanesthesia patients with large upper arm circumference: is use of an "extra-long" adult cuff or forearm cuff placement accurate?
    • Watson S, Aguas M, Bienapfl T, et al. Postanesthesia patients with large upper arm circumference: is use of an "extra-long" adult cuff or forearm cuff placement accurate? J Perianesth Nurs. 2011;26:135-142.
    • (2011) J Perianesth Nurs. , vol.26 , pp. 135-142
    • Watson, S.1    Aguas, M.2    Bienapfl, T.3
  • 24
    • 85084923215 scopus 로고    scopus 로고
    • Rectangular cuffs may overestimate blood pressure in subjects with large conical arms
    • In press
    • Palatini P, Benetti E, Fania C, et al. Rectangular cuffs may overestimate blood pressure in subjects with large conical arms. J Hypertens. In press.
    • J Hypertens
    • Palatini, P.1    Benetti, E.2    Fania, C.3
  • 25
    • 79951659479 scopus 로고    scopus 로고
    • What to do when faced with an unmeasurable ambulatory blood pressure?
    • O'Brien E. What to do when faced with an unmeasurable ambulatory blood pressure? J Hypertens. 2011;29:451-453.
    • (2011) J Hypertens , vol.29 , pp. 451-453
    • O'Brien, E.1
  • 26
    • 70349731878 scopus 로고    scopus 로고
    • Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences
    • Bonso E, Dorigatti F, Palatini P. Accuracy of the BP A100 blood pressure measuring device coupled with a single cuff with standard-size bladder over a wide range of arm circumferences. Blood Press Monit. 2009;14:216-219.
    • (2009) Blood Press Monit. , vol.14 , pp. 216-219
    • Bonso, E.1    Dorigatti, F.2    Palatini, P.3
  • 27
    • 54249108866 scopus 로고    scopus 로고
    • Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring
    • Stergiou GS, Tzamouranis D, Nasothimiou EG, et al. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring J Hum Hypertens. 2008;22:796-800.
    • (2008) J Hum Hypertens , vol.22 , pp. 796-800
    • Stergiou, G.S.1    Tzamouranis, D.2    Nasothimiou, E.G.3
  • 28
    • 78149341709 scopus 로고    scopus 로고
    • Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences
    • Bonso E, Saladini F, Zanier A, et al. Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertens Res. 2010;33:1186-1191.
    • (2010) Hypertens Res , vol.33 , pp. 1186-1191
    • Bonso, E.1    Saladini, F.2    Zanier, A.3
  • 29
    • 82755193753 scopus 로고    scopus 로고
    • Effect of tissue mechanical properties on cuff-based blood pressure measurements
    • Lan H, Al-Jumaily AM, Lowe A, et al. Effect of tissue mechanical properties on cuff-based blood pressure measurements. Med Eng Phys. 2011;33:1287-1292.
    • (2011) Med Eng Phys , vol.33 , pp. 1287-1292
    • Lan, H.1    Al-Jumaily, A.M.2    Lowe, A.3
  • 30


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.