Volumn 52, Issue 10, 2011, Pages 7523-7528

Atypical retardation patterns in scanning laser polarimetry are associated with low peripapillary choroidal thickness

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; B SCAN; FEMALE; HUMAN; MALE; NORMAL HUMAN; OPTIC NERVE FIBER; PERIMETRY; PERIPAPILLARY CHOROIDAL THICKNESS; PRIORITY JOURNAL; RETINAL NERVE FIBER LAYER; SCANNING LASER POLARIMETRY; SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY; VISUAL FIELD; VISUAL SYSTEM PARAMETERS; BIREFRINGENCE; BRUCH MEMBRANE; CHOROID; EYE REFRACTION; HISTOLOGY; LIGHT; NERVE FIBER; OPTICAL COHERENCE TOMOGRAPHY; PHYSIOLOGY; PIGMENT EPITHELIUM; RADIATION EXPOSURE; RETINA GANGLION CELL; SCLERA;

EID: 84856390797     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.11-7557     Document Type: Article
Times cited : (3)

References (24)
  • 1
    • 0027699308 scopus 로고
    • In vivo retinal imaging by optical coherence tomography
    • Swanson EA, Izatt JA, Hee MR, et al. In vivo retinal imaging by optical coherence tomography. Opt Lett. 1993;18:1864-1866.
    • (1993) Opt Lett , vol.18 , pp. 1864-1866
    • Swanson, E.A.1    Izatt, J.A.2    Hee, M.R.3
  • 2
    • 0036944340 scopus 로고    scopus 로고
    • Detecting the inner and outer borders of the retinal nerve fiber layer using optical coherence tomography
    • Ishikawa H, Piette S, Liebmann JM, Ritch R. Detecting the inner and outer borders of the retinal nerve fiber layer using optical coherence tomography. Graefes Arch Clin Exp Ophthalmol. 2002;240:362-371.
    • (2002) Graefes Arch Clin Exp Ophthalmol , vol.240 , pp. 362-371
    • Ishikawa, H.1    Piette, S.2    Liebmann, J.M.3    Ritch, R.4
  • 3
    • 0025329536 scopus 로고
    • Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness
    • Weinreb RN, Dreher AW, Coleman A, Quigley H, Shaw B, Reiter K. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol. 1990;108: 557-560.
    • (1990) Arch Ophthalmol , vol.108 , pp. 557-560
    • Weinreb, R.N.1    Dreher, A.W.2    Coleman, A.3    Quigley, H.4    Shaw, B.5    Reiter, K.6
  • 4
    • 0037376904 scopus 로고    scopus 로고
    • Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    • Bagga H, Greenfield DS, Feuer W, Knighton RW. Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes. Am J Ophthalmol. 2003;135:521-529.
    • (2003) Am J Ophthalmol , vol.135 , pp. 521-529
    • Bagga, H.1    Greenfield, D.S.2    Feuer, W.3    Knighton, R.W.4
  • 5
    • 33847723920 scopus 로고    scopus 로고
    • Retinal scanning laser polarimetry and methods to compensate for corneal birefringence
    • Zhou Q. Retinal scanning laser polarimetry and methods to compensate for corneal birefringence. Bull Soc Belge Ophthalmol. 2006;89-106.
    • (2006) Bull Soc Belge Ophthalmol , pp. 89-106
    • Zhou, Q.1
  • 6
    • 27244432787 scopus 로고    scopus 로고
    • Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx-VCC, I: Correlation analysis in glaucoma
    • Leung CK, Chan WM, Chong KK, et al. Comparative study of retinal nerve fiber layer measurement by StratusOCT and GDx-VCC, I: correlation analysis in glaucoma. Invest Ophthalmol Vis Sci. 2005;46:3214-3220.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 3214-3220
    • Leung, C.K.1    Chan, W.M.2    Chong, K.K.3
  • 7
    • 77149151229 scopus 로고    scopus 로고
    • Comparison of scanning laser polarimetry and optical coherence tomography in quantitative retinal nerve fiber assessment
    • Schrems WA, Mardin CY, Horn FK, Juenemann AG, Laemmer R. Comparison of scanning laser polarimetry and optical coherence tomography in quantitative retinal nerve fiber assessment. J Glaucoma. 2010;19:83-94.
    • (2010) J Glaucoma , vol.19 , pp. 83-94
    • Schrems, W.A.1    Mardin, C.Y.2    Horn, F.K.3    Juenemann, A.G.4    Laemmer, R.5
  • 8
    • 15044355050 scopus 로고    scopus 로고
    • Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation
    • Bagga H, Greenfield DS, Feuer WJ. Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation. Am J Ophthalmol. 2005;139: 437-446.
    • (2005) Am J Ophthalmol , vol.139 , pp. 437-446
    • Bagga, H.1    Greenfield, D.S.2    Feuer, W.J.3
  • 9
    • 80053237311 scopus 로고    scopus 로고
    • Influence of atypical retardation pattern on the peripapillary retinal nerve fibre distribution assessed by scanning laser polarimetry and optical coherence tomography
    • DOI bjo.2010.190074 [pii] 10.1136/bjo.2010.190074
    • Schrems WA, Laemmer R, Hoesl LM, et al. Influence of atypical retardation pattern on the peripapillary retinal nerve fibre distribution assessed by scanning laser polarimetry and optical coherence tomography. Br J Ophthalmol. 2011: DOI bjo.2010.190074 [pii] 10.1136/bjo.2010.190074.
    • (2011) Br J Ophthalmol
    • Schrems, W.A.1    Laemmer, R.2    Hoesl, L.M.3
  • 10
    • 33748259802 scopus 로고    scopus 로고
    • Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes
    • Da Pozzo S, Marchesan R, Canziani T, Vattovani O, Ravalico G. Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes. Eye. 2006;20:769-775.
    • (2006) Eye , vol.20 , pp. 769-775
    • da Pozzo, S.1    Marchesan, R.2    Canziani, T.3    Vattovani, O.4    Ravalico, G.5
  • 11
    • 33846897492 scopus 로고    scopus 로고
    • The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation
    • Bowd C, Medeiros FA, Weinreb RN, Zangwill LM. The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation. Invest Ophthalmol Vis Sci. 2007;48:223-227.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 223-227
    • Bowd, C.1    Medeiros, F.A.2    Weinreb, R.N.3    Zangwill, L.M.4
  • 12
    • 33749144290 scopus 로고    scopus 로고
    • Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation
    • Reus NJ, Zhou Q, Lemij HG. Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation. Invest Ophthalmol Vis Sci. 2006;47:3870-3877.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 3870-3877
    • Reus, N.J.1    Zhou, Q.2    Lemij, H.G.3
  • 13
  • 14
    • 35548975227 scopus 로고    scopus 로고
    • Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation
    • Mai TA, Reus NJ, Lemij HG. Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation. Ophthalmology. 2007;114:1988-1993.
    • (2007) Ophthalmology , vol.114 , pp. 1988-1993
    • Mai, T.A.1    Reus, N.J.2    Lemij, H.G.3
  • 15
    • 70249097716 scopus 로고    scopus 로고
    • Predictors of atypical birefringence pattern in scanning laser polarimetry
    • Qiu K, Leung CK, Weinreb RN, et al. Predictors of atypical birefringence pattern in scanning laser polarimetry. Br J Ophthalmol. 2009;93:1191-1194.
    • (2009) Br J Ophthalmol , vol.93 , pp. 1191-1194
    • Qiu, K.1    Leung, C.K.2    Weinreb, R.N.3
  • 16
    • 67349172592 scopus 로고    scopus 로고
    • Impact of atypical retardation patterns on detection of glaucoma progression using the GDx with variable corneal compensation
    • Medeiros FA, Alencar LM, Zangwill LM, Sample PA, Susanna R Jr, Weinreb RN. Impact of atypical retardation patterns on detection of glaucoma progression using the GDx with variable corneal compensation. Am J Ophthalmol. 2009;148:155-163 e151.
    • (2009) Am J Ophthalmol , vol.148
    • Medeiros, F.A.1    Alencar, L.M.2    Zangwill, L.M.3    Sample, P.A.4    Susanna Jr., R.5    Weinreb, R.N.6
  • 17
    • 79959297321 scopus 로고    scopus 로고
    • Correlation between scanning laser polarimetry with and without enhanced corneal compensation and high-definition optical coherence tomography in normal and glaucomatous eyes
    • Benítez-del-Castillo J, Martinez A, Regi T. Correlation between scanning laser polarimetry with and without enhanced corneal compensation and high-definition optical coherence tomography in normal and glaucomatous eyes. Int J Clin Pract. 2011;65(7): 807-816.
    • (2011) Int J Clin Pract , vol.65 , Issue.7 , pp. 807-816
    • Benítez-del-Castillo, J.1    Martinez, A.2    Regi, T.3
  • 18
    • 58149268272 scopus 로고    scopus 로고
    • Analysis of the origin of atypical scanning laser polarimetry patterns by polarization-sensitive optical coherence tomography
    • Gotzinger E, Pircher M, Baumann B, Hirn C, Vass C, Hitzenberger CK. Analysis of the origin of atypical scanning laser polarimetry patterns by polarization-sensitive optical coherence tomography. Invest Ophthalmol Vis Sci. 2008;49:5366-5372.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 5366-5372
    • Gotzinger, E.1    Pircher, M.2    Baumann, B.3    Hirn, C.4    Vass, C.5    Hitzenberger, C.K.6
  • 19
    • 84975555428 scopus 로고
    • Spectral reflectance of the human ocular fundus
    • Delori FC, Pflibsen KP. Spectral reflectance of the human ocular fundus. Appl Opt. 1989;28:1061-1077.
    • (1989) Appl Opt , vol.28 , pp. 1061-1077
    • Delori, F.C.1    Pflibsen, K.P.2
  • 20
    • 0030222152 scopus 로고    scopus 로고
    • The pathways of light measured in fundus reflectometry
    • van de Kraats J, Berendschot TT, van Norren D. The pathways of light measured in fundus reflectometry. Vision Res. 1996;36: 2229-2247.
    • (1996) Vision Res , vol.36 , pp. 2229-2247
    • van de Kraats, J.1    Berendschot, T.T.2    van Norren, D.3
  • 21
    • 10444221022 scopus 로고    scopus 로고
    • Imaging of polarization properties of human retina in vivo with phase resolved transversal PS-OCT
    • Pircher M, Gotzinger E, Leitgeb R, Sattmann H, Findl O, Hitzenberger C. Imaging of polarization properties of human retina in vivo with phase resolved transversal PS-OCT. Opt Express. 2004;12:5940-5951.
    • (2004) Opt Express , vol.12 , pp. 5940-5951
    • Pircher, M.1    Gotzinger, E.2    Leitgeb, R.3    Sattmann, H.4    Findl, O.5    Hitzenberger, C.6
  • 22
    • 38949171400 scopus 로고    scopus 로고
    • Value of polarisationsensitive optical coherence tomography in diseases affecting the retinal pigment epithelium
    • Michels S, Pircher M, Geitzenauer W, et al. Value of polarisationsensitive optical coherence tomography in diseases affecting the retinal pigment epithelium. Br J Ophthalmol. 2008;92:204-209.
    • (2008) Br J Ophthalmol , vol.92 , pp. 204-209
    • Michels, S.1    Pircher, M.2    Geitzenauer, W.3
  • 23
    • 0141959615 scopus 로고    scopus 로고
    • Theoretical model of the polarization properties of the retinal nerve fiber layer in reflection
    • Huang XR, Knighton RW. Theoretical model of the polarization properties of the retinal nerve fiber layer in reflection. Appl Opt. 2003;42:5726-5736.
    • (2003) Appl Opt , vol.42 , pp. 5726-5736
    • Huang, X.R.1    Knighton, R.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.