Volumn 12, Issue 2, 2007, Pages 127-131

A tool for reliable self-home blood pressure monitoring designed according to the European Society of Hypertension recommendations: The Microlife WatchBP Home monitor

Author keywords

Blood pressure measurement; European Society of Hypertension; Home blood pressure; Hypertension; Microlife; Self measurement

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD PRESSURE MONITORING; CONTROLLED STUDY; FEMALE; HOME MONITORING; HUMAN; HYPERTENSION; MALE; OSCILLOMETRY; PILOT STUDY; PRIORITY JOURNAL; RELIABILITY; SELF MONITORING; SPHYGMOMANOMETER;

EID: 33947175152     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBP.0b013e32809efa38     Document Type: Article
Times cited : (18)

References (29)
  • 1
    • 12444277817 scopus 로고    scopus 로고
    • on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European Society of Hypertension Recommendations for Conventional, Ambulatory and Home Blood Pressure Measurement
    • O'Brien E, Asmar R, Beilin L, Imai Y, Mancia G, Mengden T, et al., on behalf of the European Society of Hypertension Working Group on Blood Pressure Monitoring. European Society of Hypertension Recommendations for Conventional, Ambulatory and Home Blood Pressure Measurement. J Hypertens 2003; 21:821-848.
    • (2003) J Hypertens , vol.21 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3    Imai, Y.4    Mancia, G.5    Mengden, T.6
  • 2
    • 0038556740 scopus 로고    scopus 로고
    • Self measured and ambulatory blood pressure in assessing the white-coat phenomenon
    • Parati G, Stergiou G. Self measured and ambulatory blood pressure in assessing the white-coat phenomenon. J Hypertens 2003; 21:677-682.
    • (2003) J Hypertens , vol.21 , pp. 677-682
    • Parati, G.1    Stergiou, G.2
  • 3
    • 0032126006 scopus 로고    scopus 로고
    • White coat effect detected using self-monitoring of blood pressure at home: Comparison with ambulatory blood pressure
    • Stergiou GS, Zourbaki AS, Skeva II, Mountokalakis TD. White coat effect detected using self-monitoring of blood pressure at home: comparison with ambulatory blood pressure. Am J Hypertens 1998; 11:820-827.
    • (1998) Am J Hypertens , vol.11 , pp. 820-827
    • Stergiou, G.S.1    Zourbaki, A.S.2    Skeva, I.I.3    Mountokalakis, T.D.4
  • 4
    • 1642493775 scopus 로고    scopus 로고
    • White coat effect in treated versus untreated hypertensives: A case-control study using ambulatory and home blood pressure monitoring
    • Stergiou GS, Efstathiou SP, Argyraki C, Roussias L, Mountokalakis T. White coat effect in treated versus untreated hypertensives: a case-control study using ambulatory and home blood pressure monitoring. Am J Hypertens 2004; 17:124-128.
    • (2004) Am J Hypertens , vol.17 , pp. 124-128
    • Stergiou, G.S.1    Efstathiou, S.P.2    Argyraki, C.3    Roussias, L.4    Mountokalakis, T.5
  • 5
    • 19744364255 scopus 로고    scopus 로고
    • Masked hypertension assessed by ambulatory or self-home blood pressure monitoring: Is it the same phenomenon?
    • Stergiou GS, Salgami E, Tzamouranis D, Roussias L. Masked hypertension assessed by ambulatory or self-home blood pressure monitoring: is it the same phenomenon? Am J Hypertens 2005; 18:772-778.
    • (2005) Am J Hypertens , vol.18 , pp. 772-778
    • Stergiou, G.S.1    Salgami, E.2    Tzamouranis, D.3    Roussias, L.4
  • 6
    • 1542401212 scopus 로고    scopus 로고
    • Cardiovascular prognosis of 'masked hypertension' detected by blood pressure self-measurement in elderly treated hypertensive patients
    • Bobrie G, Chatellier G, Genes N, Clerson P, Vaur L, Vaisse B, et al. Cardiovascular prognosis of 'masked hypertension' detected by blood pressure self-measurement in elderly treated hypertensive patients. JAMA 2004; 291:1342-1349.
    • (2004) JAMA , vol.291 , pp. 1342-1349
    • Bobrie, G.1    Chatellier, G.2    Genes, N.3    Clerson, P.4    Vaur, L.5    Vaisse, B.6
  • 7
    • 0036178676 scopus 로고    scopus 로고
    • Reproducibility of clinic, ambulatory and home blood pressure: Implications on the design of trials for the assessment of the efficacy of antihypertensive drugs
    • Stergiou GS, Baibas NM, Gantzarou AP, Skeva II, Kalkana CB, Roussias LG, et al. Reproducibility of clinic, ambulatory and home blood pressure: implications on the design of trials for the assessment of the efficacy of antihypertensive drugs. Am J Hypertens 2002; 15:101-104.
    • (2002) Am J Hypertens , vol.15 , pp. 101-104
    • Stergiou, G.S.1    Baibas, N.M.2    Gantzarou, A.P.3    Skeva, I.I.4    Kalkana, C.B.5    Roussias, L.G.6
  • 8
    • 0036109721 scopus 로고    scopus 로고
    • Value of home blood pressures as predictor of target organ damage in mild arterial hypertension
    • Mule G, Caimi G, Cottone S, Nardi E, Andronico G, Piazza G, et al. Value of home blood pressures as predictor of target organ damage in mild arterial hypertension. J Cardiovasc Risk 2002; 9:123-129.
    • (2002) J Cardiovasc Risk , vol.9 , pp. 123-129
    • Mule, G.1    Caimi, G.2    Cottone, S.3    Nardi, E.4    Andronico, G.5    Piazza, G.6
  • 9
    • 0036233338 scopus 로고    scopus 로고
    • Relationship between home blood pressure and longitudinal changes in target organ damage in treated hypertensive patients
    • Tsunoda S, Kawano Y, Horio T, Okuda N, Takishita S. Relationship between home blood pressure and longitudinal changes in target organ damage in treated hypertensive patients. Hypertens Res 2002; 25:167-173.
    • (2002) Hypertens Res , vol.25 , pp. 167-173
    • Tsunoda, S.1    Kawano, Y.2    Horio, T.3    Okuda, N.4    Takishita, S.5
  • 10
    • 33746151926 scopus 로고    scopus 로고
    • MAPA Working Group. Home blood pressure in poorly controlled hypertension: Relationship with ambulatory blood pressure and organ damage
    • Martinez MA, Sancho T, Garcia P, Moreno P, Rubio JM, Palau FJ, et al. MAPA Working Group. Home blood pressure in poorly controlled hypertension: relationship with ambulatory blood pressure and organ damage. Blood Press Monit 2006; 11:207-213.
    • (2006) Blood Press Monit , vol.11 , pp. 207-213
    • Martinez, M.A.1    Sancho, T.2    Garcia, P.3    Moreno, P.4    Rubio, J.M.5    Palau, F.J.6
  • 12
    • 12644257594 scopus 로고    scopus 로고
    • Proposal of reference values for home blood pressure measurement: Prognostic criteria based on a prospective observation of the general population in Ohasama, Japan
    • Tsuji I, Imai Y, Nagai K, Ohkubo T,Watanabe N, Minami N, et al. Proposal of reference values for home blood pressure measurement: prognostic criteria based on a prospective observation of the general population in Ohasama, Japan. Am J Hypertens 1997; 10:409-418.
    • (1997) Am J Hypertens , vol.10 , pp. 409-418
    • Tsuji, I.1    Imai, Y.2    Nagai, K.3    Ohkubo, T.4    Watanabe, N.5    Minami, N.6
  • 13
    • 17144375670 scopus 로고    scopus 로고
    • Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population: Follow-up results from the Pressioni Arteriose Monitorate e Loro Associazioni (PAMELA) study
    • Sega R, Facchetti R, Bombelli M, Cesana G, Corrao G, Grassi G, et al. Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population: follow-up results from the Pressioni Arteriose Monitorate e Loro Associazioni (PAMELA) study. Circulation 2005; 111:1777-1783.
    • (2005) Circulation , vol.111 , pp. 1777-1783
    • Sega, R.1    Facchetti, R.2    Bombelli, M.3    Cesana, G.4    Corrao, G.5    Grassi, G.6
  • 14
    • 33947182499 scopus 로고    scopus 로고
    • Cardiovascular risk prediction based on home versus office blood pressure measurement: The didima study
    • in press
    • Stergiou GS, Kalogeropoulos P, Sarantos K, Baibas N, (in press). Cardiovascular risk prediction based on home versus office blood pressure measurement: the didima study. J Hypertens
    • J Hypertens
    • Stergiou, G.S.1    Kalogeropoulos, P.2    Sarantos, K.3    Baibas, N.4
  • 15
    • 5144226187 scopus 로고    scopus 로고
    • Stergiou G, Mengden T, Padfield P, Parati G, O'Brien E, on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Self-blood pressure monitoring at home is an important adjunct to clinic measurements in patients with hypertension. BMJ 2004; 329:870-871.
    • Stergiou G, Mengden T, Padfield P, Parati G, O'Brien E, on behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Self-blood pressure monitoring at home is an important adjunct to clinic measurements in patients with hypertension. BMJ 2004; 329:870-871.
  • 16
    • 33947152507 scopus 로고    scopus 로고
    • Pickering TG. Self-monitoring of blood pressure. In: Ambulatory monitoring and blood pressure variability (Part 1). London: Science Press; 1990. pp. 8.5.
    • Pickering TG. Self-monitoring of blood pressure. In: Ambulatory monitoring and blood pressure variability (Part 1). London: Science Press; 1990. pp. 8.5.
  • 17
    • 0033664125 scopus 로고    scopus 로고
    • Diagnosis of hypertension using home or ambulatory blood pressure monitoring: Comparison with the conventional strategy based on repeated clinic blood pressure measurements
    • Stergiou GS, Skeva II, Baibas N, Kalkana C, Roussias LG, Mountokalakis T. Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements. J Hypertens 2000; 18:1745-1751.
    • (2000) J Hypertens , vol.18 , pp. 1745-1751
    • Stergiou, G.S.1    Skeva, I.I.2    Baibas, N.3    Kalkana, C.4    Roussias, L.G.5    Mountokalakis, T.6
  • 18
    • 0037527647 scopus 로고    scopus 로고
    • European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension. J Hypertens 2003; 21:1011-1053
    • European Society of Hypertension-European Society of Cardiology guidelines for the management of arterial hypertension. J Hypertens 2003; 21:1011-1053.
  • 19
    • 0347423198 scopus 로고    scopus 로고
    • Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr, et al. Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Hypertension 2003; 42:1206-1252.
    • (2003) Hypertension , vol.42 , pp. 1206-1252
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo Jr, J.L.6
  • 20
    • 20144375119 scopus 로고    scopus 로고
    • Hemmelgarn BR, McAlister FA, Myers MG, McKay DW, Bolli P, Abbott C, et al., for the Canadian Hypertension Educational Program. The 2005 Canadian Hypertension Education Program recommendations for the management of hypertension: Part 1: blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2005; 21:645-656.
    • Hemmelgarn BR, McAlister FA, Myers MG, McKay DW, Bolli P, Abbott C, et al., for the Canadian Hypertension Educational Program. The 2005 Canadian Hypertension Education Program recommendations for the management of hypertension: Part 1: blood pressure measurement, diagnosis and assessment of risk. Can J Cardiol 2005; 21:645-656.
  • 21
    • 33947180455 scopus 로고    scopus 로고
    • dabl® Educational Trust: Devices for blood pressure measurement. http://www.dableducational.org. Assessed 16 September 2006.
    • dabl® Educational Trust: Devices for blood pressure measurement. http://www.dableducational.org. Assessed 16 September 2006.
  • 23
    • 0035200150 scopus 로고    scopus 로고
    • Reporting bias in self-measurement of blood pressure
    • Myers M. Reporting bias in self-measurement of blood pressure. Blood Press Monit 2001; 6:181-183.
    • (2001) Blood Press Monit , vol.6 , pp. 181-183
    • Myers, M.1
  • 24
    • 2642542406 scopus 로고    scopus 로고
    • Self blood pressure measurement at home: How many times?
    • Parati G, Stergiou GS. Self blood pressure measurement at home: how many times? J Hypertens 2004; 22:1075-1079.
    • (2004) J Hypertens , vol.22 , pp. 1075-1079
    • Parati, G.1    Stergiou, G.S.2
  • 25
    • 0031861524 scopus 로고    scopus 로고
    • Self monitoring of blood pressure at home: How many measurements are needed?
    • Stergiou GS, Skeva II, Zourbaki AS, Mountokalakis T. Self monitoring of blood pressure at home: how many measurements are needed? J Hypertens 1998; 16:725-731.
    • (1998) J Hypertens , vol.16 , pp. 725-731
    • Stergiou, G.S.1    Skeva, I.I.2    Zourbaki, A.S.3    Mountokalakis, T.4
  • 26
    • 0035992025 scopus 로고    scopus 로고
    • On behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, et al., On behalf of the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17.
    • (2002) Blood Press Monit , vol.7 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6
  • 27
    • 33746112932 scopus 로고    scopus 로고
    • Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol
    • Stergiou GS, Giovas P, Neofytou M, Adamopoulos D. Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol. Blood Press Monit 2006; 11:157-160.
    • (2006) Blood Press Monit , vol.11 , pp. 157-160
    • Stergiou, G.S.1    Giovas, P.2    Neofytou, M.3    Adamopoulos, D.4
  • 28
    • 33947149640 scopus 로고    scopus 로고
    • Validation of the Microlife WatchBP Home device for self-home blood pressure measurement according to the International Protocol
    • in press
    • Stergiou GS, Giovas P, Ginos C, Patouras JD. Validation of the Microlife WatchBP Home device for self-home blood pressure measurement according to the International Protocol. Blood Pres Monit 2007 (in press).
    • (2007) Blood Pres Monit
    • Stergiou, G.S.1    Giovas, P.2    Ginos, C.3    Patouras, J.D.4
  • 29
    • 33947108431 scopus 로고    scopus 로고
    • Stergiou GS, Giovas P, Bernd J, Arron C, CY Y, Tan TM. Microlife Watch BP Monitor: a tool for reliable home BP monitoring designed strictly according to the European Society of Hypertension Working Group on BP Monitoring recommendations. 21st Scientific Meeting of the International Society of Hypertension [abstract]. J Hypertens 2006; (Suppl 6):S266.
    • Stergiou GS, Giovas P, Bernd J, Arron C, CY Y, Tan TM. Microlife Watch BP Monitor: a tool for reliable home BP monitoring designed strictly according to the European Society of Hypertension Working Group on BP Monitoring recommendations. 21st Scientific Meeting of the International Society of Hypertension [abstract]. J Hypertens 2006; (Suppl 6):S266.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.