메뉴 건너뛰기




Volumn 262, Issue 2, 2012, Pages 662-671

Pulmonary nodules: Growth rate assessment in patients by using serial CT and three-dimensional volumetry

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CANCER SCREENING; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; FEMALE; FOLLOW UP; HUMAN; LUNG CANCER; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TUMOR GROWTH; TUMOR LOCALIZATION; TUMOR VOLUME; VOLUMETRY;

EID: 84857385844     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11100878     Document Type: Article
Times cited : (73)

References (49)
  • 1
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomographic screening
    • National Lung Screening Trial Research Team
    • National Lung Screening Trial Research Team, Aberle DR, Adams AM, et al. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 2011;365(5):395-409.
    • (2011) N Engl J Med , vol.365 , Issue.5 , pp. 395-409
    • Aberle, D.R.1    Adams, A.M.2
  • 2
    • 73349107157 scopus 로고    scopus 로고
    • Management of lung nodules detected by volume CT scanning
    • van Klaveren RJ, Oudkerk M, Prokop M, et al. Management of lung nodules detected by volume CT scanning. N Engl J Med 2009;361(23):2221-2229.
    • (2009) N Engl J Med , vol.361 , Issue.23 , pp. 2221-2229
    • Van Klaveren, R.J.1    Oudkerk, M.2    Prokop, M.3
  • 3
    • 34848897496 scopus 로고    scopus 로고
    • Evaluation of patients with pulmonary nodules: When is it lung cancer? ACCP evidence-based clinical practice guidelines (2nd edition)
    • DOI 10.1378/chest.07-1353
    • Gould MK, Fletcher J, Iannettoni MD, et al. Evaluation of patients with pulmonary nodules: when is it lung cancer?-ACCP evidence-based clinical practice guidelines (2nd edition). Chest 2007;132(3 suppl):108S-130S. (Pubitemid 47502803)
    • (2007) Chest , vol.132 , Issue.3 SUPPL.
    • Gould, M.K.1    Fletcher, J.2    Iannettoni, M.D.3    Lynch, W.R.4    Midthun, D.E.5    Naidich, D.P.6    Ost, D.E.7
  • 4
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors
    • European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
    • Therasse P, Arbuck SG, Eisenhauer EA, et al. New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J Natl Cancer Inst 2000;92(3): 205-216.
    • (2000) J Natl Cancer Inst , vol.92 , Issue.3 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 6
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI. Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 2000;217(1):251-256. (Pubitemid 33097610)
    • (2000) Radiology , vol.217 , Issue.1 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3    Zhao, B.4    Henschke, C.I.5
  • 9
    • 0141954913 scopus 로고    scopus 로고
    • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
    • Kostis WJ, Reeves AP, Yankelevitz DF, Henschke CI. Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images. IEEE Trans Med Imaging 2003;22(10): 1259-1274.
    • (2003) IEEE Trans Med Imaging , vol.22 , Issue.10 , pp. 1259-1274
    • Kostis, W.J.1    Reeves, A.P.2    Yankelevitz, D.F.3    Henschke, C.I.4
  • 10
    • 2142812310 scopus 로고    scopus 로고
    • Small Pulmonary Nodules, Reproducibility of Three-dimensional Volumetric Measurement and Estimation of Time to Follow-up CT
    • DOI 10.1148/radiol.2312030553
    • Kostis WJ, Yankelevitz DF, Reeves AP, Fluture SC, Henschke CI. Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 2004; 231(2):446-452. (Pubitemid 38552903)
    • (2004) Radiology , vol.231 , Issue.2 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3    Fluture, S.C.4    Henschke, C.I.5
  • 12
    • 18844382442 scopus 로고    scopus 로고
    • Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy
    • DOI 10.1148/radiol.2353040737
    • Goo JM, Tongdee T, Tongdee R, Yeo K, Hildebolt CF, Bae KT. Volumetric measurement of synthetic lung nodules with multidetector row CT: effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 2005;235(3):850-856. (Pubitemid 40695880)
    • (2005) Radiology , vol.235 , Issue.3 , pp. 850-856
    • Goo, J.M.1    Tongdee, T.2    Tongdee, R.3    Yeo, K.4    Hildebolt, C.F.5    Bae, K.T.6
  • 17
    • 36249024875 scopus 로고    scopus 로고
    • Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT- influence of inspiration level, nodule size, and segmentation performance
    • Gietema HA, Schaefer-Prokop CM, Mali WP, Groenewegen G, Prokop M. Pulmonary nodules: interscan variability of semiautomated volume measurements with multisection CT- influence of inspiration level, nodule size, and segmentation performance. Radiology 2007;245(3):888-894.
    • (2007) Radiology , vol.245 , Issue.3 , pp. 888-894
    • Gietema, H.A.1    Schaefer-Prokop, C.M.2    Mali, W.P.3    Groenewegen, G.4    Prokop, M.5
  • 18
    • 66649123262 scopus 로고    scopus 로고
    • Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation
    • Nietert PJ, Ravenel JG, Leue WM, et al. Imprecision in automated volume measurements of pulmonary nodules and its effect on the level of uncertainty in volume doubling time estimation. Chest 2009;135(6): 1580-1587.
    • (2009) Chest , vol.135 , Issue.6 , pp. 1580-1587
    • Nietert, P.J.1    Ravenel, J.G.2    Leue, W.M.3
  • 19
    • 44449158674 scopus 로고    scopus 로고
    • Pulmonary nodule volume: Effects of reconstruction parameters on automated measurements-a phantom study
    • Ravenel JG, Leue WM, Nietert PJ, Miller JV, Taylor KK, Silvestri GA. Pulmonary nodule volume: effects of reconstruction parameters on automated measurements-a phantom study. Radiology 2008;247(2): 400-408.
    • (2008) Radiology , vol.247 , Issue.2 , pp. 400-408
    • Ravenel, J.G.1    Leue, W.M.2    Nietert, P.J.3    Miller, J.V.4    Taylor, K.K.5    Silvestri, G.A.6
  • 20
    • 40749155455 scopus 로고    scopus 로고
    • Volumetria dei noduli polmonari con metodo automatico in TC multidetettore: Influenza dello spessore di strato, dell'algoritmo di ricostruzione e della corrente del tubo. Risultati preliminari
    • DOI 10.1007/s11547-008-0231-3
    • Larici AR, Storto ML, Torge M, et al. Automated volumetry of pulmonary nodules on multidetector CT: influence of slice thickness, reconstruction algorithm and tube current-preliminary results. Radiol Med (Torino) 2008;113(1):29-42. (Pubitemid 351387214)
    • (2008) Radiologia Medica , vol.113 , Issue.1 , pp. 29-42
    • Larici, A.R.1    Storto, M.L.2    Torge, M.3    Mereu, M.4    Molinari, F.5    Maggi, F.6    Bonomo, L.7
  • 21
    • 33846527920 scopus 로고    scopus 로고
    • Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology
    • DOI 10.2214/AJR.05.1063
    • Petrou M, Quint LE, Nan B, Baker LH. Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology. AJR Am J Roentgenol 2007;188(2):306-312. (Pubitemid 46167729)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.2 , pp. 306-312
    • Petrou, M.1    Quint, L.E.2    Nan, B.3    Baker, L.H.4
  • 22
    • 75749133314 scopus 로고    scopus 로고
    • Variability of semiautomated lung nodule volumetry on ultralow-dose CT: Comparison with nodule volumetry on standard-dose CT
    • Hein PA, Romano VC, Rogalla P, et al. Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT. J Digit Imaging 2010;23(1):8-17.
    • (2010) J Digit Imaging , vol.23 , Issue.1 , pp. 8-17
    • Hein, P.A.1    Romano, V.C.2    Rogalla, P.3
  • 25
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
    • de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M. A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 2009; 19(4):800-808.
    • (2009) Eur Radiol , vol.19 , Issue.4 , pp. 800-808
    • De Hoop, B.1    Gietema, H.2    Van Ginneken, B.3    Zanen, P.4    Groenewegen, G.5    Prokop, M.6
  • 26
    • 67049145084 scopus 로고    scopus 로고
    • Pulmonary nodules: Volume repeatability at multidetector CT lung cancer screening
    • Marchianò A, Calabrò E, Civelli E, et al. Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening. Radiology 2009;251(3):919-925.
    • (2009) Radiology , vol.251 , Issue.3 , pp. 919-925
    • Marchianò, A.1    Calabrò, E.2    Civelli, E.3
  • 27
    • 2442639078 scopus 로고    scopus 로고
    • Lung tumor growth: Assessment with CT - Comparison of diameter and cross-sectional area with volume measurements
    • DOI 10.1148/radiol.2313030715
    • Jennings SG, Winer-Muram HT, Tarver RD, Farber MO. Lung tumor growth: assessment with CT-comparison of diameter and cross-sectional area with volume measurements . Radiology 2004;231(3):866-871. (Pubitemid 38668110)
    • (2004) Radiology , vol.231 , Issue.3 , pp. 866-871
    • Jennings, S.G.1    Winer-Muram, H.T.2    Tarver, R.D.3    Farber, M.O.4
  • 28
    • 10444278156 scopus 로고    scopus 로고
    • Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography
    • DOI 10.1016/j.acra.2004.09.004, PII S1076633204005513
    • Tran LN, Brown MS, Goldin JG, et al. Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography. Acad Radiol 2004;11(12):1355-1360. (Pubitemid 39642822)
    • (2004) Academic Radiology , vol.11 , Issue.12 , pp. 1355-1360
    • Tran, L.N.1    Brown, M.S.2    Goldin, J.G.3    Yan, X.4    Pais, R.C.5    McNitt-Gray, M.F.6    Gjertson, D.7    Rogers, S.R.8    Aberle, D.R.9
  • 29
    • 41949136449 scopus 로고    scopus 로고
    • Automated CT volumetry of pulmonary metastases: The effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria
    • Marten K, Auer F, Schmidt S, Rummeny EJ, Engelke C. Automated CT volumetry of pulmonary metastases: the effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria. Eur Radiol 2007;17(10):2561-2571.
    • (2007) Eur Radiol , vol.17 , Issue.10 , pp. 2561-2571
    • Marten, K.1    Auer, F.2    Schmidt, S.3    Rummeny, E.J.4    Engelke, C.5
  • 30
    • 2142697951 scopus 로고    scopus 로고
    • Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable?
    • DOI 10.1148/radiol.2312030167
    • Revel MP, Bissery A, Bienvenu M, Aycard L, Lefort C, Frija G. Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 2004; 231(2):453-458. (Pubitemid 38552904)
    • (2004) Radiology , vol.231 , Issue.2 , pp. 453-458
    • Revel, M.-P.1    Bissery, A.2    Bienvenu, M.3    Aycard, L.4    Lefort, C.5    Frija, G.6
  • 32
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • DOI 10.2214/AJR.04.1821
    • Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR Am J Roentgenol 2006;186(4):989-994. (Pubitemid 46100197)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.4 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3    Nagy, P.G.4    Piacsek, K.L.5
  • 34
    • 44449167622 scopus 로고    scopus 로고
    • Fully automatic segmentation of the brain from T1-weighted MRI using Bridge Burner algorithm
    • DOI 10.1002/jmri.21372
    • Mikheev A, Nevsky G, Govindan S, Grossman R, Rusinek H. Fully automatic segmentation of the brain from T1-weighted MRI using Bridge Burner algorithm. J Magn Reson Imaging 2008;27(6):1235-1241. (Pubitemid 351770672)
    • (2008) Journal of Magnetic Resonance Imaging , vol.27 , Issue.6 , pp. 1235-1241
    • Mikheev, A.1    Nevsky, G.2    Govindan, S.3    Grossman, R.4    Rusinek, H.5
  • 35
    • 33645115231 scopus 로고    scopus 로고
    • Effect of blood vessels on measurement of nodule volume in a chest phantom
    • Ko JP, Marcus R, Bomsztyk E, et al. Effect of blood vessels on measurement of nodule volume in a chest phantom. Radiology 2006;239(1):79-85.
    • (2006) Radiology , vol.239 , Issue.1 , pp. 79-85
    • Ko, J.P.1    Marcus, R.2    Bomsztyk, E.3
  • 37
    • 67049102265 scopus 로고
    • A biomathematical approach to clinical tumor growth
    • Schwartz M. A biomathematical approach to clinical tumor growth. Cancer 1961;14 : 1272-1294.
    • (1961) Cancer , vol.14 , pp. 1272-1294
    • Schwartz, M.1
  • 39
    • 73149104656 scopus 로고    scopus 로고
    • 5-Year lung cancer screening experience: Growth curves of 18 lung cancers compared to histologic type, CT attenuation, stage, survival, and size
    • Lindell RM, Hartman TE, Swensen SJ, Jett JR, Midthun DE, Mandrekar JN. 5-year lung cancer screening experience: growth curves of 18 lung cancers compared to histologic type, CT attenuation, stage, survival, and size. Chest 2009;136(6):1586-1595.
    • (2009) Chest , vol.136 , Issue.6 , pp. 1586-1595
    • Lindell, R.M.1    Hartman, T.E.2    Swensen, S.J.3    Jett, J.R.4    Midthun, D.E.5    Mandrekar, J.N.6
  • 40
    • 34548672818 scopus 로고    scopus 로고
    • Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons
    • DOI 10.1148/radiol.2451061682
    • Kim HY, Shim YM, Lee KS, Han J, Yi CA, Kim YK. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Radiology 2007; 245(1):267-275. (Pubitemid 47417810)
    • (2007) Radiology , vol.245 , Issue.1 , pp. 267-275
    • Ha, Y.K.1    Young, M.S.2    Kyung, S.L.3    Han, J.4    Yi, C.A.5    Yoon, K.K.6
  • 41
    • 63149126246 scopus 로고    scopus 로고
    • Clinical, pathological and thin-section CT features of persistent multiple groundglass opacity nodules: Comparison with solitary ground-glass opacity nodule
    • Kim TJ, Goo JM, Lee KW, Park CM, Lee HJ. Clinical, pathological and thin-section CT features of persistent multiple groundglass opacity nodules: comparison with solitary ground-glass opacity nodule. Lung Cancer 2009;64(2):171-178.
    • (2009) Lung Cancer , vol.64 , Issue.2 , pp. 171-178
    • Kim, T.J.1    Goo, J.M.2    Lee, K.W.3    Park, C.M.4    Lee, H.J.5
  • 43
    • 52049125464 scopus 로고    scopus 로고
    • Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: Preliminary results
    • Tateishi U, Tsukagoshi S, Inokawa H, Okumura M, Moriyama N. Fluctuation in measurements of pulmonary nodule under tidal volume ventilation on four-dimensional computed tomography: preliminary results. Eur Radiol 2008;18(10):2132-2139.
    • (2008) Eur Radiol , vol.18 , Issue.10 , pp. 2132-2139
    • Tateishi, U.1    Tsukagoshi, S.2    Inokawa, H.3    Okumura, M.4    Moriyama, N.5
  • 44
    • 33845459604 scopus 로고    scopus 로고
    • Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume
    • DOI 10.3348/kjr.2006.7.4.243
    • Goo JM, Kim KG, Gierada DS, Castro M, Bae KT. Volumetric measurements of lung nodules with multi-detector row CT: effect of changes in lung volume. Korean J Radiol 2006;7(4):243-248. (Pubitemid 44905082)
    • (2006) Korean Journal of Radiology , vol.7 , Issue.4 , pp. 243-248
    • Goo, J.M.1    Kim, K.G.2    Gierada, D.S.3    Castro, M.4    Bae, K.T.5
  • 46
    • 77950382456 scopus 로고    scopus 로고
    • Part-solid nodules: Two steps forward
    • Naidich DP. Part-solid nodules: two steps forward.... Radiology 2010;255(1):16-18.
    • (2010) Radiology , vol.255 , Issue.1 , pp. 16-18
    • Naidich, D.P.1
  • 48
    • 67049132429 scopus 로고    scopus 로고
    • In vivo repeatability of automated volume calculations of small pulmonary nodules with CT
    • Rampinelli C, De Fiori E, Raimondi S, Veronesi G, Bellomi M. In vivo repeatability of automated volume calculations of small pulmonary nodules with CT. AJR Am J Roentgenol 2009;192(6):1657-1661.
    • (2009) AJR Am J Roentgenol , vol.192 , Issue.6 , pp. 1657-1661
    • Rampinelli, C.1    De Fiori, E.2    Raimondi, S.3    Veronesi, G.4    Bellomi, M.5
  • 49
    • 77952091413 scopus 로고    scopus 로고
    • Volumetric measurement of pulmonary nodules at low-dose chest CT: Effect of reconstruction setting on measurement variability
    • Wang Y, de Bock GH, van Klaveren RJ, et al. Volumetric measurement of pulmonary nodules at low-dose chest CT: effect of reconstruction setting on measurement variability . Eur Radiol 2010;20(5):1180-1187.
    • (2010) Eur Radiol , vol.20 , Issue.5 , pp. 1180-1187
    • Wang, Y.1    De Bock, G.H.2    Van Klaveren, R.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.