메뉴 건너뛰기




Volumn 79, Issue 4, 2012, Pages 644-653

Scanning electron microscopic assessment of coating irregularities and their precursors in unexpanded durable polymer-based drug-eluting stents

Author keywords

coating irregularity; coronary artery disease; drug eluting stent DES; durable polymer; percutaneous coronary intervention; scanning electron microscopy

Indexed keywords

ARTICLE; CONTROLLED STUDY; DRUG ELUTING STENT; MATERIAL COATING; MICROANALYSIS; PHYSICAL CHEMISTRY; QUANTITATIVE ANALYSIS; SCANNING ELECTRON MICROSCOPY; STRUCTURE ANALYSIS;

EID: 84857446333     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.23273     Document Type: Article
Times cited : (26)

References (14)
  • 1
    • 0037422604 scopus 로고    scopus 로고
    • Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions
    • DOI 10.1161/01.CIR.0000047700.58683.A1
    • Grube E, Silber S, Hauptmann KE, et al. TAXUS I: Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation 2003; 107: 38-42. (Pubitemid 36070930)
    • (2003) Circulation , vol.107 , Issue.1 , pp. 38-42
    • Grube, E.1    Silber, S.2    Hauptmann, K.E.3    Mueller, R.4    Buellesfeld, L.5    Gerckens, U.6    Russell, M.E.7
  • 3
    • 33751247472 scopus 로고    scopus 로고
    • Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: A meta-analysis
    • DOI 10.1093/eurheartj/ehl282
    • Nordmann AJ, Briel M, Bucher HC,. Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: A meta-analysis. Eur Heart J 2006; 27: 2784-2814. (Pubitemid 44871464)
    • (2006) European Heart Journal , vol.27 , Issue.23 , pp. 2784-2814
    • Nordmann, A.J.1    Briel, M.2    Bucher, H.C.3
  • 4
    • 67650755016 scopus 로고    scopus 로고
    • Safety and efficacy of drug-eluting and bare metal stents: Comprehensive meta-analysis of randomized trials and observational studies
    • Kirtane AJ, Gupta A, Iyengar S, et al. Safety and efficacy of drug-eluting and bare metal stents: Comprehensive meta-analysis of randomized trials and observational studies. Circulation 2009; 119: 3198-3206.
    • (2009) Circulation , vol.119 , pp. 3198-3206
    • Kirtane, A.J.1    Gupta, A.2    Iyengar, S.3
  • 7
  • 8
    • 33847284603 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus, and Cypher stents
    • Otsuka Y, Chronos NA, Apkarian RP, Robinson KA,. Scanning electron microscopic analysis of defects in polymer coatings of three commercially available stents: Comparison of BiodivYsio, Taxus, and Cypher stents. J Invasive Cardiol 2007; 19: 71-76.
    • (2007) J Invasive Cardiol , vol.19 , pp. 71-76
    • Otsuka, Y.1    Chronos, N.A.2    Apkarian, R.P.3    Robinson, K.A.4
  • 9
    • 80051759292 scopus 로고    scopus 로고
    • Restenosis: Delineating the numerous causes of drug-eluting stent restenosis
    • Farooq V, Gogas BD, Serruys PW,. Restenosis: Delineating the numerous causes of drug-eluting stent restenosis. Circ Cardiovasc Interv 2011; 4: 195-205.
    • (2011) Circ Cardiovasc Interv , vol.4 , pp. 195-205
    • Farooq, V.1    Gogas, B.D.2    Serruys, P.W.3
  • 10
    • 77950493770 scopus 로고    scopus 로고
    • Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents
    • Basalus MW, van Houwelingen KG, Ankone M, de Man FH, von Birgelen C,. Scanning electron microscopic assessment of the biodegradable coating on expanded biolimus-eluting stents. EuroIntervention 2009; 5: 505-510.
    • (2009) EuroIntervention , vol.5 , pp. 505-510
    • Basalus, M.W.1    Van Houwelingen, K.G.2    Ankone, M.3    De Man, F.H.4    Von Birgelen, C.5
  • 11
    • 77953675066 scopus 로고    scopus 로고
    • Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy
    • Basalus MW, Ankone MJ, van Houwelingen GK, de Man FH, von Birgelen C,. Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy. EuroIntervention 2009; 5: 157-165.
    • (2009) EuroIntervention , vol.5 , pp. 157-165
    • Basalus, M.W.1    Ankone, M.J.2    Van Houwelingen, G.K.3    De Man, F.H.4    Von Birgelen, C.5
  • 13
    • 77954100840 scopus 로고    scopus 로고
    • Benchside testing of drug-eluting stent surface and geometry
    • Basalus MWZ, von Birgelen C,. Benchside testing of drug-eluting stent surface and geometry. Intervent Cardiol 2010; 2: 159-175.
    • (2010) Intervent Cardiol , vol.2 , pp. 159-175
    • Basalus, M.W.Z.1    Von Birgelen, C.2
  • 14
    • 77951749644 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of different drug eluting stents after failed implantation: From nearly undamaged to major damaged polymers
    • Wiemer M, Butz T, Schmidt W, Schmitz KP, Horstkotte D, Langer C,. Scanning electron microscopic analysis of different drug eluting stents after failed implantation: From nearly undamaged to major damaged polymers. Catheter Cardiovasc Interv 2010; 75: 905-911.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 905-911
    • Wiemer, M.1    Butz, T.2    Schmidt, W.3    Schmitz, K.P.4    Horstkotte, D.5    Langer, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.