메뉴 건너뛰기




Volumn 10, Issue 3, 2012, Pages 437-446

Impact of pre-analytical parameters on the measurement of circulating microparticles: Towards standardization of protocol

Author keywords

Microparticles; Pre analytics; Standardization

Indexed keywords

PROCOAGULANT; THROMBIN;

EID: 84857560160     PISSN: 15387933     EISSN: 15387836     Source Type: Journal    
DOI: 10.1111/j.1538-7836.2011.04610.x     Document Type: Article
Times cited : (328)

References (46)
  • 1
    • 20444417577 scopus 로고    scopus 로고
    • More on: measuring circulating cell-derived microparticles
    • Freyssinet JM, Dignat-George F. More on: measuring circulating cell-derived microparticles. J Thromb Haemost 2005; 3: 613-14.
    • (2005) J Thromb Haemost , vol.3 , pp. 613-614
    • Freyssinet, J.M.1    Dignat-George, F.2
  • 2
    • 67650531887 scopus 로고    scopus 로고
    • Microvesicles: messengers and mediators of tumor progression
    • Al-Nedawi K, Meehan B, Rak J. Microvesicles: messengers and mediators of tumor progression. Cell Cycle. 2009; 8: 2014-18.
    • (2009) Cell Cycle. , vol.8 , pp. 2014-2018
    • Al-Nedawi, K.1    Meehan, B.2    Rak, J.3
  • 3
    • 69549116335 scopus 로고    scopus 로고
    • Microparticles and thrombotic disease
    • Davizon P, Lopez JA. Microparticles and thrombotic disease. Curr Opin Hematol 2009; 16: 334-41.
    • (2009) Curr Opin Hematol , vol.16 , pp. 334-341
    • Davizon, P.1    Lopez, J.A.2
  • 4
    • 34447297875 scopus 로고    scopus 로고
    • The role of microparticles in inflammation and thrombosis
    • Ardoin SP, Shanahan JC, Pisetsky DS. The role of microparticles in inflammation and thrombosis. Scand J Immunol 2007; 66: 159-65.
    • (2007) Scand J Immunol , vol.66 , pp. 159-165
    • Ardoin, S.P.1    Shanahan, J.C.2    Pisetsky, D.S.3
  • 5
    • 33748147424 scopus 로고    scopus 로고
    • Circulating microparticles: a potential prognostic marker for atherosclerotic vascular disease
    • Boulanger CM, Amabile N, Tedgui A. Circulating microparticles: a potential prognostic marker for atherosclerotic vascular disease. Hypertension. 2006; 48: 180-6.
    • (2006) Hypertension. , vol.48 , pp. 180-186
    • Boulanger, C.M.1    Amabile, N.2    Tedgui, A.3
  • 6
    • 3042716498 scopus 로고    scopus 로고
    • Cellular microparticles: new players in the field of vascular disease?
    • Diamant M, Tushuizen ME, Sturk A, Nieuwland R. Cellular microparticles: new players in the field of vascular disease? Eur J Clin Invest 2004; 34: 392-401.
    • (2004) Eur J Clin Invest , vol.34 , pp. 392-401
    • Diamant, M.1    Tushuizen, M.E.2    Sturk, A.3    Nieuwland, R.4
  • 7
    • 72549102588 scopus 로고    scopus 로고
    • Tumor-derived tissue factor-bearing microparticles are associated with venous thromboembolic events in malignancy
    • Zwicker JI, Liebman HA, Neuberg D, Lacroix R, Bauer KA, Furie BC, Furie B. Tumor-derived tissue factor-bearing microparticles are associated with venous thromboembolic events in malignancy. Clin Cancer Res 2009; 15: 6830-40.
    • (2009) Clin Cancer Res , vol.15 , pp. 6830-6840
    • Zwicker, J.I.1    Liebman, H.A.2    Neuberg, D.3    Lacroix, R.4    Bauer, K.A.5    Furie, B.C.6    Furie, B.7
  • 9
    • 63049097550 scopus 로고    scopus 로고
    • Circulating endothelial cells, microparticles and progenitors: key players towards the definition of vascular competence
    • Sabatier F, Camoin-Jau L, Anfosso F, Sampol J, Dignat-George F. Circulating endothelial cells, microparticles and progenitors: key players towards the definition of vascular competence. J Cell Mol Med 2009; 13: 454-71.
    • (2009) J Cell Mol Med , vol.13 , pp. 454-471
    • Sabatier, F.1    Camoin-Jau, L.2    Anfosso, F.3    Sampol, J.4    Dignat-George, F.5
  • 10
    • 52249096984 scopus 로고    scopus 로고
    • Characterizing blood microparticles: technical aspects and challenges
    • Shet AS. Characterizing blood microparticles: technical aspects and challenges. Vasc Health Risk Manag. 2008; 4: 769-74.
    • (2008) Vasc Health Risk Manag. , vol.4 , pp. 769-774
    • Shet, A.S.1
  • 11
    • 38549176742 scopus 로고    scopus 로고
    • Detection and measurement of microparticles: an evolving research tool for vascular biology
    • Enjeti AK, Lincz LF, Seldon M. Detection and measurement of microparticles: an evolving research tool for vascular biology. Semin Thromb Hemost 2007; 33: 771-9.
    • (2007) Semin Thromb Hemost , vol.33 , pp. 771-779
    • Enjeti, A.K.1    Lincz, L.F.2    Seldon, M.3
  • 12
    • 34047111681 scopus 로고    scopus 로고
    • Circulating microparticles: pathophysiology and clinical implications
    • Piccin A, Murphy WG, Smith OP. Circulating microparticles: pathophysiology and clinical implications. Blood Rev 2007; 21: 157-71.
    • (2007) Blood Rev , vol.21 , pp. 157-171
    • Piccin, A.1    Murphy, W.G.2    Smith, O.P.3
  • 13
    • 77955415593 scopus 로고    scopus 로고
    • Pre-analytical and methodological challenges in red blood cell microparticle proteomics
    • Rubin O, Crettaz D, Tissot JD, Lion N. Pre-analytical and methodological challenges in red blood cell microparticle proteomics. Talanta 2010; 82: 1-8.
    • (2010) Talanta , vol.82 , pp. 1-8
    • Rubin, O.1    Crettaz, D.2    Tissot, J.D.3    Lion, N.4
  • 16
    • 0034938879 scopus 로고    scopus 로고
    • Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories
    • Polack B, Schved JF, Boneu B. Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis. 2001; 31: 61-8.
    • (2001) Haemostasis. , vol.31 , pp. 61-68
    • Polack, B.1    Schved, J.F.2    Boneu, B.3
  • 20
    • 17044405129 scopus 로고    scopus 로고
    • Preanalytical variability in laboratory testing: influence of the blood drawing technique
    • Lippi G, Salvagno GL, Brocco G, Guidi GC. Preanalytical variability in laboratory testing: influence of the blood drawing technique. Clin Chem Lab Med 2005; 43: 319-25.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 319-325
    • Lippi, G.1    Salvagno, G.L.2    Brocco, G.3    Guidi, G.C.4
  • 22
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: the dark side of the moon in laboratory testing
    • Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 2006; 44: 358-65.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 24
    • 78149287957 scopus 로고    scopus 로고
    • Mechanisms of microparticle generation: on the trail of the mitochondrion!
    • Morel O, Toti F, Jesel L, Freyssinet JM. Mechanisms of microparticle generation: on the trail of the mitochondrion!. Semin Thromb Hemost 2010; 36: 833-44.
    • (2010) Semin Thromb Hemost , vol.36 , pp. 833-844
    • Morel, O.1    Toti, F.2    Jesel, L.3    Freyssinet, J.M.4
  • 25
    • 1542350341 scopus 로고    scopus 로고
    • Comparison of five different citrated tubes and their in vitro effects on platelet activation
    • Philippe J, De Logi E, Baele G. Comparison of five different citrated tubes and their in vitro effects on platelet activation. Clin Chem 2004; 50: 656-8.
    • (2004) Clin Chem , vol.50 , pp. 656-658
    • Philippe, J.1    De Logi, E.2    Baele, G.3
  • 26
    • 77449150554 scopus 로고    scopus 로고
    • Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample
    • Lippi G, Salvagno GL, Adcock DM, Gelati M, Guidi GC, Favaloro EJ. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample. Int J Lab Hematol. 2010; 32: 132-8.
    • (2010) Int J Lab Hematol. , vol.32 , pp. 132-138
    • Lippi, G.1    Salvagno, G.L.2    Adcock, D.M.3    Gelati, M.4    Guidi, G.C.5    Favaloro, E.J.6
  • 27
    • 0033152960 scopus 로고    scopus 로고
    • Preanalytical requirements for flow cytometric evaluation of platelet activation: choice of anticoagulant
    • Mody M, Lazarus AH, Semple JW, Freedman J. Preanalytical requirements for flow cytometric evaluation of platelet activation: choice of anticoagulant. Transfus Med 1999; 9: 147-54.
    • (1999) Transfus Med , vol.9 , pp. 147-154
    • Mody, M.1    Lazarus, A.H.2    Semple, J.W.3    Freedman, J.4
  • 28
    • 0036630778 scopus 로고    scopus 로고
    • Optimized flow cytometric assay for the measurement of platelet microparticles in plasma: pre-analytic and analytic considerations
    • Kim HK, Song KS, Lee ES, Lee YJ, Park YS, Lee KR, Lee SN. Optimized flow cytometric assay for the measurement of platelet microparticles in plasma: pre-analytic and analytic considerations. Blood Coagul Fibrinolysis 2002; 13: 393-7.
    • (2002) Blood Coagul Fibrinolysis , vol.13 , pp. 393-397
    • Kim, H.K.1    Song, K.S.2    Lee, E.S.3    Lee, Y.J.4    Park, Y.S.5    Lee, K.R.6    Lee, S.N.7
  • 29
    • 67651087058 scopus 로고    scopus 로고
    • A rapid flow cytometric technique for the detection of platelet-monocyte complexes, activated platelets and platelet-derived microparticles
    • Pearson L, Thom J, Adams M, Oostryck R, Krueger R, Yong G, Baker R. A rapid flow cytometric technique for the detection of platelet-monocyte complexes, activated platelets and platelet-derived microparticles. Int J Lab Hematol. 2009; 31: 430-9.
    • (2009) Int J Lab Hematol. , vol.31 , pp. 430-439
    • Pearson, L.1    Thom, J.2    Adams, M.3    Oostryck, R.4    Krueger, R.5    Yong, G.6    Baker, R.7
  • 30
    • 33745622650 scopus 로고    scopus 로고
    • Effects of storage-induced platelet microparticles on the initiation and propagation phase of blood coagulation
    • Keuren JF, Magdeleyns EJ, Govers-Riemslag JW, Lindhout T, Curvers J. Effects of storage-induced platelet microparticles on the initiation and propagation phase of blood coagulation. Br J Haematol 2006; 134: 307-13.
    • (2006) Br J Haematol , vol.134 , pp. 307-313
    • Keuren, J.F.1    Magdeleyns, E.J.2    Govers-Riemslag, J.W.3    Lindhout, T.4    Curvers, J.5
  • 31
    • 53849106127 scopus 로고    scopus 로고
    • Microparticles in stored red blood cells: an approach using flow cytometry and proteomic tools
    • Rubin O, Crettaz D, Canellini G, Tissot JD, Lion N. Microparticles in stored red blood cells: an approach using flow cytometry and proteomic tools. Vox Sang 2008; 95: 288-97.
    • (2008) Vox Sang , vol.95 , pp. 288-297
    • Rubin, O.1    Crettaz, D.2    Canellini, G.3    Tissot, J.D.4    Lion, N.5
  • 32
    • 79952513429 scopus 로고    scopus 로고
    • Pre-analytical and analytical issues in the analysis of blood microparticles
    • Yuana Y, Bertina RM, Osanto S. Pre-analytical and analytical issues in the analysis of blood microparticles. Thromb Haemost 2011; 105: 396-408.
    • (2011) Thromb Haemost , vol.105 , pp. 396-408
    • Yuana, Y.1    Bertina, R.M.2    Osanto, S.3
  • 33
    • 13344249119 scopus 로고    scopus 로고
    • Numeration of circulating microparticles of various cellular origin by flow cytometry
    • Dignat-George F, Sabatier F, Camoin L, Sampol J. Numeration of circulating microparticles of various cellular origin by flow cytometry. J Thromb Haemost 2004; 2: 1844-5.
    • (2004) J Thromb Haemost , vol.2 , pp. 1844-1845
    • Dignat-George, F.1    Sabatier, F.2    Camoin, L.3    Sampol, J.4
  • 34
    • 57749190349 scopus 로고    scopus 로고
    • Standardization of platelet-derived microparticle counting using calibrated beads and a Cytomics FC500 routine flow cytometer: a first step towards multicenter studies?
    • Robert S, Poncelet P, Lacroix R, Arnaud L, Giraudo L, Hauchard A, Sampol J, Dignat-George F. Standardization of platelet-derived microparticle counting using calibrated beads and a Cytomics FC500 routine flow cytometer: a first step towards multicenter studies? J Thromb Haemost 2009; 7: 190-7.
    • (2009) J Thromb Haemost , vol.7 , pp. 190-197
    • Robert, S.1    Poncelet, P.2    Lacroix, R.3    Arnaud, L.4    Giraudo, L.5    Hauchard, A.6    Sampol, J.7    Dignat-George, F.8
  • 35
    • 19944434048 scopus 로고    scopus 로고
    • Measuring circulating cell-derived microparticles
    • Biro E, Nieuwland R, Sturk A. Measuring circulating cell-derived microparticles. J Thromb Haemost 2004; 2: 1843-4.
    • (2004) J Thromb Haemost , vol.2 , pp. 1843-1844
    • Biro, E.1    Nieuwland, R.2    Sturk, A.3
  • 36
    • 19944434048 scopus 로고    scopus 로고
    • Measuring circulating cell-derived microparticles
    • Hugel B, Zobairi F, Freyssinet JM. Measuring circulating cell-derived microparticles. J Thromb Haemost 2004; 2: 1842-51.
    • (2004) J Thromb Haemost , vol.2 , pp. 1842-1851
    • Hugel, B.1    Zobairi, F.2    Freyssinet, J.M.3
  • 41
  • 42
    • 3042693914 scopus 로고    scopus 로고
    • Elevated circulating endothelial membrane microparticles in paroxysmal nocturnal haemoglobinuria
    • Simak J, Holada K, Risitano AM, Zivny JH, Young NS, Vostal JG. Elevated circulating endothelial membrane microparticles in paroxysmal nocturnal haemoglobinuria. Br J Haematol 2004; 125: 804-13.
    • (2004) Br J Haematol , vol.125 , pp. 804-813
    • Simak, J.1    Holada, K.2    Risitano, A.M.3    Zivny, J.H.4    Young, N.S.5    Vostal, J.G.6
  • 43
    • 19944434048 scopus 로고    scopus 로고
    • Measuring circulating cell-derived microparticles
    • Biro E, Nieuwland R, Sturk A. Measuring circulating cell-derived microparticles. J Thromb Haemost 2004; 2: 1842-51.
    • (2004) J Thromb Haemost , vol.2 , pp. 1842-1851
    • Biro, E.1    Nieuwland, R.2    Sturk, A.3
  • 45
    • 29144507363 scopus 로고    scopus 로고
    • Cell membrane microparticles in blood and blood products: potentially pathogenic agents and diagnostic markers
    • Simak J, Gelderman MP. Cell membrane microparticles in blood and blood products: potentially pathogenic agents and diagnostic markers. Transfus Med Rev 2006; 20: 1-26.
    • (2006) Transfus Med Rev , vol.20 , pp. 1-26
    • Simak, J.1    Gelderman, M.P.2
  • 46
    • 58849112565 scopus 로고    scopus 로고
    • Recovery and composition of microparticles after snap-freezing depends on thawing temperature
    • Trummer A, De Rop C, Tiede A, Ganser A, Eisert R. Recovery and composition of microparticles after snap-freezing depends on thawing temperature. Blood Coagul Fibrinolysis 2009; 20: 52-6.
    • (2009) Blood Coagul Fibrinolysis , vol.20 , pp. 52-56
    • Trummer, A.1    De Rop, C.2    Tiede, A.3    Ganser, A.4    Eisert, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.