메뉴 건너뛰기




Volumn 81, Issue 3, 2012, Pages

Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values

Author keywords

Computed tomography; Dual energy; Image reconstruction; Tissue attenuation measurements; Virtual non contrast

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ASSESSMENT; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; DUAL ENERGY COMPUTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RELIABILITY;

EID: 84856952691     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.12.011     Document Type: Article
Times cited : (149)

References (21)
  • 1
    • 58949099700 scopus 로고    scopus 로고
    • Dual-energy and dual-source CT: Is there a role in the abdomen and pelvis?
    • J.G. Fletcher, N. Takahashi, and R. Hartman Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin North Am 47 1 2009 41 57
    • (2009) Radiol Clin North Am , vol.47 , Issue.1 , pp. 41-57
    • Fletcher, J.G.1    Takahashi, N.2    Hartman, R.3
  • 2
    • 59249098264 scopus 로고    scopus 로고
    • Dual energy CT: Preliminary observations and potential clinical applications in the abdomen
    • A. Graser, T.R. Johnson, H. Chandarana, and M. Macari Dual energy CT: preliminary observations and potential clinical applications in the abdomen Eur Radiol 19 1 2009 13 23
    • (2009) Eur Radiol , vol.19 , Issue.1 , pp. 13-23
    • Graser, A.1    Johnson, T.R.2    Chandarana, H.3    MacAri, M.4
  • 3
    • 77957708674 scopus 로고    scopus 로고
    • Dual-energy multidetector CT: How does it work, what can it tell us, and when can we use it in abdominopelvic imaging?
    • C.A. Coursey, R.C. Nelson, and D.T. Boll Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 30 4 2010 1037 1055
    • (2010) Radiographics , vol.30 , Issue.4 , pp. 1037-1055
    • Coursey, C.A.1    Nelson, R.C.2    Boll, D.T.3
  • 4
    • 61349119238 scopus 로고    scopus 로고
    • Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    • L. Yu, A.N. Primak, X. Liu, and C.H. McCollough Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT Med Phys 36 3 2009 1019 1024
    • (2009) Med Phys , vol.36 , Issue.3 , pp. 1019-1024
    • Yu, L.1    Primak, A.N.2    Liu, X.3    McCollough, C.H.4
  • 5
    • 70249111173 scopus 로고    scopus 로고
    • Dual-energy CT in patients suspected of having renal masses: Can virtual nonenhanced images replace true nonenhanced images?
    • A. Graser, T.R. Johnson, and E.M. Hecht Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 252 2 2009 433 440
    • (2009) Radiology , vol.252 , Issue.2 , pp. 433-440
    • Graser, A.1    Johnson, T.R.2    Hecht, E.M.3
  • 6
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: Initial experience
    • T.R. Johnson, B. Krauss, and M. Sedlmair Material differentiation by dual energy CT: initial experience Eur Radiol 17 6 2007 1510 1517
    • (2007) Eur Radiol , vol.17 , Issue.6 , pp. 1510-1517
    • Johnson, T.R.1    Krauss, B.2    Sedlmair, M.3
  • 7
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • T.G. Flohr, C.H. McCollough, and H. Bruder First performance evaluation of a dual-source CT (DSCT) system Eur Radiol 16 2 2006 256 268
    • (2006) Eur Radiol , vol.16 , Issue.2 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 8
    • 65349110338 scopus 로고    scopus 로고
    • Image fusion in dual energy computed tomography: Effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography
    • F.F. Behrendt, B. Schmidt, and C. Plumhans Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography Invest Radiol 44 1 2009 1 6
    • (2009) Invest Radiol , vol.44 , Issue.1 , pp. 1-6
    • Behrendt, F.F.1    Schmidt, B.2    Plumhans, C.3
  • 9
    • 79951948387 scopus 로고    scopus 로고
    • Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study
    • C. Karlo, A. Lauber, and R.P. Gotti Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study Eur Radiol 21 2 2011 385 392
    • (2011) Eur Radiol , vol.21 , Issue.2 , pp. 385-392
    • Karlo, C.1    Lauber, A.2    Gotti, R.P.3
  • 10
    • 43149112505 scopus 로고    scopus 로고
    • International Commission On Radiological Protection Published for the International Commission on Radiological Protection by Elsevier Oxford, England
    • J. Valentin, and International Commission on Radiological Protection The 2007 recommendations of the International Commission on Radiological Protection 2007 Published for the International Commission on Radiological Protection by Elsevier Oxford, England
    • (2007) The 2007 Recommendations of the International Commission on Radiological Protection
    • Valentin, J.1
  • 12
    • 0035406964 scopus 로고    scopus 로고
    • Cystic focal liver lesions in the adult: Differential CT and MR imaging features
    • K.J. Mortele, and P.R. Ros Cystic focal liver lesions in the adult: differential CT and MR imaging features Radiographics 21 4 2001 895 910
    • (2001) Radiographics , vol.21 , Issue.4 , pp. 895-910
    • Mortele, K.J.1    Ros, P.R.2
  • 13
    • 0030186799 scopus 로고    scopus 로고
    • Problems in the detection and characterization of small renal masses
    • M.A. Bosniak, and N.M. Rofsky Problems in the detection and characterization of small renal masses Radiology 200 1 1996 286 287
    • (1996) Radiology , vol.200 , Issue.1 , pp. 286-287
    • Bosniak, M.A.1    Rofsky, N.M.2
  • 14
    • 77449127465 scopus 로고    scopus 로고
    • Diffuse liver disease: Strategies for hepatic CT and MR imaging
    • D.T. Boll, and E.M. Merkle Diffuse liver disease: strategies for hepatic CT and MR imaging Radiographics 29 6 2009 1591 1614
    • (2009) Radiographics , vol.29 , Issue.6 , pp. 1591-1614
    • Boll, D.T.1    Merkle, E.M.2
  • 15
    • 67650739223 scopus 로고    scopus 로고
    • Beam hardening correction in CT myocardial perfusion measurement
    • A. So, J. Hsieh, J.Y. Li, and T.Y. Lee Beam hardening correction in CT myocardial perfusion measurement Phys Med Biol 54 10 2009 3031 3050
    • (2009) Phys Med Biol , vol.54 , Issue.10 , pp. 3031-3050
    • So, A.1    Hsieh, J.2    Li, J.Y.3    Lee, T.Y.4
  • 16
    • 33845621446 scopus 로고    scopus 로고
    • Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom
    • B.A. Birnbaum, N. Hindman, J. Lee, and J.S. Babb Multi-detector row CT attenuation measurements: assessment of intra- and interscanner variability with an anthropomorphic body CT phantom Radiology 242 1 2007 109 119
    • (2007) Radiology , vol.242 , Issue.1 , pp. 109-119
    • Birnbaum, B.A.1    Hindman, N.2    Lee, J.3    Babb, J.S.4
  • 17
    • 78650303464 scopus 로고    scopus 로고
    • Dual energy CT (DECT) of the liver: Conventional versus virtual unenhanced images
    • C.N. De Cecco, V. Buffa, and S. Fedeli Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images Eur Radiol 20 12 2010 2870 2875
    • (2010) Eur Radiol , vol.20 , Issue.12 , pp. 2870-2875
    • De Cecco, C.N.1    Buffa, V.2    Fedeli, S.3
  • 18
    • 77950604342 scopus 로고    scopus 로고
    • Estimating effective dose for CT using dose-length product compared with using organ doses: Consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning
    • J.A. Christner, J.M. Kofler, and C.H. McCollough Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning AJR 194 4 2010 881 889
    • (2010) AJR , vol.194 , Issue.4 , pp. 881-889
    • Christner, J.A.1    Kofler, J.M.2    McCollough, C.H.3
  • 19
    • 0024070365 scopus 로고
    • An algorithm for noise suppression in dual energy CT material density images
    • W.A. Kalender, E. Klotz, and L. Kostaridou An algorithm for noise suppression in dual energy CT material density images IEEE Trans Med Imaging 7 3 1988 218 224
    • (1988) IEEE Trans Med Imaging , vol.7 , Issue.3 , pp. 218-224
    • Kalender, W.A.1    Klotz, E.2    Kostaridou, L.3
  • 21
    • 77953258040 scopus 로고    scopus 로고
    • Dual-energy CT for characterization of adrenal nodules: Initial experience
    • R.T. Gupta, L.M. Ho, D. Marin, D.T. Boll, H.X. Barnhart, and R.C. Nelson Dual-energy CT for characterization of adrenal nodules: initial experience AJR 194 6 2010 1479 1483
    • (2010) AJR , vol.194 , Issue.6 , pp. 1479-1483
    • Gupta, R.T.1    Ho, L.M.2    Marin, D.3    Boll, D.T.4    Barnhart, H.X.5    Nelson, R.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.