메뉴 건너뛰기




Volumn 40, Issue 1, 2012, Pages

Biocompatibility and retinal support of a foldable capsular vitreous body injected with saline or silicone oil implanted in rabbit eyes

Author keywords

Biocompatibility; Complication; Foldable capsular vitreous body; Silicone oil; Vitreous substitute

Indexed keywords

SILICONE OIL; SODIUM CHLORIDE;

EID: 84856656681     PISSN: 14426404     EISSN: 14429071     Source Type: Journal    
DOI: 10.1111/j.1442-9071.2011.02664.x     Document Type: Article
Times cited : (29)

References (31)
  • 2
    • 0022849370 scopus 로고
    • Early anterior segment complications after silicone oil injection
    • Pang MP, Peyman GA, Kao GW. Early anterior segment complications after silicone oil injection. Can J Ophthalmol 1986; 21: 271-5.
    • (1986) Can J Ophthalmol , vol.21 , pp. 271-275
    • Pang, M.P.1    Peyman, G.A.2    Kao, G.W.3
  • 3
    • 0023949344 scopus 로고
    • Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery
    • Federman JL, Schubert HD. Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery. Ophthalmology 1988; 95: 870-6.
    • (1988) Ophthalmology , vol.95 , pp. 870-876
    • Federman, J.L.1    Schubert, H.D.2
  • 4
    • 0028608895 scopus 로고
    • Emulsified anterior chamber silicone oil and glaucoma
    • Valone J Jr, McCarthy M. Emulsified anterior chamber silicone oil and glaucoma. Ophthalmology 1994; 101: 1908-12.
    • (1994) Ophthalmology , vol.101 , pp. 1908-1912
    • Valone Jr, J.1    McCarthy, M.2
  • 5
    • 0034068457 scopus 로고    scopus 로고
    • Migration of silicone oil into the brain: a complication of intraocular silicone oil for retinal tamponade
    • Eller AW, Friberg TR, Mah F. Migration of silicone oil into the brain: a complication of intraocular silicone oil for retinal tamponade. Am J Ophthalmol 2000; 129: 685-8.
    • (2000) Am J Ophthalmol , vol.129 , pp. 685-688
    • Eller, A.W.1    Friberg, T.R.2    Mah, F.3
  • 9
    • 0035047918 scopus 로고    scopus 로고
    • Results and complications of temporary silicone oil tamponade in patients with complicated retinal detachments
    • La Heij EC, Hendrikse F, Kessels AG. Results and complications of temporary silicone oil tamponade in patients with complicated retinal detachments. Retina 2001; 21: 107-14.
    • (2001) Retina , vol.21 , pp. 107-114
    • La Heij, E.C.1    Hendrikse, F.2    Kessels, A.G.3
  • 10
    • 34248329166 scopus 로고    scopus 로고
    • In vivo retinal tolerance of various heavy silicone oils
    • Mackiewicz J, Mühling B, Hiebl W etal. In vivo retinal tolerance of various heavy silicone oils. Invest Ophthalmol Vis Sci 2007; 48: 1873-83.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 1873-1883
    • Mackiewicz, J.1    Mühling, B.2    Hiebl, W.3
  • 11
    • 34447129332 scopus 로고    scopus 로고
    • High-density silicone oil (Densiron) as a primary intraocular tamponade: 12-month follow up
    • Sandner D, Herbrig E, Engelmann K. High-density silicone oil (Densiron) as a primary intraocular tamponade: 12-month follow up. Graefes Arch Clin Exp Ophthalmol 2007; 245: 1097-105.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , pp. 1097-1105
    • Sandner, D.1    Herbrig, E.2    Engelmann, K.3
  • 12
    • 38349167652 scopus 로고    scopus 로고
    • Emulsification of Densiron-68 used in inferior retinal detachment surgery
    • Majid MA, Hussin HM, Biswas S, Haynes RJ, Mayer EJ, Dick AD. Emulsification of Densiron-68 used in inferior retinal detachment surgery. Eye 2008; 22: 152-7.
    • (2008) Eye , vol.22 , pp. 152-157
    • Majid, M.A.1    Hussin, H.M.2    Biswas, S.3    Haynes, R.J.4    Mayer, E.J.5    Dick, A.D.6
  • 13
    • 77955550907 scopus 로고    scopus 로고
    • Long-term outcomes of Oxane Hd as intraocular tamponade in the treatment of complicated retinal detachment
    • Meng Q, Zhang S, Cheng H, Chen X, Jin Y. Long-term outcomes of Oxane Hd as intraocular tamponade in the treatment of complicated retinal detachment. Graefes Arch Clin Exp Ophthalmol 2010; 248: 1091-6.
    • (2010) Graefes Arch Clin Exp Ophthalmol , vol.248 , pp. 1091-1096
    • Meng, Q.1    Zhang, S.2    Cheng, H.3    Chen, X.4    Jin, Y.5
  • 14
    • 0029447052 scopus 로고
    • The use of Fourier transform infrared spectrometry for monitoring the retention of polymers in the vitreous humour
    • Dalton PD, Jefferson A, Hong Y, Chirila TV, Vijayasekaran S, Tahija SG. The use of Fourier transform infrared spectrometry for monitoring the retention of polymers in the vitreous humour. Biomed Mater Eng 1995; 5: 185-93.
    • (1995) Biomed Mater Eng , vol.5 , pp. 185-193
    • Dalton, P.D.1    Jefferson, A.2    Hong, Y.3    Chirila, T.V.4    Vijayasekaran, S.5    Tahija, S.G.6
  • 15
    • 0032521520 scopus 로고    scopus 로고
    • Biodegradation in vitro and retention in the rabbit eye of crosslinked poly(1-vinyl-2-pyrrolidinone) hydrogel as a vitreous substitute
    • Hong Y, Chirila TV, Vijayasekaran S, Shen W, Lou X, Dalton PD. Biodegradation in vitro and retention in the rabbit eye of crosslinked poly(1-vinyl-2-pyrrolidinone) hydrogel as a vitreous substitute. J Biomed Mater Res 1998; 39: 650-9.
    • (1998) J Biomed Mater Res , vol.39 , pp. 650-659
    • Hong, Y.1    Chirila, T.V.2    Vijayasekaran, S.3    Shen, W.4    Lou, X.5    Dalton, P.D.6
  • 16
    • 0031944482 scopus 로고    scopus 로고
    • Biocompatibility of polyvinylalcohol gel as a vitreous substitute
    • Hara Y, Matsuura T, Taketani F etal. Biocompatibility of polyvinylalcohol gel as a vitreous substitute. Nippon Ganka Gakkai Zasshi 1998; 102: 247-55.
    • (1998) Nippon Ganka Gakkai Zasshi , vol.102 , pp. 247-255
    • Hara, Y.1    Matsuura, T.2    Taketani, F.3
  • 17
    • 33746821873 scopus 로고    scopus 로고
    • Biocompatibility of polyvinylalcohol gel as a vitreous substitute
    • Maruoka S, Matsuura T, Kawasaki K etal. Biocompatibility of polyvinylalcohol gel as a vitreous substitute. Curr Eye Res 2006; 31: 599-06.
    • (2006) Curr Eye Res , vol.31 , pp. 599-506
    • Maruoka, S.1    Matsuura, T.2    Kawasaki, K.3
  • 19
    • 0037222681 scopus 로고    scopus 로고
    • Artificial vitreous replacements
    • Soman N, Banerjee R. Artificial vitreous replacements. Biomed Mater Eng 2003; 13: 59-74.
    • (2003) Biomed Mater Eng , vol.13 , pp. 59-74
    • Soman, N.1    Banerjee, R.2
  • 20
    • 84871483456 scopus 로고    scopus 로고
    • Vitrectomy: in search of the ideal vitreous replacement
    • Steijns D, Stilma JS. Vitrectomy: in search of the ideal vitreous replacement. Ned Tijdschr Geneeskd 2009; 153: A433.
    • (2009) Ned Tijdschr Geneeskd , vol.153
    • Steijns, D.1    Stilma, J.S.2
  • 21
    • 40949086475 scopus 로고    scopus 로고
    • A new strategy to replace the natural vitreous by a novel capsular artificial vitreous body with pressure-control valve
    • Gao Q, Mou S, Ge J etal. A new strategy to replace the natural vitreous by a novel capsular artificial vitreous body with pressure-control valve. Eye 2008; 22: 461-8.
    • (2008) Eye , vol.22 , pp. 461-468
    • Gao, Q.1    Mou, S.2    Ge, J.3
  • 22
    • 79953781961 scopus 로고    scopus 로고
    • Clinical device-related article evaluation of morphology and functions of a foldable capsular vitreous body in the rabbit eye
    • Chen J, Gao Q, Liu Y etal. Clinical device-related article evaluation of morphology and functions of a foldable capsular vitreous body in the rabbit eye. J Biomed Mater Res B Appl Biomater 2011; 97: 396-404.
    • (2011) J Biomed Mater Res B Appl Biomater , vol.97 , pp. 396-404
    • Chen, J.1    Gao, Q.2    Liu, Y.3
  • 23
    • 79952276031 scopus 로고    scopus 로고
    • Evaluation of the flexibility, efficacy, and safety of a foldable capsular vitreous body in the treatment of severe retinal detachment
    • Lin X, Ge J, Gao Q etal. Evaluation of the flexibility, efficacy, and safety of a foldable capsular vitreous body in the treatment of severe retinal detachment. Invest Ophthalmol Vis Sci 2011; 52: 374-81.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 374-381
    • Lin, X.1    Ge, J.2    Gao, Q.3
  • 24
    • 77958579775 scopus 로고    scopus 로고
    • Technical standards of a foldable capsular vitreous body in terms of mechanical, optical, and biocompatible properties
    • Liu Y, Jiang Z, Gao Q etal. Technical standards of a foldable capsular vitreous body in terms of mechanical, optical, and biocompatible properties. Artif Organs 2010; 34: 836-45.
    • (2010) Artif Organs , vol.34 , pp. 836-845
    • Liu, Y.1    Jiang, Z.2    Gao, Q.3
  • 25
    • 67649989568 scopus 로고    scopus 로고
    • Refractive shifts in four selected artificial vitreous substitutes based on Gullstrand-Emsley and Liou-Brennan schematic eyes
    • Gao Q, Chen X, Ge J etal. Refractive shifts in four selected artificial vitreous substitutes based on Gullstrand-Emsley and Liou-Brennan schematic eyes. Invest Ophthalmol Vis Sci 2009; 50: 3529-34.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 3529-3534
    • Gao, Q.1    Chen, X.2    Ge, J.3
  • 26
    • 0023090477 scopus 로고
    • Effect of silicone oil viscosity on emulsification
    • Crisp A, de Juan E Jr, Tiedeman J. Effect of silicone oil viscosity on emulsification. Arch Ophthalmol 1987; 105: 546-50.
    • (1987) Arch Ophthalmol , vol.105 , pp. 546-550
    • Crisp, A.1    de Juan Jr, E.2    Tiedeman, J.3
  • 27
    • 0025273922 scopus 로고
    • Factors contributing to the emulsification of intraocular silicone and fluorosilicone oils
    • Nakamura K, Refojo MF, Crabtree DV. Factors contributing to the emulsification of intraocular silicone and fluorosilicone oils. Invest Ophthalmol Vis Sci 1990; 31: 647-56.
    • (1990) Invest Ophthalmol Vis Sci , vol.31 , pp. 647-656
    • Nakamura, K.1    Refojo, M.F.2    Crabtree, D.V.3
  • 28
    • 76749134770 scopus 로고    scopus 로고
    • Increasing the extensional viscosity of silicone oil reduces the tendency for emulsification
    • Williams RL, Day M, Garvey MJ, English R, Wong D. Increasing the extensional viscosity of silicone oil reduces the tendency for emulsification. Retina 2010; 30: 300-4.
    • (2010) Retina , vol.30 , pp. 300-304
    • Williams, R.L.1    Day, M.2    Garvey, M.J.3    English, R.4    Wong, D.5
  • 29
    • 0030459690 scopus 로고    scopus 로고
    • Role of blood components in ocular silicone oil emulsification. Studies on an in vitro model
    • Savion N, Alhalel A, Treister G, Bartov E. Role of blood components in ocular silicone oil emulsification. Studies on an in vitro model. Invest Ophthalmol Vis Sci 1996; 37: 2694-9.
    • (1996) Invest Ophthalmol Vis Sci , vol.37 , pp. 2694-2699
    • Savion, N.1    Alhalel, A.2    Treister, G.3    Bartov, E.4
  • 30
    • 0034962202 scopus 로고    scopus 로고
    • The biocompatibility of silicone, fluorosilicone and perfluorocarbon liquids as vitreous tamponades. an ultrastructural and immunohistochemical study
    • Versura P, Cellini M, Torreggiani A etal. The biocompatibility of silicone, fluorosilicone and perfluorocarbon liquids as vitreous tamponades. an ultrastructural and immunohistochemical study. Ophthalmologica 2001; 215: 276-83.
    • (2001) Ophthalmologica , vol.215 , pp. 276-283
    • Versura, P.1    Cellini, M.2    Torreggiani, A.3
  • 31
    • 77949888403 scopus 로고    scopus 로고
    • Sustained mechanical release of dexamethasone sodium phosphate from a foldable capsular vitreous body
    • Liu Y, Ke Q, Chen J etal. Sustained mechanical release of dexamethasone sodium phosphate from a foldable capsular vitreous body. Invest Ophthalmol Vis Sci 2010; 51: 1636-42.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 1636-1642
    • Liu, Y.1    Ke, Q.2    Chen, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.