Incorporation of optical enzymatic sensing chemistry into biocompatible hydrogels

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTES; BIOCOMPATIBLE MATERIALS; CONTINUOUS MONITORING; HYDROGEL SYSTEM; LUMINOPHORES; NON-INVASIVE; OPTICAL SENSING SYSTEMS; OXIDATIVE ENZYMES; PH SENSITIVE; POLY(2-HYDROXYETHYL METHACRYLATE); RESPONSE PROFILE; SENSOR RESPONSE;

EID: 84856908727     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICSENS.2011.6127127     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 2
    • 33847217294 scopus 로고    scopus 로고
    • Microscale enzymatic optical biosensors using mass transport limiting nanofilms. 1. Fabrication and characterization using glucose as a model analyte
    • Stein, E.W., Grant, P.S., Zhu, H., McShane, M.J., "Microscale enzymatic optical biosensors using mass transport limiting nanofilms. 1. Fabrication and characterization using glucose as a model analyte, "Analytical Chemistry, vol. 29, pp. 1339-1348, 2007
    • (2007) Analytical Chemistry , vol.29 , pp. 1339-1348
    • Stein, E.W.1    Grant, P.S.2    Zhu, H.3    McShane, M.J.4
  • 3
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • Clark, L.C., Lyons, C. "Electrode systems for continuous monitoring in cardiovascular surgery." Ann. NY Acad. Sci. vol 102, pp. 29-45, 1962
    • (1962) Ann. NY Acad. Sci. Vol , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 4
    • 0033051709 scopus 로고    scopus 로고
    • Performance of subcutaneously implanted glucose sensors for continuous monitoring
    • DOI 10.1016/S0300-2977(99)00006-6, PII S0300297799000066
    • Gerritsen, M., Jansen, J.A., Lutterman, J.A., "Performance of subcutaneous implanted glucose sensors for continuous monitoring. "Netherlands Journal of Medicine. vol 54, pp. 167-179, 1999 (Pubitemid 29148078)
    • (1999) Netherlands Journal of Medicine , vol.54 , Issue.4 , pp. 167-179
    • Gerritsen, M.1    Jansen, J.A.2    Lutterman, J.A.3
  • 5
    • 0021062169 scopus 로고
    • Macroporous hydrogel membranes for a hybrid artiicial pancreas. II. Biocompatibility
    • Klomp, G.F., Hashiguchi, H., Ursell, P.C., Takeda, Y., Taguchi, T., Dobelle, W.H., "Macroporous hydrogel membranes for a hybrid artificial pancreas. Part II. Biocompatibility." J. Biomed. Mater. Res, vol. 17, pp. 865-871, 1983 (Pubitemid 14225821)
    • (1983) Journal of Biomedical Materials Research , vol.17 , Issue.5 , pp. 865-871
    • Klomp, G.F.1    Hashiguchi, H.2    Ursell, P.C.3
  • 6
    • 0002770914 scopus 로고
    • Synthetic hydrogels for biomedical applications
    • J.D. Andrade, Ed.Washington D.C
    • Ratner, B.D., Hoffman, A.S., "Synthetic hydrogels for biomedical applications." in: Hydrogels for Medical and Related Application. J.D. Andrade, Ed.Washington D.C, 1976, pp.1-36
    • (1976) Hydrogels for Medical and Related Application , pp. 1-36
    • Ratner, B.D.1    Hoffman, A.S.2
  • 7
    • 78649444560 scopus 로고
    • Hydrogels from 2-hydroxyethyl methacrylate and propylene glycol monoacrylate
    • Refojo, M. F., Yasuda, H., "Hydrogels from 2-hydroxyethyl methacrylate and propylene glycol monoacrylate." J. Appl. Polym. Sci., vol. 9 (7), pp. 2425-2435, 1965
    • (1965) J. Appl. Polym. Sci. , vol.9 , Issue.7 , pp. 2425-2435
    • Refojo, M.F.1    Yasuda, H.2
  • 8
    • 0009772002 scopus 로고
    • Hydrogels of poly(hydroxyethyl methacrylate) and hydroxyethyl methacrylate - Glycerol monomethacry-late copolymers
    • Yasuda, H., Gochin, M., Stone, W., "Hydrogels of poly(hydroxyethyl methacrylate) and hydroxyethyl methacrylate - glycerol monomethacry-late copolymers." J. Polym. Sci. A. vol 1 (4), pp. 2913- 2927. 1966
    • (1966) J. Polym. Sci. A. , vol.1 , Issue.4 , pp. 2913-2927
    • Yasuda, H.1    Gochin, M.2    Stone, W.3
  • 9
    • 0023441129 scopus 로고
    • Immobilization of glucose oxidase on pHEMA membranes
    • Arica, Y.M., Hasirci, V., "Immobilization of glucose oxidase on pHEMA membranes." Biomaterials. vol. 8, pp. 489-495. 1987
    • (1987) Biomaterials. , vol.8 , pp. 489-495
    • Arica, Y.M.1    Hasirci, V.2
  • 10
    • 71849083396 scopus 로고    scopus 로고
    • Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation
    • Singh, S., McShane, M. J., "Enhancing the longevity of microparticle-based glucose sensors towards 1 month continuous operation,"Biosensors and Bioelectronics, vol 25 (5), pp.1075-1081, 2009
    • (2009) Biosensors and Bioelectronics , vol.25 , Issue.5 , pp. 1075-1081
    • Singh, S.1    McShane, M.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.