메뉴 건너뛰기




Volumn 130, Issue 4, 2010, Pages 507-511

Anterior-inferior plating of middle-third fractures of the clavicle

Author keywords

Anterior inferior plating Superior plating; Clavicle; Clavicle fracture; Collar bone

Indexed keywords

ADULT; AGED; ARTICLE; BONE PLATE; CLAVICLE FRACTURE; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; COMMINUTED FRACTURE; CONTROLLED STUDY; DEVICE REMOVAL; FEMALE; FOLLOW UP; FRACTURE FIXATION; FRACTURE HEALING; HUMAN; INJURY SEVERITY; JOINT FUNCTION; MALE; PHYSICAL ACTIVITY; PHYSIOTHERAPY; PLATE FIXATION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RADIODIAGNOSIS; SHOULDER; TREATMENT INDICATION; TREATMENT RESPONSE;

EID: 77951024251     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-009-0993-7     Document Type: Article
Times cited : (26)

References (15)
  • 1
    • 40349084428 scopus 로고    scopus 로고
    • Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures
    • Canadian Orthopaedic Trauma Society
    • Altamimi SA, McKee MD, Canadian Orthopaedic Trauma Society (2008) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. J Bone Joint Surg Am 90(Suppl 2):1-8
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL 2 , pp. 1-8
    • Altamimi, S.A.1    McKee, M.D.2
  • 2
    • 0000236733 scopus 로고    scopus 로고
    • Complications of plate fixation in fresh displaced midclavicular fractures
    • Bostman O, Manninen M, Pihlajamaki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma43:778-783
    • (1997) J Trauma , vol.43 , pp. 778-783
    • Bostman, O.1    Manninen, M.2    Pihlajamaki, H.3
  • 3
    • 42049088290 scopus 로고    scopus 로고
    • Biomechanical evaluation of clavicle fracture plating techniques does a locking plate provide improved stability?
    • Celestre P, Roberston C, Mahar A et al (2008) Biomechanical evaluation of clavicle fracture plating techniques: does a locking plate provide improved stability? J Orthop Trauma 22:241-247
    • (2008) J Orthop Trauma , vol.22 , pp. 241-247
    • Celestre, P.1    Roberston, C.2    Mahar, A.3
  • 4
    • 33751055846 scopus 로고    scopus 로고
    • Anteriorinferior plate fixation of middle-third fractures and nonunions of the clavicle
    • Collinge C, Devinney S, Herscovici D et al (2006) Anteriorinferior plate fixation of middle-third fractures and nonunions of the clavicle. J Orthop Trauma 20:680-686
    • (2006) J Orthop Trauma , vol.20 , pp. 680-686
    • Collinge, C.1    Devinney, S.2    Herscovici, D.3
  • 5
    • 0030200943 scopus 로고    scopus 로고
    • Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect
    • Harnroongroj T, Vanadurongwan V (1996) Biomechanical aspects of plating osteosynthesis of transverse clavicular fracture with and without inferior cortical defect. Clin Biomech 11:290-294
    • (1996) Clin Biomech , vol.11 , pp. 290-294
    • Harnroongroj, T.1    Vanadurongwan, V.2
  • 6
    • 0030785720 scopus 로고    scopus 로고
    • Closed treatment of displaced middle-third fractures of the clavicle gives poor results
    • Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79:537-539
    • (1997) J Bone Joint Surg Br , vol.79 , pp. 537-539
    • Hill, J.M.1    McGuire, M.H.2    Crosby, L.A.3
  • 7
    • 0041346511 scopus 로고    scopus 로고
    • Effect of plate location and selection on the stability of midshaft clavicle osteotomies: A biomechanical study
    • Iannotti MR, Crosby LA, Stafford P et al (2002) Effect of plate location and selection on the stability of midshaft clavicle osteotomies: a biomechanical study. J Shoulder Elbow Surg 11:457-462
    • (2002) J Shoulder Elbow Surg. , vol.11 , pp. 457-462
    • Iannotti, M.R.1    Crosby, L.A.2    Stafford, P.3
  • 9
    • 0036065856 scopus 로고    scopus 로고
    • Anteroinferior plating of midshaft clavicular nonunions
    • Kloen P, Sorkin AT, Rubel IF et al (2002) Anteroinferior plating of midshaft clavicular nonunions. J Orthop Trauma 16:425-430
    • (2002) J Orthop Trauma , vol.16 , pp. 425-430
    • Kloen, P.1    Sorkin, A.T.2    Rubel, I.F.3
  • 10
    • 39149129995 scopus 로고    scopus 로고
    • Fracture and dislocation classification compendium-2007
    • Marsh JL, Slongo TF, Agel J et al (2007) Fracture and dislocation classification compendium-2007. J Orthop Trauma 21:S1-133
    • (2007) J Orthop Trauma , vol.21
    • Marsh, J.L.1    Slongo, T.F.2    Agel, J.3
  • 11
    • 34347391232 scopus 로고    scopus 로고
    • Elastic stable intramedullary nailing of midclaviclar fractures in adults: 32 patients followed for 1-5 years
    • Mueller M, Burger C, Florczyk A et al (2007) Elastic stable intramedullary nailing of midclaviclar fractures in adults: 32 patients followed for 1-5 years. Acta Orthop 78:421-423
    • (2007) Acta Orthop , vol.78 , pp. 421-423
    • Mueller, M.1    Burger, C.2    Florczyk, A.3
  • 12
  • 13
    • 24144436901 scopus 로고    scopus 로고
    • Sequelae from clavicular fractures are common
    • Nowak J, Holgersson M, Larsson S (2005) Sequelae from clavicular fractures are common. Acta Orthop 76:496-502
    • (2005) Acta Orthop , vol.76 , pp. 496-502
    • Nowak, J.1    Holgersson, M.2    Larsson, S.3
  • 14
    • 0032854198 scopus 로고    scopus 로고
    • Plate fixation of fresh displaced midshaft clavicle fractures
    • Shen WJ, Liu TJ, Shen YS (1999) Plate fixation of fresh displaced midshaft clavicle fractures. Injury 30:497-500
    • (1999) Injury , vol.30 , pp. 497-500
    • Shen, W.J.1    Liu, T.J.2    Shen, Y.S.3
  • 15
    • 24644480089 scopus 로고    scopus 로고
    • Treatment of acute midshaft clavicle fractures: Systemic review of 2144 fractures
    • Zlowodzki M, Zelle BA, Cole PA et al (2005) Treatment of acute midshaft clavicle fractures: systemic review of 2144 fractures. J Orthop Trauma 19:504-507
    • (2005) J Orthop Trauma , vol.19 , pp. 504-507
    • Zlowodzki, M.1    Zelle, B.A.2    Cole, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.