메뉴 건너뛰기




Volumn 132, Issue 2, 2012, Pages 239-244

Minimally invasive plate osteosynthesis using anterior-inferior plating of clavicular midshaft fractures

Author keywords

Anterior inferior plating; Clavicular midshaft fracture; Minimally invasive plate osteosynthesis

Indexed keywords

ADULT; AGED; ARTICLE; CLAVICLE FRACTURE; CLAVICULAR MIDSHAFT FRACTURE; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FRACTURE HEALING; FUNCTIONAL ASSESSMENT; HUMAN; INCISION; MALE; MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS; OPERATION DURATION; PLATE FIXATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RANGE OF MOTION; SCORING SYSTEM; SHOULDER RADIOGRAPHY; SURGICAL TECHNIQUE; TREATMENT FAILURE;

EID: 84857632846     PISSN: 09368051     EISSN: 14343916     Source Type: Journal    
DOI: 10.1007/s00402-011-1410-6     Document Type: Article
Times cited : (27)

References (22)
  • 2
    • 0030785720 scopus 로고    scopus 로고
    • Closed treatment of displaced middle-third fractures of the clavicle gives poor results
    • DOI 10.1302/0301-620X.79B4.7529
    • JM Hill MH McGuire LA Crosby 1997 Closed treatment of displaced middle-third fractures of the clavicle gives poor results J Bone Joint Surg Br 79 4 537 539 9250733 10.1302/0301-620X.79B4.7529 1:STN:280:DyaK2szpt1Giuw%3D%3D (Pubitemid 27346103)
    • (1997) Journal of Bone and Joint Surgery - Series B , vol.79 , Issue.4 , pp. 537-539
    • Hill, J.M.1    McGuire, M.H.2    Crosby, L.A.3
  • 3
    • 24644480089 scopus 로고    scopus 로고
    • Treatment of acute midshaft clavicle fractures: Systematic review of 2144 fractures. On behalf of the Evidence-Based Orthopaedic Trauma Working Group
    • DOI 10.1097/01.bot.0000172287.44278.ef
    • M Zlowodzki BA Zelle PA Cole K Jeray MD McKee 2005 Treatment of acute midshaft fractures: systemic review of 2,144 fractures J Orthop Trauma 19 7 504 507 16056089 10.1097/01.bot.0000172287.44278.ef (Pubitemid 41264730)
    • (2005) Journal of Orthopaedic Trauma , vol.19 , Issue.7 , pp. 504-507
    • Zlowodzki, M.1    Zelle, B.A.2    Cole, P.A.3    Jeray, K.4    McKee, M.D.5
  • 5
    • 0036122802 scopus 로고    scopus 로고
    • Clavicular fracture non-union surgical outcome and complications
    • DOI 10.1016/S0020-1383(01)00069-9, PII S0020138301000699
    • J Der Tavitian JN Davison JJ Dias 2002 Clavicular fracture non-union surgical outcome and complications Injury 33 2 135 143 11890915 10.1016/S0020-1383(01)00069-9 1:STN:280:DC%2BD387lvFOqtg%3D%3D (Pubitemid 34219088)
    • (2002) Injury , vol.33 , Issue.2 , pp. 135-143
    • Der Tavitian, J.1    Davison, J.N.S.2    Dias, J.J.3
  • 7
    • 39649098673 scopus 로고    scopus 로고
    • Infection after surgical reconstruction of a clavicle fracture using a reconstruction plate: A report of seven cases
    • 18218570 10.1016/S1607-551X(08)70073-1 1:CAS:528:DC%2BD1cXit1Smt70%3D
    • PC Liu CH Hsieh JC Chen CC Lu CY Chuo SH Chien 2008 Infection after surgical reconstruction of a clavicle fracture using a reconstruction plate: a report of seven cases Kaohsiung J Med Sci 24 1 45 49 18218570 10.1016/S1607-551X(08)70073-1 1:CAS:528:DC%2BD1cXit1Smt70%3D
    • (2008) Kaohsiung J Med Sci , vol.24 , Issue.1 , pp. 45-49
    • Liu, P.C.1    Hsieh, C.H.2    Chen, J.C.3    Lu, C.C.4    Chuo, C.Y.5    Chien, S.H.6
  • 8
    • 64749109572 scopus 로고    scopus 로고
    • Intramedullary nailing of clavicular midshaft fractures with the titanium elastic nail
    • 10.1177/0363546508328103
    • A Frigg P Rillmann T Perren M Gerber C Ryf 2010 Intramedullary nailing of clavicular midshaft fractures with the titanium elastic nail Am J Sports Med 37 2 352 359 10.1177/0363546508328103
    • (2010) Am J Sports Med , vol.37 , Issue.2 , pp. 352-359
    • Frigg, A.1    Rillmann, P.2    Perren, T.3    Gerber, M.4    Ryf, C.5
  • 9
    • 61549122382 scopus 로고    scopus 로고
    • Elastic stable intramedullary nailing versus nonoperative treatment of displaced midshaft clavicular fractures-a randomized, controlled, clinical trial
    • 19169102 10.1097/BOT.0b013e318190cf88
    • V Smekal A Irenberger P Struve M Wambacher D Krappinger FS Kralinger 2009 Elastic stable intramedullary nailing versus nonoperative treatment of displaced midshaft clavicular fractures-a randomized, controlled, clinical trial J Orthop Trauma 23 2 106 112 19169102 10.1097/BOT.0b013e318190cf88
    • (2009) J Orthop Trauma , vol.23 , Issue.2 , pp. 106-112
    • Smekal, V.1    Irenberger, A.2    Struve, P.3    Wambacher, M.4    Krappinger, D.5    Kralinger, F.S.6
  • 10
    • 55749111983 scopus 로고    scopus 로고
    • Length determination in midshaft clavicle fractures: Validation of measurement
    • 18670285 10.1097/BOT.0b013e318178d97d
    • V Smekal C Deml A Irenberger C Niederwanger M Lutz M Blauth D Krappinger 2008 Length determination in midshaft clavicle fractures: validation of measurement J Orthop Trauma 22 7 458 462 18670285 10.1097/BOT.0b013e318178d97d
    • (2008) J Orthop Trauma , vol.22 , Issue.7 , pp. 458-462
    • Smekal, V.1    Deml, C.2    Irenberger, A.3    Niederwanger, C.4    Lutz, M.5    Blauth, M.6    Krappinger, D.7
  • 11
    • 14744300697 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture: Is it possible? A cadaveric study and preliminary report
    • DOI 10.1016/j.injury.2004.05.036
    • T Apivatthakakul O Arpornchayanon S Bavornratanavech 2005 Minimally invasive plate osteosynthesis of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report Injury 36 4 530 538 15755436 10.1016/j.injury.2004.05.036 1:STN:280:DC%2BD2M7isV2ltA%3D%3D (Pubitemid 40332338)
    • (2005) Injury , vol.36 , Issue.4 , pp. 530-538
    • Apivatthakakul, T.1    Arpornchayanon, O.2    Bavornratanavech, S.3
  • 12
    • 0031452816 scopus 로고    scopus 로고
    • Minimally invasive plate osteosynthesis of distal fractures of the tibia
    • PII S0020138397000776
    • DL Helfet PY Shonnard D Levine J Borrelli Jr 1997 Minimally invasive plate osteosynthesis of distal fracture of the tibia Injury 28 Suppl 1 42 48 10.1016/S0020-1383(97)90114-5 (Pubitemid 28005965)
    • (1997) Injury , vol.28 , Issue.SUPPL.1 , pp. 42-48
    • Helfet, D.L.1    Shonnard, P.Y.2    Levine, D.3    Borrelli Jr., J.4
  • 13
    • 0031468135 scopus 로고    scopus 로고
    • Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fracture
    • PII S0020138397000752
    • C Krettek P Schandelmaier T Miclau H Tscherne 1997 Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures Injury 28 Suppl 1 20 30 10.1016/S0020-1383(97)90112-1 (Pubitemid 28005963)
    • (1997) Injury , vol.28 , Issue.SUPPL.1 , pp. 20-30
    • Krettek, C.1    Schandelmaier, P.2    Miclau, T.3    Tscherne, H.4
  • 14
    • 0041346511 scopus 로고    scopus 로고
    • Effects of plate location and selection on the stability of midshaft clavicle osteotomies: A biomechanical study
    • DOI 10.1067/mse.2002.125805
    • MR Iannotti LA Crosby P Stafford G Grayson R Goulet 2002 Effect of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study J Shoulder Elbow Surg 11 5 452 467 10.1067/mse.2002.125805 (Pubitemid 36904207)
    • (2002) Journal of Shoulder and Elbow Surgery , vol.11 , Issue.5 , pp. 457-462
    • Iannotti, M.R.1    Crosby, L.A.2    Stafford, P.3    Grayson, G.4    Goulet, R.5
  • 15
    • 42049088290 scopus 로고    scopus 로고
    • Biomechanical evaluation of clavicle fracture plating techniques: Does a locking plate provide improved stability?
    • DOI 10.1097/BOT.0b013e31816c7bac, PII 0000513120080400000007
    • P Celestre C Roberston A Mahar R Oka M Meunier A Schwartz 2008 Biomechanical evaluation of clavicle fracture plating technique: does a locking plate provide improved stability? J Orthop Trauma 22 4 241 247 18404033 10.1097/BOT.0b013e31816c7bac (Pubitemid 351521601)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.4 , pp. 241-247
    • Celestre, P.1    Roberston, C.2    Mahar, A.3    Oka, R.4    Meunier, M.5    Schwartz, A.6
  • 16
    • 0030200943 scopus 로고    scopus 로고
    • Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
    • DOI 10.1016/0268-0033(96)00001-0
    • T Harnroongroj V Vanadurongwan 1996 Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect Clin Biomech 11 5 290 294 10.1016/0268-0033(96)00001-0 (Pubitemid 26235698)
    • (1996) Clinical Biomechanics , vol.11 , Issue.5 , pp. 290-294
    • Harnroongroj, T.1    Vanadurongwan, V.2
  • 17
    • 0013446335 scopus 로고    scopus 로고
    • Fractures of the clavicle
    • C.A. Rockwood (eds). 4 WB Saunders Philadelphia
    • Basamania CJ, Rockwood CA (2008) Fractures of the clavicle. In: Rockwood CA (ed) The shoulder, 4th edn. WB Saunders, Philadelphia, pp 423-428
    • (2008) The Shoulder , pp. 423-428
    • Basamania, C.J.1    Rockwood, C.A.2
  • 18
    • 57449087054 scopus 로고    scopus 로고
    • Failure of superior locking clavicle plate by axial pull-out of the lateral screws: A report of four cases
    • 18774739 10.1016/j.jse.2008.05.042
    • KM Brouwer TC Wright DC Ring 2009 Failure of superior locking clavicle plate by axial pull-out of the lateral screws: a report of four cases J Shoulder Elbow Surg 18 e22 e25 18774739 10.1016/j.jse.2008.05.042
    • (2009) J Shoulder Elbow Surg , vol.18
    • Brouwer, K.M.1    Wright, T.C.2    Ring, D.C.3
  • 19
    • 77951024251 scopus 로고    scopus 로고
    • Anterior-inferior plating of middle-third fractures of the clavicle
    • 10.1007/s00402-009-0993-7
    • CE Chen RJ Juhn JY Ko 2010 Anterior-inferior plating of middle-third fractures of the clavicle Arch Orthop Traum Surg 130 4 507 511 10.1007/s00402-009-0993-7
    • (2010) Arch Orthop Traum Surg , vol.130 , Issue.4 , pp. 507-511
    • Chen, C.E.1    Juhn, R.J.2    Ko, J.Y.3
  • 20
    • 33751055846 scopus 로고    scopus 로고
    • Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle
    • DOI 10.1097/01.bot.0000249434.57571.29, PII 0000513120061100000005
    • C Collinge S Devinney D Herscovici T DiPasquale R Sanders 2006 Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle J Orthop Trauma 20 10 680 686 17106378 10.1097/01.bot.0000249434.57571. 29 (Pubitemid 44760282)
    • (2006) Journal of Orthopaedic Trauma , vol.20 , Issue.10 , pp. 746-747
    • Collinge, C.1    Devinney, S.2    Herscovici, D.3    DiPasquale, T.4    Sanders, R.5
  • 21
    • 0036065856 scopus 로고    scopus 로고
    • Anteroinferior plating of midshaft clavicular nonunions
    • DOI 10.1097/00005131-200207000-00011
    • P Kloen AT Sorkin IF Rubel DL Helfet 2002 Anteroinferior plating of midshaft clavicular nonunions J Orthop Trauma 16 6 425 430 12142833 10.1097/00005131-200207000-00011 1:STN:280:DC%2BD38zpt1ersw%3D%3D (Pubitemid 34785162)
    • (2002) Journal of Orthopaedic Trauma , vol.16 , Issue.6 , pp. 425-430
    • Kloen, P.1    Sorkin, A.T.2    Rubel, I.F.3    Helfet, D.L.4
  • 22
    • 77949911269 scopus 로고    scopus 로고
    • Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating
    • 10.1007/s00402-009-0864-2
    • SA Stufkens P Kloen 2010 Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating Arch Orthop Traum Surg 130 2 159 164 10.1007/s00402-009-0864-2
    • (2010) Arch Orthop Traum Surg , vol.130 , Issue.2 , pp. 159-164
    • Stufkens, S.A.1    Kloen, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.