메뉴 건너뛰기




Volumn 30, Issue 2, 2010, Pages 300-304

Increasing the extensional viscosity of silicone oil reduces the tendency for emulsification

Author keywords

Emulsification; Extensional viscosity; Newtonian fluid; Oil droplets; Poly(dimethyl siloxane); Retinal detachment; Shear viscosity; Silicone oil; Tamponade agents; Viscoelastic fluid

Indexed keywords

DIMETICONE; POLOXAMER; SILICONE OIL; STABILIZING AGENT;

EID: 76749134770     PISSN: 0275004X     EISSN: None     Source Type: Journal    
DOI: 10.1097/IAE.0b013e3181babe0c     Document Type: Article
Times cited : (58)

References (16)
  • 1
    • 0031761967 scopus 로고    scopus 로고
    • Silicone oil in the repair of complex retinal detachments. A prospective observational multicenter study
    • Azen SP, Scott IU, Flynn HW Jr, et al. Silicone oil in the repair of complex retinal detachments. A prospective observational multicenter study. Ophthalmology 1998;105:1587-1597.
    • (1998) Ophthalmology , vol.105 , pp. 1587-1597
    • Azen, S.P.1    Scott, I.U.2    Flynn Jr., H.W.3
  • 3
    • 0028608895 scopus 로고
    • Emulsified anterior chamber silicone oil and glaucoma
    • Valone J Jr, McCarthy M. Emulsified anterior chamber silicone oil and glaucoma. Ophthalmology 1994;101:1908-1912.
    • (1994) Ophthalmology , vol.101 , pp. 1908-1912
    • Valone Jr., J.1    McCarthy, M.2
  • 5
    • 0029665657 scopus 로고    scopus 로고
    • Recurrent vitreoretinal membranes in intravitreal silicone oil tamponade. Morphologic and immunohistochemical studies
    • Heidenkummer HP, Messmer EM, Kampik A. Recurrent vitreoretinal membranes in intravitreal silicone oil tamponade. Morphologic and immunohistochemical studies. Ophthalmologe 1996; 93:121-125.
    • (1996) Ophthalmologe , vol.93 , pp. 121-125
    • Heidenkummer, H.P.1    Messmer, E.M.2    Kampik, A.3
  • 6
    • 33747883628 scopus 로고    scopus 로고
    • Silicone oil emulsification in the anterior chamber after vitreoretinal surgery
    • Light DJ. Silicone oil emulsification in the anterior chamber after vitreoretinal surgery. Optometry 2006;77:446-449.
    • (2006) Optometry , vol.77 , pp. 446-449
    • Light, D.J.1
  • 7
    • 0036672656 scopus 로고    scopus 로고
    • Correlation between quantity of silicone oil emulsified in the anterior chamber and high pressure in vitrectomized eyes
    • Avitabile T, Bonfiglio V, Cicero A, Torrisi B, Reibaldi A. Correlation between quantity of silicone oil emulsified in the anterior chamber and high pressure in vitrectomized eyes. Retina 2002;22:443-448.
    • (2002) Retina , vol.22 , pp. 443-448
    • Avitabile, T.1    Bonfiglio, V.2    Cicero, A.3    Torrisi, B.4    Reibaldi, A.5
  • 8
    • 0023090477 scopus 로고
    • Effect of silicone oil viscosity on emulsification
    • Crisp A, de Juan E Jr, Tiedeman J. Effect of silicone oil viscosity on emulsification. Arch Ophthalmol 1987;105:546-550.
    • (1987) Arch Ophthalmol , vol.105 , pp. 546-550
    • Crisp, A.1    De Juan Jr., E.2    Tiedeman, J.3
  • 9
    • 17144407215 scopus 로고    scopus 로고
    • Fourier transform infrared and 1h nuclear magnetic resonance spectroscopic findings of silicone oil removed from eyes and the relationship of emulsification with retinotomy and glaucoma
    • Güngel H, Menceog?lu Y, Yildiz B, Akbulut O. Fourier transform infrared and 1h nuclear magnetic resonance spectroscopic findings of silicone oil removed from eyes and the relationship of emulsification with retinotomy and glaucoma. Retina 2005;25:332-338.
    • (2005) Retina , vol.25 , pp. 332-338
    • Güngel, H.1    Menceog̀lu, Y.2    Yildiz, B.3    Akbulut, O.4
  • 10
    • 27744569556 scopus 로고    scopus 로고
    • An experimental study on the effect of encircling band procedure on silicone oil emulsification
    • de Silva DJ, Lim KS, Schulenburg WE. An experimental study on the effect of encircling band procedure on silicone oil emulsification. Br J Ophthalmol 2005;89:1348-1350.
    • (2005) Br J Ophthalmol , vol.89 , pp. 1348-1350
    • De Silva, D.J.1    Lim, K.S.2    Schulenburg, W.E.3
  • 11
    • 33947136361 scopus 로고    scopus 로고
    • Outcomes of transconjunctival sutureless 25-gauge vitrectomy with silicone oil infusion
    • Riemann CD, Miller DM, Foster RE, Petersen MR. Outcomes of transconjunctival sutureless 25-gauge vitrectomy with silicone oil infusion. Retina 2007;27:296-303.
    • (2007) Retina , vol.27 , pp. 296-303
    • Riemann, C.D.1    Miller, D.M.2    Foster, R.E.3    Petersen, M.R.4
  • 12
    • 51149114590 scopus 로고    scopus 로고
    • Shear and extensional rheometry of PDMS tamponade agents used in vitreoretinal surgery
    • Day M, Blanchard R-L, English R, et al. Shear and extensional rheometry of PDMS tamponade agents used in vitreoretinal surgery. AIP Conference Proceedings 2008;1072:1411-1413.
    • (2008) AIP Conference Proceedings , vol.1072 , pp. 1411-1413
    • Day, M.1    Blanchard, R.-L.2    English, R.3
  • 13
    • 0000517616 scopus 로고
    • On the instability of a cylindrical thread of a viscous liquid surrounded by another viscous fluid
    • Tomotika S. On the instability of a cylindrical thread of a viscous liquid surrounded by another viscous fluid. Proc R Soc Lond A 1935;150:322-337.
    • (1935) Proc R Soc Lond A , vol.150 , pp. 322-337
    • Tomotika, S.1
  • 14
    • 4544323859 scopus 로고    scopus 로고
    • Beads-on-string phenomena in wormlike micellar fluids
    • Sostarecz MC, Belmonte A. Beads-on-string phenomena in wormlike micellar fluids. Phys Fluids 2004;16:L67-L70.
    • (2004) Phys Fluids , vol.16
    • Sostarecz, M.C.1    Belmonte, A.2
  • 15
    • 44649183471 scopus 로고    scopus 로고
    • Capillary threads and viscous droplets in square microchannels
    • Cubaud T, Mason TG. Capillary threads and viscous droplets in square microchannels. Phys Fluids 2008;20:1-11.
    • (2008) Phys Fluids , vol.20 , pp. 1-11
    • Cubaud, T.1    Mason, T.G.2
  • 16
    • 34547824100 scopus 로고    scopus 로고
    • Dynamics of viscoelastic fluid filaments in microfluidic devices
    • Steinhaus B, Shen AQ, Sureshkumar R. Dynamics of viscoelastic fluid filaments in microfluidic devices. Phys Fluids 2007;19:1-13
    • (2007) Phys Fluids , vol.19 , pp. 1-13
    • Steinhaus, B.1    Shen, A.Q.2    Sureshkumar, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.